U1602, U1603 ENERGY CONTROL SYSTEM

Similar documents
A2000 Multifunctional Power Meter

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

PROFITEST Tester for DIN EN and VDE 0113

PROFITEST PV Peak Power Measuring Instrument and Curve Tracer for PV Modules and Strings (Measurement at Capacitive Load)

DINALOG A 144 x 36 A1400 Light-Strip Indicator

METRAtest 36ASi AS Interface System Tester

MIC-2 MKII, Multi-instrument DATA SHEET

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

MIC-2 Multi-instrument DATA SHEET

PROFITEST Tester for DIN EN and VDE 0113

PXR11 PXR12. System controllers DESIGO PX

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

Installation Instructions VIPA FM355 / R355. 4/8-Channel Controller Module for Siemens S7-300 and Vipa System 300V /10.

TM221M16R controller M IO relay

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

MCX08M2 Programmable controller

EngyVolt RV12 and RV15

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

A2000 Multifunctional Power Meter Profibus Interface

Controller module. Brief description. Features. Block structure. Page 1/7. Data Sheet

Manual Industry Interfaces

Multifunction Transducer MT440

Syr-line TMR48D Digital Timer

PSI-MODEM-SHDSL/PB. Broadband PROFIBUS extender, SHDSL PROFIBUS leased line modem. Data sheet _en_03. 1 Description. 1.

Converter Box Data Sheet

SSP-KONSTANTER, Series 62 N and Series 64 N Computer Controlled Laboratory Power Supplies

Millenium 3. General Characteristics. General environment characteristics for CB, CD, XD, XR and XE product types

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D

QUINT-PS/ 1AC/24DC/ 5

Networks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks

Operating Instructions PRO-AB /6.15. Leakage Current Measuring Adapter

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

Temperature controller Ducted systems

M-Bus Central Unit. Use

02/11/2015

TM221CE24R controller M IO relay Ethernet

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

Power supply module, bus connection module

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

PointMaster 100. Multipoint Recorder 10/ EN

02/11/2015

UMG 604. UMG 604 Power analyser. Modbus master, Ethernet gateway. Harmonics. Memory 128 MByte. Homepage. Graphic programming.

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

PSI-MODEM-SHDSL/SERIAL

PRELIMINARY. USB1 / USB2 USB host interface to read data via memory stick. Bus Out (system bus) For connection to a router

Voltage Transducer UMT516 / MT516

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

SYSKON P1500 Computer Controlled Laboratory Power Supply

MINI-PS AC/10-15DC/8

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

Operating Instructions SECUTEST SI /12.10

ISOMETER isopv with coupling device AGH-PV

Manual Fiber Optic Interfaces

TM241C24T controller M IO transistor PNP

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

ISOMETER isoev425 with coupling device AGH420

TM241C40R controller M IO relay

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

Syr-line TMR48D Digital Timer

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet

PHOENIX CONTACT - 07/2006

Strain Gage Measuring Amplifier GSV-3

LINETRAXX RCMS150. Residual current monitor type B with integrated measuring current transformers for earthed AC/DC systems (TN and TT systems)

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Control Panel CP600 CP651, CP651-WEB

USER MANUAL 2012 V1.1

Electronic timer CT-ARS.11

W&T. Universal Fiber Optic Interface Converter W&T. Manual. Universal FO Interface Converter. Model Release 1.0. Subject to error and alteration

TM221M16TG controller M IO transistor PNP spring

MID approval no. DE-08-MI004-PTB004 Date of release

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet

Energy Management Energy Transducer Type ET112

TM221CE40R controller M IO relay Ethernet

Controller module. Brief description. Features. Block structure. Data Sheet Page 1/7

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

TM221CE40T controller M IO transistor PNP Ethernet

DRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

FL MC 2000E (SM40) LC

Contact protection relay

This data sheet is only valid in association with the IL SYS INST UM E user manual.

Control Panel CP600-eCo CP604, CP604-B

TM241C40U controller M IO transistor NPN

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

Plug-in module SIRAX TV 808, 2 channels Isolating Amplifier unipolar/bipolar

Smart Energy & Power Quality Solutions. ProData datalogger. Datalogger and Gateway

JUMO mtron T Measuring, Control, and Automation System

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

Electronic timer CT-AHD.22

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

KONSTANTER SPL Series Programmable Electronic Load

08/07/2015

EZ864 G. Telit Cellular GSM/UMTS Engine. Hardware guide Version: Update: 27. APR.2009 EZ864 G_Hardware Guide_V

Electronic timer CT-ERS.21

Control Panel CP600 CP635, CP635-B, CP635-WEB

Transcription:

3-349-046-03 3/6.09 64 processing channels physical inputs or LON meter outputs can be assigned for the calculation of energy, power and costs Energy Control Language for the programming of analysis, monitoring and optimization applications LON interface for 63 LON devices Two RS 232 interfaces (115 kbit/s) for connection to PC, modem, printer or radio-controlled clock Two ECS LAN interfaces for the linking of individual summators over great distances Simple software update via serial interface (Flash) U1603: 6 universal inputs: ± 5 ma, ± 20 ma, ± 10 V, S0 pulse 2 analog outputs: ± 20 ma or ± 10 V 2 relays and 4 MOS switches for controlling external processes QUALITY MANAGEMENT SYSTEM DQS certified per DIN EN ISO 9001 Reg. No.1262 Applications The U1602 micro-summator and the U1603 mini-summator are used as PC adapters or LON interfaces for the ECS LAN, and are not equipped with any display or operating elements. Inputs and outputs expand the U1603 mini-summator into a miniature data collector and optimization unit. Meter Inputs Up to 63 LON devices can be connected to the U1602 microsummator or the U1603 mini-summator via the easy-to-wire, polarity-reversal-protected, LON interface: Multifunctional power meter A2000 Programmable multi-measuring transducer DME 400 Electricity meter U1681, U1687, U1689, U128x W1, U138x W1 Meter reading module U1660 Analog input module U1661 Relay output module OCL210 by Littwin Analysis All relevant energy and consumption data are logged over defined time periods at a programmable interval via 64 processing channels and are stored to memory as load profiles along with the corresponding maximum values. Beyond this, the U1603 mini-summator is also capable of processing analog or pulse signals via six input channels with configurable parameters. Operation The U1603 is equipped with two analog outputs, four MOS switches and two relays (changeover contacts) for the control of external processes. Data exchange with a PC, as well as remote querying via modem are accomplished via the RS 232 interface (115 kbit / s). A radio-controlled clock for the synchronization of system time, as well as a report printer, can also be connected. Networking Individual summators can be linked into a network over great distances with the multi-master compatible ECS LAN with free selection of network topology, and have unrestricted access to all data available from each of the network users. Universal Application Both the U1602 micro-summator and the U1603 mini-summator are suitable for customer-specific calculations, analyses, monitoring and optimization thanks to integrated high-level intelligence and the system-specific ECL programming language - even independent of the Energy Control System. Variable Installation The compact housing and IP protection have been laid out for rugged industrial use, and the modules can be mounted to tophat rails in accordance with EN50022. They can also be mounted with screws, or integrated into the control cabinet. Installation is user-friendly and easy with plug-in screw terminals. GMC-I Messtechnik GmbH

Applicable Regulations and Standards EN 61010-1 Symbols and their Meanings Safety requirements for electrical equipment for measurement, control and laboratory use DIN 43864 Current interface for pulse transmission between impulse meters and tariff devices VDE 0470 Part 1 IP protection provided by enclosures (DIN 40050) IEC 68 Part 2-6 UL 94 EMC Standards Basic environmental test procedure Sinusoidal oscillation Test for flammability of plastic materials for parts in devices and appliances see Technical Data Power Instantaneous Power P mom Determined from the time interval between the last two pulses (with connection to E1... E12) Mean Values for Measuring Intervals P int For all stored measuring intervals (measurement data list) Maximum Values for Measuring Intervals, with Date and Time Stamp P maxint The 10 highest values from all measuring intervals as of a defined starting time P maxday Maximum value for the current day, and for each of the last 10 days P maxmonth Maximum daily value for the current month, and for each of the last 12 months P maxyear Maximum value for the current year, and for each of the last 4 years Symbol X X2 Y Y2 Meaning Measured quantity, analog input Upper range value of measured quantity Output quantity, analog output Upper range value of output quantity Technical Data Inputs (U1603) The 6 inputs can be configured individually with the DIP switches. Memory Capacities per Channel Energy Cumulative Energy as of a Defined Starting Time E tot Independent of tariff E tot T1 For tariff 1 only E tot T2 For tariff 2 only E tot T1T2 For tariff 1 + tariff 2 Cumulative Energy for Defined Time Periods E Day For current day and each of the last 10 days E Month For current month and each of the last 12 months E Year for current year and each of the last 4 years E Int For all stored measuring intervals (measurement data list) Maximum Values for Measuring Intervals, with Date and Time Stamp E maxint The 10 highest values for all measuring intervals as of a defined starting time E maxday Maximum value for the current day, and for each of the last 10 days E maxmonth Maximum daily value for the current month, and for each of the last 12 months E maxyear Maximum value for the current year, and for each of the last 4 years Costs Cumulative Costs as of a Defined Starting Time CostT1 For tariff 1 only CostT2 For tariff 2 only CostT1T2 For tariff 1 + tariff 2 Analog Input (Current) Input quantity direct current Input range X2 X +X2 Upper range value X2 5 ma/20 ma Max. input current 2.5 X2 Control limit 1.25 X2 Input resistance X2: 20 ma X2: 5 ma Common mode rejection 75 300 80 db ( 120 Hz) Analog Input (Voltage) Input quantity direct voltage Input range X2 X +X2 Upper range value X2 10 V Max. input voltage 30 V Control limit 1.25 X2 Input resistance 118 k Common mode rejection 80 db ( 120 Hz) Binary Input Input quantity direct voltage (square-wave pulses, SO compatible) Operating point (adjustable) signal level: L: 0.5/1.25/2.5/3.5 ma Max. input voltage continuous intermittent (t 1 s) Series impedance (internal) Allowable switching elements Pulse duration T on (adjustable) Interpulse period T off Pulse frequency 48 V 60 V 4.7 k semiconductor switches, relays 10 2550 ms 2 ms 250 Hz 2 GMC-I Messtechnik GmbH

Outputs: The 2 analog outputs can be configured individually with the DIP switches. Analog Output (Current) (U1603) Output quantity direct current Output range Y2 Y +Y2 Upper range value Y2 20 ma Max. output voltage 30 V Max. output current 25 ma Load range 0 250 400 Analog Output (Voltage) (U1603) Output quantity direct voltage Output range Y2 Y +Y2 Upper range value Y2 10 V Max. output voltage 12.5 V Max. output current 40 ma Load range 2.5 k 5 k Alternating component 0.5 % Switching Output (Binary) (U1603) Switching element semiconductor relay, passive Number 4 Switching voltage 50 V Switching current ON OFF Volume resistance (AC/DC) 200 ma 10 A 5 Switching Output (Relay) (U1603) Switching element relay (changeover contact) Number 2 Switching voltage 250 V~, 30 V= Switching current 8 A resistive, 3 A inductive Operating cycles 10 5 Power Supply For External Switching Contacts Voltage U V 24 V = () Voltage tolerance ± 4% Current (short-circuit and 0.15 A idling proof) Alternating component 2% ( 100 khz) RS 232 Interface (PC / Printer) Number 1 (channel A and channel B) Connectors plug connector, sub miniature D9 plug Possible Connections channel A ECL, modem, terminal, radio-controlled clock Possible Connections channel B ECL, printer, radio-controlled clock Number of data bits 8 Transmission speed COM1/ COM2: 1200 115000 bit/s Parity even / no check Operating Mode FDX handshake Xon / Xoff or RTS / CTS ECS LAN Interface (For Linking Summators) (RS 485) Number 2 Connectors threaded plug connector (up to 255 users) Users per segment 16 (32 with loop resistance < 100 ) Operating mode multi-master, HDX or FDX Data protocol HDLC/SDLC (adapted to multi-master requirements) Topology (line and/or open ring) Transmission (hamming distance = 4) Status display Matching resistors LON Interface (for Connecting Meters) Number Connectors Operating mode Measurement Value Storage Time and Date Clock 1200 m open ring 100 m mix 15.6 375 kbps 2 LEDs can be activated 1 (FTT-10, twisted pair wires) threaded plug connector (up to 63 users per summator) LonTalk protocol (CSMA) Cable lengths wiring as desired 500 m bus, terminated 2700 m with special cable Transmission speed 78 kbps Status display 1 LED, LON active Bus termination can be activated 50/100 Storage mode continuous Memory depth with 1 channels: 87380 entries with 64 channels: 3971 entries Memory life span with backup battery 5 years (see also auxiliary power supply - backup battery) Resetting of meters to zero via PC Smallest unit of measure Admissible deviation 1 s 10 ppm = 5.3 min per year Functions Monitoring Status display with LED at front panel Status relay changeover contact Switching voltage 250 V ~, 30 V = Switching current 8 A resistive, 3 A inductive Operating cycles 10 5 GMC-I Messtechnik GmbH 3

Electromagnetie Compatibility Product standard EN 61326-1:1997/A1: 1998, industrial range Interference emission EN 55022:1998 class A Interference immunity EN 61000-4-2:1995 4 kv contact, 8 kv atmosphere Feature B EN 61000-4-3:1996+A1:1998 10 V/m Feature A EN 61000-4-4:1995 Feature B EN 61000-4-5:1995 mains cable: 1 kv sym., 2 kv asym. signal cable: 1 kv asymmetrical Feature A EN 61000-4-6:1996 3 V/m Feature B EN 61000-4-11:1994 Feature A Transmission Behaviour Accuracy class (with reference to the upper range value) Analog input/output 0.25% (U1603) Binry input/output 1 pulse (U1603) Cycle time analog meas. channels LON 1 channel LON 64 channels 2 ms 1 s 10 s Influencing Quantities and Influence Error (U1603) Influencing Quantity Nominal Range of Use Temperature 10 C... 22-24... 40 C 0 C... 22-24... 55 C Resistance to Climatic Conditions Allowable Influence Error as Percentage of Accuracy Class 50% 100% Output load load range 20% Auxiliary power nominal range of use 10% Relative humidity Temperature range Operation/function Storage, transport Elevation 75%, no condensation allowed 10 C +55 C 25 C +70 C up to 2000 m Auxiliary Power Supply Broad Range Input, AC - DC Nominal range of use, AC (45... 420 Hz) Nominal range of use, DC Power consumption Fuse Direct Voltage Input (optional) Nominal range of use, DC Power consumption Fuse Backup Battery Lithium cell (replaceable without tools and without data loss) Service life without auxiliary power at 20 C Capacity loss after 5 years with auxiliary power at 20 C Mechanical Housing material Dimensions Installation position Mounting 85 V... 264 V 100 V... 280 V 15 W (25 VA) 2 A slow-blow 20 V... 72 V 15 W 2 A slow-blow CR 2450 5 years 15% Protection housing: IP 40 terminals: IP 20 Weight 1.6 kg aluminum sheet 212 x 125 x 85 mm as desired top-hat rail per EN 50022 / 35 mm, or screw-mounted to plate 212 132 Electrical Safety Protection class Overvoltage category Nominal isulation voltage: Input Output: analog, binary, Uv Output: relay Interfaces AC Auxiliary Power DC Auxiliary Power Test voltages: Input - housing Input - output Auxiliary voltate - input Input - relay I per EN 61 010-1:1993/A2:1995 III 50 V 30 V 250 V 50 V 265 V 80 V 0.5 kv 0.5 kv 3.7 kv 3.7 kv Figure 1 8.5 4.3 All dimensions in mm Dimensions 106 125 134.5 Mounting tab for wall mount and for securing when mounted to top-hat rail 4 GMC-I Messtechnik GmbH

Electrical Connection Signal Cables Connectors Admissible cross section for connector cable Auxiliary Voltage Cables screw terminals Connectors screw terminals (L and N, or + and ) 2.5 mm 2 Admissible cross section for 2.5 mm 2 connector cable Protective conductor 6.3 mm cable lug Terminal Assignments U1602 Terminal Assignments U1603 Terminal Function ation 1 input E1 + 2 input E1 3 input E2 + 4 input E2 5 input E3 + 6 input E3 7 input E4 + 8 input E4 9 input E5 + 10 input E5 11 input E6 + 12 input E6 25 relay 1 Ö 26 relay 1 W 27 relay 1 Sch 28 relay 2 Ö 29 relay 2 W 30 relay 2 Sch 31 analog output A1 + 32 analog output A1 33 analog output A2 + 34 analog output A2 Terminal Function ation 35 binary output S1 (S0) + 36 binary output S1 (S0) 37 binary output S2 (S0) + 38 binary output S2 (S0) 39 binary output S3 (S0) + 40 binary output S3 (S0) 41 binary output S4 (S0) + 42 binary output S4 (S0) 43 power to ext. switching contacts + 24 V 44 power to ext. switching contacts 0 V 45 LAN Left EA + 46 LAN Left EA 47 LAN Left E + 48 LAN Left E 49 LAN Right EA + 50 LAN Right EA 51 LAN Right E + 52 LAN Right E 53 LON A 54 LON B 55 status relay Ö 56 status relay W 57 status relay Sch 58 auxiliary power supply L / + 59 60 auxiliary power supply N / GMC-I Messtechnik GmbH 5

Meter Input and Output Configuration (U1603) The analog inputs and outputs can be matched to the desired measuring range with the DIP switches. The respective upper limit value for any given range is configured with the help of the firmware. COM1 Pin Assignments for Sub Miniature D9 Plug COM2 Pin Assignments for Sub Miniature D9 Plug Pin Number Function 1 DCD 2 RXD 3 TXD 4 5 signal-ground 6 7 RTS 8 CTS 9 Pin Number Function 1 2 RXD 3 TXD 4 5 signal-ground 6 7 RTS 8 CTS 9 The cable with the designation Z5232000R0001 must be used for connecting a PC or a terminal. 6 GMC-I Messtechnik GmbH

Micro and Mini-Summator Configuration Communications and parameters configuration for the U1602 micro-summator and the U1603 mini-summator are accomplished with ECSwin software. Configuration of the U1602 micro-summator and the U1603 mini-summator is clearly structured. Differentiation is made amongst five different parameters groups (see figure 2, setup parameters). "General" parameters are used to configure the summator and are thus superordinate in nature, whereas the "channel-specific" parameters are directly related to the individual channels. The "RS 232" and "ECS LAN" parameter groups relate to the serial interface (RS 232) and the ECS LAN system bus (Energy Control System local area network). A six character password is used to protect individual parameters against unauthorized modification. Basic Configuration Setup Parameters Overview SUMMATOR CHANNEL DATA RS 232 ECS LAN LON 1 64... time / date summator name summator ID ime interval interval source --------- tariff source tariff unit tariff fixed point cost factor T1 cost factor T2 --------- password LCD contrast language date format --------- relay mode analog output test S0 level bootstrap and tests CHANNEL: Mode (OFF, meter, LON...) Channel name Long name E unit P unit channel visible on/off channel start/stop fixed point K factor meter constant U ratio I ratio P factor pulse duration edge LON CHANNEL: sub-channel LON activity neuron ID LON factor LON offset CHANNEL: Ana factor Ana offset Ana sign (+, -) I/O range U/M selection A unit Ana fixed point resolution Ana interval (A1, A2, command: ANAINT) COM1: mode baud rate parity handshake - COM2: mode baud rate parity handshake ECS LAN, left: mode terminated (yes/no) baud rate ------- ECS LAN, right: mode terminated (yes/no) baud rate new installation subnet/node address timing code poll delay bus terminator Figure 2 Setup Parameters GMC-I Messtechnik GmbH 7

Order Information The following applies to order designations: only one designation may be chosen for each given letter. if only zeros follow the capital letter in the designation, it need not be included in the order. Feature U1602 Micro-Summator U1603 Mini-Summator Auxiliary Power Operating Instructions and Commands Reference with bus termination, serial interface and LON interface with bus termination, serial interface and 6 universal inputs, LON interface AC + DC nominal range of use: 85 V... 264 V DC nominal range of use: 20 V... 72 V German English ation U1602 U1603 H1 H2 W1 W2 Order Example Either the feature or the designation can be included in the order. Feature (clear text) U1603 Summator with bus termination, serial interface and 6 universal inputs, LON interface ation U1603 Auxiliary Power DC nominal range of use: 20 V... 72 V H2 Operating Instructions and English W2 Commands Reference Accessories Feature ation Connector Cable for PC or terminal GTZ5232000R0001 Prepared in Germany Subject to change without notice A pdf version is available on the internet GMC-I Messtechnik GmbH Südwestpark 15 90449 Nürnberg Germany Phone +49 911 8602-111 Fax +49 911 8602-777 E-Mail info@gossenmetrawatt.com www.gossenmetrawatt.com