EY-RU : Room operating unit, ecounit

Similar documents
EY-RU : Room operating unit, ecounit

EY-RU : Room operating unit, ecounit

EY-RU : Room operating unit, ecounit

EY-RU 355: Room operating unit, ecounit355

EY-SU 358: Push-button unit for room operating unit, ecounit358

ecounit : Room operating unit with EnOcean wireless technology

EY-RU : Room operating unit with EnOcean wireless technology, ecounit

EY-RU : Room operating unit with EnOcean wireless technology, ecounit

EYE 200: DDC single-room controller, ecos200

I/O module, digital outputs (relays), modu550

EY-IO 534: I/O module, analogue inputs with galvanic isolation, modu534

I/O module, digital outputs (open collector), modu551

I/O module, digital and universal inputs, modu530

EY-EM : Remote I/O module, ecolink

I/O module, universal, digital, S0 inputs, modu533

I/O module, analogue outputs and universal inputs

modu : Local override and indicating units

modunet292: novanet-ethernet interface

EY-RC 208, 209: Room automation stations, ecos208, 209

Sauter Systems

EY-WS 500: Web server for moduweb Vision and moduweb500 BACnet networks

EY-RC 500: Room automation station, ecos500

AVM 321, 322: Valve actuator

Content. Product Description

EY-CM 721: Communication module with EIA-232 and EIA-485 interfaces, modu721

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

QAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC

EY-RC 311: Programmable controller, ecos311

AVF 125S: SUT valve actuator with spring return

EY-CM 721: Communication module with EIA-232 and EIA-485 interfaces, modu721

UCU Room Display. Operation Modes. Features. Applications DATASHEET

Room unit with PPS2 interface

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

Manual operation and local visualisation. with SAUTER EY-modulo.

TXM1.8RB. TX-I/O Blinds module

AVM 105S, 115S: Valve actuator with SAUTER Universal Technology (SUT)

Room unit with PPS2 interface

Pre-programmed room controller with display and communication

Product and functional description

RXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications

Product and functional description

RC-CDTO. Pre-programmed room controller with display, communication and three-point control

Resistance measuring module

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

RXB10.1. Room controller. Siemens Building Technologies Building Automation DESIGO RXB. for chilled ceilings and radiators with EIB bus communication

SAUTER EY-modulo. Compatibility for a secure investment.

Semi flush-mounted room temperature controllers with LCD

Pre-programmed room controller with display and communication

Products no longer available

EY-AS 521: Compact automation station, modu521

RCF-230CTD. Room controller for fan-coil applications with outputs for two thermal or one 3-position actuator or function for an electric heater

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

RDF301 RDF CE1N3171en 02 Jun 2010 Building Technologies

Digital input modules

RMZ792. Bus Operator Unit. Building Technologies HVAC Products. Synco 700

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

Room unit with PPS2 interface

Semi flush-mounted room temperature controllers with LCD

Room Temperature Controller

Universal Modules. Synco 700. Extension modules for use with controls of the Synco 700 family. Use

Master room unit for RRV controllers

Product and functional description

B. AVM321S/AVM322S: 1000N Actuator with analog SUT positioner

ASV215BF152*: VAV compact controller for laboratory and pharmaceutical applications

Room Temperature Controller

Non-communicating room controllers

Eco Climate Control. Intelligent comfort for radio control of surface heating and cooling systems.

USB-KNX Interface OCI702. USB-KNX interface with cables and service bag

1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Status display unit with P-bus connection

Push Button Interface UP 220D31

Technical data. Safety notes. Product features

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

Room unit with PPS2 interface

Products no longer available

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

RCF-230CAD. Room controller with communication for fancoil applications with two analogue V DC outputs

RCF-230CAD. Communicating room controller for fan-coil applications with two analogue V DC outputs

Product and Applications Description. Application programs. instabus EIB Technical Product Information. February 2012

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

SIMOREG 6RA70 DC MASTER SIMOREG CM

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Product and functional description

Product and Function Description

Siemens Spares. RL 513D23 Switching actuator (relay), 3 x 6A. Technical Product Information

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

24V, Motorized Actuators

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Room Temperature Controller with 7-Day Time Switch, LCD and opt. Remote Temperature Sensor

RCF-230CD. Communicating room thermostat for fan-coil applications with on/off outputs

Heating Circuit Controller

RXTH DUAL ROOM SENSOR / SWITCH

Semi Flush-mount Room Temperature Controllers with LCD

Extension module for lighting control

ProcessCalibrator Model CPH6000

Room Temperature Controllers

Transcription:

Product data sheet 9.00 EY-RU 31...36: Room operating unit, ecounit31...36 How energy efficiency is improved Individual setting of occupancy and absence as well as a room setpoint correction and control of lightings and window blinds for optimum energy usage in the room. Visualisation of the local energy consumption by means of multicolour LED indicator Features Part of the SAUTER EY-modulo 5 system family Can be extended using EY-SU 306 switching unit Recording the temperature and controlling rooms with different conditions using communicative EYmodulo 5 ecos unitary controllers The operating mode can be set for the room occupancy and the actuation of a 3-speed fan Room operating unit with a wide range of different functions, designs and colours Device insert with transparent front, fits into frame with 55 x 55 mm aperture Indoor climate can be adapted individually Control of window blinds, windows and lighting (on/off, dim) Display with extensive status information on room conditions Multicolour LED indicators for visualisation of local energy consumption Frame can be ordered as an accessory EY-RU36F001 Technical data Power supply Power supply From ecos 5 Current consumption 8 ma, 0 ma with EY-SU 306 Operating temperature 0...5 C Storage and transport temperature 5...70 C Admissible ambient humidity 10...85% rh, no condensation Measuring range 0...0 C Resolution 0.1 K Ambient conditions Parameters Sensors Functionality Interfaces and communication Connection to automation station Time constant Approx. 7 min Setpoint correction variable Room occupancy (presence) 3 modes, LCD Fan speeds 5 functions, LCD Position LED Switchable: green/red/off Interface RS85 Protocol SLC Control ecos 5, modu51 Line -core twisted Cable length 30 m Connection terminals Pluggable for wire of 0.1...0.5 mm² (Ø 0...0.8 mm) recessed/surface-mounted (see list of accessories) Dimensions W x H x D 59.5 59.5 5 mm Weight 0.1 kg of protection IP 30 (EN 6059) Construction Standards and directives CE conformity according to Protection class III (EN 60730-1) Environment class 3K3 (IEC 6071) EMC directive 00/108/EC EN 61000-6-1, EN 61000-6-, EN 61000-6-3, EN 61000-6- Right of amendment reserved 015 Fr. Sauter AG.1 1/5

Product data sheet 9.00 Overview of types Properties Buttons EY-RU31F001 EY-RU3F001 EY-RU36F001 Accessories EY-SU306F001 correction correction, fan, occupancy correction, fan, occupancy, window blinds, lighting Description Push-button unit, without frame Description 0900*** For frames, mounting plates and adaptors for third-party frames: see product data sheet PDS 9.055 09936000 -pin plug-in connector for connecting ecos room operating unit (10 pcs.) 0991301 Transparent cover (10 pcs.) Description of operation The ecounit 3 room operating units EY-RU 31...36 record the room temperature and have buttons for setpoint correction, to select the occupancy mode and the fan speed and up to two freely allocatable buttons. The room operating units belong to the ecos 5 system family and can be connected to ecos 5 room controllers using the digital RS-85 connection. The LCD can be controlled using the room controller. Intended use This product is only suitable for the purpose intended by the manufacturer, as described in the Description of operation section. All related product documents must also be adhered to. Changing or converting the product is not admissible. Front view and labelling inserts Depending on the type of device, different labelling inserts are included. The operating unit can be adapted to the spatial conditions. 6 EY-RU 31 Labelling inserts included in the scope of delivery EY-RU 3 EY-RU 36 /5.1 Right of amendment reserved 015 Fr. Sauter AG

Product data sheet 9.00 Engineering notes The room operating units EY-RU 31...36 are suitable for various fitting methods. Product data sheet PDS 9.055 shows the mounting options and the accessory material required. The EY-SU 306 switch unit can be used to enhance the EY-RU 31...36 room operating units with 6 additional button functions. EY-SU 306 is connected to EY-RU 31 36 with a -core connection and can only be used in conjunction with this device. Two EY-SU 306s with the same button assignment/function can be connected in parallel. Switch unit EY-SU 306 can be installed up to 30 m (total line length) away from the EY-RU. Connection to ecos 5 The room operating units must be connected to the ecos 5 with a -core cable. If several room operating units are used, these are to be connected in parallel. The system must be disconnected from the electricity supply when the operating units are connected. Addressing the operating units The operating units are connected to the ecos 5 stations via a serial RS-85 bus interface. Up to operating units can be connected to an ecos 5 room automation station. A device address is to be set on the communicative room operating units to ensure that they can be contacted by the ecos 5. The housing lid of the ecounit is located under the transparent cover or labelling insert. All operation and indication functions are clearly labelled on this surface. Sw 1 Sw 6 Sw G 1 H J K 8 M 18 Sw 5 Sw 3 Sw B11779 Sw: Connection name in firmware module. At least buttons are available on all variants: Top left button (A) and top right button (B). On EY-RU 31 devices, these two buttons or LEDs can only be used for addressing. Addressing mode The device address can be set without a time restriction after switching on if: a) no address has previously been assigned to it (ex works condition) or b) there is no communication with ecos, for example because addressing has been carried out incorrectly. The addressing mode is signalised using the bi-colour position LED which is located under the LCD. The LED state during addressing mode overwrites the LED state requested by the user program of the ecos 5. The following applies: Position LED Status Meaning Rot Flashing Device is not addressed Rot Constantly ON Device is in addressing mode (temporary) Green Flashing Valid address is displayed (temporary, approx. 10 s) Green, red Constantly ON or OFF Device in operation, see position LED Non-addressed device, set address In ex works condition, the devices are not addressed, the position LED flashes red after powering up. If button (B) is pressed for over 5 seconds, the device switches to addressing mode and the position LED is lit red continuously. The address 0 is displayed, pressing button (B) again activates the input mode. The device address (1 to ) can now be set, represented by the last digit in the display. In this mode, the digit flashes. The addresses 0 and 5...15 are currently not supported by ecos 5 devices. The address is scanned upwards using button (B) and downwards again using button (A). Pressing and holding button (A) Right of amendment reserved 015 Fr. Sauter AG.1 3/5

B117a Product data sheet 9.00 stores the setting and returns to operating mode. However, if no change is made for 5 seconds, the device returns to the operating mode without saving the settings that have been carried out. Change addressed devices The position LED is lit continuously green, red or OFF according to the ecos 5 user program. If button (B) is pressed for over 5 seconds within the first minute after voltage is restored, the device switches to addressing mode and the set address is displayed. If button (B) is pressed again, the device switches to input mode. The address is scanned upwards using button (B) and downwards again using button (A). Pressing and holding button (A) stores a new address and returns to operating mode. However, if no change is made for 5 seconds, the device returns to the operating mode without saving the settings that have been carried out. Error messages on the LCD display Err: No communication to the automation station Cause: Communication lines are not correctly installed Incorrectly engineered, e.g. ROOM UNIT module not used Automation station has not yet started up completely Position LED As from the devices with index C, the state of the position LED can be set using the ecos 5 user program: continuously green, red or OFF. For example, this function can be used to indicate optimal energy consumption in the room by the colour green. The colour red can be used in the same way in order to indicate energy consumption that is too high. This function is not available for devices up to and including index B. Connect EY-RU 3 ** to the ecos user program How ecos or the operating unit and display respond to the press of a button is programmed in the user program (ecos). The ROOM UNIT module is available in the firmware for this purpose. This module is described in the Firmware modules documentation. Display functions 1 3 5 6 7 8 9 10 11 1 1 = Normal mode = Reduced mode 3 = Night reduction = Seven-segment display 5 = Cooling 6 = Heating 7 = Dew point 8 = Window open 9 = Note 10 = Setpoint correction 11 = Unit for the value displayed 1 = Fan speeds Additional information instructions P100001966 Declaration on materials and the environment MD 9.00 Dimension drawing Connection diagram Disposal M10501 A1053 When disposing of the product, observe the currently applicable local laws. More information on materials can be found in the Declaration on materials and the environment for this product. /5.1 Right of amendment reserved 015 Fr. Sauter AG

Product data sheet 9.00 Connection diagram Dimension drawing 59,5 5 15,5 59,5 Fr. Sauter AG Im Surinam 55 CH-016 Basel Tel. +1 61-695 55 55 www.sauter-controls.com Right of amendment reserved 015 Fr. Sauter AG.1 5/5