NI crio Contents USER MANUAL. Embedded Real-Time Controller with Reconfigurable FPGA for C Series Modules

Similar documents
Reconfigurable Embedded Chassis with Integrated MXI-Express (x1) MXI-Express Switch

NI CMS-9068 and NI MMS-9068

NI CMS Contents MAINTAINING HARDWARE. NI Condition Monitoring System for NI InsightCM Enterprise

NI CMS Contents MAINTAINING HARDWARE. NI Condition Monitoring System for NI InsightCM Enterprise

NI sbrio Safety Guidelines GETTING STARTED GUIDE. Single-Board RIO OEM Devices. This document describes how to begin using the NI sbrio-9627.

Embedded CompactRIO Controller with Real-Time Processor and Reconfigurable FPGA. Intel Atom E GHz Dual-Core System-On-Chip

NI ELVIS RIO Control Module

GETTING STARTED GUIDE NI Channel, 50 Arms Continuous, 24-Bit, Analog Input Module

Embedded CompactRIO Controller with Real-Time Processor and Reconfigurable FPGA. Intel Atom E GHz Dual-Core System-On-Chip

Embedded Real-Time Controller with Reconfigurable FPGA for C Series Modules. This document describes how to begin using the NI crio-9064.

NI crio-9035 USER MANUAL. Embedded CompactRIO Controller with Real-Time Processor and Reconfigurable FPGA

R Series Digital I/O Module for PCI Express, 128 DIO, 512 MB DRAM, Kintex-7 160T FPGA. This document describes how to begin using the PCIe-7821R.

Embedded CompactRIO Controller with Real-Time Processor and Reconfigurable FPGA. Intel Atom E GHz Quad-Core System-On-Chip

Embedded CompactRIO Controller with Real-Time Processor and Reconfigurable FPGA

Embedded Direct Injector Control and Measurement (DCM) Device with Real-Time Processor and Reconfigurable FPGA

R Series Reconfigurable I/O Module (AI, AO, DIO) for PXI Express, 6 AI, 18 AO, 48 DIO, 1 MS/s AIO, 512 MB DRAM, Kintex-7 160T FPGA

NI Safety Guidelines. Safety Guidelines for Hazardous Locations GETTING STARTED GUIDE. Ethernet Expansion Chassis for C Series Modules

Embedded CompactRIO Controller with Real-Time Processor and Reconfigurable FPGA

IVN Safety Guidelines GETTING STARTED GUIDE. 100BASE-T1 Media Converter

NI CVS Required Components. Optional Equipment GETTING STARTED GUIDE. Compact Vision System with USB3 Vision and Reconfigurable I/O

Bracket and Mounting Dimensions

Electromagnetic Compatibility Guidelines

GETTING STARTED GUIDE NI V, 32-Channel (Sinking Input), 7 µs C Series Digital Module

NI R Series. Contents. Software CALIBRATION PROCEDURE

Reconfigurable Embedded Chassis with Integrated Intelligent Real- Time Controller for CompactRIO. Intel Core i7-660ue 1.33 GHz Dual-Core Processor

SAFETY, ENVIRONMENTAL, AND REGULATORY INFORMATION. NI CompactDAQ Four-Slot Controller with Quad-Core Processor

GETTING STARTED GUIDE NI AO, 0 ma to 20 ma, 16 Bit Simultaneous

CompactRIO crio-9068 Reconfigurable Embedded Chassis with Integrated Intelligent Real-Time Controller for CompactRIO

GETTING STARTED GUIDE NI Channel Solid-State Relay (SSR) Digital Output Module

NI PCIe-784xR, NI PXI-784xR, NI PXIe-784xR, NI USB-784xR, NI PCIe-785xR, NI PXI-785xR, NI PXIe-785xR, NI USB-785xR, and NI PXIe-786xR

NI USRP-2900/2901. Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. Universal Software Radio Peripheral

CALIBRATION PROCEDURE PXIe channel, 16-bit, 400 ks/s/ch, Ch-Ch Isolated Analog Input Module. ni.com/manuals

Contents. Software. CALIBRATION PROCEDURE NI Channel, 300 Vrms, 24-Bit, Simultaneous, Channel-to-Channel Isolated Analog Input Module

24-Channel, ±24 V Precision PXI Source Measure Unit

GETTING STARTED NI 9501 C Series Stepper Drive Modules and NI SoftMotion Module

NI crio-9101/9102/9103/9104

Contents. Software. CALIBRATION PROCEDURE NI Channel, ±5 V, 24-Bit Software-Selectable IEPE and AC/DC Analog Input Module

12-Channel, ±24 V Precision PXI Source Measure Unit

R Series for PXI Express Digital RIO with Kintex-7 325T FPGA. ni.com/manuals. This document explains how to install and configure the NI PXIe-7822R.

Contents. Software. CALIBRATION PROCEDURE NI 9216/ Channel, 24-Bit, 100 Ω/1000 Ω RTD Analog Input Module

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9476E. 32-Channel, 24 V Sourcing Digital Output Module

±10 V, 20 MS/s/ch, 14-Bit, 4-Channel C Series Digitizer Module

R Series for USB Multifunction RIO with Kintex-7 160T FPGA. ni.com/manuals. Electromagnetic Compatibility Guidelines

R Series for USB Multifunction RIO with Kintex-7 70T FPGA. ni.com/manuals

GETTING STARTED GUIDE NI Channel, 60 V, High-Speed, Sourcing Digital Output Module

NI PXIe-4138/4139. Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. Single-Channel System SMU

SPECIFICATIONS AND FEATURES GUIDE NI Serial Legacy Hardware

R Series for USB Multifunction RIO with Kintex-7 160T FPGA. ni.com/manuals

NI SMD-7610 Stepper Drives and NI 9512 C Series Modules

CALIBRATION PROCEDURE NI channel, ±2- ma/±10 V, 24-bit Analog Input Module. ni.com/manuals

NI REM Remote I/O Overview DATASHEET. Bus Coupler for Remote I/O

R Series for USB Multifunction RIO with Kintex-7 70T FPGA. ni.com/manuals. Electromagnetic Compatibility Guidelines

Thermal Kit for NI sbrio-9607/9627/9637

GETTING STARTED GUIDE NI AI, 100 S/s/ch Simultaneous, Universal Measurements

Figure 1. NI-7935R. Related Information For information about the device specifications, refer to the NI-7935R Specifications at ni.com/manuals.

Foundation Fieldbus Hardware and NI-FBUS Software

GETTING STARTED NI SMD-7611/7612 Stepper Drives and NI 9512 C Series Modules

NI REM Remote I/O Overview DATASHEET. Digital Input Module for Remote I/O

10 MHz to 6 GHz, x86 Processor, GPS-Disciplined OCXO, USRP Software Defined Radio Stand-Alone Device

NI PXIe-4080/4081/4082

Electrical. SPECIFICATIONS SH Cable

NI USB Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. 10 MHz to 18 GHz RF Power Meter

This document includes instructions for installing and configuring your PXIe-8861 PXI Express controller module.

Related Information Refer to the NI Switches Help for detailed information about features and programming options for your NI switch product.

USRP Contents. Verifying the System Requirements GETTING STARTED GUIDE. USRP Software Defined Radio Stand-Alone Device

NI PXIe Contents GETTING STARTED GUIDE. RF Preselector Module

PXIe Contents GETTING STARTED GUIDE. 32-Channel Digital Pattern Instrument

This document includes instructions for installing and configuring your PXIe-8821 PXI Express controller module.

PXIe Contents. Verifying the System Requirements GETTING STARTED GUIDE. 32-Channel Digital Pattern Instrument

Compact Vision System with USB3 Vision and Reconfigurable I/O

NI WSN-9791 Ethernet Gateway

GETTING STARTED GUIDE

FieldPoint cfp-20xx. Quick Start Guide. What You Need to Get Set Up

To access NI 5622 documentation, navigate to Start»All Programs»National Instruments» NI-SCOPE»Documentation.

NI REM Remote I/O Overview DATASHEET. Digital Output Module for Remote I/O

Contents. CALIBRATION PROCEDURE NI PXIe-5624R 2 GS/s, 12-Bit IF Digitizer

SH Cable Specifications

This document contains detailed electrical and mechanical information for the National Instruments IC-3121.

NI PXI Contents GETTING STARTED GUIDE. 8 GHz RF Amplifier

CALIBRATION PROCEDURE CAL Contents. Software

CALIBRATION PROCEDURE NI PXIe Channel, Isolated Voltage/Current Analog Output Module

The NI TB-2648/2649/2650/2651 terminal blocks configure your NI PXI/PXIe-2531 (NI 2531) in one of the following topologies. 1-wire 8 64 matrix

GETTING STARTED GUIDE NI S/s/channel, 4-Channel C Series Universal Analog Input Module

NI PXI Contents GETTING STARTED GUIDE

INSTALLATION INSTRUCTIONS SH160F-160M-NI SwitchBlock Cable

SCXI -1104/C. Contents CALIBRATION PROCEDURE. For NI-DAQmx

NI PXI/PXIe/PCI Contents GETTING STARTED GUIDE. 14-Bit, 100 MS/s PXI Oscilloscope

USER GUIDE I/O Accessory For the NI PCIe-8237R GigE Vision Interface Device

NI PXIe-5160/5162. Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. 10-Bit Oscilloscope

GETTING STARTED GUIDE NI Ch 24 V Sinking DI, 8-Ch 24 V Sourcing DO SIL3 Capable

Introduction... 1 System Diagram... 2 Hardware... 2 Powering the Hardware... 3 Wiring Harness... 5

NI REM Remote I/O Overview DATASHEET. Analog Output Module for Remote I/O

Reconfigurable Embedded Chassis with Integrated Intelligent Real- Time Controller for CompactRIO

LabVIEW FPGA Module Version 2013

GETTING STARTED NI SMD-7613/7614/7615/7616 Stepper Drives and NI 9512 C Series Modules

NOTE TO USERS NI 61xx Pinout Labels for the SCB-68 Multifunction I/O S Series Modules/Devices Using the 68-Pin Shielded Connector Block

Installation and Configuration Guide

SCXI -1102/B/C. Contents CALIBRATION PROCEDURE. For NI-DAQmx

Contents. Software Requirements CALIBRATION PROCEDURE NI TB-4353

To access NI 5105 documentation, navigate to Start»All Programs»National Instruments» NI-SCOPE»Documentation.

Transcription:

USER MANUAL NI crio-9064 Embedded Real-Time Controller with Reconfigurable FPGA for C Series Modules This document describes the features of the NI crio-9064 and contains information about mounting and operating the device. RJ-45 Ethernet1 RJ-45 Ethernet2 GigE MAC/PHY GigE MAC/PHY RGMII RGMII Xilinx Zynq-7000 XC7Z020 All-Programmable SoC ONFI 1 GB NAND Flash 512 MB DDR3 USB 2.0 Host Port USB 2.0 Device Port + + RS-232 Serial Port C Series Module C Series Module NI crio-9064 Hardware Data Contents Configuring the crio-9064... 2 Connecting the crio-9064 to the Host Computer or Network Using Ethernet... 2 Configuring Startup Options...3 crio-9064 Features... 4 Ports and Connectors... 4 Buttons... 9 LEDs...11 Chassis Grounding Screw... 13 Internal Real-Time Clock...14 Battery...14 File System...14

Mounting the Device...15 Dimensions...16 Mounting Requirements...16 Ambient Temperature...17 Mounting the Device Directly on a Flat Surface... 18 Mounting the Device on a Panel... 19 Mounting the Device on a DIN Rail... 21 Mounting the Device on a Rack...22 Mounting the Device on a Desktop...22 Worldwide Support and Services... 25 Configuring the crio-9064 You can connect the crio-9064 to a host computer or network and configure the startup options using the USB device port or the RJ-45 Gigabit Ethernet port 1. Tip Refer to the getting started guide on ni.com/manuals for basic configuration instructions and information about connecting to a host computer using the USB device port. NI recommends using the USB device port for configuration, debug, and maintenance. Connecting the crio-9064 to the Host Computer or Network Using Ethernet Complete the following steps to connect the crio-9064 to a host computer or Ethernet network using the RJ-45 Gigabit Ethernet port 1. NI recommends using the RJ-45 Gigabit Ethernet port 1 for communication with deployed systems. Note You can configure the RJ-45 Gigabit Ethernet port 2 in Measurement & Automation Explorer (MAX) under the Network Settings tab. 1. Power on the host computer or Ethernet hub. 2. Connect the RJ-45 Gigabit Ethernet port 1 on the crio-9064 to the host computer or Ethernet hub using a standard Category 5 (CAT-5) or better shielded, twisted-pair Ethernet cable. Caution To prevent data loss and to maintain the integrity of your Ethernet installation, do not use a cable longer than 100 m (328 ft). The crio-9064 attempts to initiate a DHCP network connection the first time you connect using Ethernet. The crio-9064 connects to the network with a link-local IP address with the form 169.254.x.x if it is unable to initiate a DHCP connection. Finding the crio-9064 on the Network (DHCP) Complete the following steps to find the crio-9064 on a network using DHCP. 1. Disable secondary network interfaces on the host computer, such as a wireless access card on a laptop. 2 ni.com NI crio-9064 User Manual

2. Ensure that any anti-virus and firewall software running on the host computer allows connections to the host computer. Note MAX uses UDP 44525. Refer to the documentation of your firewall software for information about configuring the firewall to allow communication through the UDP 44525. 3. Launch MAX on the host computer. 4. Expand Remote Systems in the configuration tree and locate your system. Tip MAX lists the system under the model number followed by the serial number, such as NI-cRIO-9064-1856AAA. Configuring Startup Options Complete the following steps to configure the crio-9064 startup options in MAX. 1. In MAX, expand your system under Remote Systems. 2. Select the Startup Settings tab to configure the startup settings. crio-9064 Startup Options You can configure the following crio-9064 startup options. Table 1. crio-9064 Startup Options Startup Option Description Force Safe Mode Rebooting the crio-9064 with this setting on starts the crio-9064 without launching LabVIEW Real-Time or any startup applications. In safe mode, the crio-9064 launches only the services necessary for updating configuration and installing software. Enable Console Out Disable RT Startup App Rebooting the crio-9064 with this setting on redirects the console output to the RS-232 serial port. You can use a serial-port terminal program to read the IP address and firmware version of the crio-9064. Use a nullmodem cable to connect the RS-232 serial port to a computer. Make sure that the serial-port terminal program is configured to the following settings: 115,200 bits per second Eight data bits No parity One stop bit No flow control Rebooting the crio-9064 with this setting on prevents any LabVIEW startup applications from running. NI crio-9064 User Manual National Instruments 3

Table 1. crio-9064 Startup Options (Continued) Startup Option Disable FPGA Startup App Description Rebooting the crio-9064 with this setting on prevents autoloading of any FPGA application. Note When you reset the crio-906x controller either programmatically or by using the RESET button, you also reset the FPGA. All FPGA I/O lines are tri-stated after a reset, and will enter predefined states once loaded. Enable Secure Shell (SSH) Logins Rebooting the crio-9064 with this setting on starts sshd on the crio-9064. Starting sshd enables logins over SSH, an encrypted communication protocol. Note Visit ni.com/info and enter the Info Code openssh for more information about SSH. LabVIEW Project Access Rebooting the crio-9064 with this setting on enables you to add the target to a LabVIEW project. crio-9064 Features The crio-9064 provides the following features. Ports and Connectors The crio-9064 provides the following ports and connectors. 4 ni.com NI crio-9064 User Manual

Figure 1. crio-9064 Ports and Connectors 1 2 3 4 6 5 1. USB Device Port 2. RS-232 Serial Port 3. RJ-45 Ethernet Port 2 4. RJ-45 Ethernet Port 1 5. USB Host Port 6. Power Connector RJ-45 Gigabit Ethernet Ports The crio-9064 has two tri-speed RJ-45 Gigabit Ethernet ports. By default, both Ethernet ports are enabled and configured to obtain an IP address automatically. The Ethernet ports can be configured in MAX. The following table shows the pinout for the RJ-45 Gigabit Ethernet ports. NI crio-9064 User Manual National Instruments 5

Table 2. RJ-45 Gigabit Ethernet Port Pinout Fast Ethernet Signal Gigabit Ethernet Signal Pin Pinout TX+ TX_A+ 1 TX- TX_A- 2 RX+ RX_B+ 3 No Connect TX_C+ 4 No Connect TX_C- 5 RX- RX_B- 6 No Connect RX_D+ 7 1 2 3 4 5 6 7 8 No Connect RX_D- 8 Note Both Ethernet ports perform automatic crossover configuration so you do not need to use a crossover cable to connect to a host computer. The following NI Ethernet cables are available for the crio-9064. Table 3. RJ-45 Gigabit Ethernet Cables Cables Length Part Number CAT-5E Ethernet Cable, shielded 2 m 151733-02 5 m 151733-05 10 m 151733-10 Related Information Ethernet LED Indicators on page 13 Power Connector The crio-9064 has a power connector to which you can connect a power supply. The following table shows the pinout for the power connector. Table 4. Power Connector Pinout Pinout Pin Description V C V C Power input Common 6 ni.com NI crio-9064 User Manual

The crio-9064 has reverse-voltage protection. The following NI power supplies and accessories are available for the crio-9064. Table 5. Power Accessories Accessory Part Number NI PS-10 Desktop Power Supply, 24 VDC, 5 A, 100-120/200-240 VAC Input 782698-01 NI PS-14 Industrial Power Supply, 24 to 28 VDC, 3.3 A, 100-240 VAC Input 783167-01 NI PS-15 Industrial Power Supply, 24 to 28 VDC, 5 A, 100/230 VAC Input 781093-01 NI PS-16 Industrial Power Supply, 24 to 28 VDC, 10 A, 115/230 VAC Input 781094-01 NI PS-17 Industrial Power Supply, 24 to 28 VDC, 20 A, 85-276 VAC Input 781095-01 Related Information POWER LED Indicators on page 11 RS-232 Serial Port The crio-9064 has an RS-232 serial port to which you can connect devices such as displays or input devices. Use the Serial VIs to read from and write to the serial port. Refer to the LabVIEW Help for information about the Serial VIs. Find examples on how to use NI-Serial or NI-VISA to perform serial communication in the NI Example Finder. The NI Example Finder is located on the Help menu in the LabVIEW Help. Note The RS-232 serial port cannot be accessed by the user application when the Console Out startup option is enabled. The following table shows the pinout for the RS-232 serial port. NI crio-9064 User Manual National Instruments 7

Table 6. RS-232 Serial Port Pinout Pinout Pin Signal 1 DCD 2 RxD 3 TxD 6 7 8 9 1 2 3 4 5 4 DTR 5 GND 6 DSR 7 RTS 8 CTS 9 RI Table 7. RS-232 Serial Port Accessories Accessory Length Part Number RS-232, Null-Modem Serial Cable, 9-Pin DSUB (Female) to 9-Pin DSUB (Female) 1 m 182238-01 2 m 182238-02 4 m 182238-04 USB Host Ports The USB host ports on the crio-9064 support common USB mass-storage devices such as USB Flash drives, USB-to-IDE adapters, keyboards, mice, and USB cameras. Caution Do not hot-swap USB devices while the crio-9064 is in a hazardous location or connected to high voltages. If the crio-9064 is not in a hazardous location, you can connect and disconnect USB devices without affecting operation. The following table shows the pinout for the USB host ports. Table 8. USB Host Port Pinout Pinout Pin Signal Description 1 VCC Cable power (5 V) 4 3 2 1 2 D- USB data- 3 D+ USB data+ 4 GND Ground The following NI cable is available for the crio-9064. 8 ni.com NI crio-9064 User Manual

Table 9. USB Host Port Cable Cable Length Part Number USB Extension with Retention, Type A Connectors 0.5 m 152166-0R5 Related Information File System on page 14 2 m 152166-02 USB Device Port The crio-9064 USB device port is intended for device configuration, application deployment, debugging, and maintenance. For example, you can use the USB device port to install software or driver updates during field maintenance instead of interrupting communication on the RJ-45 Ethernet ports. Caution Do not hot-swap USB devices while the crio-9064 is in a hazardous location or connected to high voltages. If the crio-9064 is not in a hazardous location, you can connect and disconnect USB devices without affecting operation. The following table shows the pinout for the USB device port. Description Signal Pin Pinout Pin Signal Description USB data+ D+ 3 3 4 2 1 2 D- USB data- Ground GND 4 1 VCC Cable power (5 V) The following NI cable is available for the crio-9064. Table 10. USB Device Port Cable Cable Length Part Number NI Locking USB Cable 1 m 157788-01 Buttons The crio-9064 provides the following buttons. NI crio-9064 User Manual National Instruments 9

Figure 2. crio-9064 Buttons 1 1. RESET Button RESET Button Press the RESET button to reset the processor in the same manner as cycling power. Troubleshooting Network Connectivity You can use the RESET button to troubleshoot network connectivity. Complete the following steps to reset the network adapters to default settings. 1. Hold the RESET button for 5 seconds, and then release it to boot the controller in safe mode and enable Console Out. 2. Hold the RESET button again for 5 seconds to boot the controller into safe mode, enable Console Out, and reset network adapters to default settings. System Reset The following figure shows the reset behavior of the crio-9064. 10 ni.com NI crio-9064 User Manual

Figure 3. Reset Button Behavior Press and hold RESET button for < 5 s Run Mode Press and hold RESET button for 5 s Press and hold RESET button for < 5 s Safe Mode Console Out enabled RT Startup App disabled FPGA Startup App disabled Press and hold RESET button for 5 s Press and hold RESET button for < 5 s Safe Mode Console Out enabled Network settings reset RT Startup App disabled FPGA Startup App disabled Press and hold RESET button for 5 s LEDs The crio-9064 provides the following LEDs. Figure 4. crio-9064 LEDs 1 2 3 4 5 5 1. POWER LED 2. STATUS LED 3. USER1 LED 4. USER FPGA1 LED 5. RJ-45 Ethernet LEDs POWER LED Indicators The following table lists the POWER LED indicators. NI crio-9064 User Manual National Instruments 11

Table 11. POWER LED Indicators LED Pattern Solid Off The crio-9064 is powered on. The crio-9064 is powered off. Indication STATUS LED Indicators The following table describes the STATUS LED indicators. Table 12. STATUS LED Indicators LED Pattern Blinks twice and pauses Indication The crio-9064 is in safe mode. Software is not installed, which is the factory default state, or software has been improperly installed on the crio-9064. An error can occur when an attempt to upgrade the software is interrupted. Reinstall software on the crio-9064. Refer to the Measurement & Automation Explorer (MAX) Help for information about installing software on the crio-9064. Blinks three times and pauses The crio-9064 is in user-directed safe mode, or the crio-9064 is in install mode to indicate that software is currently being installed. This pattern may also indicate that the user has forced the crio-9064 to boot into safe mode by pressing the reset button for longer than five seconds or by enabling safe mode in MAX. Refer to the Measurement & Automation Explorer (MAX) Help for information about safe mode. Blinks four times and pauses Continuously blinks On momentarily Off The crio-9064 is in safe mode. The software has crashed twice without rebooting or cycling power between crashes. The crio-9064 has not booted into NI Linux Real-Time. The crio-9064 either booted into an unsupported operating system, was interrupted during the boot process, or detected an unrecoverable software error. The crio-9064 is booting. No action required. The crio-9064 is in run mode. Software is installed and the operating system is running. 12 ni.com NI crio-9064 User Manual

User LEDs You can define the USER1 and USER FPGA1 LEDs to meet the needs of your application. The following table lists the USER1 and USER FPGA1 LED indicators. Table 13. User LEDs LED LED Color Description USER1 Green Use LabVIEW Real-Time to define the USER1 LED with the RT LEDs VI. For more information about the RT LEDs VI, refer to the LabVIEW Help. USER FPGA1 Green Use the LabVIEW FPGA Module and NI-RIO Device Drivers software to define the USER FPGA1 LED. Use the USER FPGA1 LED to help debug your application or retrieve application status. Refer to the LabVIEW Help for information about programming this LED. Ethernet LED Indicators The following table lists the Ethernet LED indicators. Table 14. Ethernet LED Indicators LED LED Color LED Pattern Indication ACT/LINK Off LAN link not established Green Solid LAN link established Flashing Activity on LAN 10/100/1000 Yellow Solid 1,000 Mbit/s data rate selected Green Solid 100 Mbit/s data rate selected Off 10 Mbit/s data rate selected Chassis Grounding Screw The crio-9064 provides a chassis grounding screw. NI crio-9064 User Manual National Instruments 13

Figure 5. crio-9064 Chassis Grounding Screw 1 1. Chassis grounding screw For EMC compliance, you must connect the crio-9064 to earth ground through the chassis ground screw. Use wire that is 2.1 mm 2 (14 AWG) solid copper wire with a maximum length of 1.5 m (5 ft). Attach the wire to the earth ground of the electrode system of the facility. Caution If you use shielded cabling to connect to a C Series module with a plastic connector, you must attach the cable shield to the chassis grounding terminal using 2.1 mm 2 (14 AWG) or larger wire. Attach a ring lug to the wire and attach the wire to the chassis grounding terminal. Solder the other end of the wire to the cable shield. Use shorter wire for better EMC performance. For more information about ground connections, visit ni.com/info and enter the Info Code emcground. Internal Real-Time Clock The crio-9064 contains an internal real-time clock that maintains system time when the crio-9064 is powered off. The system clock of the crio-9064 is synchronized with the internal real-time clock at startup. You can set the real-time clock using MAX, or you can set the clock programmatically using LabVIEW. Refer to the specifications on ni.com/manuals for the real-time clock accuracy specifications. Battery The crio-9064 contains a lithium cell battery that stores the system clock information when the crio-9064 is powered off. There is only a slight drain on the battery when power is applied to the crio-9064 power connector. The rate at which the battery drains when power is disconnected depends on the ambient storage temperature. For longer battery life, store the crio-9064 at a cooler temperature and apply power to the power connector. Refer to the specifications on ni.com/manuals for the expected battery lifetime. The battery is not user-replaceable. If you need to replace the battery, contact NI. Refer to the specifications on ni.com/manuals for information about battery disposal. File System LabVIEW mounts USB devices to the media/sdx1 directory and creates symbolic links /u, /v, /w, or /x to the media mount point, starting with /u if it is available. To prevent any file corruption to external storage devices, verify that any file IO operations with the specific drive finish before removing the device. Refer to the LabVIEW Help for more information. 14 ni.com NI crio-9064 User Manual

The file system of the crio-9064 follows conventions established for UNIX-style operating systems. Other LabVIEW Real-Time targets follow Microsoft Windows-style conventions. In order to facilitate the porting of applications from those targets, this target supports the Windows-style /C home directory. This path is bound to the UNIX-style directory /home/ lvuser. Various LabVIEW Real-Time system files which would be accessible from C: (or /C) on other LabVIEW Real-Time targets are found in different locations on this target. UNIX-style file systems support the concept of a symbolic link, which allows access to a file using an alternative file path. For example, it is possible to link /C/ni-rt/system, where dynamic libraries are deployed on other LabVIEW Real-Time targets, to /usr/local/lib, where they are stored on the crio-9064, if the application requires this. For more information, visit ni.com/info and enter the Info Code RT_Paths. Mounting the Device To obtain the maximum allowable ambient temperature of 55 C, you must mount the crio-9064 horizontally on a flat, metallic, vertical surface such as a panel or wall. You can mount the crio-9064 directly to the surface or use the NI Panel Mounting Kit. The following figure shows the crio-9064 mounted horizontally. Figure 6. crio-9064 Horizontal Mounting 1 1. Up You can also mount the crio-9064 in other orientations, on a nonmetallic surface, on a 35-mm DIN rail, on a desktop, or in a rack. Mounting the crio-9064 in these or other configurations can reduce the maximum allowable ambient temperature and can affect the typical accuracy of modules in the crio-9064. For more information about typical accuracy specifications for C Series modules and temperature deratings caused by different mounting configurations, visit ni.com/info and enter the Info Code criotypical. Caution Make sure that no C Series modules are in the crio-9064 before mounting it. Tip Before using any of these mounting methods, record the serial number from the back of the crio-9064 so that you can identify the crio-9064 in MAX. You will be unable to read the serial number after you mount the crio-9064. NI crio-9064 User Manual National Instruments 15

Dimensions The following figures show the front and side dimensions of the crio-9064. For detailed dimensional drawings and 3D models, visit ni.com/dimensions and search for the module number. Figure 7. crio-9064 Front Dimensions 87.3 mm (3.44 in.) 178.1 mm (7.01 in.) 4.1 mm (0.16 in.) Figure 8. crio-9064 Side Dimensions 44.1 mm (1.74 in.) 29.1 mm (1.15 in.) 44.1 mm (1.73 in.) 14.1 mm (0.55 in.) Mounting Requirements Your installation must meet the following requirements for cooling and cabling clearance. Allow 25.4 mm (1.00 in.) on the top and the bottom of the crio-9064 for air circulation, as shown in the following figure. 16 ni.com NI crio-9064 User Manual

Figure 9. crio-9064 Cooling Dimensions 25.4 mm (1.00 in.) 25.4 mm (1.00 in.) Allow the appropriate space in front of C Series modules for cabling clearance, as shown in the following figure. The different connector types on C Series modules require different cabling clearances. For a complete list of cabling clearances for C Series modules, visit ni.com/info and enter the Info Code crioconn. Figure 10. crio-9064 Cabling Clearance Cabling Clearance 50.8 mm (2.00 in.) 29.1 mm (1.14 in.) 50.8 mm (2.00 in.) Ambient Temperature Measure the ambient temperature at each side of the crio-9064, 63.5 mm (2.50 in.) from the side and 25.4 mm (1.00 in.) forward from the rear of the crio-9064, as shown in the following figure. NI crio-9064 User Manual National Instruments 17

Figure 11. crio-9064 Ambient Temperature Location 63.5 mm 63.5 mm 1 (2.50 in.) (2.50 in.) 1 63.5 mm 63.5 mm 1 1 (2.50 in.) (2.50 in.) 25.4 mm (1.00 in.) 25.4 mm (1.00 in.) 1. Location for measuring the ambient temperature Mounting the Device Directly on a Flat Surface For environments with high shock and vibration, NI recommends mounting the crio-9064 directly on a flat, rigid surface using the mounting holes in the crio-9064. What to Use crio-9064 Screwdriver, Phillips #2 M4 or number 8 screw (x2), user-provided, longer than 23.00 mm (0.91 in.) to pass all the way through the crio-9064 What to Do Complete the following steps to mount the crio-9064 directly on a flat surface. 18 ni.com NI crio-9064 User Manual

1. Prepare the surface for mounting the crio-9064 using the Surface Mounting Dimensions. 2. Align the crio-9064 on the surface. 3. Fasten the crio-9064 to the surface using the M4 or number 8 screws appropriate for the surface. Tighten the screws to a maximum torque of 1.3 N m (11.5 lb in.). Surface Mounting Dimensions The following figure shows the surface mounting dimensions for the crio-9064. Figure 12. crio-9064 Surface Mounting Dimensions 47.2 mm (1.86 in.) 30.6 mm (1.20 in.) 47.0 mm (1.85 in.) 41.1 mm (1.62 in.) 4.1 mm (0.16 in.) Mounting the Device on a Panel You can use the NI panel mounting kit to mount the crio-9064 on a panel. NI crio-9064 User Manual National Instruments 19

What to Use crio-9064 Screwdriver, Phillips #2 NI panel mounting kit, 779097-01 Panel mounting plate M5 or number 10 screw (x4) What to Do Complete the following steps to mount the crio-9064 on a panel. 1. Align the crio-9064 and the panel mounting plate. 2. Fasten the panel mounting plate to the crio-9064 using the screwdriver and M5 or number 10 screws. NI provides these screws with the panel mounting kit. Tighten the screws to a maximum torque of 1.3 N m (11.5 lb in.). Note You must use the screws provided with the NI panel mounting kit because they are the correct depth and thread for the panel mounting plate. 3. Fasten the panel mounting plate to the surface using the screwdriver and screws that are appropriate for the surface. The maximum screw size is M5 or number 10. Panel Mounting Dimensions The following figure shows the panel mounting dimensions for the crio-9064. 20 ni.com NI crio-9064 User Manual

Figure 13. crio-9064 Panel Mounting Dimensions 9.5 mm (0.38 in.) 235.0 mm (9.25 in.) 215.9 mm (8.50 in.) 27.3 mm (1.08 in.) 7.2 mm (0.29 in.) 31.7 mm (1.25 in.) 88.1 mm (3.47 in.) 63.5 mm (2.50 in.) Mounting the Device on a DIN Rail You can use the NI DIN rail mounting kit to mount the crio-9064 on a standard 35-mm DIN rail. What to Use crio-9064 Screwdriver, Phillips #2 NI DIN rail mounting kit, 779019-01 DIN rail clip M4 25 flathead screw (x2) What to Do Complete the following steps to mount the crio-9064 on a DIN rail. 1. Align the crio-9064 and the DIN rail clip. NI crio-9064 User Manual National Instruments 21

2. Fasten the DIN rail kit to the crio-9064 using the screwdriver and M4 25 flathead screws. NI provides these screws with the DIN rail mounting kit. Tighten the screws to a maximum torque of 1.3 N m (11.5 lb in.). Note You must use the screws provided with the NI DIN rail mounting kit because they are the correct depth and thread for the DIN rail clip. Clipping the Device on a DIN Rail Complete the following steps to clip the crio-9064 on a DIN rail. 2 1 1. Insert one edge of the DIN rail into the deeper opening of the DIN rail clip. 2. Press down firmly to compress the spring until the clip locks in place on the DIN rail. Caution Ensure that no C Series modules are in the crio-9064 before removing it from the DIN rail. Mounting the Device on a Rack You can use the following rack mount kits to mount the crio-9064 and other DIN railmountable equipment on a standard 482.6 mm (19 in.) rack. NI Sliding Rack-Mounting Kit, 779102-01 NI Rack-Mounting Kit, 781989-01 Note You must use the NI DIN rail mounting kit, 779019-01, in addition to a rackmounting kit. Mounting the Device on a Desktop You can use the NI desktop mounting kit to mount the crio-9064 on a desktop. What to Use crio-9064 Screwdriver, Phillips #1 Screwdriver, Phillips #2 NI desktop mounting kit, 779473-01 22 ni.com NI crio-9064 User Manual

Figure 14. Components of the NI Desktop Mount Kit 1 2 3 4 1. Desktop mounting brackets (x2) 2. Adapter bracket 3. M3x14 screws (x2) 4. M3x20 screws (x2) What to Do Complete the following steps to mount the crio-9064 on a desktop. NI crio-9064 User Manual National Instruments 23

1 2 4 3 3 4 1. Use a #1 Phillips screwdriver to remove the two screws from the back of the chassis on the front-panel side. 2. Use the screwdriver and the two M3x20 screws to attach the adapter bracket to the chassis. 3. Align one of the end brackets with the mounting hole at one of the ends of the chassis. 4. Use a #2 Phillips screwdriver to tighten the captive screw on the end bracket. 5. Repeat steps 2 and 3 to attach the other end bracket to the other end of the chassis. Desktop Mounting Dimensions The following figures show the desktop mounting dimensions for the crio-9064. 24 ni.com NI crio-9064 User Manual

Figure 15. crio-9064 Desktop Mounting Front Dimensions 22.9 mm (1.14 in.) 17.2 mm (0.68 in.) 39.1 mm (1.54 in.) Figure 16. crio-9064 Desktop Mounting Side Dimensions 127.0 mm (5.00 in.) 130.0 mm (5.12 in.) Worldwide Support and Services The NI website is your complete resource for technical support. At ni.com/support, you have access to everything from troubleshooting and application development self-help resources to email and phone assistance from NI Application Engineers. Visit ni.com/services for NI Factory Installation Services, repairs, extended warranty, and other services. Visit ni.com/register to register your NI product. Product registration facilitates technical support and ensures that you receive important information updates from NI. A Declaration of Conformity (DoC) is our claim of compliance with the Council of the European Communities using the manufacturer s declaration of conformity. This system affords the user protection for electromagnetic compatibility (EMC) and product safety. You can obtain the DoC for your product by visiting ni.com/certification. If your product supports calibration, you can obtain the calibration certificate for your product at ni.com/calibration. NI crio-9064 User Manual National Instruments 25

NI corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas, 78759-3504. NI also has offices located around the world. For telephone support in the United States, create your service request at ni.com/support or dial 1 866 ASK MYNI (275 6964). For telephone support outside the United States, visit the Worldwide Offices section of ni.com/ niglobal to access the branch office websites, which provide up-to-date contact information, support phone numbers, email addresses, and current events. Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for information on NI trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering NI products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents. You can find information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer to the Export Compliance Information at ni.com/ legal/export-compliance for the NI global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015. 2016 National Instruments. All rights reserved. 376508B-01 Jun16