Hitec QPS product range

Similar documents
How green is green? The environmental benefits of using Diesel Rotary UPS systems to support critical loads in the datacenter. Summary.

Rotabloc Diesel Rotary UPS Systems

Liebert. APM from 30 to 300 kw. The Compact Row Based UPS With FlexPower Technology

Keor HPE UPS. THREE-PHASE UPS from 60 to 300 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Keor HPE UPS THREE-PHASE UPS. from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Tel: AC Power for Business-Critical Continuity TM

Modular three-phase UPS system. Conceptpower DPA kva True modular UPS system for critical applications

LEVELUPS T3 3 UPS. SERIES kva ONLINE UPS 3:3 PHASE VFI TYPE. Highest Reliability with Embedded Isolation Transformer

LEVELUPS T3. SERIES kva ONLINE UPS 3:3 PHASE VFI TYPE. Highest Reliability and Robust Protection for Industrial Loads

Distributed by. Keor T UPS THREE-PHASE UPS. from 10 to 120 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Est FlexiPower Ultra UPS FPX Ultra kVA

10 kva 3/1 15 kva 3/1 20 kva 3/1 10 kva 3/3 15 kva 3/3 20 kva 3/3 30 kva 3/3 40 kva 3/3 UOUS SERV WARRANTY

Rotabloc Diesel Rotary UPS Systems

PowerWAVE 9000DPA. (30-50 kva) Parallelable up to 1.5 MVA

Est FlexiPower Maxi UPS FPX Maxi kVA

PowerWAVE 8000DPA Modular UPS designed for low and medium power applications

Liebert NXr Series 30kVA to 160kVA. AC Power for Business-Critical Continuity TM

MGE Galaxy /900 kva

PowerWAVE 8000DPA. (10 20 kva/kw) Parallelable up to 400 kva/kw

Liebert NXC from 10 to 60kVA

LP 33 Series UPS. Digital Energy. GE Digital Energy

Est FlexiPower Maxi. Modular UPS kw

Galaxy VX. From 500 to 1500 kw N+1 Parallel solutions up to 4000 kw 380V / 400V / 415V / 440V. schneider-electric.com/ups

The Power of Modularity

R E C T I F I E R I N V E R T E R C O N V E R T E R MP7

Est Constant Current Regulator MC4 3kW 30kW

PowerWave 9000DPA Designed to meet the requirements of today and tomorrow

PowerWAVE 9000DPA Designed to meet the requirements of today and tomorrow

84 kw, Tier 3, Direct Expansion, 937 ft 2

MP7. Uninterruptible Power Supply

Product Brochure Eaton 93PR UPS kw

GE Consumer & Industrial Power Protection. Digital Energy LP Series UPS. Uninterruptible Power Supply 3-30 kva

Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design.

Liebert APM The Compact Row-Based UPS With Flexpower Technology TM 30kW - 300kW. AC Power For Business-Critical Continuity

Galaxy VX. From 500 kw to1500 kw N+1 Parallel solutions up to 4000 kw 480 V. schneider-electric.com

APMTM UPS 18kW - 90kW The Flexpower Technology for mission critical applications

9900B UPS. The POWER of Green UNINTERRUPTIBLE POWER SUPPLIES

PowerWAVE 9500DPA. ( kva/kw) Parallelable up to 3 MVA/MW

Liebert APM from kw. The Compact Row-Based UPS With FlexPower Technology TM

Liebert NXC. 10 to 40kVA Compact and Reliable Power in a Fully Integrated Packaged Solution

UPS. centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw INFINITE POWER. Mission Critical Applications

9900AUPS. Efficiency UNINTERRUPTIBLE POWER SUPPLIES 80KVA 225KVA

PRODUCT BROCHURE. Conceptpower DPA V UL Modular UPS 20kW 600kW

Liebert APM The Compact Row-Based UPS With Flexpower Technology TM 30kW - 300kW. AC Power For Business-Critical Continuity

APMTM UPS 30kW - 300kW The Compact Row-Based UPS With Flexpower Technology

Product brochure. Conceptpower DPA Modular UPS DPA 120 UL 208V: 20kW 600kW

Converged Power Solutions. Data center power reinvented

02 Why Does My IT Infrastructure Need a UPS?

PRODUCT BROCHURE. Conceptpower DPA V UL Modular UPS 100kW 3MW

Symmetra PX. Symmetra PX 48kW Scalable from 16kW to 48kW. Modular, Scalable, High-Efficiency Power Protection for Data Centers

the Centric 300 An advanced modular UPS up to 1800kVA/kW

Liebert NX Series. 30kVA to 200kVA. AC Power for Business-Critical Continuity TM

ARCHIMOD HE 240/480 HIGH POWER MODULAR UPS THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURE

Liebert APM. The Compact, Row-Based UPS with Flexpower Technology 30kW - 300kW

BT300 HVAC Drives. Designed for HVAC. Description. Technical Specification Sheet Document No March 4, 2013

Powerware P95

GE Critical Power. LP Series UPS. Uninterruptible Power Supply 3-40 kva. imagination at work

Socomec Netys PR RT U P S TOWER / RACK MOUNT

Power Quality Solutions Eaton 93PR UPS

Symmetra PX 48kW. Scalable from 16 to 48kW. Make the most of your energy TM. Modular, Scalable, High-Efficiency Power Protection for Data Centers

DPA UPSCALE TM RI kw Technical Specifications

Modular, scalable, high-efficiency power protection for data centers

Zero downtime for mission critical applications? Absolutely.

Schneider Electric Easy UPS 3S

GE Consumer & Industrial. Digital Energy LP Series UPS. Uninterruptible Power Supply 3-30 kva. GE imagination at work

Commercial Projects. Data Centres & IT. Alternative Energy Generation. Manufacturing & Service

ELEKTRA SMALL FOOT PRINT SERIES. Mission Critical & I.T Grade UPS I.T GRADE ONLINE DOUBLE CONVERSION UPS 10KVA ~ 200KVA (3/3)

Newave s approach for protecting mission critical application

ITA2 UPS 5-20kVA Compact, Efficient & Robust UPS For Critical Applications

ITA2 UPS 5-20kVA Compact, Efficient & Robust UPS For Critical Applications

Data Center Integrated solutions

Data Center Integrated solutions

Highly Efficient Power Protection for High Density Computing Applications

Liebert NX - Next Generation UPS for protecting your Business Critical Systems. AC Power Systems for Business-Critical Continuity

UNINTERRUPTIBLE POWER SUPPLIES 9900A >9900AUPS

Business continuity made easy

Liebert exm UPS kva/kw Efficient, Flexible Power Optimized for Midsize Applications FLEXIBLE. ECONOMICAL. INTELLIGENT

Liebert EXL TM S kw to 1200 kw. Enhanced Design and Improved Efficiency

GE Consumer & Industrial Power Protection. Digital Energy LP Series UPS. Uninterruptible Power Supply 3-30 kva. GE imagination at work

3300 kw, Tier 3, Chilled Water, 70,000 ft 2

exm UPS 80kW - 200kW Efficient, Flexible Power Optimized For Medium Size UPS Applications

MSYS 4480 AC Systems Winter 2015

Schneider Electric Easy UPS 3S

SCALABLE, FAULT TOLERANT, INDUSTRIAL PROTECTION

Liebert. EXS from 10 to 20 kw. Optimized and integrated three-phase UPS solution with high efficiency power protection

Liebert NXr Series 15KVA to 90KVA (208V/220V) AC Power for Business-Critical Continuity

Evaporative free air cooling technology Providing evaporative free air cooling solutions.

Nominee: Riello UPS with The Rosebery Group

Data Center Trends: How the Customer Drives Industry Advances and Design Development

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

Data Sheet FUJITSU Server PRIMERGY CX400 M4 Scale out Server

CPS VS UPS FOR POWERING DATA CENTERS

Est Constant Current Regulator MC2 3kW 30kW

Resilience, Efficiency and Scalability in Data Centre UPS Systems

Galaxy VM. 160/200 kva Parallel capable up to 800 kva. Three-phase power protection. Galaxy VM trusted partner for your business continuity

UPS Sentry MPS. SENTRY MPS is also compatible with different battery technologies: openvase lead acid and AGM and Gel VRLA, NiCd.

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Liebert. ITA2 TM UPS 5-20kVA Compact, Efficient & Robust UPS For Critical Applications

PowerWAVE 9250DPA. ( N+1 kva/kw) Parallelable up to 1.5 MVA/MW

Eaton 9EHD Industrial UPS

Transcription:

Hitec QPS product range Continuous Power Uninterrupted Power Quality Power Highest No-Break UPS Ratings Exceptional Power Density Modular Design Approach Best End-to-End Efficiency Optimized Availability

A reliable and resilient data center infrastructure mitigates the operational risk and thereby optimizes the availability of data processing. Functional design requirements, both for computing processes and supporting facilities such as cooling and power, must meet the business objectives and site management philosophy. The need for scalability of capital investments, modularity in the design approach and increasing power density influence the choice of the UPS system for providing conditioned, uninterruptible and continuous power supply to the IT equipment. The Hitec QPS product range meets all these requirements. Exceptionally High No-Break UPS Ratings The Hitec QPS product line is designed to reduce plant space by creating the highest power density per square meter in industry today. The Hitec QPS product is available with No-Break UPS ratings up to 2400 kw/3000 kva in 50 Hz operation, and up to 2880 kw/3600 kva at 60 Hz. The advantages of the higher ratings are many. Engineers can design the entire facility with No-Break UPS power. Mechanical loads no longer get interrupted when the mains fail. The Hitec QPS supports 100% of the facility on uninterruptible power, using fewer machines to support a given load, meaning the installation costs will be proportionately lower. Fewer machines also result in lower overall maintenance costs. Industry-Best Total Cost of Ownership The Hitec QPS has a unique combination of features that give our customers outstanding performance plus a significantly lower Total Cost of Ownership. It is optimized to meet energy efficiency demands with an end-to-end efficiency of up to 97%. The Hitec QPS product line is designed to reduce plant space by creating the highest power density. Each of these features has its own set of benefits. Together, they set the new standard of value in the Uninterruptible Power Supply industry. 2

Optimized for Highest Efficiency The Hitec QPS has many innovations to improve its energy efficiency. The generator and reactor have been optimized to work together for lower losses. Controlled Energy Storage Optimization (ESO) mode automatically monitors the connected load and reduces flywheel speed in response to an extended period of partial loads; typical in a data center environment. This reduces standing losses during partial loads, but restores the flywheel to full speed as loads increase. Fanless cooling of the kinetic energy transfer module eliminates losses normally caused by forced-air cooling. Hitec QPS System features High energy efficiency (up to 97%) Customer benefits Lower operational cost Lower PUE Less waste heat Low space requirements High power density (40-60% less than static UPS) Reduce building costs Increase of available data floor area Integrated functionality combining UPS and standby diesel generator No use of batteries Robust, compact and modular design High system availability Active filter supplies conditioned power No battery replacement every 3-5 years No chemical waste Compact and simple Environmental Friendly Versatile Hardware Configuration The Hitec QPS concept is based on proven Hitec technology. The design combines different functionalities using pre-engineered modules and components are arranged to greatly enhance their usefulness. The diesel engine and generator can together function as a traditional genset even with the energy storage system disconnected. Another benefit is that the generator, ETM and flywheel can together function as a Rotary UPS even when the diesel is disabled for maintenance. Those elements can provide kvars and harmonics mitigation, plus ride-through energy to support the total system. 3

Low-Stress Energy Storage Technology The Hitec QPS energy storage system has two elements: an Energy Transfer Module (ETM) and a high-energy, low-speed flywheel. The ETM spins with the generator at 1500 rpm/50 Hz and at 1800 rpm/60 Hz. The flywheel spins at approximately 2900 rpm. This lower speed allows extended maintenance intervals. The flywheel is available in different sizes, to match the required output power and autonomy time. With variable speed controls, the amount of energy stored can be controlled, to match the power need, hence increasing the overall system energy efficiency significantly, especially at partial loads. The Energy Transfer Module (ETM) is the heart of the system. It transfers the kinetic energy stored in the flywheel to the generator, so guaranteeing an uninterrupted supply of power. 4

The freewheel clutch is a robust mechanical machine, self lubricating and with low maintenance requirements. It operates without any external control thereby ensuring a shockfree delivery of power. The diesel engine is kept in optimal condition to enable a secure start and quick load acceptance. Emission optimized engines are available to comply with carbon emission standards like EPA or TA. Diesel Start Delay function is available to prevent a diesel start within the first two seconds of a supply out of tolerance occurring. The generator is matched with the nominal load and reactor ensuring good dynamic system behaviour. Careful design of the exact characteristics of the generator and reactor provides an active filter to remove both utility and load-borne anomalies, like voltage spikes, frequency variations and harmonics distortions. Load and utility short circuits can be cleared, without the need to switch the load to bypass. The generator also enables power factor improvement achieving close to unity (>0.98). 5

System Advantages Reliability A straightforward design with proven technology, a brushless system and low speed flywheel ensure high reliability. Efficiency The most efficient fully operational UPS system in the market, up to 97%. Power factor improvement The input power factor remains close to unity, so minimising reactive power charges from the utility provider. Dynamic filter The choke and generator act as rotating filter, filtering harmonics from both input and output. Continuous Power Uninterrupted Power Quality Power Voltage regulation The output voltage is controlled independent from the input voltage. Small footprint The footprint is 40 to 60% less when compared with static UPS systems. Energy storage optimization mode The standard energy storage optimization mode (ESO mode) reduced the accumulated flywheel energy to the level that is needed to guarantee the UPS function, thus saving energy. Diesel start reduction The diesel start reduction feature, makes a delayed start of the diesel possible, preventing the diesel from starting for short interruptions of the mains supply, so saving diesel. System Power (kw) Rated Power (kva) Length (cm) Width (cm) Height (cm) Weight (tons) 50 HZ 2000 2500 1050 193 255 30.5 2400 3000 1130 193 255 33.5 60 HZ 2400 3000 1120 193 255 32.0 2880 3600 1130 193 255 34.0 Technical system specification System specification: Allowable Power Factor between 0,8 lagging and 0,9 leading Rated Power Factor 1,0 Nominal voltage: 400/480V Nominal frequency: 50/60 Hz Input specifications: Input mains-voltage fluctuations: ± 10 % Input frequency tolerance: ± 1 % Input power factor under nominal conditions: ~1,0 Harmonic filtering under nominal conditions: 99 % Max. reverse current during up-stream short circuit: up to 2 * In Output specifications: Output voltage steady state: ± 1 % Output voltage dynamic (during mains interruption): ± 5 % Output voltage dynamic (during mains short circuit): within ITI(CBEMA) Output frequency mains operation: as mains frequency Output frequency diesel operation steady state: ± 0,5 % Output frequency dynamic: ± 2.0 % System voltage symmetry: 2 % Radio interference level (EN 55.011): Class A Diesel engine: Operating with diesel fuel corresponding: Grade No.2D per ASTM D975 Engine power (standby power) corresponding: DIN/ISO 3046 Ambient conditions: Ambient temperature: min. 5 and max. 50 ºC Humidity: max. 85% noncondensing Altitude: max. 400 m All data in this brochure is for information and is subject to change without prior notice. No rights can be obtained from the contents of this brochure. Data provided in our offering prevail at all time. 6

Tailor made systems Hitec Power Protection s QPS product can be fully integrated into a UPS system to meet the site specific design requirements. When combining units standard systems are available to offer: Growth scenarios to match capital investment and operational costs with revenues generated Maximum availability of processes to meet industry standards by creating redundancy and eliminating any single points of failure Designs in line with the most rigorous operating and maintenance scenarios Flexibility, with the ability to migrate power around in the data center Tailor made solutions using proven and tested designs Optimal cost control Fast speed of deployment Low/medium voltage systems Remote monitoring, analysis and support system Netprotect: Advance remote montoring Hitec Power Protection offers its NetProtect monitoring system allowing remote monitoring though secure and safe communication protocol. Information on system operation, history of incidents and trending data can be viewed and analyzed by experienced Hitec personnel. Monthly analysis of system behaviour and autocall functionality can be activated to provide pro-active service and to optimize planned maintenance. This gives the data center operator better understanding of required maintenance activities and so can help to minimize the impact of maintenance on the data center operation. 7

Global partner to rely on Hitec Power Protection designs and manufactures high quality Diesel Rotary UPS systems. Our global installed base demonstrates our track record in the delivery of uninterruptible and continuous power supply for mission critical process. Worldwide customers that operate data centers rely on our proven UPS technology. Using the Hitec QPS product ensures a reliable data center power supply infrastructure, with a low component count and technical lifetime of more than 20 years. Hitec Power Protection has its worldwide headquartres based in Almelo, The Netherlands and regional offices strategically placed throughout the world. Our global service organization, together with a worldwide network of qualified service partners, provides 24/7 helpdesk and (remote) support in line with the service level required by and agreed with the customer. Global service network Worldwide, World-class Hitec Power Protection offices partners For contact details please visit www.hitec-ups.com