Technical Information WirelessHART Fieldgate SWG70

Similar documents
WirelessHART Adapter SWA70

Technical Information WirelessHART Adapter SWA70. Smart WirelessHART interface module with power supply for field devices. Products Solutions Services

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Technical Information WirelessHART Adapter SWA70. Smart WirelessHART interface module with power supply for field devices. Products Solutions Services

Technical Information Fieldgate SFG500

Supplementary Components WirelessHART products

Technical Information RIA16

WirelessHART Fieldgate SWG70

General Specifications

Intelligent WirelessHART gateway with Ethernet and RS-485 interface

Technical Information RIA16

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

CPU module for zone 2 Series 9442/35

RAD-WHG/WLAN-XD. WirelessHART gateway with integrated WLAN (802.11b/g) INTERFACE Data Sheet 2720_en_C. 2 Features. 1 Description

General Specifications

4 â Active barrier RN221N with optional HART diagnosis. Technical Information

Supplementary Components WirelessHART products

ZBRN1 access point- 2 RJ V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio

SITRANS T measuring instruments for temperature

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

ZBRN1 access point- 2 RJ V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio

Technical Information Field Xpert SMT70

Technical Information TLSR1 RTD measuring sensor

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

Technical Information Promonitor NRF560

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

ZBRN1. Main. Device short name

Technical Information RIA15

PSI-MODEM-SHDSL/SERIAL Copper Extender

Safety Instructions Cerabar S PMP71, PMP75

ICF-1150 Series Quick Installation Guide

THE PEPPERL+FUCHS GROUP. WirelessHART Products Overview Karsten Fischer - Global Account Manager Invensys

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. WirelessHART components Gateway and accessories

Operating Instructions 12/2010 MN Z-EN XV-152 MICRO PANEL

Ethernet CPU Module & Power Module for Zone 1 / Div. 1 Series 9441/12 and 9444/12

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Model R-1420 Wireless Gateway

Wireless Corrosion Monitoring System

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

General Specifications

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

D5090S INSTRUCTION MANUAL. D A SIL 3 Relay Output Module for NE Load. DIN-Rail and Termination Board, Model D5090S

Pro. LCN1840/05 Wireless gateway. Specification sheet. Connected lighting. Find out more about Interact

DTM Distributed Transmitter Monitor

Technical Information Field Xpert SFX350, SFX370

Fieldgate FXA320, FXA520 Gateway for remote monitoring of ma and HART measuring devices

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

DeltaV Wireless I/O Card

Fieldgate FXA320, FXA520

Programming unit VIATOR HART modems Model PU-H

DeltaV Bulk Power Supplies

Smart Wireless THUM Adapter

PSI-MODEM-SHDSL/SERIAL

Technical Information Field Xpert SMT70

ICF-1150 Series Quick Installation Guide

Series 3730 Type Electropneumatic Positioner

MINI MCR-SL-UI-2I-NC. Extract from the online catalog. Order No.:

MINI MCR-SL-PT100-UI-200

IntesisBox Modbus Server Panasonic

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

Series 3730 Electropneumatic Positioner Type

itemp TMT180 Technical information

Priva Blue ID Digital input module DI4/DI8/DI16

PanelView Plus/VersaView CE Terminals and Display Modules

2 Device description. 2 Device description 2.1 Function. 2.1 Function. 2.2 Intended use. 2.3 Device versions

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Minilog RDL10. Technical Information. Measured value collector with 2 input channels for storing analog and digital values

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

SITRANS P measuring instruments for pressure

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

DeltaV Bulk Power Supplies

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Termination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div.

iologik E1200H Series

MINI-PS AC/10-15DC/8

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

Power Supply HARTING pcon

WIRELESS GATEWAY DUOS

Safety Standards. Model Number: Unit Weight:

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

4 â RIA251. Technical Information. Process display Digital loop powered display for ma current loops

MINI MCR-SL-CVS NC

Inductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

D1093S INSTRUCTION MANUAL. D SIL 3 Relay Output Module with Line and Load diagnostics. DIN-Rail Model D1093S

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

UFD 5. Display for ALTOSONIC 5. Technical Datasheet. Configurable display for ALTOSONIC 5 Easy installation Durable design

Transcription:

TI00027S/04/EN/14.14 71247524 Products Solutions Services Technical Information WirelessHART Fieldgate SWG70 Intelligent WirelessHART gateway with Ethernet and RS-485 interfaces Application Fieldgate SWG70 serves as a gateway device for WirelessHART networks. It enables WirelessHART devices to communicate with each other and manages security and connectivity. Fieldgate converts and stores wireless device data in a format that is compatible with other systems. It has Ethernet and serial interfaces for connection to host applications such as SCADA tools. Features and Benefits Gateway, Network Manager, and Network Access Point capabilities according to the WirelessHART specification: works with all WirelessHART adapters and devices RS-485 and Ethernet interfaces with support of HART and Modbus: network data easily integrated into existing system Flexible configuration and parametrization via FDT/DTM or Web-Interface: clear presentation of network, measured values and diagnosis information Local or Remote antenna options: easily adapted to local installation conditions

Function and System Design WirelessHART WirelessHART Fieldgate SWG70 System design WirelessHART is a HART Communication Foundation specification for use in process automation. It adds wireless capabilities to the HART protocol while maintaining compatibility with existing HART devices, commands, and tools. A WirelessHART network comprises: Wireless field devices Non-wireless field devices enhanced by using a WirelessHART adapter Gateways that enable communication between devices and host applications A Network & Security Manager responsible for configuring, managing and monitoring the network. Endress+Hauser s SWG70 WirelessHART Fieldgate has been designed to act as interface between a system using Ethernet or RS-485 physical layer and the WirelessHART network. It supports the following functions: Wireless network configuration and management Acquisition of data from the network devices and presentation to the connected system Web server supporting HART and MODBUS protocols for data transfer Network, Fieldgate and device configuration via Web interface or FDT/DTM. The gateway is designed for mounting in explosion hazardous areas Zone 2 and has an intrinsically safe antenna port. An integral or remote antenna can be mounted according to the needs of the application. The WirelessHART Fieldgate stores information received from the WirelessHART Adapter SWA70 or other WirelessHART device in a buffer which can be accessed by a host application over an Ethernet or RS-485 connection. The figure below shows it operating in a typical meshed WirelessHART network architecture. 2

Input Wireless interface WirelessHART communication interface (IEC 62591) Physical layer IEEE 802.15.4; 2006 Transmission rate Operating frequency Transmission range RF power level Nominal 250 kbits/s 2.4 GHz (ISM band) Under reference conditions: Outdoor 250 m, indoor 50 m Configurable 0 dbm or 10 dbm, depending upon national regulations Input variables Process variables according to HART standard sent in burst mode by devices in network Up to 250 WirelessHART devices can be connected Additional functions Security mode for join key and network ID download (enabled by DIP switch) Buffering of process values for acquisition by host application Output Ethernet (100 BASE-T / 100 BASE TX) Protocol Transmission rate Type of protection Galvanic isolation Maximum bus length Connection facilities Configurable for HART-IP and MODBUS-TCP communication 100 Mbit/s (max. cable length 100 m at 25 C ambient temperature) None Fully isolated from all other circuits 100 m (110 yds) depending upon cable 7-port terminal block Screw terminals: 0.2 mm 2 to 4 mm 2 for solid wire, 0.2 mm 2 to 2.5 mm 2 for stranded wire RS-485 serial interface Protocol Transmission rate Type of protection Galvanic isolation Maximum bus length Terminal resistor Connection facilities Configurable for HART Version 7.0 or MODBUS-RTU communication Hardware or software configurable between 1200 bit/s to 115200 bit/s None Fully isolated from all other circuits 1200 m (1230 yds), depending upon cable and transmission rate Integrated, settable by hardware (DIP-switch) or software Two 3-port terminal blocks, allowing series connection of several gateways Screw terminals: 0.2 mm 2 to 4 mm 2 for solid wire, 0.2 mm 2 to 2.5 mm 2 for stranded wire 3

Power Supply Power supply 20 VDC to 30 VDC Power <5 W Connection facilities Two 2-port connection block, 2nd port for redundant power supply Screw terminals: 0.2 mm 2 to 4 mm 2 for solid wire, 0.2 mm 2 to 2.5 mm 2 for stranded wire Operating Conditions Installation Installation instructions Location: If possible, avoid mounting too near pipes, heavy-duty electrical equipment etc. Fieldgate should be in radio contact with at least 20 % of all wireless devices or adapters. Maximum separation 250 m outdoors, 50 m indoors under typical conditions Mounting: Remote antenna can be mounted outside of a cabinet. Orientation: With antenna vertical. Ex-Area: Fieldgates with certificate, see Ordering Information, may be mounted in Zone 2. The front panel can be opened in Zone 2 to view the LEDs. Operation of the DIP switches and pushbuttons is not allowed in the presence of an explosive atmosphere. Environment Ambient temperature range 20 C to +60 C / 4 F to 140 F Storage temperature 40 C to +85 C / 40 F to +185 F Relative humidity 5 % to 95 %, non-condensing Vibration resistance EN 60068-2-6: 10 Hz f 150 Hz/1g Shock resistance EN 60068-2-27: 15 g, 11 ms Electromagnetic compatibility Complies with the requirements of the EC Directive 2004/108/EG "Electromagnetic Compatibility" IEC 61326: Immunity: EN 61326-1: 2006, industrial environment Emission: EN 61326-1: 2006, Class A equipment Telecommunication compliance Complies with the requirements of the EC Telecommunications Directive 99/5/EG ETSI EN 300 328: V1.7.1 (2006-10) ETSI EN 301 489-17: V1.2.1 (2002-08) EN 60950:2001 4

Mechanical Construction Overall dimensions W x H x D: 257 mm x 85 mm x 285 mm with cable glands and antenna 257 mm x 85 mm x 115 mm without cable glands and antenna mm (inch) 257 (10.12) 228 (8.98) 115 (4.53) 57 (2.24) 150 (5.91) 150 (5.91) 52 (2.05) 85 (3.35) Centers 240-250 (9.45-9.84) 115 (4.53) 10 (0.39) 20 (0.79) 52 (2.05) 85 (3.35) 228 (8.98) 257 (10.12) 20 (0.79) Weight Housing Approx. 1.6 kg Material: Painted aluminum Color: Light grey, RAL 7035 Degree of protection IP 65; NEMA Type 4 Type of protection Cable Entry Antenna Complies with the requirements of the EC Directive 94/9/EG (ATEX) "na", non-sparking to EN 60079-15:2005 5 separate M20x1.5 threaded entries Omnidirectional dipole antenna Intrinsically safe antenna port Remote antenna available on request 5

Operability Configuration Web browser via Ethernet FieldCare via Ethernet (HART-IP CommDTM) or RS-485 (serial CommDTM) Operating elements Operating elements are located within the housing The front cover can be removed in Zone 2. The connection of cables in Zone 2 is permitted only in the absence of any explosive atmosphere or with the power turned off. 1 2 3 4 m Five LEDs, from left to right: Yellow LED: RS-485 communication status Green LED: Power supply Yellow LED: WirelessHART communication status Red LED: Fault Yellow LED: Ethernet communication status n, o Two pushbuttons "P1" and "P2" Button P1: Reset to default fieldgate configuration Button P2: Reset to default communication channel configuration Button P1 and P2: Reset passwords, and if security mode enabled, reset join key and network ID p Bank of eight DIP switches Switches 1 4: Polling address, 0 to 15 (by software from 0 to 63) Switches 5 6: Serial baudrate, 9600 bit/s, 19200 bit/s, 38400 bit/s, 57600 bit/s (by software from 1200 bit/s to 115200 bit/s) Switch 7: RS-485 termination, disconnected, connected (also configurable by software) Switch 8: Security mode, disabled, enabled Configurable functions Wireless network HART, Modbus and Ethernet communication interfaces Diagnosis Display of wireless instrument list with process values of selected device Display of wireless instrument list with burst message identification of selected device Network monitoring of wireless communication events Diagnosis function 6

Ordering Information Product structure Detailed information on the product structure is available: In the Product Configurator on the Internet page: www.endress.com È Select country È Products È System components & recorders È Wireless Communication È WirlessHART Fieldgate SWG70 È Product page function: Configure this product At your Endress+Hauser Sales Center: www.addresses.endress.com Accessories Remote antenna Further accessories on request Documentation WirelessHART Fieldgate SWG70 WirelessHART Fieldgate SWG70 Operating Instructions BA00064S/04/en WirelessHART Adapter SWA70 Operating Instructions BA00061S/04/en WirelessHART Adapter and Fieldgate Competence Brochure CP013S/04/en Certificates and Approvals CE Mark In attaching the CE Mark, Endress+Hauser confirms that WirelessHART Fieldgate SWG70 conforms to all relevant EU directives. Telecommunication Approval Brazil: ANATEL 2759-11-7311 (EAN Number: 7898994191414) China: CMIIT ID (SRRC) ETSI (R&TTE) FCC Part 15.247 for wireless applications in the 2.4 GHz frequency band Japan: Ministry of internal affairs and communication Mexico: COFETEL RCEPNSW12-0651 Other national certificates are available on request. Additional national guidelines to be observed Country Bulgaria Italy Norway Rumania Latvia Guideline General authorization required for outdoor use and public service If used outside of own premises, general authorization is required May be restricted in the geographical area within a radius of 20 km from the center of Ny-Alesund Use on a secondary basis. Individual license required The outdoor usage of the 2,4 GHz band requires an authorization from the Electronic Communications Office Hazardous area approvals See ordering information. 7

www.addresses.endress.com WirelessHART Fieldgate SWG70