UPGRADE PROGRAM. V70 Series Pumps vs V81T Series Pumps

Similar documents
UPGRADE PROGRAM. V250 Series Pumps vs V301 Series Pumps. Technical Memo

Varian, Inc. Vacuum Technologies. The New Unique Varian Dry Turbo Pumping System: TPS-compact

HiPace 10 with TC 110 and power supply pack OPS 40, DN 25

HiPace Turbopumps. The HiPace TM Innovation. Picking Up the Pace in Vacuum Technology! Faster. Higher. Stronger. idealvac.

Thermal Diffusivity Instruments DLF-2 with EM-1600

MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH

February Instruction Manual. TURBO V80 controller. Model Model I. )

Instruction Manual. B Issue A Original. next Turbomolecular Pumps next240, next300 and next400

SonoSelect and SonoSafe energy meters

TiTan Ion pumps (MINI - 75S) (100L LX) (150TV - 600TV)

Old documentation - Only for your information! Product is not available anymore!

SonoSelect 10 and SonoSafe 10 energy meters

MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH

Best in class leak detector for high reliability testing in various applications, using helium and hydrogen

MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH

The VARIO Chemistry-pumping units with adaptive vacuum control

red-y industrial series product information Thermal Mass Flow Meters and Controllers for Gases with IP67 & Ex Protection

Built-in features Built-in simplicity Built for fans & pumps

Model VDL 115 Vacuum drying chambers for flammable solvents

FOX-50 Heat Flow Meter

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

SED2 VFD NEMA Type 3R Bypass/Air Conditioner

shop online:

Easy Flow Indicator Magnetisch-Induktiver Durchflussmesser. Type 8024 For Insertion Fittings. Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI

A 101 A B C. Variable flow-control valve, series DXC. Dynamic Flow Networking. Description. Content

Filter Fan Unit LIGHT

UNIDRIVE M200. Manufacturing Automation drives. Flexible machine integration through communications

Level gauges Series LS Level indicator, switch and transmitter for liquids

Chiller. CG 010 to 130. Remote Air Cooled Condensers Engineering Data Manual. 9.4 to 131 kw

Flowtronic D 607 Series

4/8/ nd Annual OTCO WW Workshop W/WW Product Overview ACQ550. ABB Slide 1

Ku-Band Solid-State Power Amplifier

IBM Symposium Data Center Cooling. EC Systems for HVAC architecture and Direct air Cabinet Cooling

IK4A (with ONDA technology)

Freely programmable Pick & Place HP 140T. Technology that inspires

edwardsvacuum.com nxds DRY SCROLL PUMPS

5/2 and 5/3 Directional-control valves, Series TC 15, G 1/4

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

CHILI Vacuum Control Unit Changes compared to the previous version are shown in green.

C-Band Solid-State Power Amplifiers

Ultra High Vacuum Pumps

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

Double solenoid valve Combined pressure regulator and safety valves Servo pressure regulator MBC-...-SE DN 65 - DN 100

21023, 21025, 2/2 Direct solenoid actuated poppet valves

1551 S. Harris Court,. Anaheim, CA Phone: Fax:

200 mm Semi-automated Probe System with BlueRay Technology

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

red-y industrial series Thermal Mass Flow Meters and Controllers for Gases

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

Double solenoid valve Combined pressure regulator and safety valves Servo pressure regulator MBC-...-SE DN 65 - DN 125

Operating pressure (bar) kv factor (m 3 /h) *3)

DMT PERFORMING UNDER PRESSURE DMT. Applications. Special features. Description 1/9

Granville-Phillips Micro-Ion Plus Modules

Analog electric proportional joysticks JEP

accurate measurement of compressed air consumption and leakage detection Calibration certificates and continous calibration, OEKD calibration service

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

MPI TS150-HP 150 mm High Power Manual Probe System For accurate High Power measurements up to 10 kv, 600 A

Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems

Flow VA 500/

Discovery SDT650. Site Preparation Guide. Revision A Issued March Page 1

High-end pressure controller Model CPC8000

Discovery Hybrid Rheometer

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

VARIABLE SPEED DRIVES

Edge CDG025D2 with EtherCAT Torr / mbar

EW773 Series Ultrasonic Hydronic Meters FOR HEATING AND COOLING APPLICATIONS

USER S MANUAL. TurboCharger Analyser Compact

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

Flow. Flow. N/en

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

VLT Micro Drive. Ready Set Go!

System Overview. Liquid Cooling for Data Centers. Negative Pressure Cooling Without Risk of Leaks

IN-LINE. vpinstruments.com

Digital Indicator Solutions

Radiator Valves. Building Technologies HVAC Products. NF norm, for 2-pipe heating systems

Electronic SD1, AS 8, ASR 14, ASR 20

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

G 1/2 30,5 A Brass NBR 0,8 3,

Nano DSC and MCDSC. Site Preparation Guide

PSG55x ATM to Medium Vacuum Gauge

IS-3000-LS-ABB INFRARED SCANNER

Asynchronous motors. 5/48 Permissible combinations of mechanical designs for 1PL6 motors,

HYGROPHIL-F, Moisture Analyzer, Type , -11, -12, -13 series A

SB200. VSV V/F Control Inverter. High-performance. Applications General pump & fan control HVAC Industrial motor control

Vibration Switches viib

B 201 A B C. dynamx variable flow-control valves, series DXMB_C. Dynamic Flow Networking. Description. Content

Features. Conducted Emission. Radiated Emission. Line Regulation. Load Regulation. Safety. Cooling. Input Connectors.

DIMENSION/WEIGHT kpa. 0 to 20 m / 0 to 60 ft 0 to 2 bar / 0 to 29 psi. 0 to 50 m / 0 to 160 ft 0 to 5 bar / 0 to 72.5 psi

ATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp)

PCG55x ATM to Medium Vacuum Gauge

EE771 Series. Flowmeter for compressed air and gases in Industrial Applications. EE771 Compact. EE771 remote probe

CHILI Vacuum Control Unit

Electropneumatic miniature control valves Mounting Connectors Minisolenoid valves Indicators LED seals LED Valve modules Poppet 3/2 single pilot 4/2 s

Features. Conducted. Emission. Line Regulation. Load Regulation. Safety. Cooling. Input Connectors. Overvoltage Protection. Phase Loss.

Screw-Type Flow Meter SVC

Brushless Motor with Integral Drive EnduraMax 95i Series

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

Fan Tray Unit UEL03M User Manual

Transcription:

VARIAN vacuum technologies UPGRADE PROGRAM V70 Series Pumps vs V81T Series Pumps Technical Memo Technical Memo - 1 - V70 series vs V81-T

INDEX Outline drawings ISO63 3 Outline drawings CF2-¾ 4 Outline Drawing KF40 5 Outline drawings CF 4-½ 6 Technical Specification 9 Technical Advantages 10 Accessories 10 Controller comparison 11 Outline Drawing 14 Technical Memo - 2 - V70 series vs V81-T

Outline Drawing ISO63 V70 ISO63 9699357 Replacement Suggested V81-T ISO63 EX9698905 Technical Memo - 3 - V70 series vs V81-T

Outline Drawing CF2¾ V70 CFF 2-¾ 9699360 Replacement Suggested V81-T CFF 2-¾ EX9698908 Technical Memo - 4 - V70 series vs V81-T

Outline Drawing KF40 V70 KF40 9699359 Replacement Suggested V81-T KF40 EX9698906 Technical Memo - 5 - V70 series vs V81-T

Outline Drawing CF 4-½ V70 CFF 4-½ 9699358 Replacement Suggested V81-T CFF 4-½ EX9698907 Technical Memo - 6 - V70 series vs V81-T

Technical Tables V70 ISO63 V81-T ISO63 Total height 133.9 128.68 Vent port height from bottom 90.8 80.0 Foreline port height fm. bottom 39.9 37.5 Vent thread M5 M8 Purge thread Only S001 version Only MSP* version Water fitting thread 1/8 G Plate with 1/8G Inlet flange ISO63 ISO63 Foreline Flange KF16 KF16 Vent port position referring to Foreline Flange 180 180 * for pump with purge port, please contact Marketing for special quotation V70 CFF 2 ¾ V81-T CFF 2-¾ Total height 150.1 145.8 Vent port height from bottom 78.4 73.0 Foreline port height fm. bottom 39.9 37.5 Vent thread M5 M8 Purge thread Only S001 version Only MSP* version Water fitting thread 1/8 G Plate with 1/8G Technical Memo - 7 - V70 series vs V81-T

Inlet flange CFF 2 ¾ CFF 2 ¾ Foreline Flange KF16 KF16 Vent port position referring to Foreline Flange 180 180 * for pump with purge port, please contact Marketing for special quotation V70 KF40 V81-T KF40 Total height 150.1 145.8 Vent port height from bottom 90.8 80.0 Foreline port height fm. bottom 39.9 37.5 Vent thread M5 M8 Purge thread Only S001 version Only MSP* version Water fitting thread 1/8 G Plate with 1/8G Inlet flange KF 40 KF 40 Foreline Flange KF16 KF16 Vent port position referring to Foreline Flange 180 180 * for pump with purge port, please contact Marketing for special quotation V70 CFF 4½ V81-T CFF 4½ Total height 132.9 128.6 Vent port height from bottom 78.4 73.0 Foreline port height fm. bottom 39.9 37.5 Vent thread M5 M8 Purge thread Only S001 version Only MSP* version Water fitting thread 1/8 G Plate with 1/8G Inlet flange CFF 4 ½ CFF 4 ½ Foreline Flange KF16 KF16 Vent port position referring to Foreline Flange 180 180 * for pump with purge port, please contact Marketing for special quotation Technical Specification: Pumping Speed Curve: V70 ISO63 Technical Memo - 8 - V70 series vs V81-T

V81 ISO63 Technical Specifications Connection nominal diameter Inlet Outlet Pumping speed l/s N2 He H2 Compression ration for N2 He H2 ISO63 CFF4 ½ CFF 2 ¾ KF40 NW16KF 68 60 45 5x10e+7 4x10e+3 4x10e+2 V70 ISO63 CFF4½ CFF 2 ¾ KF40 NW16KF 77 65 50 >7x10e+6 3x10e+3 3x10e+2 V81 Max Forevacuum pressure mbar 10e-1 mbar range 0.2 mbar (N2) Technical Memo - 9 - V70 series vs V81-T

Recommended baking pump Rotary Dry Ultimate pressure mbar With rotary With dry DS102 SH100 1x10e-9 9x10e-9 (CFF) DS102 SH110 < 5x10e-10 <5x10e-9 Rotational speed 75000 80000 Run up time min. < 60 sec < 60 sec Cooling Air (optional water) Air (optional water) Coolant water Flow: 10 l/h Temp: +10 C to 30 C Press: 2-4 bar Power consumption W 150 100 Flow: 10 l/h Temp: +15 C to 35 C Press: 2-4 bar Vibration level < 0.01 µm at inlet flange < 0.01 µm at inlet flange (displacement) Noise level < 45 db (A) at 1 meter < 45 db (A) at 1 meter Motor technology Asynchronous Asynchronous input 54 Vac, three phase, 1250 Hz Weight Kg ISO 63 1.6 CFF 4 ½ 2.3. Operating position Any Any 76 Vac, three phase, 1350 Hz ISO 63 1.8 CFF 4 ½ 2.6 Technical Advantages The Turbo-V 81-T pump has been designed in order to have the same performances of the present TV70 but in a smaller package. It has been designed according to the technical improvements of the drag pump having, as main target, a cost reduction; furthermore, the fins for air cooling have been optimized and the operating temperatures can be substantially lower, for optimized performances. The most important advantage of the Upgrade is the possibility to replace the standard controller by the AG-Rack V81. The Turbo-V 81-AG Rack Controller will be very innovative and with increased control and communication capabilities. The new rack controller is micro-processor-controlled, solid-state, frequency converter with self-diagnostic and self-protection features. The most important features are: front/remote/serial operation, 24Vdc pump fan cooling drive, vent valve drive (valve delay and opening time are adjustable), pump speed reading after stop command (allows monitoring of pump slow down time Technical Memo - 10 - V70 series vs V81-T

after the stop command during the venting phase), regenerative braking (most effective pump deceleration without heat generation at the motor level), pressure reading through Varian EyeSys Mini-IMG Gauge, input voltage auto setting, remote I/O compatible with previous version, Navigator default serial compatible with the previous RS232 and RS485 version, Profibus interface (optional). The controller is available in three models: base version, with RS232-485 option, with Profibus option. The pump can also been operated by V70 series controllers. The rotational speed will be reduced and consequentially the performances (75 KRPM vs 80 KRPM); should a customer use the V70 Navigator controller attached to the bottom of the pump, a special plate is needed to enable the assembly. Accessories: 1. air cooling kit: V81 series pumps work with natural or forced air (kit pn 9699290 with extension 9699940); V70 fan cannot be installed on V81-T pump. Should the customer keep his V70 controller, a connector-adapter is provided with the new fan kit 2. water cooling kit: the V81-T pump uses a brass plate to be installed on the pump bottom (9699823-9699824) 3. the vent valve to be used depends on the controller for the V81-T pump: should the customer keep his V70 rack controller, the vent valve has pn 9699843; should the customer use the V70 Navigator controller, the vent valve has pn 9699834; should the customer use the V81 AG controller, the vent valve has pn 9699844. 4. inlet screen has not changed (DN63 9699300 or KF40 9699309) Controller Comparison V81 vs V70 The existing V70 series controllers are able to drive a V81-T pump; the rotational speed is limited to 75 KRPM instead of 80 KRPM and consequently the performances. The V70 series controllers can be replaced by the V81 series controllers, that are available in following configurations: 1. V81AG Navigator on Board controller 120-220 V, pn 9698996 2. V81 ¼ AG-Rack controller, pn 9698988 (base), 96989889 (with RS232-485) and 9698990 (with Profibus), with input voltage from 100 V to 240 V V81AG Navigator on board controller Technical Memo - 11 - V70 series vs V81-T

The Turbo-V81-AG Navigator controller is a microprocessor based solid-state frequency converter with new- enhanced features allowing for further improved control and communication capabilities. The Navigator controller can be mounted on the bottom of our TV81-Navigator family of Turbo Molecular Pumps. In order to mount the controller a specific mounting kit is provided together with the controller unit. The units are fully controllable by a remote host computer via the serial connection by means of a Windows based dedicated software. The main improvements and key differences respect to former TV70 Navigator controller (9698970 &9698971) are: 1) Output: Programmable Analog Signal 0-10Vdc Proportional to or Frequency (existing) or Power (existing) or Temperature (new) or pressure (new) 2) Output: Programmable set point (O.C.) or Frequency (existing) or Current (existing) or Time (new) or Pressure (new) 3) Able to read an External Gauge (new Feature) To the new controllers an EyeSys Mini-IMG gauge can be connected by means of its extension cable. (See orderable parts table). The pressure can be read by serial line or by Remote I/O on Programmable analog Out, in this case the controller replicates the signal coming from the gauge. 4) Multilayer 4-Layer PCB design In order to have major Immunity to EMI the new controller PCB has been designed with 4 Layers (former design had 2 layers). This is today s state of the Art electronics design. 5) Internal fan for 24Vdc version In the new 24Vdc controller the improved design allows to work without internal FAN. This new solution eliminates potential vibration issues due to FAN. 6) Connectors The new controller comes with shielded connectors only (DB15, DB9 & USB). This improvement respect to the former Molex type connectors has been introduced in order to reduce eventual Electro Magnetic Interference (EMI) issues. 7) Stop Speed Reading (new feature) This is a new Feature available via RS232 connection. The benefits of this feature are: Technical Memo - 12 - V70 series vs V81-T

Continued reading of pump speed after the STOP command. Allows monitoring of pump slow down and specific shut down time. V81 AG Rack controller The Turbo-V 81-AG Rack Controller will be very innovative and with increased control and communication capabilities. The new rack controller is micro-processor-controlled, solid-state, frequency converter with self-diagnostic and self-protection features. The most important features are: front/remote/serial operation, 24Vdc pump fan cooling drive, vent valve drive (valve delay and opening time are adjustable), pump speed reading after stop command (allows monitoring of pump slow down time after the stop command during the venting phase), regenerative braking (most effective pump deceleration without heat generation at the motor level), pressure reading through Varian EyeSys Mini- IMG Gauge, input voltage auto setting, remote I/O compatible with previous version, Navigator default serial compatible with the previous RS232 and RS485 version, Profibus interface (optional). The controller is available in three models: base version, with RS232-485 option, with Profibus option. Advantages The advantages are listed below: valve delay and opening time are adjustable (it was fixed on V70 rack controller) pump speed reading after stop command (not available on V70 controller) regenerative braking (not available on V70 controller) pressure reading through Varian EyeSys Mini-IMG Gauge (not available on V70 controller) input voltage auto setting (manually selectable on V70 rack controllers) remote I/O compatible with previous version Profibus interface (optional) Navigator default serial compatible with the previous RS232 and RS485 version Technical Memo - 13 - V70 series vs V81-T

Controller outline: V81 Navigator on board: Technical Memo - 14 - V70 series vs V81-T

V81 ¼ rack Main cable is supplied; controller-to-pump cable is supplied. Please refer to the Instruction Manual for further technical details (accessories connections, vent valve driving, RS232 protocol, Eyesy Mini IMG operation, etc). Technical Memo - 15 - V70 series vs V81-T