Classroom WiFi Network Infrastructure Plan

Similar documents
Tarleton State University. Specifications

Government of Prince Edward Island Structured Cabling Standards August 24, 2009

Office of the Chief Information Officer Technical Note: IT-960-TN14 Effective: 05/25/2006 Last Revised: 02/17/2012 Issuing Office: OCIO

Computer Network Design Guide Existing Systems 1 / 6

<add school name here> School Equipment Upgrade and Cabling Project Template <date>

Data Cabling / Low Voltage Technology Specifications

f) Telecommunications Equipment Rooms

SPOS (Station Point of Sale) 200. SFTP (Station Fare Transaction Processor) 35. CQD (Card Query Device) 35. HCR (Handheld Card Reader) Cradles 120

The University of Texas at Austin July 30, 2014 SECTION COMMUNICATIONS TERMINATION BLOCKS AND PATCH PANELS

Communication

Network Construction Guide Specification Telecommunications Infrastructure Standards V 2.6

SECTION COMMON WORK RESULTS FOR COMMUNICATIONS

COMMON WORK RESULTS FOR COMMUNICATIONS

v2.5 was updated May 10, v2.6 is an updated copy from March 1, 2017.

Cabling to support ac and beyond. Nate Herring Sr. Product Manager Hubbell Premise Wiring

Addendum No. 1 January 7, 2015

Communications. UNM IT/Telecommunications Guide Specification Communications

Industry Standards in ICT Enabled Projects Reading and Applying the "Fine Print"

TIA/EIA 568A Sub-system HORIZONTAL CABLING

A. System design shall be completed by a Registered Communications Distribution Designer (RCDD).

Los Angeles Community College District Design Standards

USB 2.0 CAT5E/6/7 EXTENDER

Optimization and Speed: Two Critical Standards Enabling Next Generation Networks. Stephanie Montgomery, TIA Brett Lane, Panduit

COMPUTER NETWORK WIRING SYSTEMS FOR PLCs

Wirewerks Datacenters Becoming More Common in Our Workplace, Next Step Solution

SPECIFICATION STANDARD COPPER RISER AND INTRABUILDING CABLING

NZQA registered unit standard version 2 Page 1 of 7. Demonstrate basic knowledge of electronic security data protocols and cabling

Cabling a Data Center to TIA-942 Standard

Accessory Guide Indoor AP Accessories

Leveraging the Structured Cabling System for Security Applications. Mark Dearing, RCDD Leviton Network Solutions

UNIVERSITY OF CALICUT (Purchase Division)

ANSI/TIA/EIA-568-B Cabling Standard

INTERIM COMMUNICATIONS INFRASTRUCTURE PLANNING GUIDELINES

SYSTIMAX GigaSPEED Xpress Solution Design Guidelines

Accessory Guide ZoneFlex Indoor AP Accessories

BLACKBOX NETWORK SERVICES. one source for worldwide infrastructure services

ANSI/TIA/EIA-568-B Cabling Standard

The Power of PoE: Converging Power and Control of Intelligent Devices

Wireless Area Controller (WAC50) i. Installation Instructions

Cabling Infrastructure

PoP ROOM: INSIDE AND OUTSIDE PLANT RULES & REGULATIONS

USER MANUAL MODEL 570/ Base-T (CAT-5) Surge Protectors SALES OFFICE (301) TECHNICAL SUPPORT (301)

Standards Update. Mylaraiah J N, RCDD Member, BICSI India Steering Committee

Hypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :

Connectix Specification Guide for Category 6 U/UTP and Optical Fibre Cabling System Architecture

ANSI/BICSI , Information Transport Systems Design Standard for K-12 Educational Institutions

Panduit PreConfigured Industrial Distribution Frame (IDF) Installation Instructions Part Numbers ZDF48-RA and ZDF48-EA ZDF48-6RA and ZDF48-6EA

Wireless Area Controller (WAC60)

INSTALLATION INSTRUCTIONS FOR THE BV10-100/1000

Target Interface / Construction Compliance Inspection Checklist

Anticipating Cat 8 Agenda. Cat 8 Overview Cat 8 Customer Design Considerations Testing Procedures and Standards

COUNTY OF SAN JOAQUIN

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

E. Numbering and Labeling Pathway components. In general, pathway components are not labeled.

The six major components of a structured wiring system are:

Cabling Infrastructure

Siemon PON Fiber Cabling Solutions

Cabling to Maximize n Wireless Performance

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

Accessory Guide Indoor AP Accessories

LACCD IT Design Standards

Copper Cabling from 10G to 400G, and back down to 10Mbps, but on 1 pair only

Section COMMUNICATION EQUIPMENT ROOM FITTINGS. Section Communications Cable Management and Ladder Rack

Telecommunications Structured Cabling Systems

DESIGN GUIDELINES. Building Circulation

Cisco ONS CL Shelf Assembly Hardware

Anixter Standards Reference Guide

210 SERIES WEBSMART NETWORK SWITCHES Quick Start Guide AN-210-SW-F/R-8-POE AN-210-SW-F/R-16-POE AN-210-SW-F/R-24-POE AN-210-SW-F-48-POE

The Real Impact of High Power PoE on Your IP Network

With Great Power Over Ethernet Comes Great Responsibility PRESENTED BY Bob Crain

ANSI/TIA-568-C Cat 6A Field Test Specifications

Implementation considerations for cabling supporting remote powering

PS3108C. 8-Port Web Smart GbE PoE+ Switch QUICK INSTALLATION GUIDE

University of Arkansas at Little Rock

Ethernet Test Access Panel (ETAP) User Manual

Power Over Ethernet with Panduit Copper Cabling. How To Create More Meaningful Connections With The Highest Performing Infrastructure

Bonding and grounding NETCONNECT copper cabling systems

DOCKING STATION SPECIFICATIONS

USER MANUAL MODEL 570-R8/570-R R8/580-R Base-T (CAT-5) Surge Protectors

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

XBR V4 INSTALLATION AND USER GUIDE

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

Data Center Design and the ANSI/TIA-942 Standard

Newark, Delaware Architectural Engineering Senior Thesis Portfolio

Installation Guide IP-DECT Base Station and IP-DECT Gateway

Physical Layer changes coming to a network near you, soon! Wayne Allen Regional Marketing Engineer Fluke Networks

History of Standards

Standards Update. by Paul Kish NORDX/CDT

IoT and Intelligent Building Challenges in ICT

Huron School District Request for Proposal

Cable Sharing: An ANSI & ISO Recognized Solution for High Density, Low-Speed Applications. Robert Y. Faber Jr., RCDD/NTS.

USER MANUAL MODEL 571/ Base-T (CAT-5) Surge Protectors. SALES OFFICE (301) TECHNICAL SUPPORT (301)

InstaPATCH Cu Cabling Solutions for Data Centers

Huron School District Request for Proposal

Atras Network Communications

SECTION TELECOMMUNICATIONS TESTING AND DOCUMENTATION

New Standardized Cabling Options for NBASE-T Devices

Hardware overview. Package contents MSM710, documentation, power supply, self-adhesive rubber feet.

With the publication. Make the right connection: Bonding a shielded system. installation

USB 3.1 CAT6A/7 EXTENDER

Transcription:

Seattle Archdiocese Office for Catholic Schools Design for Classroom WiFi Network Modernization Guidelines for IT Physical Infrastructure Design and Specifications This document provides guidelines to school technology support staff responsible for developing and supervising the design and installation of new classroom computer/network cabling systems. Contents: A. Standard floor rack network equipment rack and cabling/power components B: Wall mount rack with equipment profile C. Permanent Link Diagram of the cabling physical path to the classroom access point D. Specification and Standards: IEEE and BCSI E. Copper Cert Report: Example of the post-installation cabling certification report F. Wall Mount AP: Plan to attach wireless access point to a wall Engineer: T. E. O Callahan OCS Technology Strategy and Planning March 7, 08 Classroom WiFi Network Infrastructure Plan

Typical 9 Inch Floor Mount Rack Profile Power cords routed on back side on vertical wire manager 4 to 6 inch vertical wire management Meraki MX5 48 port PoE+ Switch RU Router/Firewall WTI MPC-6H-. 48 Port copper patch panels label with jack numbers. U Horizontal wire managers D-Ring Panel 5 rings 55833- Leviton Opt-X 500i SDX 5RUL-CMT 3. 48 port switch 4. Harness cables or patch cords secured with velcro in 6 cable bundles Cable Mgmt Ring Part #: CS 558334-4 to 6 inch vertical wire management Engineer s Notes:. The switch is the first and closest equipment component to the patch panel.. The vertical and horizontal cable management must be place to provide a path to route the patch cords between equipment. The patch cords must be appropriately sized. 3ft Mini Cat6 are optimal. ft is the minimum length. 3. The patch cords must not be routed directly down across equipment from the patch panel. Power redundancy design: UPS or Power Strip (WTI MPC) with dual power inputs. Two () L5-0 power receptacles on separate 0 volt, 0 amp circuits. Note: These are locking style receptacles. Best Practice: Use L5-0 cords (locking style preferred ) and 5-0R receptacles Power Strip TrippLite PDU RS5-RA Outlets UPS APC Smart-UPS SC450RMU TrippLite PDU Part #: RS5-RA Outlets 0 volt, 0 amp power strips Example: CHATSWORTH - 57003-703 Typical Floor Mount Rack Example SITE: Typical Rack BLDG: DATE: 3/0/7 3 SHEET SIZE: x8.5 DATE: 3/7/5 SHEET: of

Wall Mount Rack Examples and Equipment Profiles Hoffman Wall Mount Rack RU Part #: E9FMWu0 Starcom 4RU Wall Mount Rack Part #: RK49WALLV Hoffman Wall Mount Rack Equipment Position and Cable Management Example Meraki MX5 48 port PoE+ Switch RU Router/Firewall TrippLite PDU RS5-RA Outlets Hoffman Wall Mount Rack RU BLDG: DATE: 3/7/8 3 SHEET SIZE: x8.5 DATE: 3/7/5 SHEET: of

End to End Classroom Cable Path 9 inch rack or cabinet MDF/IDF Service Loop Wireless Access Point (WAP) Permanent Link Cat6 Patch Cable ~- ft Surface Mounted RJ-45 Biscuit Figure : Drop ceiling WAP mounting Permanent Link placed into a raceway/conduit to protect exposed cables Figure : Beam ceiling WAP mounting APC Smart-UPS SC450RMU TrippLite PDU RS5-RA Outlets Cabling Design for Classroom Wireless Access Points General Template BLDG: All DATE: 3/7/7 3 SHEET SIZE: x8.5 DATE: 3/7/7 SHEET: of

. Bids shall provide detail on type of cabling. Include components necessary for full operation including installation. The attached diagram is guidance for a rack design. The components include: cabling, conduit, cable ways, race way, jacks, ground, busbar, patch panel, racks, cable management.. Dual 4 pair station wire will be terminated on an un-keyed 8 pin modular jack and shall conform to the appropriate performance specifications as set forth in EIA/TIA 568B or the equivalent. 3. All jacks shall be labeled with its appropriate assigned room number. 4. The number and location of jacks will be determined during a site visit. The estimated number is 5 jacks. 5. Installed equipment labels on installed items, such as access points and switches and other non-cable items, must include the Funding Request Number (FRN). 6. The wiring for wireless access points shall provide for mounting the access point in the middle of the classroom ceiling using the manufacturer specified mounting brackets. 7. The number of feet of cabling drops is an estimate only and the selected solution may differ from the estimation by a considerable amount. 8. Horizontal wiring shall be plenum rated. 9. Wires should run in a straight line at 90-degree angles to the building structure and be formed properly. Wire clamps/rings shall be placed 4 horizontally or 8 vertically. Cable/wire tie wraps or Velcro straps will be every 6 horizontally or 8 vertically. The installed cable must not be under tension greater than 5 pounds (II kg). This will be visually apparent by the sag of the cables. 0. UTP cable shall be installed per the ANSI/TIA/EIA-569 EMI separation distances.. Cables shall not be laid directly on ceiling tiles, HVAC ducts or attach to sprinkler pipes, electrical conduit, ceiling tile hangers or any other structure not specifically intended for communications support.. The design/installation shall provide a minimum of 5ft (4m) service loop be provided in the horizontal permanent link to enable future patch panel or drop location move requirements. 4. The design/installation contractor must meet and comply with federal, state, and local codes and regulations including telecommunications industry standards: ANSI/BICSI, TIA, NEC/NFPA, IEEE. This is an example of such standards: ANSI/BICSI: ANSI/BICSI 00-04 - Data Center Design & Implementation Best Practices ANSI/BICSI 003-04 - Building Information Modeling (BIM) Practices for Information Technology Systems BICSI: Information Technology Systems Installation Methods Manual - 6th Edition Outside Plant Design Reference Manual - 5th Edition Telecommunications Distribution Methods Manual - 3th Edition TIA: TIA-568-C.0 - Aug 4, 0 - Generic Telecommunications Cabling for Customer Premises TIA-568-C. - May 3, 0 - Commercial Building Telecommunications Cabling Standard TIA-568-C. - Nov 7, 04 - Balanced Twisted-pair Telecommunications Cabling and Components Standards TIA-568-C.3 - Oct 3, 0 - Optical Fiber Cabling Components Standard TIA-569 Rev B - Mar, 05 - Telecommunications Pathways and Spaces TIA-606 Rev B - Jun, 0 - Administration Standard for Telecommunications Infrastructure TIA-607 Rev B - Aug, 03 - Generic Telecommunications Bonding and Grounding (Earthing) for Customer Premises TIA-758 Rev B - Mar 7, 0 - Customer-owned Outside Plant Telecommunications Infrastructure Standard TIA-86 Rev A - Mar 30, 0 - Building Automation Systems Cabling Standard TIA-94 Rev A - Mar 04 - Telecommunications Infrastructure Standard for Data Centers TIA-005 Rev A - Jan 7, 05 - Telecommunications Standard for Industrial Premises TSB-6 Rev A - Nov, 03 - Telecommunications Cabling Guidelines for Wireless Access Points IEEE: IEEE 80.3af-003: Power over Ethernet (PoE). IEEE 80.3at-009: Power over Ethernet Plus (PoE Plus) IEEE 80.-0: Wireless Networking IEEE 80.3an-006: 0GBASE-T 0 Gbps (50 Mbps) Ethernet over Unshielded Twisted Pair (UTP) IEEE 80.3bz: NBASE-T NFPA: NFPA 70 - National Electrical Code - 04 Edition NFPA 70E - Standard for Electrical Safety in the Workplace - 05 Edition 3. Wiring/cabling and equipment must be properly installed and tested. Installer shall provide cabling test reports. Note: Cat 5e cabling must meet or exceed Cat 5e specifications at 00Mhz for near end/far end cross talk per IEEE 80.3 000BASE-T (Gigabit Ethernet) standards. See Appendix A for an example. Post Installation: Primary Contractor will email cabling test reports in a PDF format (Item 3) to tom.ocallahan@seattlearch.org within 0 days of completion. Cabling Specifications and Standards General Description BLDG: DATE: 3/7/7 3 SHEET SIZE: x8.5 DATE: 3/7/7 SHEET: of

Appendix A: Copper Certification Report Example

Access Point is mounted to face classroom floor Meraki MR4 Wall Mounting Parts List: A. 5 inch Stanley Corner Iron (must align holes with MR4 E mounts) B. M4- pan head machine screws (qty ) C. M4 Hex Nut (qty ) D. 3x6x flat washer (qty ) Use the MR4 E mounting cutouts/holes, secure access point to mount with a screw. Note: Access points must not be mounted to the side of the wall Plan to Wall Mount MR4 Access Points SITE: BLDG: DATE: /3/7 3 SHEET SIZE: x8.5 DATE: 3/7/5 SHEET: of

General Template BLDG: All DATE: 3/7/7 3 SHEET SIZE: x8.5 DATE: 3/7/7 SHEET: of