U-SERIES SPECIFICATION GUIDE Connectivity with flexibility For more product information visit connectrac.com, call us at 877-480 - 5637 or email us at info@connectrac.com ADA COMPLIANT - U.L. TESTED AND LISTED 2011 STRONG PRODUCTS GROUP, LTD. Connectrac systems are protected by US Patent Nos. 6,844,493 and 6,566,598; others pending.
FOR UNLIMITED CONNECTION POINTS Connectrac s U-Series is a powerful and flexible system that delivers unlimited power/voice/data connections to any room.
U-SERIES INTRODUCTION QUICK-CONNECT POWER FOR INFINITE POSSIBILITIES Ideal for training rooms, classrooms, desks, rows of fitness equipment and more, our U-Series offers unlimited possibilities. This 4-circuit system utilizes quick-connect technology to allow any number of receptacles to be located at any spacing along a cable access spine of any length. The devices are easily rearranged, allowing for infinite possibilities and for changes over time. U-SERIES FEATURES + Ideal for training tables and multiple workstations + Unlimited power/voice/data connection points along wireway + 8-wire, 4-circuit (20-amp) power + Capacity for up to 18 CAT-6 cables (varies by cable mfg.) + Quick-connect, modular power components + Duplex or quad receptacles (NEMA 5-15 std; NEMA 5-20 optional) COMMON SYSTEM FEATURES + Low-profile extruded aluminum wireway + Low-sloping moisture-resistant MDF transition ramps + Installs on concrete slab with no coring or trenching + For power/voice/data/av connectivity + Wireway components field-cut to length Ideal for training tables and multiple, freestanding desks. Unlimited power/voice/data connection points along track + Multiple wireway channels can be ganged for additional capacity + UL and CSA listed; ADA compliant FINISH OPTIONS + Wireway cap available in clear anodized aluminum or multiple powder-coat finishes + Available with a cap that accommodates end-user s carpet strip (Note: this increases height of wireway by.25 )
STANDARD U-SERIES SYSTEM COMPONENTS 4 3 6 7 8 5 1 2 3 NOTE: For assistance with special applications contact Connectrac at 877.480.5637 U-Series wireway systems come as complete kits and include the following components: 1 WIREWAY BOTTOM TRACK 5 U -SERIES RECEPTACLE + Extruded aluminum + Anchors to slab + Available lengths: 48, 96 2 3 4 WIREWAY TOP CAP + Extruded aluminum + Snaps into bottom track + Available lengths: 48, 96 SIDE TRANSITION RAMPS, Quantity 2, each side + Adheres to slab with construction adhesive + Available lengths: 48, 96 END TRANSITION RAMPS + 8-wire, 4-circuit - available as a duplex or quad (NEMA 5-15 standard, NEMA 5-20 optional) + Quick-connect ends snap easily into power entry cable and jumper cables + For detailed receptacle information see page I.18 6 U -SERIES RECEPTACLE COVER + Molded ABS, duplex and quad versions + Provides (2) standard modular furniture-sized knockouts for voice/data/av + Includes (2) voice/data adapter kits see page I.20 7 POWER ENTRY CABLE + 8-wire, 4-circuit power + Standard lengths: 6, 24 + Available in custom lengths 2 2.625 3.1 3.1 7 7 1.5 2.25 + Molded ABS, and MDF + Adheres to slab with construction adhesive 8 QUICK- CONNECT JUMPER CABLE + 8-wire, 4-circuit power + Available in standard and custom lengths + For detailed jumper information see page I.19
HOW TO SPECIFY U-SERIES SAMPLE ORDER: Specify Connectrac s powerful U- Series systems in just three steps. STEP ONE: DESCRIBE WIREWAYS - For each run of Connectrac wireway needed, describe the wireway length, top cap finish selection and any desired options or accessories. RUN 1 2 3 4 5 See next page for options & accessories Create Code for Each Separate Run RUN A U-Series Electrical Code U-Series Length (in inches) Wireway Configuration Top Cap Finish Option/ Accessory Option/ Accessory U-01 240 S ES C90 WCH Option/ Accessory In this example the product codes indicate a U - Series electrical system, 240 in length, standard single-channel configuration, Espresso powder coat finish, with two additional accessory options: 90 degree corner kit and wall channel kit. CONNECTRAC SPECIFICATION : RUN A: U-01 / 240 / S / ES / C90 / WCH Refer to the product codes provided below to specify your Connectrac system. See Options and Accessories on the following page. 1 U-SERIES ELECTRICAL U- 01 8-Wire, 4-Circuit Electrical System; 3+1 (3 shared circuits and 1 dedicated circuit); 2 SYSTEM LENGTH receptacles and power jumpers as selected; 24 quick-connect power entry cable (8-wire, 4- ckt); end transition ramps 48 Total overall length = 4 (48 ); 1-4 (48 ) length of wireway components 96 Total overall length = 8 (96 ); 1-8 (96 ) length of wireway components 144 Total overall length = 12 (144 ); 1-8 (96 ) and 1-4 (48 ) length of wireway components 192 Total overall length = 16 (192 ); 2-8 (96 ) lengths of wireway components - 240 Total overall length = 20 (240 ); 2-8 (96 ) lengths and 1-4 (48 ) length of wireway components 288 Total overall length = 24 (288 ); 3-8 (96 ) lengths of wireway components 336 Total overall length = 28 (336 ); 3-8 (96 ) lengths and 1-4 (48 ) length of wireway components 384 Total overall length = 32 (384 ); 4-8 (96 ) lengths of wireway components 432 Total overall length = 36 (432 ); 4-8 (96 ) lengths and 1-4 (48 ) length of wireway components 480 Total overall length = 40 (480 ); 5-8 (96 ) lengths of wireway components 3 WIREWAY CONFIGURATION S D T W Standard Single-Channel Wireway Double Wireway Channels Triple Wireway Channels Window Wall (ramp on one side only) 4 WIREWAY TOP CAP FINISHES AL GR ES ST CA Clear anodized aluminum finish Graphite powder coat finish Espresso powder coat finish Stone powder coat finish Top cap accommodates customer s carpet strip (adds 1/4 to total height of wireway system) 5 OPTIONS & ACCESSORIES See next page for product codes and descriptions
CONFIGURATION OPTIONS AND ACCESSORIES Customize any Connectrac wireway system using options and accessories listed below. 5 OPTIONS & ACCESSORIES Use the appropriate three-digit product code to specify Connectrac accessories. C45 45 DEGREE CORNER KIT RIB STEEL ROUGH-IN BOX + Available in 45º pre-cut kits + 1 per wireway channel C90 90 DEGREE CORNER KIT + For optional use in new metal stud wall construction 1.375 + Installed prior to gypsum board, it provides an opening for cables to pass through 3.75 2.625 + Available in 90º pre-cut kits + 1 per wireway channel 20 20 20 20 WCH WALL CHANNEL KIT CSP B01 CUSTOM CORNER KIT + Specify angle degree when ordering + 30º minimum and 120º maximum + 1 per wireway channel BASE TRANSITION KIT + Allows cables to leave wireway and enter a mouse hole in the side of the hollow table base 3 + Vertical wireway, surface-mounts to wall to provide path from Connectrac 1.25 system at floor to ceiling above + 12 long COM GRM COMMUNICATIONS KIT + Steel device box allows for extra voice/data/av capacity + 2 openings for up to 8 voice/data ports + 2 voice data adapter plate kits GROMMET 2.125 1.25 6.25 SEN SIDE ENTRY KIT + Allows cables to enter the wireway from the side instead of the end + Snaps into wireway bottom track and allows cables to enter and /or exit wireway 2.625 DOM DOM COVER KIT + Used to transition to Connectrac wireway from poke-through device E01 END TRANSITION RAMPS + Provides a finished end cap to I-NO systems AC1 TELECOM PLATE 10.4 + 1 inline 15 pin HD VGA F/F gender changer + 2 punch down RJ45 18.6 AC2 TELECOM PLATE + 1 inline 15 pin HD VGA + 1 inline 3.5mm audio + 1 punch down RJ45
HOW TO SPECIFY U-SERIES STEP TWO: SELECT RECEPTACLE DEVICES - For each run, select the receptacles devices needed. RUN DEVICE QTY DEVICE QTY DEVICE QTY RUN A R201 2 R202 1 R403 1 In this example the product codes indicate two 15 amp duplex receptacles on circuit 1, one 15 amp duplex receptacle on circuit 2, and one 15 amp quad receptacle on circuit 3. Using the code from step 1, add the code above to continue building the specification code as follows. CONNECTRAC SPECIFICATION : RUN A: U-01 / 240 / S / ES / C90 / WCH R201-2 / R202-1 / R403-1 Refer to the product codes provided below to specify your Connectrac system. DUPLEXES, 15 AMP Includes receptacle cover and 2 voice / data adapter kits Code Description R201 Duplex receptacle, 15A; ckt 1 (both outlets are on the same ckt); shared neutral and ground; NEMA 5-15 R202 Duplex receptacle, 15A; ckt 2 (both outlets are on the same ckt); shared neutral and ground; NEMA 5-15 R203 Duplex receptacle, 15A; ckt 3 (both outlets are on the same ckt); shared neutral and ground; NEMA 5-15 R204 Duplex receptacle, 15A; ckt 4 (both outlets are on the same ckt); dedicated neutral and ground; NEMA 5-15 R205 Duplex receptacle, 15A; ckt 1 (both outlets are on the same ckt); special 3+3+2 wiring scheme; NEMA 5-15 R206 Duplex receptacle, 15A; ckt 2 (both outlets are on the same ckt); special 3+3+2 wiring scheme; NEMA 5-15 R207 Duplex receptacle, 15A; ckt 3 (both outlets are on the same ckt); special 3+3+2 wiring scheme; NEMA 5-15 DUPLEXES, 20 AMP Includes receptacle cover and 2 voice / data adapter kits Code Description R301 Duplex receptacle, 20A; ckt 1 (both outlets are on the same ckt); shared neutral and ground; NEMA 5-20 R302 Duplex receptacle, 20A; ckt 2 (both outlets are on the same ckt); shared neutral and ground; NEMA 5-20 R303 Duplex receptacle, 20A; ckt 3 (both outlets are on the same ckt); shared neutral and ground; NEMA 5-20 R304 Duplex receptacle, 20A; ckt 4 (both outlets are on the same ckt); dedicated neutral and ground; NEMA 5-20 QUADS, 15 AMP Includes receptacle cover and 2 voice / data adapter kits Code Description R401 Quad receptacle, 15A; ckt 1 (3 receptacles are ckt 1 and 1 receptacle is ckt 4, which has a dedicated neutral and ground); NEMA 5-15 R402 Quad receptacle, 15A; ckt 2 (3 receptacles are ckt 2 and 1 receptacle is ckt 4, which has a dedicated neutral and ground); NEMA 5-15 R403 Quad receptacle, 15A; ckt 3 (3 receptacles are ckt 3 and 1 receptacle is ckt 4, which has a dedicated neutral and ground); NEMA 5-15 R404 Quad receptacle, 15A; 2 outlets are ckt 1 and 2 outlets are ckt 2; NEMA 5-15 R405 Quad receptacle, 15A; 2 outlets are ckt 3 and 2 outlets are ckt 4; NEMA 5-15 QUADS, 20 AMP Includes receptacle cover and 2 voice / data adapter kits Code Description R501 Quad receptacle, 20A; ckt 1 (3 receptacles are ckt 1 and 1 receptacle is ckt 4, which has a dedicated neutral and ground); NEMA 5-20 R502 Quad receptacle, 20A; ckt 2 (3 receptacles are ckt 2 and 1 receptacle is ckt 4, which has a dedicated neutral and ground); NEMA 5-20 R503 Quad receptacle, 20A; ckt 3 (3 receptacles are ckt 3 and 1 receptacle is ckt 4, which has a dedicated neutral and ground); NEMA 5-20 R504 Quad receptacle, 20A; 2 outlets are ckt 1 and 2 outlets are ckt 2; NEMA 5-20 R505 Quad receptacle, 20A; 2 outlets are ckt 3 and 2 outlets are ckt 4; NEMA 5-20
HOW TO SPECIFY U-SERIES STEP THREE: SELECT JUMPER CABLES - For each run, select jumper cables based on the on-center spacing of the receptacle device. NOT E: For assistance with non-standard device spacings contact Connectrac at 877-480-5637. RUN JUMPER QTY JUMPER QTY JUMPER QTY RUN A J036 1 J060 1 J072 1 In this example the product codes indicate one 36 jumper, one 60 jumper, and one 72 jumper. Using the codes from step 1 and step 2, add the code above to continue building the specification code as follows. CONNECTRAC SPECIFICATION : RUN A: U-01 / 240 / S / ES / C90 / WCH R201-2 / R202-1 / R403-1 J036-1 / J060-1 / J072-1 Refer to the product codes provided below to specify your Connectrac system. JUMPER CABLES J024 J030 J036 J042 J048 J054 J060 J066 J072 J084 J096 J108 J120 Quick-connect power jumper cable for 24 on-center spacing of receptacle devices; 8-wire, 4-ckt Quick-connect power jumper cable for 30 on-center spacing of receptacle devices; 8-wire, 4-ckt Quick-connect power jumper cable for 36 on-center spacing of receptacle devices; 8-wire, 4-ckt Quick-connect power jumper cable for 42 on-center spacing of receptacle devices; 8-wire, 4-ckt Quick-connect power jumper cable for 48 on-center spacing of receptacle devices; 8-wire, 4-ckt Quick-connect power jumper cable for 54 on-center spacing of receptacle devices; 8-wire, 4-ckt Quick-connect power jumper cable for 60 on-center spacing of receptacle devices; 8-wire, 4-ckt Quick-connect power jumper cable for 66 on-center spacing of receptacle devices; 8-wire, 4-ckt Quick-connect power jumper cable for 72 on-center spacing of receptacle devices; 8-wire, 4-ckt Quick-connect power jumper cable for 84 on-center spacing of receptacle devices; 8-wire, 4-ckt Quick-connect power jumper cable for 96 on-center spacing of receptacle devices; 8-wire, 4-ckt Quick-connect power jumper cable for 108 on-center spacing of receptacle devices; 8-wire, 4-ckt Quick-connect power jumper cable for 120 on-center spacing of receptacle devices; 8-wire, 4-ckt 1.5 2 3.1 7 2.25 2.625 3.1 7 U-SERIES RECEPTACLE - duplex and quad U-SERIES RECEPTACLE COVER - duplex and quad QUICK-CONNECT JUMPER CABLE
ADDITIONAL INFORMATION VOICE / DATA / AV ADAPTER KIT A Assembly Instructions: 1. Select the appropriate adapter [B] from the tree [A] using the chart below. 2. Consult directions for voice / data port [C] and snap into the adapter [B]. 2.75 3. Snap port / adapter assembly into the data window [D] in the orientation shown. 4. Snap complete assembly into any 1.375 x 2.75 knockout [E]. 1.375 NOTE: Connectrac receptacles have openings that accommodate either the provided voice/data adapter kits OR standard modular funiture-sized apdapters made by all voice/data jack manufacturers. The size is standard for modular systems furniture. B C D E ADAPTER OPENING SIZE MANUFACTURER AA.654 x.700 Avaya, AT&T, Lucent Technologies BB.594 x.792 Amp/Tyco, Panduit, Keystone Type, Allen Tel, Leviton CC.594 x.752 Amp/Tyco, Krone, Hubbell DD no opening Blank EE.665 x.930 Ortronics TracJack FF.626 x.660 Panduit Mini-Com Connectors GG.953 diameter Microphone Jack, 3-pin XLR U-SERIES CIRCUIT DIAGRAM CIRCUIT 1 CIRCUIT 2 CIRCUIT 3 CIRCUIT 4 (isolated) I II III IV NEUTRAL-2 NEUTRAL-1 ISOL-GRND GROUND HOT-4 HOT-3 HOT-2 HOT-1 GRAY WHITE GRN-YEL GREEN PINK BLUE RED BLACK 10 gauge ADA COMPLIANT - U.L. TESTED AND LISTED 2011 STRONG PRODUCTS GROUP, LTD. Connectrac systems are protected by US patent nos. 6,844,493 and 6,566,598; others pending.