Remote Control Unit (RCU) for Kathrein base station antennas with adjustable electrical downtilt and appropriate mechanical interface.

Similar documents
User guide. Bluetooth Music Receiver BM10

High-Resolution Audio Headset MDR-NC750

Box Contents. 1. Balance Keyboard 2. Wireless Receiver 3. Two AAA Batteries. Balance Keyboard user manual

User guide. Bluetooth Keyboard BKB50

Wireless Conference Microphone Bases. User Guide

NUMBER SLIDE ERGONOMICS. Mini Keyboard with Retractable Number Pad

INSTUDIO BLUETOOTH SPEAKER BS1130TUS BS1130TE Instruction Manual

User guide. Bluetooth Keyboard BKB10

Hi! Let s get started. Streaming Stick

Dimensions. Electrical connection. Technical data. General specifications Operating frequency. Indicators/operating means. Electrical specifications

IP Set-top Box (STB) Model No.: SP-110. Rev

INSTALLATION & SETUP GUIDE FOR SINGLE POLE & 3-WAY CONFIGURATIONS IN WALL SOLUTIONS

RONIN 2 Diagram. 1. Grip 2. Gimbal Connector 3. HD-SDI Output 4. Power Button V Accessory Power Port

MiniStation HD-PZNU3. User Manual

Dimensions. ø4 (3x) Electrical connection. Technical data. General specifications Operating frequency. UL File Number

Product Manual. Wired

Product Manual. Wireless

Operating and Storage Temperature 5 General Warnings 6. Extracting Data 8 WARRANTY AND LEGAL

WIFIKIT INSTALLATION GUIDE. WIFIKIT for Centralus Irrigation Management Platform for ICC2 Controllers

ispd PRO Intelligent Sequential Power Distribution System

FT2225 Satellite M2M Terminal. Quick Start Guide

REVOLABS FLX UC 500. Installation and Operation Guide. USB Conference Phone. Models:

ZTE CORPORATION NO. 55, Hi-tech Road South, Shenzhen, P.R.China. MF833V USB Modem Quick Start Guide

RollerMouse Pro3 User Guide

C4DONGLE-3GNA-WBT INSTALLATION GUIDE

H3-EM Electronic Swinghandle Operating Instructions

GETTING STARTED. Cord clip. USB charge cable. Earbud tips. Inner ear hooks. Carry case. The following items are included

1. Getting to know the gimbal

User Manual 318BT. Phantom Powered Bluetooth Audio Receiver

User guide. Stereo Bluetooth Headset SBH80

Product Manual. Wireless

WiFi Smart Converter User Manual

InTemp CX500 Series Temperature Logger Manual

CWA BT320 Product Information Guide

Harris Bluetooth Remote Speaker Mic

CubePro. INF Printing Best Practices. Introduction. Copyright. Compliance. INF Printing Best Practices

WIFI REMOTE VIDEO DOORBELL MODEL: RL-IP02C USER MANUAL

R SERIES INSTALLATION GUIDE

Quuppa LD-7L Installation Guide and Safety Information

Box Contents. RollerMouse Red user manual

Special Documentation Bluetooth module (BT10)

User guide. Stereo Bluetooth Headset SBH60

Additional Help & Info

ShrapnelQuick Guide. Quick Start, would like to show visually for first page: Power On Power Off Pairing Battery Life

Wireless Keyboard/Mouse/Dongle Users Manual

Leadtek S202 Wi-Fi Smart Power Plug. User Manual. Jun 29, 2016

16-Port Serial Card PEX16S550LP

Contour Mouse Wireless

Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any

READ ME FIRST QUICK INSTALL GUIDE. Wireless Controller XWC Includes: One: XWC-1000 Wireless Controller One: Rack Mount Kit One: Power Cord

READ/WRITE MODULES (RWM) RLS

C4DONGLE-3GNAV6 INSTALLATION GUIDE V 1.1

RollerMouse Free3 Wireless. User Guide

CrystalSky User Guide

INSTALLATION AND SETUP GUIDE

X-NUCLEO-NFC04A1. Dynamic NFC/RFID tag IC expansion board based on ST25DV04K for STM32 Nucleo. Description. Features

USB 3.0 SATA HDD/SSD Dock - 1:1 Duplicator SATDOCK2REU3

AIR300 Hardware Manual for Motorola Workabout Pro-G4

Pacific Coast Hwy Suite 290 Hermosa Beach CA Tel: DATASHEET RFD22102 RFduino DIP

INSTALLATION GUIDE 4- IN- ONE EMV L1 & L2 PIN PAD XPED- 8006L2-3CR, POE/USB/RS232

FCC ID: 2AI5B-SO58 SO P

WASP Wireless Acceleration Sensor Puck USER MANUAL

S920 Mobile Payment Terminal PAX TECHNOLOGY LIMITED

QUICK INSTALL GUIDE READ ME FIRST XWC Package Contents: XWC-1000 Wireless Controller. Rack Mount Kit. Power Cord. Wireless Controller

Box Contents. RollerMouse Red plus Wireless

Blackboard MRD5 User Manual

REACH YOUR SUMIT USER GUIDE

Data Sheet. ARISO M30 General GPIO Contactless Coupler Pair

User Information Guide TOSHIBA WT10PE-C

BLACKBERRY RADAR H2 ITC100 1 ITC100 2 February 2019

REVOLABS Elite Wired Microphones

Bluetooth Sound Bar with Built-in Subwoofer Model: SB210

Magellan RoadMate 6630T-LM GPS Navigator & HD Dash Cam Combo. Quick Start Guide

Quick Start Guide VZ-X Wireless, HDMI & USB Document Camera

Printed in Korea Type E. 2014/06 GH A Rev.1.0

Savant Wi-Fi Circa Controller

sher-price.com

PowerView Motorization

Emotiv Insight User Manual. Revision 1.0 June 2015 Emotiv Inc, 2015

Technical Information WirelessHART Adapter SWA70. Smart WirelessHART interface module with power supply for field devices. Products Solutions Services

MD-SPBT01 Bluetooth Speaker

ALL IN ONE PAYMENT TERMINAL

OVERVIEW. *Press and release. *Hold for 5 seconds. *Charging port

T073G-2 HGU ONT User Guide

Shuttle Introduction. Getting Started

AnytimeAnywhereAnyplace

REVOLABS Elite Wired Microphones

QUICK START GUIDE EJ-UW700. Bluetooth C Pen

1. Product Description

User guide. Smart Bluetooth Handset SBH52

GPS Azimuth Adjustment Tool

AINA PTT Voice Responder USER GUIDE

QUICK START GUIDE EO-BG950. Samsung U Flex Headphones

AN-310-RT-4L2W. 310 SERIES MULTI-WAN GIGABIT VPN ROUTERS Quick Start Guide

LM910 Bluetooth 4.0 (Classic + LE) HCI Compact USB SMT Module Dual-Mode with 110m Estimated Max. Distance with Integrated Antenna

KP7 Keypad Quick Install Guide

Wi-Fi expansion board based on SPWF01SA module for STM32 Nucleo. Description

EcoView 8 DO Module Installation and Commissioning

SAFETY WARNINGS AND GUIDELINES

Wi-Fi Circa Switch or Dimmer Keypad

Transcription:

Remote Control Unit (RCU) Remote Control Unit (RCU) for Kathrein base station antennas with adjustable electrical downtilt and appropriate mechanical interface. Compliant to AISG 1.1 and 3GPP/AISG 2.0 Compact size Automatic Confi guration Daisy Chain feasibility Suitable for operation under outdoor condition Type No. 86010148V01 Protocols compliant to AISG 1.1 and 3GPP/AISG 2.0 Logical interface ex factory 1) 3GPP/AISG 2.0 Input voltage range 10... 30 V (pin 1, pin 6) Power consumption < 1 W (stand by); < 10 W (motor activated) 2) 3) Connectors 2 x 8 pin connector according to IEC 60130-9; according to AISG Daisy chain in: male; Daisy chain out: female Hardware interfaces RS 485A/B (pin 5, pin 3); power supply (pin 1, pin 6); DC return (pin 7); according to AISG / 3GPP Adjustment time (full range) 40 sec (typically, depending on antenna type) Adjustment cycles > 50,000 Temperature range 40 C +60 C Protection class IP 24 Lightning protection AISG interface (each pin) 2.5 ka (10/350 µs) 8 ka (8/20 µs) Housing material Profi le: Aluminum anodized; cover: Aluminum die cast coated Weight 455 g (0.99 lbs) Packing size 245 x 93 x 102 mm, (9.6 x 3.6 x 4 inches) Dimensions (H x W x D) 177.5 x 59.5 x 49.5 mm, (7.0 x 2.3 x 1.9 inches) 1) The protocol of the logical interface can be switched from 3GPP/AISG 2.0 AISG 1.1 to with a vendor specifi c command. Start-up operation of the RCU is only possible in a RET system supporting 3GPP/ AISG 2.0! The protocol can also be changed as follows: 3GPP to AISG 1.1: Enter AISG1 into the additional data fi eld Installer s ID and perform a layer 2 reset or a power reset. AISG 1.1 to 3 GPP: Enter 3GPP into the additional data fi led Installer s ID and perform a layer 7 reset or a power reset. After switching the protocol any other information can be entered into the Installer s ID fi eld. Please note: If the Primary of the RET system doesn t support the standard of the logical interface ex factory, the RCU must be switched to the appropriate standard of the Primary before installation. Please contact Kathrein for further information. 2) The tightening torque for fi xing the connector must be 0.5 1.0 Nm ( hand-tightened ). The connector should be tightened by hand or using the torque screwdriver (85010080) as described in the connecting cable data sheet (85010007,...) 3) The RCU get s the information stored in the antenna after power on automatically if a corresponding antenna is used. It is not necessary to confi gurate the RCU manually. Standards: Certifi cation: Scope of supply: M42x1.5 EN 60950-1 (Safety) EN 60950-22 (Safety Equipment installed outdoor) EN 55022 (Emission) EN 55024 (Immunity) ETS 300019-1-4 (Environmental) UL 60950-1; 1 st edition CE, FCC Remote Control Unit Assembly paste 173.6 mm (6.8ʺ) Ø 46 mm (Ø 1.8ʺ) 49.5 mm (1.95ʺ) 28.5 mm (1.1ʺ) 59.5 mm (2.34ʺ) Daisy chain in (male) Daisy chain out (female) Bottom view of RCU 8 mm (0.31ʺ) 33.2 mm (1.27ʺ) www.kathrein.de 86010148V01 Page 1 of 5

Remote Control Unit (RCU) Please note: Additional grounding of the RCU is not required if the RCU is fixed to an antenna with proper grounding. Please assure that grounding of the antenna has been carried out according to all relevant local regulations. Please note: As a result of more stringent legal regulations and judgements regarding product liability, we are obliged to point out certain risks that may arise when products are used under extraordinary operating conditions. The mechanical design is based on the environmental conditions as stipulated in ETS 300 019-1-4 and thereby respects the static mechanical load imposed on an antenna by wind at maximum velocity. Wind loads are calculated according to DIN 1055-4. Extraordinary operating conditions, such as heavy icing or exceptional dynamic stress (e.g. strain caused by oscillating support structures), may result in the breakage of an antenna or even cause it to fall to the ground. These facts must be considered during the site planning process. The installation team must be properly qualified and also be familiar with the relevant national safety regulations. The details given in our data sheets have to be followed carefully when installing the antennas and accessories. The limits for the coupling torque of RF-connectors, recommended by the connector manufacturers must be obeyed. Any previous datasheet issues have now become invalid. Description of the adjustment mechanism (protective cap removed): 1 1 2 2 ➀ Adjustment wheel with twist-lock function. ➁ Downtilt spindle with integrated scale. ➀ Thread for fi xing the pro tective cap or the RCU (Remote Control Unit). ➁ Gearwheel for RCU power drive. To set the downtilt angle exactly, you must look horizontally at the scale. The lower edge of the gearwheel must be used for alignment. Page 2 of 5 86010148V01 www.kathrein.de

Instructions for RCU Installation Attaching the RCU (Remote Control Unit) for remote-controlled downtilt adjustment: Twist off the protective cap completely from the antenna. Check the proper function of the phase shifter over the entire adjustment range by twisting the adjustment wheel in such a way, that the spindle moves completely in and out. Reset the downtilt to 0 degree. Completely remove the black adjustment wheel by simply pulling it downwards. Clean the thread surface. Apply the assembly-paste evenly onto the full circumference of the thread as illustrated in the fi gure. Note! Avoid ingestion and contact with eyes. In case of contact with eyes rinse thoroughly with plenty of water. In case of irritation seek medical advice. Avoid long-term contact with skin. In case of contact with skin wash off with soap and water. For further information please read the safety data-sheet Klüberplex AG 11-461 by company Klüber Lubrication München KG Geisenhausenerstraße 7 D-81379 München http://www.klueber.com Push the attachment nut of the RCU down towards the housing. Place the RCU carefully over the adjustment spindle, observ ing the correct alignment of the RCU with regards to the antenna, i.e. the fl at surfaces of the attachment fi xture on the antenna side and those inside the RCU housing must lie fl at against each other. Push-up the RCU carefully to the stop at the antenna. Please note! Do not twist the RCU during attaching to the antenna, as this may damage the adjustment spindle. Tighten the RCU attachment nut using a torque-wrench; wrench width = 41 mm, min. torque = 15 Nm, max. torque = 18 Nm. Connect the RCU control cable immediately after attachment of the RCU. The tightening torque for fi xing the control cable connector must be 0.5 1.0 Nm ( handtightened ). Please note! In cases where a mechanical downtilt unit is installed, this must not be set for a downtilt of more than 14 degrees. Connecting the control cables: Connect a control cable to the daisy chain input of the RCU. The tightening torque for fi xing the connector must be 0.5 1.0 Nm ( hand-tightened ). The connector should be tightened by hand only! Please note: If the daisy chain output is not used, do not remove the protection cap. For daisy chain operation, remove the protection cap and attach a control cable to interconnect with the daisy chain input of the subsequent RCU. Please note: Do not remove the protection cap on the daisy chain output of the last RCU device. www.kathrein.de 86010148V01 Page 3 of 5

FCC Statements FCC Statements FCC 15.19 This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC 15.105 Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help. Canada CNR-Gen Section 7.1.3 This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:(1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. ICES-003 This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. FCC 15.21 (Warning Statement) [Any] changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment. Page 4 of 5 86010148V01 www.kathrein.de

FCC Statements Compliance Information Statement (Declaration of Conformity Procedure) Responsible Party: Kathrein Inc., Scala Division Address: PO Box 4580, Medford Oregon. 97501 Telephone: (+01)541 779 6500 Type of Equipment: Model Name: Remote Control Unit (RCU) FCC ID SP3-86010148V01 www.kathrein.de 86010148V01 Page 5 of 5