OMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE The Omega MPP enclosure is based on a 19" frame, with 4 empty module slots for MPP modules. Highly flexible : any mix between twisted pair and optical fiber modules. High density, up to 48 ports per enclosure. Easy to manage : cable guides provide an easy means to secure cables to the frame patch guides allow an orderly arrangement of patchcords Easy to install and modify : all operations are performed at the front side. The Clip-On cable fastener provides fast and reliable cable retention and grounding of twisted pair cables. Comes with marking strips to number and categorise ports.
OMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE Technical Characteristics COMPONENTS MPP Frame Cable guide 19", 3 HU, 4 slots for Omega MPP modules, 12 connections per slot front side connectivity on IDC strips 19", 2 HU, for fixing incoming cables inserted just above or beneath an MPP frame, at the back side Two models : - with tie wraps for securing cable - with Clip-On cable fastener (for T.P. cables) Ordering Codes Empty MPP enclosure ACS-202.125 CABLE GUIDES Cable guide Cable guide with Clip-On EMC Pack ACS-102.130 ACS-109.130 ACS-109.131 Remove the cover of the MPP EMC Pack Insertion of a twisted pair module Insertion of an optical fiber module ALCATEL CABLING SYSTEMS Bd.Paepsemlaan 16-1070 Brussels - Belgium Tel.: 32.2.556.08.50 - Fax: 32.2.556.49.50 DSE-541-0997-V2.0 Subject to change without prior notice.
OMEGA MODULAR PATCH PANEL TWISTED PAIR MODULES & FULLY EQUIPPED ASSEMBLIES The Omega MPP Twisted Pair modules are full Category 5 on all pair combinations. RJ45 (ISO 8877) user connector, screened and unscreened versions. Colour coding in conformity with cable colour coding. Omega Twisted Pair Modules come in several versions : Horizontal cable module for 4 pair FTP/STP/UTP cables Ethernet modules with Telco 50 pin mass termination to active equipment Token Ring modules with Telco 50 pin mass termination to active equipment Easy to install and modify : all operations are performed at the front side electrical connections by colour coded IDC contacts, using a single tool special contacts are provided for termination of the grounding wires on the MPP RJ45 ISO 8877 compliant modules with colour coded T 568B and T 568A pin configuration.
OMEGA MODULAR PATCH PANEL TWISTED PAIR MODULES & FULLY EQUIPPED ASSEMBLIES Ordering Codes FULLY EQUIPPED (48 RJ45 3HU) 48 unscreened RJ45 3HU 48 screened RJ45 3HU ACS-503.124 ACS-503.204 Fully Equipped Unscreened RJ45 patch panel Fully Equipped Screened RJ45 patch panel RJ45 MODULES 12 unscreened RJ45 12 screened RJ45 Top ACS-503.126 ACS-503.226 Bottom ACS-503.127 ACS-503.227 ETHERNET MODULES 12 unscreened RJ45 12 screened RJ45 Unscreened RJ45 module Top ACS-205.505 ACS-205.507 Screened RJ45 module Bottom ACS-205.506 ACS-205.508 TOKEN RING MODULES 12 unscreened RJ45 12 screened RJ45 Top ACS-205.501 ACS-205.503 Bottom ACS-205.502 ACS-205.504 * Remark : Ethernet and Token Ring modules have to be used with a Telco-Telco 50 pin cord (ACS-205.500) Unscreened Token Ring module (front) Telco connector on Token Ring module (rear) ALCATEL CABLING SYSTEMS Bd.Paepsemlaan 16-1070 Brussels - Belgium Tel.: 32.2.556.08.50 - Fax: 32.2.556.49.50 DSE-452-0997-V2.0 Subject to change without prior notice.
OMEGA MODULAR PATCH PANELS CABLE MANAGEMENT ACCESSORIES The Omega series comprises a complete range of Modular Patch Panels. For an orderly installation, Omega offers a full range of cable management accessories : Patch guides allow for an orderly cord storage Blind plates cover unused positions in the cabinet Clip-On cable guide for fast and reliable cable retention and grounding
OMEGA MODULAR PATCH PANELS CABLE MANAGEMENT ACCESSORIES Patch Guide Blind Plate 19", 1 or 2 HU, for orderly cord storage Inserted just above or beneath an MPP Frame, at the front side 19", 2 or 3 HU To cover unused positions in a cabinet Ordering Codes PATCH GUIDE 1 HU 2 HU ACS-202.106 ACS-102.106 BLIND PLATE 2 HU 3 HU ACS-109.202 ACS-109.203 CABLE GUIDES Cable guide Cable guide with Clip-On ACS-102.130 ACS-109.130 Clip-On cable guides are mounted at the back side Patch guides are mounted at the front side, and allow an orderly cord storage ALCATEL CABLING SYSTEMS Bd.Paepsemlaan 16-1070 Brussels - Belgium Tel.: 32.2.556.08.50 - Fax: 32.2.556.49.50 DSE-454-0997-V2.0 Subject to change without prior notice.
OMEGA MODULAR PATCH PANEL OPTICAL FIBER MODULES ST module FDDI module SC module The Omega MPP Optical Fiber modules are versatile, providing backbone and Fiber-to-the-Desk interfaces. Optical Fiber Modules come in several versions : 8 simplex and 6 duplex ST adapters 8 simplex and 6 duplex SC adapters 2 FDDI adapters The modules are adapted to tight buffer fiber cable structures or loose tube cable structures and are supplied with or without internal splice tray. Splice holders for fusion splices available.
OMEGA MODULAR PATCH PANEL OPTICAL FIBER MODULES Ordering Codes OPTICAL FIBER MODULES 8 ST-connector 12 ST-connector 8 SC-connector 12 SC-connector 2 FDDI-connector ACS-202.129 ACS-102.129 ACS-102.229 ACS-102.227 ACS-102.327 Remark : Optical Fiber Modules are provided with a cable guide. Bear in mind to order splice tray, splice holder, etc. separately. Remove the cover of the MPP Insertion of an optical fiber module ALCATEL CABLING SYSTEMS Bd.Paepsemlaan 16-1070 Brussels - Belgium Tel.: 32.2.556.08.50 - Fax: 32.2.556.49.50 DSE-453-0997-V2.0 Subject to change without prior notice.
OMEGA OPTICAL FIBER PATCH PANEL 36 or 60 PORTS Based on a 19 inch, 3HU frame. High density, up to 60 ports per frame (3 HU). Splice trays are organised to match cable structures, around multiples of 12. Cost effective solution. Easy to manage cable guides provide an easy means to secure horizontal cables to the frame patch guides allow an orderly arrangement of patchcords Easy to install and modify : all operations are performed at the front side. Comes with marking strips to number and categorise ports. Adapts to all current types of mechanical and fusion splices. Provides a host of possibilities for preconnectorised or unterminated cables. Access from above or side by extending on drawer guides. Models : 3 HU : for 18 duplex ST adapters for 30 duplex ST adapters for 18 duplex SC adapters for 30 duplex SC adapters for 18 duplex FDDI adapters The patch panels are adapted to tight buffer fiber cable structures or loose tube cable structures and are supplied with or without internal splice tray.
OMEGA OPTICAL FIBER PATCH PANEL 36 or 60 PORTS Technical Performances Frame 19", 3 HU Connections 36/60 single or 18/30 duplex ST and SC connections 18 connections for FDDI connectors Connection method - splicing frontplate with drawer or platform dimensions: 48 x 13 x 40 cm (18.9" x 5.12" x 15.7") weight: 3.7 kg - connectorised cable front plate only /frontplate with drawer or platform dimensions: 48 x13 x 5,5 cm (18.9" x 5.12" x 2.17") weight: 1.2 kg Ordering Codes FRONT PLATE ONLY (for connectorising) for 18 ST duplex adapters (36 ports) ACS-202.180 for 30 ST duplex adapters (60 ports) ACS-203.180 for 18 SC duplex adapters (36 ports) ACS-202.181 for 30 SC duplex adapters (60 ports) ACS-203.181 for 18 FDDI duplex adapters ACS-203.186 FRONT PLATE + DRAWER (splicing/connectorising) for 18 ST duplex adapters (36 ports) ACS-202.184 for 30 ST duplex adapters (60 ports) ACS-202.185 for 18 SC duplex adapters (36 ports) ACS-202.183 for 30 SC duplex adapters (60 ports) ACS-202.187 for 18 FDDI duplex adapters ACS-202.182 FRONT PLATE + PLATFORM (splicing/connectorising) for 18 ST duplex adapters (36 ports) ACS-203.184 for 30 ST duplex adapters (60 ports) ACS-203.185 for 18 SC duplex adapters (36 ports) ACS-203.183 for 30 SC duplex adapters (60 ports) ACS-203.187 for 18 FDDI duplex adapters ACS-203.182 Adapters are to be ordered separately DUPLEX ADAPTERS - MULTIMODE ST-ST duplex ACS-203.123 SC-SC duplex ACS-205.127 ALCATEL CABLING SYSTEMS Bd.Paepsemlaan 16-1070 Brussels - Belgium Tel.: 32.2.556.08.50 - Fax: 32.2.556.49.50 DSE-455-0997-V2.0 Subject to change without prior notice.
OMEGA 1 HU TWISTED PAIR PATCH PANEL WITH INTEGRATED SLIDE MECHANISM The Omega 1 HU Twisted Pair Patch Panel is based on 19" frame dimensions. Easy to manage : the integrated Clip-On cable guide provides fast and reliable cable retention and grounding patch guides allow an orderly arrangement of patchcords Easy to install and modify : all operations are performed at the front side. Comes with marking strips to number and categorise ports. The patch panel is equipped with a sliding mechanism for easy access when mounted into a cabinet. This time saving mechanism facilitates front side termination. RJ45 ISO 8877 compliant modules with colour coded T 568B and T 568A pin configuration.
OMEGA 1 HU TWISTED PAIR PATCH PANEL WITH INTEGRATED SLIDE MECHANISM Technical Characteristics Dimensions Connections Facilities type number Slide mechanism Clip-On cable guide 19", 1 HU, depth 170 mm (6.7") RJ45 / screened & unscreened 24 connections integrated, for easy access integrated, for fast & reliable cable retention Ordering Codes 1 HU full copper patch panel 24 RJ45 unscreened 24 RJ45 screened ACS-500.101 ACS-500.111 ALCATEL CABLING SYSTEMS Bd.Paepsemlaan 16-1070 Brussels - Belgium Tel.: 32.2.556.08.50 - Fax: 32.2.556.49.50 DSE-456-0997-V2.0 Subject to change without prior notice.
OMEGA 1 HU OPTICAL FIBER PATCH PANEL WITH INTEGRATED SLIDE MECHANISM The Omega 1 HU Optical Fibre Patch Panel is based on 19" frame dimensions. The patch panel houses 12 duplex ST, 24 simplex ST or 12 duplex SC connector adapters. Accommodates 2 positions, flush or recessed, for feed through faceplate. Recessed position respects the optical fiber cable bending radius. Easy to manage : cable guides provide an easy means to secure horizontal cables to the frame. Comes with marking strips to number and categorise ports. The patch panel is equipped with a sliding mechanism for easy access when mounted into a cabinet. This time saving mechanism facilitates front side installation. In order to respect bending radius of patchcords, the front connectors can be slided backwards. ST & SC faceplates included.
OMEGA 1 HU OPTICAL FIBER PATCH PANEL WITH INTEGRATED SLIDE MECHANISM Technical Characteristics Dimensions Connections Facilities type number Slide mechanism Cable guide 19", 1 HU, 350 mm simplex ST / duplex ST / duplex SC 12 duplex connections (= 24 simplex) integrated, for easy access integrated, for fast & reliable cable retention Ordering Codes 1 HU optical fiber patch panel including faceplates for ST and SC adapters ACS-441.100 Optical fiber adapters ST Adapter - multimode ST - ST simplex ST - ST duplex SC Adapter - multimode SC - SC duplex ACS-205.123 ACS-203.123 ACS-205.127 ALCATEL CABLING SYSTEMS Bd.Paepsemlaan 16-1070 Brussels - Belgium Tel.: 32.2.556.08.50 - Fax: 32.2.556.49.50 DSE-457-0997-V2.0 Subject to change without prior notice.
EPSILON 1 HU TWISTED PAIR PATCH PANEL WITH INTEGRATED CLIP-ON CABLE FASTENER The Epsilon 1 HU patch panel is a high density 19" housing for 20 Epsilon connectors. The Epsilon connector integrates a high quality Cat.5 RJ45 jack and an IDC connection device. Versions available : unscreened, screened & EMC Epsilon connector (Delta or UL verified). The integrated Clip-On cable fastener provides fast and reliable cable retention and grounding. For more information on the Epsilon connector range, refer to the specific datasheet.
EPSILON 1 HU TWISTED PAIR PATCH PANEL WITH INTEGRATED CLIP-ON CABLE FASTENER Technical Characteristics Dimensions Connections Facilities Ordering Codes type number Clip-On cable guide Blank insert 19" 1 HU, depth 148 mm (5.83") unscreened, screened & EMC Epsilon connectors 20 connections integrated, for fast & reliable cable retention to cover unused port positions 1 HU empty patch panel 1 HU Fully equipped patch panel unscreened screened EMC ACS-410.080 ACS-410.081 ACS-410.082 ACS-410.083 Unscreened Epsilon connector Screened Epsilon connector EMC Epsilon connector Accessories Epsilon termination tool Cable termination comfort tool Dust cap Blank insert ACS-410.010 ACS-410.020 ACS-410.030 ACS-410.090 ACS-410.091 ACS-410.050 ACS-410.060 Epsilon termination tool Cable termination comfort tool ALCATEL CABLING SYSTEMS Bd.Paepsemlaan 16-1070 Brussels - Belgium Tel.: 32.2.556.08.50 - Fax: 32.2.556.49.50 DSE-458-0997-V2.0 Subject to change without prior notice.
OMEGA IDC MODULE AND ACCESSORIES Typical set-up for use of IDC modules in a telephony application OUTLET PABX FTP IDC MPP Telephone patchcord IDC- RJ45
OMEGA IDC MODULE AND ACCESSORIES Ordering Codes IDC MODULE 10 pairs IDC disconnection module ACS-102.137 ACCESSORIES IDC Insertion tool ACS-102.107 IDC 1 pair marking cap, red ACS-201.001 IDC plug red open contacts marking strip ACS-201.002 IDC earthing clamp ACS-201.003 IDC spacer 2.5 mm ACS-201.004 IDC spacer 5.0 mm ACS-201.005 IDC 10 pair disconnection plug ACS-201.027 IDC surge protection (empty) ACS-102.203 IDC surge arresters ACS-103.203 IDC switch-over module ACS-201.028 other accessories available on request Application example ALCATEL CABLING SYSTEMS Bd.Paepsemlaan 16-1070 Brussels - Belgium Tel.: 32.2.556.08.50 - Fax: 32.2.556.49.50 DSE-551-0598-V2.1 Subject to change without prior notice.
OMEGA 19" IDC DISTRIBUTION FRAME One Omega IDC Distribution Frame houses up to 15 disconnection modules for 150 pairs in one 19 3HU location. Sufficient space for overvoltage protection. Front side connections for easy installation. One single insertion tool for all connections. The frontpanel covers all underlying modules and cabling for a homogeneous appearance and orderly installation. Sturdy steel and aluminium profile.
1 6 OMEGA 19" IDC DISTRIBUTION FRAME Technical Characteristics Distribution Frame Connections Weight 19" frame, 3 HU up to 15 Omega IDC disconnection modules, each module equals 10 connections 1.3 kg Ordering Codes Omega IDC distribution frame Omega IDC distribution frame with Clip-On ACS-102.131 ACS-109.132 Mounting of modules into IDC frame Telephone application 7 8 9 0 2 3 4 5 OUTLET PABX FTP IDC MPP patchcord IDC- RJ45 Telephone ALCATEL CABLING SYSTEMS Bd.Paepsemlaan 16-1070 Brussels - Belgium Tel.: 32.2.556.08.50 - Fax: 32.2.556.49.50 DSE-552-0997-V2.0 Subject to change without prior notice.
EPSILON IDC MODULE & ACCESSORIES The Epsilon IDC module is an enhanced version, featuring valuable extras : higher density : the module is smaller than traditional ones. Save half the space for the same amount of connections. front side connectivity for easy access and installation disconnect capabilities integral grounding and screening, a worldwide unique feature, requiring fewer accessories The Epsilon IDC module is suitable for 300 MHz applications. Unique wire management features : integrated wire management channels smart labelling system (side & top) The Epsilon IDC module offers integrated protection modules.
EPSILON IDC MODULE AND ACCESSORIES Ordering Codes 10 pairs Epsilon IDC module Without wire guide channel UTP connecting module (disconnection type) FTP connecting module (disconnection type) STP connecting module (disconnection type) With wire guide channel for jumpers UTP connecting module (disconnection type) FTP connecting module (disconnection type) STP connecting module (disconnection type) Epsilon cable termination tool ACS-250.140 ACS-250.141 ACS-250.142 ACS-250.143 ACS-250.144 ACS-250.145 ACS-410.090 ACCESSORIES For FTP modules 1. Protection cartridge with 250 V surge arresters with short-circuit ACS-250.010 2. Empty protection cartridge ACS-250.000 3. Surge arrester (250 V) with short-circuit ACS-250.020 4. Surge arresters insertion tool ACS-250.040 5. Surge arresters extraction tool ACS-250.041 For STP modules 6. Surge arrester with short-circuit, PTC and varistor ACS-250.030 For all modules 7. Black cut plug ACS-250.050 8. Label holder ACS-250.060 9. Half cap ACS-250.200 10. Label for half cap ACS-250.201 11. Black identification plug (for pairs) ACS-250.080 Compatibility quide disconnecting modules Compability quide UTP FTP STP Accessories ACS-250.140, ACS-250.143 ACS-250.141, ACS-250.144 ACS-250.142, ACS-250.145 10 pair protection cartridge (ACS-205.010) Individual protection (ACS-205.030) Integrated earthing pin(acs-205.010) Disconnecting plug (ACS-205.050) Half cap (ACS-205.200) Identification plug (ACS-205.080) Unshielded patch cord Shielded patch cord -- -- 0 X X X X -- X -- 2 X X X X -- -- X 2 X X X -- X ALCATEL CABLING SYSTEMS Bd.Paepsemlaan 16-1070 Brussels - Belgium Tel.: 32.2.556.08.50 - Fax: 32.2.556.49.50 DSE-553-0598-V2.1 Subject to change without prior notice.
EPSILON 19" IDC DISTRIBUTION FRAME For 14 Epsilon IDC modules For 21 Epsilon IDC modules The Epsilon IDC module frame is a high density 19" housing. The Epsilon IDC module offers many extra features : higher density : the module is smaller than traditional ones. front side connectivity for easy access and installation disconnect capabilities integral grounding and screening, a worldwide unique feature, requiring fewer accessories integrated wire management channels smart labelling system (side & top) integrated protection modules Comes fully prepared with all installation accessories. Modules are supplied separately.
EPSILON 19" IDC DISTRIBUTION FRAME Technical Characteristics Distribution Frame Connections Weight 19" frame, 3 HU up to 21 Epsilon IDC connection modules, each module equals 10 connections 1.3 kg Ordering Codes Epsilon IDC Distribution frame for 14 IDC modules for 21 IDC modules Epsilon IDC modules & Accessories ACS-250.220 ACS-250.230 see separate datasheet Accessories Epsilon termination tool ACS-410.090 ALCATEL CABLING SYSTEMS Bd.Paepsemlaan 16-1070 Brussels - Belgium Tel.: 32.2.556.08.50 - Fax: 32.2.556.49.50 DSE-554-0997-V2.0 Subject to change without prior notice.
EPSILON IDC WALL MOUNTING FRAME The Epsilon IDC wall mounting frames are made of several U-shaped aluminium rails and rings for horizontal and vertical jumpers. They can be wall mounted or fixed to the floor. The Epsilon IDC module offers many extra features : higher density : the module is smaller than traditional ones. Save half the space for the same amount of connections. front side connectivity for easy access and installation disconnect capabilities integral grounding and screening, a worldwide unique feature, requiring fewer accessories integrated wire management channels smart labelling system (side & top) integrated protection modules Comes fully prepared with all installation accessories. Modules are supplied separately.
EPSILON IDC WALL MOUNTING FRAME Technical Characteristics Frame Connections Weight 17 mm pitch, 2020 mm high up to 100 x 10 pair IDC modules 1.3 kg Ordering Codes Frame with 2 rails 2 x 18 Epsilon modules, H 310 mm ACS-250.090 2 x 28 Epsilon modules, H 480 mm ACS-250.091 2 x 41 Epsilon modules, H 700 mm ACS-250.092 2 x 65 Epsilon modules, H 1100 mm ACS-250.093 Wall Box with 2 rails - up to 10 Epsilon modules (10 to 100 pairs) ACS-250.120 - up to 20 Epsilon modules (110 to 200 pairs) ACS-250.130 Extension frame ACS-250.110 2 frames MDF ACS-250.100 3 frames MDF ACS-250.101 4 frames MDF ACS-250.102 5 frames MDF ACS-250.103 6 frames MDF ACS-250.104 Example : for an 11 frame MDF, you will need one 5 frame MDF and one 6 frame MDF Accessories Epsilon termination tool ACS-410.090 ALCATEL CABLING SYSTEMS Bd.Paepsemlaan 16-1070 Brussels - Belgium Tel.: 32.2.556.08.50 - Fax: 32.2.556.49.50 DSE-555-0598-V2.1 Subject to change without prior notice.
LAMBDA 1 HU OPTICAL FIBER & TWISTED PAIR PATCH PANELS WITH INTEGRATED SLIDE MECHANISM For Lambda twisted pair, optical fiber and hybrid connector modules. The Lambda range is a highly modular set of connectors, surface mount enclosures and patch panels. The Lambda patch panel is a 1 HU full metal housing. The Lambda patch panel range accommodates all Lambda connector modules with 3 and 6 connections (see specific datasheet). All modules offer an integrated cable fastener (tie-wrap) mechanism. Installation of cables is performed outside of enclosure or patch panel for easy access. Cabled modules snap into enclosure or patch panel through a 'Slide & Click' movement. No tools required. The patch panel is equipped with a sliding mechanism for easy access when mounted into a cabinet. This time saving mechanism facilitates front side installation. For copper cables, the Clip-On cable guide provides fast and easy cable retention and grounding.
LAMBDA 1 HU OPTICAL FIBER & TWISTED PAIR PATCH PANEL WITH INTEGRATED SLIDE MECHANISM Technical Characteristics Dimensions Connections Facilities type number Slide mechanism Clip-On cable guide 19", 1 HU Lambda connector modules with 3 and 6 connectors 24 connections, mixed copper and optical fiber integrated, for easy access integrated, for fast & reliable cable retention Ordering Codes Lambda 1 HU patch panel ACS-441.024 Lambda 40 connector modules Modules with 2 & 3 connectors Refer to the specific datasheet Module with 3 duplex SC connectors (*) ACS-440.062 Module with 6 simplex ST connectors (*) ACS-440.063 *These modules have been designed specifically for this type of patch panel and do not fit in the Lambda enclosures, as they are deeper because of the integrated splice holder facility. Application example 6 x simplex ST ACS-440.063 3 x duplex SC ACS-440.062 ALCATEL CABLING SYSTEMS Bd.Paepsemlaan 16-1070 Brussels - Belgium Tel.: 32.2.556.08.50 - Fax: 32.2.556.49.50 DSE-556-0598-V2.1 Subject to change without prior notice.
OPTICAL FIBER TECHNOLOGY INTRODUCTION & PRODUCT OVERVIEW Patch panels are supplied without adapters 2) OPEN THE FIRST SPLICE TRAY Patch panels come in three kinds : front plate only front plate + platform front plate + drawer 1) PRESS AND HOLD Splice trays can be stacked by means of spacers Optical Fiber installation requires a choice between two cable termination techniques : direct connectorising onto the optical fiber cable, or the use of splicing techniques. On site connector mounting Connector mounting typically includes cable stripping, preparation of the fibers and the use of Hot Melt connectors, connector mounting, drying, polishing and testing. Installation practice is being facilitated, amongst others by using Hot Melt connectors. On site splicing Taking into account the present state of the art in splicing techniques, on site splicing will be the more economical solution although it may take more time. Pigtails are manufactured and verified in laboratory conditions. On site these pigtails are mounted onto the cable using high quality mechanical or fusion splices, guaranteeing perfect quality. For both techniques, Alcatel Cabling Systems offers a full range of products. An overview is found overleaf.
OPTICAL FIBER TECHNOLOGY INTRODUCTION & PRODUCT OVERVIEW Front plate only : direct connector mounting Front plate + drawer/platfor:m : direct connector mounting or splicing On site connector mounting : product overview On site splicing : product overview Patch panel : front plate only type / front plate +drawer or platform (*) Adapters (to be mounted onto the front plate) ST Hot Melt multimode connectors Universal Optical Fiber Splice Tray & spacers Flexible tube for optical fiber cable Splice holders Universal Hot Melt tool kit Polishing : choice between Hand polishing paper Polishing machine kit 1. Mechanical splice Patch panel : front plate + platform or drawer type Adapters (to be mounted onto the front plate) Pigtails Universal Optical Fiber Splice Trays & spacers Flexible tube for optical fiber cable Splice holders Cable mounting tube Mechanical splices (250/900 nm) Mechanical splice tool kit (*) 'Front plate only' types of patch panels are only used for connectorising. Platform or drawer types are preferred. Cable modules and fibers are to be protected using flexible tubes. Refer to the specific datasheets for product descriptions. 2. Fusion splice Patch panel : front plate + platform or drawer type Adapters (to be mounted onto the front plate) Pigtails Universal Optical Fiber Splice Trays & spacers Fusion Splice holders Flexible tube for optical fiber cable Fusion splice protection sleeves Fusion splice tool kit DSE-701-0997-V2.0 Subject to change without prior notice.
OPTICAL FIBER CONNECTORISING Optical Fiber connectorising is one of the cable termination techniques. The other possibility is splicing by means of pigtails. The connectorising technique requires the following installation material : Hot Melt connectors (epoxy connector versions available on request) universal splice trays and spacers splice holders tooling for mounting : Universal Hot Melt tool kit tooling for polishing : Hand polishing paper Polishing machine kit
OPTICAL FIBER CONNECTORISING Ordering Codes ST HOT MELT CONNECTORS ST Hot Melt connector multimode ST Hot Melt Push Pull connector multimode ST Hot Melt connector singlemode (126µm) ACS-205.121 ACS-205.122 available on request SC HOT MELT CONNECTORS SC Hot Melt connector multimode SC Hot Melt connector singlemode (126µm) ACS-102.462 available on request FDDI CONNECTOR FDDI connector available on request EPOXY CONNECTORS Epoxy connectors available on request TOOLING FOR MOUNTING CONNECTORS Universal Hot Melt tool kit (220 V) ACS-102.114 TOOLING FOR POLISHING Hand polishing paper Polishing machine (220 V) Machine polishing paper ACS-102.108 ACS-102.112 ACS-102.109 ADAPTERS Please refer to the separate datasheet on Optical Fiber Adapters CONSUMABLES Flexible tube for optical fiber cable ( ø 1.5 mm) Flexible tube for optical fiber cable ( ø 4 mm) Sealing plug for unused ST connectors ST push pull duplex coupler clip SC duplex coupler clip ACS-108.001 ACS-108.002 ACS-108.004 ACS-205.126 ACS-205.129 ALCATEL CABLING SYSTEMS Bd.Paepsemlaan 16-1070 Brussels - Belgium Tel.: 32.2.556.08.50 - Fax: 32.2.556.49.50 DSE-703-0598-V2.1 Subject to change without prior notice.
OPTICAL FIBER SPLICING Optical Fiber splicing is one of the cable termination techniques. The other possibility is direct connectorising or connector mounting onto the cable. The splicing technique requires the following installation material : pigtails universal splice trays and spacers splices : mechanical splices require : mechanical splices 250/900 µm splice holders for ATI splices fusion splices require : fusion splice protection sleeves splice holders for fusion splices adapters to be integrated in outlets and patch panels (see separate datasheet) tooling : mechanical splice tool kit, including fiber cleaver fusion splice tool kit Optical fiber pigtails are required for splicing onto main cables within patch panels Available for all industry standard ST and SC connectors, multimode and monomode. Standard 62.5/125/900 micron or 50/125/900 micron fibers : 50/125µm fibers comply with CCITT G 651 and IEC 793/2 specifications. 62.5/125µm fibers comply with IEC 793/2 and FDDI specifications. High connector retention force guarantees reliable and lasting connector attachment.
OPTICAL FIBER SPLICING Ordering Codes PIGTAILS ST 62.5/125/900 µm ST 50/125/900 µm SC 62.5/125/900 µm SC 50/125/900 µm ACS-102.122 ACS-900.139 ACS-102.222 ACS-900.138 ACS-102.122 UNIVERSAL SPLICE TRAY 1X Universal splice tray Spacer for 3 splice trays ACS-102.138 ACS-102.139 ACS-102.138 3 X ACS-102.139 MECHANICAL SPLICE Mechanical Splice 250/900 µm Splice holder for 12 ATI splices Mechanical Splice tool kit ACS-103.125 ACS-103.140 ACS-103.126 FUSION SPLICE Splice holder for fusion splices Fusion splice protection sleeve Fusion Splice tool kit ACS-102.140 ACS-103.122 On request ADAPTERS ACS-103.140 Please refer to the separate datasheet on Optical Fiber Adapters ACS-102.140 CONSUMABLES Flexible tube for optical fiber cable ( ø 1.5 mm) Flexible tube for optical fiber cable ( ø 4 mm) Sealing plug for unused ST connectors ST push pull duplex coupler clip SC duplex coupler clip ACS-108.001 ACS-108.002 ACS-108.004 ACS-205.126 ACS-205.129 Pigtail Application CABLE SPLICE PROTECTOR PIGTAIL ADAPTER Splicing technique requires pigtails to be spliced onto the optical fiber cable. The splices are stored in a splice holder and fixed onto the splice tray, which is placed on the platform or drawer. Splice trays can be stacked using spacers. CORD ALCATEL CABLING SYSTEMS Bd.Paepsemlaan 16-1070 Brussels - Belgium Tel.: 32.2.556.08.50 - Fax: 32.2.556.49.50 DSE-704-0997-V2.0 Subject to change without prior notice.
OPTICAL FIBER ADAPTERS Optical Fiber adapters are mechanical devices which allow two connectors to be coupled. They are to be used in conjunction with optical fiber connector modules, outlets and patch panels. Adapters come in several versions : identical connections (e.g. ST to ST) hybrid connections (e.g. ST to SC) simplex or duplex with fixed attenuation multimode and singlemode Simplex adapters are preferred to be used for the Alcatel outlets. Duplex adapters are preferred in patch panel faceplates.
OPTICAL FIBER ADAPTERS Ordering Codes ST Adapter - multimode ST - ST simplex ST - ST duplex ACS-205.123 ACS-203.123 ACS-205.123 SC Adapter - multimode SC - SC simplex SC - SC duplex ACS-205.125 ACS-205.127 ACS-205.125 ACS-205.127 ST - SC Adapter - multimode ST - SC duplex ACS-205.131 FDDI - ST Adapter - multimode FDDI - ST duplex ACS-205.124 ACS-205.124 Adapter with Fixed Attenuation Singlemode & Multimode use ST simplex - 5 db attenuation ACS-205.132 ST simplex - 10 db attenuation ACS-205.133 SC simplex - 5 db attenuation ACS-205.142 SC simplex - 10 db attenuation ACS-205.143 Singlemode adapters Available on request ALCATEL CABLING SYSTEMS Bd.Paepsemlaan 16-1070 Brussels - Belgium Tel.: 32.2.556.08.50 - Fax: 32.2.556.49.50 DSE-702-0997-V2.0 Subject to change without prior notice.