CPCI System Subrack 3 U

Similar documents
CPCI System Subrack 1 U

CPCI System Subrack 3 U

VME64x System Subrack 1 U

3+1 U CPCI Serial System

3/4 U CPCI Serial Case System

VME64x System Subrack 8 U

VME System Subracks 3 U / 4 U

CPCI PSB System Subrack 10 U

VME Subrack System 7 U

VME System Subracks 7 U / 8 U

CPCI/CPCI Serial Hybrid System 3+1 U

User's Manual CPCI Basic 3U, 30HP CPCI Basic 3,5U, 42HP

CPCI Basic 1U, 2U and 4U User's Manual

User's Manual CPCI Basic 3U and 6U, 84HP VPX Basic 4U, 84HP Fan Tray 1U, 84HP

User's Manual CPCI Basic 4U, 63HP PXI Basic 4U, 63HP

VME64x Basic 1U, 2U and 4U User's Manual

CPCI-PS24 24V-Power Supply

Power Supply. Users Guide PRODUCT MANUAL. WESTELL.COM Westell Technologies MNL rd

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

MIC-3002A Series. 3U 6-slot CompactPCI Enclosures with Rear I/O and 6" LCD. User Manual

Voltage Current Front-mounting bracket

Operating Instructions

MC 11 EB-2 Power supply cabinet with external bus, AC version

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Power supply CP-C 24/5.0

MIC-3001/8. 3U/4U CompactPCI. Enclosure for Rackmounting

Switch Mode Power Supply S8VT 120/240/480/960 W Models

Lightspeed Advanced Reporting Bottle Rocket Hardware Installation Guide

LVN5200A-R2, rev. 1, Hardware Installation Guide

Dell MD1280 Storage Enclosure Getting Started Guide

MIC-3001/8. 3U/4U CompactPCI Enclosure for Rack Mounting. User Manual

Redundancy unit CP-A RU

CompactPCI SYSTEM POWER SUPPLIES. CPCI SERIES 150 to 350 Watts, Ac Input with PFC DPCI SERIES 150 to 350 Watts, 48 Vdc Input FEATURES:

Output Voltage* (nom.)(adjustable)

CPCI - 6U - AC - 600W

vme, vme64x, vxs, vpx

TRC-190 User s Manual

MINI-PS AC/10-15DC/8

Ordering Information. Three-phase Input Switch Mode Power Supply S8VT S8VT. Model Number Legend

Power supply CP-E 48/1.25 Primary switch mode power supply

Power supply CP-E 24/10.0 Primary switch mode power supply

VP ELECTRONIQUE MASSY - Tel

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

CPS Industrial Power Supply

Industrial Power Supplies

Power supply CP-E 24/0.75 Primary switch mode power supply

-AC Input- Voltage/Current...AC V, 47-63Hz, 5.5A Max, 1 Phase. Fusing...AC 6.3A, 250V internal line fuse provided, non-user serviceable. Power F

NI PXI-1042 Series Power Supply Shuttle

The SFP BG meets international safety requirements and is CE marked to the Low Voltage Directive (LVD). Datacom Distributed Power Systems

(877) CPCI-3U Series. Input Voltage Range AC Input. Input Voltage Range 48VDC Input. Input Voltage Range 24/28VDC Input

MODEL 805 USER MANUAL

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

1 Airflow via normal convection or forced-air cooling devices in the enclosure or housing outside of the subrack.

ATR012-HEX-3U. 1/2 ATR Chassis, Sealed w/heat Exchange KEY FEATURES

Series MPM-815H 150W PFC MEDICAL ATX POWER SUPPLY

Output Voltage* (nom.)(adjustable)

MIC Advantech CompactPCI. Modular Industrial Computer. 10U high 8-slot enclosure with CT bus and rear I/O for CompactPCI backplane

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

2U/3U Redundant Power Supply. 400W for IPC-Computer

EthernetConnect and IP/Analog Fiber Accessories POWER SUPPLIES, RACK CHASSIS WITH INTERNAL POWER SUPPLY

The APR YE meets UL/CSA and all international safety requirements. It is SELV. Min Typ Max 90

CMC III Universal Sensor

Power supply CP-D 12/2.1 Primary switch mode power supply

Safety Standards. Model Number:

Installation Manual. Mounting Instructions Mechanical Mounting. Luminato. Teleste Corporation

SPECIFICATIONS. Input Output Agency Approvals 0 ~ 62.5A. toll-free (603)

< 50 A max. (115 VAC) / < 70 A max. (230 VAC)

Table of Contents Quick Install Guide page Introduction Safety Rack System Precautions ESD Precautions...

General-Purpose 8-Slot Chassis for PXI

PHOENIX CONTACT - 07/2006

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

Junos WebApp Secure 5.0 Hardware Guide

Model No. ( Single Output ) ATC-3.3S ATC-5S ATC-12S ATC-15S ATC-24S Max Output Wattage (W) 10W 10W 10W 10W 10W VAC or VDC

Chrome DIN Rail Power Supply 12V 9.96W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1A

S66 Series Electronic Fan Speed Control

REVISION HISTORY Rev Level Rev Date Change Made Reason for Change Effective Approved By A 13/12/08 Specification Release 13/12/08 S. Sadot A1 13/02/09

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

CMC III Temperature/Humidity Sensor

PMT. Safety Standards. Model Number:

General Purpose Chassis for PXI and CompactPCI

TABLE OF CONTENTS 1. OVERVIEW... 1

Safety Standards. Model Number: Unit Weight:

Industrial Power Supplies

KUANTECH (SHEN ZHEN) COMPANY LIMITED KSAFD W1UK

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

Preparing to Install the VG248

ATS22D47S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

Rhino PSM Power Supplies. Operating Instructions

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

CPCI - 6U - DC - 350W

I STAR COMPUTER CO., LTD

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Transcription:

User s Manual Product No.: Doc-No: 63972-227_R1.1 April 18, 2011

Rev. Date updated Change R1.0 January 14, 2008 Initial Release R1.1 April 18, 2011 Fan Tray with mini compression latch Impressum: Schroff GmbH D-75334 Straubenhardt, Germany The details in this manual have been carefully compiled and checked - supported by certified Quality Management System to EN ISO 9001/2000 The company cannot accept any liability for errors or misprints. The company reserves the right to amendments of technical specifications due to further development and improvement of products. Copyright 2011 All rights and technical modifications reserved.

Table of Contents 1 Safety... 1 1.1 Intended Application... 1 1.2 Safety Instructions... 2 1.2.1 Safety Symbols used in this document... 2 1.3 General Safety Precautions... 2 2 Product Definition... 3 2.1 References and Architecture Specifications... 3 2.2 Subrack System Overview... 4 2.3 Subrack:... 4 2.4 CPCI Backplane... 4 2.5 Power Supply... 5 2.5.1 Grounding/Earthing... 5 2.5.2 ATX Power Supply... 6 2.6 Cooling... 7 2.7 Remove/Install Fan Tray... 7 3 Installation... 9 3.1 General Installation Guidelines... 9 3.1.1 Unpacking... 9 3.1.2 Ensuring Proper Airflow... 9 3.2 Rack-Mounting... 10 3.3 Initial Operation... 10 4 Service... 11 4.1 Technical support and Return for Service Assistance... 11 4.2 Declaration of Conformity... 11 4.3 Scope of Delivery... 12 4.4 Accessories... 12 4.5 Spare Parts... 12 5 Technical Data... 13 6 Dimensions... 14 www.schroff.biz I R1.1, April 18, 2011

www.schroff.biz II R1.1, April 18, 2011

Safety 1 Safety 1.1 Intended Application The CompactPCI (CPCI) system subrack, described in this manual, is intended as a platform for a microcomputer system based on the CompactPCI Standard PICMG 2.0 Rev.3. The CPCI system subracks are designed for protection class IP 20 and can be used only in the resp. environments. For higher protection requirements, e.g. IP 54/55 you must install the system subrack in a protective case. CPCI system subracks are not end-products, so there is no valid approval for this unit. In order to enable stand-alone functionality, additional elements are required. An operational system is achieved only by way of appropiate CPCI boards. The completion and final testing of the units have been carried out, or at least supervised, by qualified technicians. These instructions are directed exclusively to these qualified technicians i.e.engineers, trained and qualified electricians etc. Make sure that: the finished system complies with the safety regulations currently applicable in the country it is going to be used. the finished system complies with all other regulations and specifications at the place and country of use, e.g. interference limits, approval by the telecommunications authorities. www.schroff.biz 1 R1.1, April 18, 2011

Safety 1.2 Safety Instructions The intended audience of this User s Manual is system integrators and hardware/software engineers. 1.2.1 Safety Symbols used in this document Hazardous voltage! This is the electrical hazard symbol. Familiarise yourself with the danger of electrical voltages and the safety precautions to avoid accidents before starting to work with parts that carry dangerous voltages. Caution! This is the user caution symbol. It indicates a condition where damage of the equipment or injury of the service personnel could occur. To reduce the risk of damage or injury, follow all steps or procedures as instructed. Danger of electrostatic discharge! Static electricity can damage sensitive components in a system. To avoid damage, wear ESD wrist straps or at regular intervals touch blank enclosure parts. 1.3 General Safety Precautions Warning! Voltages over 60 VDC can be present in this equipment. This equipment is intended to be accessed, to be installed and maintained by qualified and trained service personnel only. This equipment is designed in accordance with protection class 1! It must therefore be operated only with protective GND/earth connection! Service personnel must know the necessary electrical safety, wiring and connection practices for installing this equipment. Install this equipment only in compliance with local and national electrical codes. www.schroff.biz 2 R1.1, April 18, 2011

Product Definition 2 Product Definition The Schroff CPCI system subrack consists of: A shielded 19 subrack with front and rear card cage for 6 U boards according to CompactPCI Standard PICMG 2.0 Rev.3 A 6 U 6 slot CPCI Backplane, system slot left (bottom) An ATX power supply (250 W) with wide range input Fans for the active cooling of the boards DC switch 2.1 References and Architecture Specifications User Manual CPCI Backplanes Order no.: 73972-101 Technical Data Schroff CPCI Backplanes 23006-7xx Order no.: 73972-088 User Guide Schroff CPCI Backplanes 23006-798 Order no.: 63972-214 Further information can also be found in the catalogue Electronic Packaging and on the internet under www.schroff.biz www.schroff.biz 3 R1.1, April 18, 2011

Product Definition 2.2 Subrack System Overview Figure 1: System Overview 1 Fan Tray 3 ATX Power Supply 2 Front Card cage with guide rails 4 DC Switch 12311800 2.3 Subrack: 2.4 CPCI Backplane The 3 U 19 subrack is based on the Schroff europacpro system with EMC shielding. The card cage enables the horizontal assembly of 6 CPCI front boards (6 U, 4 HP, 160 mm deep) and 6 Rear I/O Boards (6 U, 4 HP, 80 mm deep). The right guide rails of the card cage are equipped with ESD clips. The horizontally assembled 6 U Backplane provides: CompactPCI bus (PICMG2.0 R.3.0) with System Slot left (bottom) Connector for the Fan Tray at the left side Connector for the power supply at the right side Applicable Specifications: PICMG 2.0 R3.0 CPCI Core Specification PICMG 2.01 R2.0 Hot Swap PICMG 2.09 R1.0 System Management Bus PICMG 2.10 R1.0 Keying www.schroff.biz 4 R1.1, April 18, 2011

Product Definition 2.5 Power Supply Hazardous voltage! Parts of the power supply may be exposed with hazardous voltage. Always remove mains/line connector before carry out any assembly work. Caution! Your system has not been provided with a AC power cable. Purchase a AC power cable that is approved for use in your country. The AC power cable must be rated for the product and for the voltage and current marked on the product's electrical ratings label. The voltage and current rating of the cable should be greater than the ratings marked on the product. Power is provided through a 250 W ATX power supply with wide range input. The power supply is located to the right of the card cage behind a perforated front panel. The AC input is via an IEC 320-C14 connector at the back. The mains on/off switch is located at the back close to the AC input connector. With a DC switch at the front you can switch-off the DC outputs of the power supply. 2.5.1 Grounding/Earthing Caution! The unit is designed in accordance with protection class 1! It must therefore be operated with protective earth/gnd connection. Use only a three conductor AC power cable with a protective earth conductor that meets the IEC safety standards! www.schroff.biz 5 R1.1, April 18, 2011

Product Definition 2.5.2 ATX Power Supply Figure 2: ATX Power Supply 10006854 1 ATX Power Supply 4 AC Connector (IEC320-C14) 2 AC Switch 5 DC Switch 3 Fan Table 1: Techn. Data ATX Power Supply Input voltage 90...264 VAC, 120...380 VDC / active PFC Input frequency 47...63 Hz Input current 4 A (115 V) / 2 A (230 V) Output (max) 5 V / 23 A; 3,3 V / 14 A, 12 V / 16 A, -12 V / 0,5 A) Output (min) 5 V / 3 A; 3,3 V / 1 A, 12 V / 2 A, -12 V / 0,1 A) Inrush Current 65/130 A (115/230 VAC) Efficiency >70%, (115 VAC full oad) Overload protection 110...160%, shut down Short circuit protection +3,3 V, +5 V, +12 V, shut down / -5 V, -12 V, +5 VSB, auto recovery Over voltage protection +3,3 V (+3,6...+4,2 V), +5 V (+5,6...+6,6 V), +12 V (13,2...14,6 V) Ripple +3,3 V 60 mv / +5 V 50 mv / +12 V 120 mv / -12 V 120 mv Load regulation +3,3 V ±5% / +5 V ±5% / +12 V ±5% / -12 V ±10% Hold up time >16 msec. Power Good Signal switch-on delay 100...500 msec. Switch-off delay 1msec. Isolation voltage Input / Chassis 3000 VAC for 60 sec. Input / Output 1800 VAC for 60 sec. Leakage current <3,5 ma, 115 VAC / 230 VAC Operating temperature 0...+50 C Derating Power on: +3,3 V: +30 C/14 A, +40 C/12 A, +50 C/10 A Storage temperature -20...+80 C Humidity 20...80% RH, non-condensing MTBF 120.000 h at +50 C, without fan Safety TÜV EN 60950 / UL 60950 EMV CE Fan ball bearing fan, temperature regulated Dimensions (LxBxH) 190 x 100 x 40 mm, ±0,5mm www.schroff.biz 6 R1.1, April 18, 2011

Product Definition 2.6 Cooling Figure 3: Fan Tray 12311802 The CPCI front boards are cooled by forced air convection through a 12 VDC axial fan (140 m³/h (82 cfm)). The operating temperature is from 0 C to 50 C, but note that the power supply starts derating at 30 C. 2.7 Remove/Install Fan Tray The Fan Tray is locked into the chassis by a mini compression latch with indicator red/green. In closed position the indicator shows green, in open position the indicator shows red. Remove Fan Tray: Turn the knob counterclockwise until the indicator shows red. Pull out the Fan Tray: Install Fan Tray: Insert the Fan Tray into the slot Turn the knob clockwise until the Fan Tray is locked into the chassis.(by turning the knob clockwise, the cam is put into the latched position and the green indicator appears. Once latched, a further turning of the knob makes the cam starts its compression feature until the Fan Tray is locked.) www.schroff.biz 7 R1.1, April 18, 2011

Product Definition Figure 4: Airflow 12307800 A Fan Tray with additional Fans for Rear I/O cooling is available on request. Caution! To maintain proper airflow, all open slots must be covered with filler panels. The filler panel should include an airflow baffle that extends to backplane. www.schroff.biz 8 R1.1, April 18, 2011

Installation 3 Installation 3.1 General Installation Guidelines 3.1.1 Unpacking Caution! When opening the shipping carton, use caution to avoid damaging the system. Consider the following when unpacking and storing the system: Leave the system packed until it is needed for immediate installation. After unpacking the system, save and store the packaging material in case the system must be returned. If the packaging is damaged and possible system damage is present, report to the shipper and analyze the damage. 3.1.2 Ensuring Proper Airflow Install the system in an open rack whenever possible. If installation in an enclosed rack is unavoidable, ensure that the rack has adequate ventilation. Maintain ambient airflow to ensure normal operation. If the airflow is blocked or restricted, or if the intake air is too warm, an over temperature condition can occur. Ensure that cables from other equipment do not obstruct the airflow through the systems. Use filler panels to cover all empty chassis slots. The filler panel prevents fan air from escaping out of the front of an open slot. Caution! To maintain proper airflow, all open slots must be covered with filler panels. The filler panel should include an airflow baffle that extends to backplane. www.schroff.biz 9 R1.1, April 18, 2011

Installation 3.2 Rack-Mounting This subrack system can be installed in 19 equipment racks. The rack must be accessible from the front and rear for equipment installation. Mounting Instructions: Ensure that the rack is constructed to support the weight and dimensions of the system. Install any stabilizers that came with your equipment rack before mounting or servicing the system in the rack. Load the rack from the bottom to the top, with the heaviest system at the bottom, avoid uneven mechanical loading of the rack. 3.3 Initial Operation Warning! Voltages over 60 VDC can be present in this equipment. This equipment is intended to be accessed, to be installed and maintained by qualified and trained service personnel only. This eqipment is designed in accordance with protection class 1! It must therefore be operated only with protective GND/earth connection! Ensure that the system has not been damaged during transport, storage or assembly. Check the Protective Earth (PE) resistance, should be < 0,1 Ohm. Switch on the system and check all CPCI voltages directly on the backplane connectors before the board assembly. Note: The ATX power supply requires a minimum load! Plug-in the boards Cover all open Slots with filler panels. www.schroff.biz 10 R1.1, April 18, 2011

Service 4 Service 4.1 Technical support and Return for Service Assistance We generally recommend to return the complete subrack system. For all product returns and support issues, please contact your Schroff sales distributor or www.schroff.biz. We recommend that you save the packing material. Shipping without the original packing material might void the warranty. 4.2 Declaration of Conformity SCHROFF CompactPCI system subracks are developed and manufactured according to EN 60950-1. SCHROFF CompactPCI system subracks are not end-products with independent functionality as described in the definition of the EMC regulations, and therefore a CE marking is not required. However, when CPCI cards are assembled according to specification, the systems fulfill the requirements in accordance with EMC Directive 2004/108/EG and Low-voltage Directive 2006/95/EG. Interference resistance and interference emissions are factors which are heavily influenced by the type and quantity of CPCI cards used in the system assembly. Through the use of high quality line filters and EMC optimized enclosure design, SCHROFF offers CPCI systems which serve as an ideal base for system integrators, which comply with the prescribed limits of EN 6100-6-3 and EN 61000-6-2 The systems are generally equipped with power supplies which possess CE markings in accordance with EN 60950-1, EN 61000-6-3, EN 61000-6-2). Before delivery a high-voltage, protective earth and functionality test is carried out on each individual system. www.schroff.biz 11 R1.1, April 18, 2011

Service 4.3 Scope of Delivery Quantity Description 1 19 subrack, shielded, black powder coated (RAL9005) 1 CPCI backplane (PICMG2.0 R.3.0), 6 slot 6 U 1 Front card cage for max. 4 boards 6 U 160 mm deep IEEE guide rails inc. ESD clips (ESD clip assembled at the right) 1 Rear card cage for max. 4 boards 6 U 80 mm deep IEEE guide rails inc. ESD clips 1 250 W ATX power supply with input range of 100 VAC to 240 VAC with 4 voltages: 3,3 V / 14 A; 5 V / 23 A; 12 V / 16 A; -12 V / 0,5 A) 1 Complete AC/DC cabling 1 DC switch 1 Fan Tray, hot swappable 4.4 Accessories Order No. Description 24579-117 Fan Tray with additional fans for Rear I/O cooling 20848-7xx 34562-8xx Slot covers with front panel and EMC shielding for vacant slots. For dimensions, please see catalogue. Slot covers for vacant slots. For dimensions, please see catalogue. 24579-03x Printed Circuit Board covers (solder side covers). For dimensions, please see catalogue 4.5 Spare Parts On request. www.schroff.biz 12 R1.1, April 18, 2011

Technical Data 5 Technical Data Table 2: Technical Data Dimensions Height 132 mm (3 U) Width 482.80 mm (19 ) Depth (Card cage) 275 mm Depth (Overall with handles) 303 mm Weight Completely assembled 8 kg Power Supply Input Voltage 100 VAC bis 240 VAC Frequency 50 / 60 Hz Power input up to 250 W Cooling 1 x 12 VDC fan 140 m³/h (82 cfm) each, free blow Ambient Temperature Operation +0 C to +50 C Storage -40 C to +85 C Humidity Admissible humidity 30 % to 80 %, non-condensing EMC, fulfils requirements for: Transient Emissions EN 61000-6-3 Interference Resistance EN 61000-6-2 Safety Test voltages according to EN 60950 Input - Output: Input - PE: Output - PE: Output - Output: 4,3 kvdc 2,2 kvdc 0,7 kvdc 0,7 kvdc Shock and vibration: EN 60068-2-6 and EN 60068-2-27 Electromagnetic Shielding Shielding attenuation typ. 40 db at 1 GHz if shielded front panels are used. www.schroff.biz 13 R1.1, April 18, 2011

Dimensions 6 Dimensions Figure 5: Dimensions www.schroff.biz 14 R1.1, April 18, 2011

SCHROFF GMBH www.schroff.biz Langenalberstr. 96-100 Tel.: + 49 (0) 7082 794-0 Fax: +49 (0) 7082 794-200 D-75334 Straubenhardt