Cisco Network Convergence System 2000 Series Passive Auxiliary Modules

Similar documents
Cisco Network Convergence System 2000 ROADM and Amplifier Line Cards

The Cisco NCS 1001 system provides the following hardware benefits (also see Figure 2):

Asynchronous Terminal Server Interface Modules for Cisco 4000 Series Integrated Services Routers

Cisco ONS Port CFP Line Card

Cisco 100GBASE QSFP-100G Modules

Cisco 100GBASE QSFP-100G Modules

Enhanced C-Band Optical Amplifier for the Cisco ONS Multiservice Transport Platform

Cisco Nexus 7700 Switches Data Sheet

Cisco 25GBASE SFP28 Modules

Cisco Network Convergence System 5500 Series

Cisco Network Convergence System 2000 Series

Cisco cbr-8 Converged Cable Access Router Supervisor 250G

Cisco 40GBASE QSFP Modules

Cisco 4-Port Clear Channel T1/E1 High-Speed WAN Interface Card

Cisco NCS Gbps DWDM Line Card with Soft Decision FEC

Cisco Nexus 9500 R-Series

Cisco Nexus 7000 Switches Second-Generation Supervisor Modules Data Sheet

Cisco Nexus 7000 F3-Series 6-Port 100 Gigabit Ethernet Module

Cisco Nexus 9500 Platform Switches for Cisco Application Centric Infrastructure

Cisco Secure Network Server

Cisco Secure Network Server

Cisco Nexus 9500 Platform Switches for Cisco Application Centric Infrastructure

Cisco Nexus 7000 Series.

Cisco ASR 9000 Series 4-Port and 8-Port 100 Gigabit Ethernet Line Cards

Cisco Firepower 9300 Security Appliance

Cisco Network Convergence System 520 Ethernet Access Device

Cisco Nexus 7000 Series

Cisco NCS 5011 Router Data Sheet

Cisco Nexus 7000 Series Supervisor Module

ExtremeSwitching TM. 100Gb Ethernet QSFP28 Transceivers and Cables. Product Overview. Data Sheet. Highlights. 100Gb Ethernet QSFP28 SR4 MMF

Cisco Nexus 9500 Platform Line Cards and Fabric Modules

Cisco 4000 Series Integrated Services Router Packet-over-T3/E3 Service Module

Cisco 1-Port OC-192c/STM-64c POS/RPR Shared Port Adapter

Cisco Nexus 7700 M3-Series 100 Gigabit Ethernet Module

Cisco Nexus 7700 F3-Series 24-Port 40 Gigabit Ethernet Module

Cisco Nexus 7000 Series

Cisco MGE SFP Modules Cisco Small Business Network Accessories

Cisco Nexus 7700 M3-Series 24-Port 40 Gigabit Ethernet Module

Cisco Content Delivery Engine 280 for TV Streaming

ReachNXT 100-8t. Ease of Management Supporting Rapid Network Deployment. Network Security. Theft Deterrents

Cisco Smart PHY 300 and 600 Shelves

Cisco 2-Port, 4-Port, and 8-Port OC-12c/STM-4 Packet over SONET Shared Port Adapters

VIRTUAL EDGE PLATFORM 4600 Next Generation Access

Cisco CRS Forwarding Processor Cards

Cisco 2-Port and 4-Port OC-3c/STM-1c POS Shared Port Adapters

Cisco Nexus 9500 Series Switches

Cisco NCS Gbps Coherent DWDM Trunk Card with CPAK Client Interface

System Specifications

Cisco Video Surveillance 6000P IP Camera

Cisco ASR 1000 Series Ethernet Line Cards

ReachNXT 100-8t. Ease of Management Supporting Rapid Network Deployment. Network Security. Target Applications. Theft Deterrents

Cisco Digital CFP2 Pluggable Optical Module

Cisco ASR 9001 Router

Cisco Nexus 9300 Series Leaf Switches for Cisco ACI. Application Centric Infrastructure

System Specifications

Cisco 1-, 2-, and 4-Port OC-48c/STM-16c POS/RPR Shared Port Adapter

Cisco ASR 9000 Series Modular Line Cards

Cisco ASR 9900 Second Generation Switch Fabric Card 2, Switch Fabric Cards S and T

Cisco Aironet 1540 Series Outdoor Access Points

GigaVUE-2404 // Data Sheet

Cisco Video Management and Storage System Network Module

Cisco Catalyst 9400 Series Switch

Cisco Content Delivery Engine 285 for Open Media Distribution

Sensus. Sensus High-Density Panels for Aggregation and Breakout

Cisco ASR 1000 Series Ethernet Line Cards

Cisco Integrated Services Routers 1941 Series Datasheet

Acme Packet Net-Net 14000

CVU Cisco NCS 1K/2K/4K update. Brian Kvisgaard System Engineer, CCIE SP # May 2016

Cisco Video Surveillance 8400 IP Camera

Cisco Multimedia Line Equalizer/Reverse Conditioner

Cisco Video Surveillance 6400E IP Camera

AllPath OPX. Product Description. AP-4240 Features. Datasheet DS-00102

Retired. HP CWDM Slot B 4-port Add/Drop Multiplexer. HP CWDM 8-port Multiplexer HP CWDM Multiplexer 2-Slot Chassis

Cisco Series Gigabit Ethernet Half-Height Line Card

Cisco Catalyst 9400 Series Switch

Cisco 100BASE-X Small Form-Factor Pluggable Modules for Fast Ethernet Applications

2804 Hybrid Packet Broker

Cisco Nexus 9300 Platform Leaf Switches for Cisco Application Centric Infrastructure

Cisco ATA 191 Analog Telephone Adapter

CISCO 7304 SERIES ROUTER PORT ADAPTER CARRIER CARD

CISCO WDM SERIES OF CWDM PASSIVE DEVICES

Sensus High-Density Panels for Aggregation and Breakout

Cisco CRS-X Modular Services Card

Cyan Z22 Platform. Edge-Optimized P-OTP. Introduction. Benefits

Cisco IP Phone 8851/61 Key Expansion Module

TCX1000 Programmable ROADM

Cisco 2- and 4-Port ISDN BRI S/T Network Interface Modules

Cisco Video Surveillance 8020 IP Camera

Specifications and Part Numbers

Cisco IP Phone 8800 Key Expansion Module

Cisco ONS M2 Multiservice Transport Platform

Cisco Video Surveillance 8030 IP Camera

Cisco 2900 Series Router Datasheet

Cisco ONS SDH 12-Port STM-1 Electrical Interface Card

3299 Rack Mount. Product Highlights. Multifunctional BypassP 2 Segment. Switching Fabric

Cisco ASR 9000v. Product Overview

Cisco Video Surveillance 8630 IP Camera

Separate Video from Audio and Peripheral Data

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions. 40 Channels C21-C60 Dual Fiber DWDM Mux Demux + Monitor Port. 1U Rack Mount, LC/UPC

Cisco Aironet 1560 Series Outdoor Access Points

Transcription:

Data Sheet Cisco Network Convergence System 2000 Series Passive Auxiliary Modules Product Overview The Cisco Network Convergence System 2000 Series (NCS 2000 Series) features a suite of passive modules to accommodate network elements built on the Cisco nlight reconfigurable optical add-drop multiplexer (ROADM) node architecture (Figure 1). Figure 1. Cisco nlight ROADM Architecture Features and Benefits The Cisco nlight ROADM node architecture has been specifically defined and engineered to provide: High reliability: The modular architecture allows complete independence between specific direction-facing units with the ability to house units in physically separated shelves. Low insertion loss: Selected technology allows direct integration of different functions in the same optical module, reducing the number of optical connections. Reduced footprint: The auxiliary passive units integrate power monitoring with an exceptionally small footprint, reducing node power consumption and increasing system density. 2015 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 1 of 14

Each module uses USB to connect with the external connection unit (ECU) of the NCS 2000 Series chassis. The USB communication channel is used to: Retrieve data stored in the nonvolatile memory of the module, specifically, inventory data and the insertion loss of the optical paths Retrieve the optical power levels monitored by the photodiode of the module Activate an LED indicator on the front panel of each module Module Types Three types of modules are available-patch - panel modules, add-drop modules, and adapter modules - all of which fit into the slots of a 1-rack-unit (1RU) mechanical frame chassis (MF 1RU) (Figure 2). Their passive nature helps ensure extremely high availability in a small, low-power footprint. Figure 2. Mechanical Frame Chassis Modular Patch Panel Modules ROADM node architectures built with Cisco nlight ROADM feature a modular approach to degree interconnection, offering an incremental payment model combining just two units: a 5-Degree Patch Panel Module (product number: NCS2K-MF-DEG-5=) and a 4-Degree Upgrade Patch Panel Module (product number: NCS2K-MF-UPG-4=) (Figure 3). Figure 3. Cisco 5-Degree Patch Panel and 4-Degree Upgrade Patch Panel Modules The 5-Degree Patch Panel Module provides interconnections between five 8-port multifiber push-on (MPO) connectors. It is used to connect any combination of up to five ROADM line degrees (express connections) and add-drop components (add-drop connections). The 40 optical paths are interconnected as shown in Figure 4. Five photodiodes provide power monitoring of fiber 1 of each MPO connector. Power values, as well as the manufacturing data stored in the flash memory, are provided to a Cisco Transport Controller through the USB connection. This module is single-slot height in the mechanical frame chassis. 2015 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 2 of 14

Figure 4. Cisco 5-Degree Patch Panel Module Optical Diagram The Cisco 4-Degree Upgrade Modular Patch Panel Module provides interconnections among eight 8-fiber MPO connectors. It is used to expand the number of degrees and the number of add-drop ports supported by the node. The 64 optical paths are interconnected as shown in Figure 5. A total of eight photodiodes provide power monitoring of fiber 1 of each MPO connector. Power values, as well as the manufacturing data stored in the flash memory, are provided to Cisco Transport Controller through the USB connection. This module is single-slot height in the mechanical frame chassis. Figure 5. Cisco 4-Degree Upgrade Modular Patch Panel Module 2015 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 3 of 14

Add-Drop Modules A set of add-drop modules provides colorless, omnidirectional, and flex spectrum add-drop functions to Cisco nlight ROADM nodes. Four different add-drop modules are available (Figure 6): 1 x 16 colorless flex spectrum (CFS) add-drop module 1 x 16 colorless flex spectrum add-drop plus express module 1 x 10 colorless flex spectrum add-drop module 4 x 4 colorless 0mnidirectional flex spectrum (COFS) add-drop module Figure 6. Cisco Passive Auxiliary Add-Drop Units (from top to bottom, 1 x 16 CFS Add/Drop Module, 1 x 16 CFS Add/Drop plus Express Module, 1 x 10 CFS Add/Drop Module, 4 x 4 COFS Add/Drop Module) The 1 x 16 colorless flex spectrum (CFS) add-drop module (product number: NCS2K-MF-16AD-CFS=) is a passive unit comprising one 1 x 16 splitter and one 16 x 1 combiner, plus 17 photodiodes arranged as shown in Figure 7. This module is double-slot height (full height) in the mechanical frame chassis. Its primary function is to provide optical multiplexing and demultiplexing for up to 16 optical signals. Because it is based on optical splitter and combiner technology, only transceivers employing coherent detection can be directly connected to the 16 client ports of the unit. Integrated photodiodes provide connectivity check and monitoring functions. Virtual photodiodes are implemented on the drop ports by subtracting the insertion losses from the photodiode reading on the COM-RX port. Power values, as well as the manufacturing data stored in the flash memory, are provided to Cisco Transport Controller through the USB connection. A second variant of the 1 x 16 colorless flex spectrum (CFS) add-drop (product number: NCS2K-MF-16AE-CFS) includes an express path, which allows wavelengths that do not add and drop to optically bypass the device, which allows the construction of passive add-drop network architectures. 2015 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 4 of 14

Figure 7. 1 x 16 Colorless Flex Spectrum (CFS) Add-Drop Functional Diagram The 1 x 10 colorless flex spectrum (CFS) add-drop module (product number: NCS2K-MF-10AD-CFS) is a passive unit with one 1 x 10 splitter and one 10 x 1 combiner, plus 11 photodiodes arranged as shown in Figure 8. This module is double-slot height (full height) in the mechanical frame chassis. Its primary function is to provide optical multiplexing and demultiplexing for up to 10 optical signals. Because it is based on optical splitter and combiner technology, only transceivers employing coherent detection can be directly connected to the 10 client ports of the unit. Integrated photodiodes provide connectivity check and monitoring functions. Virtual photodiodes are implemented on the drop ports by subtracting the insertion losses from the photodiode reading on the COM-RX port. Power values, as well as the manufacturing data stored in the flash memory, are provided to Cisco Transport Controller through the USB connection. Figure 8. 1 x 10 Colorless Flex Spectrum (CFS) Add-Drop Module Functional Diagram 2015 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 5 of 14

The 4x4 colorless omnidirectional flex spectrum (COFS) add-drop module (product number: NCS2K-MF-4X4- COFS-AD) is a passive unit consisting of eight 2 x 2 optical couplers and eight photodiodes, arranged as shown in Figure 9. This module is single-slot height in the mechanical frame chassis. Power monitoring is present at each channel input port and at each common input port. Virtual photodiodes are implemented on the channel drop ports by subtracting the insertion losses from the photodiode reading on the COM-RX ports. Power values, as well as the manufacturing data stored in the flash memory, are provided to Cisco Transport Controller through the USB connection. The module s primary function is to provide optical multiplexing and demultiplexing for up to four optical signals. Because it is based on optical splitter and combiner technology, only transceivers employing coherent detection can be directly connected to four client ports of this unit. Figure 9. 4 x 4 Colorless Omnidirectional Flex Spectrum (COFS) Add-Drop Module Adapter Modules A set of adapter modules converts between MPO-8, MPO-16, and LC fiber connectors. The following adapter modules are available: MPO-8 to 16 x LC fan-out module MPO-16 to 16 x LC fan-out module MPO-16 to 2 x MPO-8 adapter (two adapters in one module) 2015 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 6 of 14

Figure 10. Cisco Adapter Modules, from top to bottom, MPO-8 to 8 x LC Fan-Out Module, MPO-16 to 16 x LC Fan-Out Module, MPO-16 to 2 x MPO-8 Adapter The MPO-8 to 8 x LC fan-out module provides mechanical adaptation from units offering LC connectors to those with MPO-8 connectors. A total of eight photodiodes provide power monitoring of input and output ports, as shown in Figure 11. Figure 11. MPO-8 to 8 x LC Fan-Out Module Functional Diagram 2015 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 7 of 14

The MPO-16 to 16 x LC Fan-Out Module provides mechanical adaptation from units offering LC connectors to those with MPO-16 connectors. A total of sixteen photodiodes provide power monitoring of input and output ports, as shown in Figure 12. Figure 12. MPO-16 to 16 x LC Fan-Out Module Functional Diagram The MPO-16 to 2 x MPO-8 adapter module provides mechanical adaptation from units offering MPO-8 connectors to those with MPO-16 connectors. Two adaptations are provided per module. Three photodiodes provide power monitoring of input and output ports, as shown in Figure 13. Figure 13. MPO-16 to 2 x MPO-8 Adapter Functional Diagram 2015 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 8 of 14

Combination Mesh Patch Panel Plus Add-Drop Module The 2RU 8-degree mesh patch panel 5-add-drop port module (Figure 14) is a standalone unit providing eight degrees of mesh connectivity and five add-drop ports. In contrast with the modular components described earlier, all express and add-drop connections are contained within the unit, simplifying node fibering. All connectors are either MPO-24 or MPO-8 for easy and direct interconnection to flex spectrum single-module ROADM or contentionless add-drop line cards (Figure 15). Figure 14. 2RU 8-Degree Mesh Patch Panel 5-Add/Drop Port Module Figure 15. 2RU 8-Degree Mesh Patch Panel - 5-Add-Drop Port Functional Diagram 2015 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 9 of 14

Passive Auxiliary Modules Product Specifications Tables 1 through 11 list the specifications of the modules. Product numbers for ordering each module appear in Table 12. Table 1. Optical Specifications for the 5-Degree Patch Panel Module Insertion loss 0 db 1.5 db Insertion loss ripple (wavelength-dependent loss [WDL]) Polarization Dependent Loss () Polarization mode dispersion () Table 2. Optical Specifications for the 4-Degree Upgrade Patch Panel Modules Insertion loss 0 db 1.5 db Table 3. Optical Specifications for the 1 x 16 CFS Add-Drop Module Insertion loss 12 db 14.5 db I.L. uniformity Chromatic dispersion Group delay ripple 45 db 0.3 db 1 db 0.2 db ± 5 ps/nm 10 ps Table 4. Optical Specifications for the 1 x 16 CFS Add-Drop Plus Express Module Parameter Optical Path Minimum Maximum Insertion loss I.L. uniformity Chromatic dispersion Group delay ripple COM-RX EXP-TX EXP-RX COM-TX ADD-i COM-TX EXP-RX DROP-i 6 db 7.5 db 13.5 db 15 db 0.3 db 1 db 0.2 db ± 5 ps/nm 10 ps 45 db 2015 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 10 of 14

Table 5. Optical Specifications for the 1 x 10 CFS Add-Drop Module Insertion loss 10 db 12 db I.L. uniformity Chromatic dispersion Group delay ripple 0.5 db 1 db 0.2 db ± 5 ps/nm 10 ps Table 6. Optical Specifications for the 4 x 4 Colorless Omnidirectional Flex Spectrum Add-Drop Module Insertion loss 6 db 8 db I.L. uniformity Chromatic dispersion Group delay ripple 0.5 db 1 db ± 5 ps/nm 10 ps Table 7. Optical Specifications for the MPO-8xLC Adapter Module Insertion loss 0 db 1.1 db 0.1 ps Table 8. Optical Specifications for the MPO-16xLC Adapter Module Insertion loss 0 db 1.1 db 0.1 ps 2015 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 11 of 14

Table 9. Optical Specifications for the MPO-16 to 2xMPO-8 Adapter Module Insertion loss 0 db 1.5 db Table 10. Optical Specifications for 8-Degree Mesh Patch Panel 5-Add-Drop Port Module Insertion loss 0 db 1.5 db Table 11. Passive Auxiliary Modules Physical Specifications Parameter Power Size (H x W x D) Weight Management Card LEDs Operating Environment Temperature Value 500 mw maximum Relative humidity 5 to 95% 0.67 x 7.05 x 6.5 in. (17 x 179 x 165 mm) for DEG-5, UPG-4, MPO-8LC, 4x4 COFS-AD, MPO-8LC, MPO-16LC, 2MPO-ADP, and 2LC-ADP 1.39 x 7.05 x 6.50 in. (35.2 x 179 x 165 mm) for 16AD-CFS, 16AE-CFS, and 10AD-CFS 3.45 x 17.21 x 10.89 in. (87.6 x 437.1 x 276.7 mm) for PPMESH8-5AD 1.28 lb (0.58 kg) for DEG-5, UPG-4, MPO-8LC, 4x4 COFS-AD, MPO-8LC, MPO-16LC, 2MPO-ADP, and 2LC-ADP 1.76 lb (0.8 kg) for 16AD-CFS, 16AE-CFS, and 10AD-CFS 10.36 lbs. (4.7 kg) for PPMESH8-5AD Each module has two LEDs at the front panel: one blue LED and one three-color LED (yellow, green, and red). Both LEDs can also blink at 0.5 Hz and 2.5 Hz on request. The LED is used to: Notify that the module is powered but not associated. LED not blinking, color yellow Notify that the module is powered and associated. LED not blinking, color green Help operator identify a specific module, light-up blue LED (blinking) 23 to 131 F (-5 to 55 C) 2015 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 12 of 14

Table 12. ROADM Passive Auxiliary Modules Ordering Information Product Name NCS2K-MF-1RU= NCS2K-MF-DEG-5= NCS2K-MF-UPG-4= NCS2K-MF-16AD-CFS= NCS2K-MF-4X4-COFS= NCS2K-MF-MPO-8LC= NCS2K-MF-MPO-16LC= NCS2K-MF-2MPO-ADP= NCS2K-PPMESH8-5AD= NCS2K-MF-16AE-CFS= NCS2K-MF-10AD-CFS= NCS2K-MF-COVER= NCS2K-MF-2LC-ADP= Description Mechanical Frame - 4 slots - 1 RU Mesh Interconnection MF Unit - Up to 5 Degrees Mesh Interconnection MF Unit - Upgrade - 4 Degrees 16-Ports Add/Drop MF Unit - Colorless and Flex Spectrum 4-Degree and 4-Ports Add/Drop MF Unit - CO and Flex Spectrum MPO to 8x LC Fan-Out MF Unit - With Integrated Monitoring MPO-16 to 16xLC Fan-Out MF Unit - With Integrated Monitoring Double MPO-16 to 2xMPO-8 Adapter MF Unit - Monitoring 2RU 8-Degree Mesh Patch Panel- 5-Add/Drop Port + Monitoring 16-Port Add/Drop + Express MF Unit - Colorless Flex Spectrum 10-Port Add/Drop MF Unit - Colorless Flex Spectrum 1 RU Cover for the Mechanical Frame Double LC-LC Adapter MF Unit Table 13 provides regulatory compliance information for all units included in this data sheet. Table 13. Regulatory Compliance 1 Countries Supported ANSI System Canada United States Korea Japan European Union EMC (Class A) ICES-003 (2004) GR-1089-CORE Issue 6, NEBS EMC and Safety (May 2011) 47 FCC part15 (2011) Safety UL/CSA 60950-1,Second Ed 2011 GR-1089-CORE Issue 6, NEBS EMC and Safety (May 2011) Laser UL/CSA 60950-1,Second Ed 2011 IEC 60950-1(2005/12), 2 nd Edition and National Differences as per CB Bulletin 112A +Amendment 1: 2009 IEC-60825-2 Edition 3.1, 2007/01 ETSI System European Union Africa CSI Australia New Zealand China Korea India Saudi Arabia South America EN 300 386 Telecommunications Network Equipment (EMC): 2008 (Note: EMC-1) CISPR22 Ed.6 (2008) and CISPR24: Ed.2 (2010) EN55024 Ed.2 2010: Immunity levels: see EN61000-4-xx EN55022: 2007 Information Technology Equipment (Emissions)(2006) (EMC-2) UL/CSA 60950-1,Second Ed 2011 IEC 60950-1(2005/12), 2 nd Edition and National Differences as per CB Bulletin 112A + Amendment 1: 2009 CDRH (accession letter and report) IEC 60825-1 Ed. 2 2007-03 2015 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 13 of 14

Countries Supported Environmental GR-63-CORE Issue 4, NEBS Physical Protection (Apr 2012) ETS 300-019-2-1 V2.1.2 (2000-09) (Storage, Class 1.1) ETS 300-019-2-2 V2.2.1 (2011-11): Transportation, Class 2.3 ETS 300-019-2-3 V2.2.2 (2003-04): stationary use, Class 3.1E Warranty The following warranty terms apply to the Cisco NCS 2000 as well as services you may use during the warranty period. Your formal warranty statement appears in the Cisco Information Packet that accompanies your Cisco product. Hardware warranty duration: Five years. Software warranty duration: One year. Hardware replacement, repair, or refund procedure: Cisco or our service center will use commercially reasonable efforts to ship a replacement part for delivery within 15 working days after receipt of the defective product at the Cisco site. Actual delivery times of replacement products may vary depending on customer location. Product warranty terms and other information applicable to Cisco products are available at: http://www.cisco.com/go/warranty. Cisco Services for Migrating Converged IP+Optical Solutions Services from Cisco and our partners help you get the most value from your investments in your Cisco converged IP+Optical solution, quickly and cost effectively. We can help you design, implement, and validate your solution to speed migration and cutover. Coordinate every step through to interworking. Strengthen your team. And make the most of tomorrow s opportunities. Learn more at http://www.cisco.com/go/spservices. Cisco Capital Financing to Help You Achieve Your Objectives Cisco Capital can help you acquire the technology you need to achieve your objectives and stay competitive. We can help you reduce CapEx. Accelerate your growth. Optimize your investment dollars and ROI. Cisco Capital financing gives you flexibility in acquiring hardware, software, services, and complementary third-party equipment. And there s just one predictable payment. Cisco Capital is available in more than 100 countries.learn more. Printed in USA C78-735034-00 07/15 2015 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 14 of 14