Features. Reliable High RF Shielding. Pneumatic control of lid open-close and optional test fixture motions

Similar documents
TC-5972DP Pneumatic Shield Box

TC-5972D Shield Box. Features. High RF Shielding. Easy Opening/Closing of lid. EMI filter on all Data and DC lines. Customizable Data connections

TC-5921A Shield Box. Features. High RF Shielding. Easy Opening/Closing of lid. EMI filters on all Data and DC lines

TC-5915A Shield Box. Features. High RF Shielding. Easy Opening/Closing of lid. EMI filters on all Data and DC lines

Features. High RF Shielding. Easy Opening/Closing of lid. EMI filters on all Data and DC lines. Easily customizable to meet various test needs

Features. High RF Shielding. Easy Opening/Closing of lid. EMI filters on all Data and DC lines. Easily customizable to meet various test needs

CBL Starter Cable Kit for DuraNAV System

Wireless RF Test Enclosures

OMNI Expandable HMI Panel Computer with Intel Celeron J1900/ N2807 Processor

iologik 4000 Series Modular remote I/O Introduction iologik E4200 Specifications Remote I/O Slice Form Factor and Flexible I/O Variety

Model 7705 Control Module

Compact Redundancy Switch 2:1 RSCC-2

RF switch network. RFB 2000, RFC 2010 or 2020

Cabinet Interface Device

Power Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground

Portable Ground Control Station Sentinels portable Ground Control Station (GCS) is designed for controlling unmanned vehicles

Time Counters mini "h", DC Version

Prisma II Platform. Optoelectronics

Hardened 10/100Base-TX IEEE802.3at PoE PSE Ethernet Extender

Compact Redundancy Switch 2:1 RSCC-2

Safety Mats & Area Guarding

Media Converters. Media Converters. Product Selection Guides

RF SWITCH NETWORK RFB 6000

Power Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground

Connecting a Cisco Input Module

NetCom Plus 111 (NetCom 111)

ASSEMBLY, INSTALLATION, AND REMOVAL OF CONTACTS AND MODULES

AgilentTechnologies TS-50 RF Shielded Test Fixtures

Cisco Prisma II Platform

Ultrasonic Bolting Equipment, Transducers & Accessories - Price List Date: 02/01/18

DVBCommunity - cообщество профессионалов ЦТВ 4IN1 DVB-S2 IP/SPTS IRD with 4CI >>User Manual

2100 POS System User Guide

16 way 19 1½U enclosure with rear cable management tray NPGZM-16-NJ. ½U high front mounting cable management tray

Domain 3000 Back Panel

Application. Characteristics RTU540. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

Control Panel CP600 CP651, CP651-WEB

TOUCH SCREEN CONTROLLER for Air Conditioning Control System

NetCom Plus 411 (NetCom 411, NetCom 411 PRO)

Submittal Data Sheet WAGO Node for itm

13 x13 Modular. LED Dance Floor. General Description: Specification:

DPA 7000 PATENTS PENDING TELEPHONE AND LINE ANALYZER

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

Installation Guide. 100BASE-TX/100BASE-FX Fast Ethernet Media Converter NC-200FT/FC. -1-iIiNC-200FT/FC P/N:

Features. SC Switch Control Platforn. SC2000, SCX2000, SCP2000 SCM Series Modules

IS-3000-LS-ABB INFRARED SCANNER

TELEPHONE AND LINE ANALYZER

ADVANCED TECHNICAL MANUAL AAC1 SMALL SYSTEM CONTROL CONSOLE. Redefine your comfort zone.

NetCom Plus 113 (NetCom 113, NetCom 113 PRO)

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink

Control Panel CP600-eCo CP604, CP604-B

5 Performance Verification

Quick Start Guide. Installation. User s Manual 1

Control Panel CP600 CP635, CP635-B, CP635-WEB

EDX-10 Series. Compact Recording System

PRODUCT CATALOG INTELLISENSE PREDICTIVE INTELLIGENCE FOR PNEUMATICS

Bluetooth to Serial Converter TOP FRONT. Click 421

Portable Ground Control Station

NetCom Plus 413 (NetCom 413, NetCom 413 PRO)

Energy 3000 Primary Switched Power Supply 3000W VE3PUID ,5/L programmable V/I

With the use of Mini-Circuits low cost Hand-Flex interconnect cables, multiple matrix configurations can be easily created by the user.

Redundancy Switch Controller 1:1 RSCM1

Overview of the Cisco Wireless Gateway for LoRaWAN

Highest-performance Industrial PC

900 MHz Spread Spectrum Radio TOP FRONT. Click 400

Internet Office UPS System - All-in-one SOHO Solution

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR065-48S / OPR065-48R. Manual

ITEM NO: SP-001, SP-001P, SP-001VP, SP-001VPD, SP-002, SP-002VP, SP-002VPD, SP-003, SP-004, SP-004VPD, SP-005, SP-006, SP-016C, SP-016T

Characteristics. Application RTU560. HMI unit 560HMR01. Data Sheet HMI unit 560HMR01

VCL-TP, Teleprotection Equipment With Trip Counter Display Panel

ELECTROMECHANICAL SWITCH MATRICES

1 to 16-port RS-232, RS-422/485, and RS-232/422/485 USB-to-serial converters. Features and Benefits. Certifications

MW5501C Series MW5502C Series. 1 or 2-Port Industrial Wireless Modbus TCP/RTU/ASCII Gateway FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

Corona 70,000 Ft. Permeability Risetime Degradation (Mated Pair) 2.0 max MH z

Hardened Media Converter

MTS Systemtechnik GmbH - Shielding Box Series MSB

Telephony Multi-Taps. 9000T-TP Series

Series PC 3.5 precision subminiature connectors

OMNI Expandable HMI Panel Computer with Intel Celeron J1900/ N2807 Processor

Aironet and WLAN Controller Product Power Options

Industrial 3-Port Fast Ethernet Media Converter Switches

SCC5-RM. Coloronix, Inc West Jefferson Boulevard Los Angeles, California (323)

DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E

iologik E4200 Modular Active Ethernet I/O adaptor IT and Instrumentation for industry Introduction Specifications LAN Regulatory Approvals Warranty

8806 Series. 15 Multi-functional Touch Panel PC. Quick Reference Guide

iologik 4000 Series (M) Modules

Entry Line Industrial Gigabit Ethernet Bridging Converter, PoE+ optional 1x 10/100/1000Base-T, 1x 100/1000 SFP

OBSOLETE. CanWorks itrax Two-Channel Control Unit Installation. Instruction Sheet P/N A

EMSwitch RF Switch Plug-In Card

Installing the Cisco AS5400XM Universal Gateway

Modular Test System. ZTM Series

OmniSmart 230V 350VA 225W CE/IEC Medical Grade Line-Interactive UPS with Built-In Isolation Transformer

Features and Benefits. Certifications

FX-485PC-IF RS485 Interface Unit Hardware Manual

Platform. Product Data Sheet PDS A01 January, 2004 NGA 2000

ANIxx. Installation Manual.

CalibratorUnit Models CPU6000-W, CPU6000-S, CPU6000-M

ORYON RING LIGHTS. 14 in. Ring Light and 18 in. Ring Light. Quick Start Guide. What s Included

Table of Contents. 1 Welcome. 2 Install your Access Point-I. 3 Using the Access Point-I

Device Server for the conversion of serial interfaces (RS-232/422/485) to IP.

Connecting a Cisco Reader Module

Transcription:

TC-5972AP/CP Pneumatic Shield Box Features Reliable High RF Shielding Pneumatic control of lid open-close and optional test fixture motions Easily customizable to meet various test needs Shock Absorbers on lid Red and Green LED s for Pass/Fail indication EMI filters on all data ports and power line Remote operation by RS-232C Ferrite observer for radiation testing (TC-5972CP)

Specifications Mechanical Specification RF Connectors without module 4 N (f) outside and SMA (f) inside Line voltage DC 24 V, Max. 2A. Remote control RS-232C, 3 wire, DB9(s) Air connection Main connector 6 mm OD hose, one-touch push-on fitting Fixture control connector 4 mm OD hose, one-touch push-on fitting Input air pressure 5 to 10 bar Dimension Inside 470(W) x 470(D) x 360(H) mm, 230(D)mm top side Outside 546(W) x 620(D) x 444(H) mm, door closed. 687(H) mm, door open Door 420(W) x 358(H) Weight approx. 48 kg *Packing Size 810 (W) x 630(D) x 575(H) mm Weight approx. 51 kg *The size or weight of a package may vary on how to pack a package. Typical RF Shielding The shield effectiveness below is measured when the blank panel is mounted; other I/O interface panel results a different shielding effectiveness of the shield box. 100 to 2000 MHz > 70 db 2000 to 3000 MHz > 70 db 3000 to 6000 MHz > 50 db

Ordering Information Order Number Description Pneumatic Shield Box (including accessories bellow) TC-5972AP TC-5972CP Operating Manual Test Report RG400S, N(m) to N(m) cable, 1 m, 1 pc DB9(p) to DB9(s) cable, 2 m, 1 pc. Air Coupler Switching Power Supply Pneumatic Shield Box (including accessories bellow) Operating Manual Test Report RG400S, N(m) to N(m) cable, 1 m, 1 pc DB9(p) to DB9(s) cable, 2 m, 1 pc. Air Coupler Switching Power Supply I/O Interface Panel Order Number M5970C01A Configuration *Shielding Effectiveness:, Blank Panel M5970C02A *Shielding Effectiveness: >70 db from 0.1 to 3 GHz >60 db from 3 to 6 GHz AC Inlet, 100 VAC~300 VAC, 10 A RF and AC Power Panel

M5970C03A *Shielding Effectiveness: >60 db from 0.1 to 3GHz, RJ-45 outside and inside, 10 pf Pi filter One DB25(p) outside, DB25(s) inside, 1000 pf Pi filter RF and RJ45, DB25 Data Interface Panel M5970C04A *Shielding Effectiveness: >60 db from 0.1 to 3 GHz, USB outside and inside One DB25(p) outside, DB25(s) inside, 1000 pf Pi filter RF and USB, DB25 Data Interface Panel * Shielding effectiveness indicated above is the measured value obtained with the respective connectors installed. I/O Interface Customized I/O Interface panels are available. Please contact us. I/O Interface Order Number Typical Data Rate *Typical Shielding / Line Voltage 3409-0009-1 3 Mbps DB25, 1000 pf Pi Filter 3409-0014-1 10 Mbps DB25, 100 pf Pi Filter DB9, 1000 pf Pi Filter DB9, 100 pf Pi Filter 3409-0008-1 3 Mbps 3409-0010-1 10 Mbps

3409-0018A-3 480 Mbps >60 db from 0.1 to 6 GHz USB A(p) 2.0, 10 pf Pi Filter 3409-0022A 250 Mbps >60 db from 0.1 to 3 GHz RJ-45, 10 pf Pi Filter DC Power Adaptor, Jack Type 3409-0004A 50 VDC, 3 Amps max 3409-0005A 50 VDC, 50 VDC, 10 Amps max DC Power Adaptor, Banana Jack Type 250 VAC, 7 Amps max AC Power Adaptor *Shielding effectiveness indicated is with specific connector installed on I/O interface panel.