Standard: 2 x 500 ml and 2 x 250 ml (safety) bottles with shut-off valve and 2 µm in-line filter. Built-in 4 channel He degasser.

Similar documents
Sepacore X10 / X50 system Technical data sheet

ANALYTICAL SYSTEMS. L3320 Autosampler with excellent accuracy and linearity. System configuration examples

Agilent 1260 Infinity Diode Array Detector

Spark Holland introduces

Agilent Max-Light Cartridge Cell Information for G4212A/B DAD and G7117A/B DAD

Cecil Dissolution 4/9/06 4:51 pm Page 1 DISSOLUTION SYSTEMS

Spark Holland introduces

Technical Overview. Introduction

Waters 2707 Autosampler ICS v1.20 Installer

Release Note for Agilent LC and CE drivers Revision A.02.14

Beta (Gamma) Radioactivity. Flow Monitor. Analyser

eprep Sample Preparation Workstation

3 Starting the chiral HPLC and logging into LC Real Time Analysis.

REACH FOR MORE CHOICES IN LC ANALYSIS. FLEXAR LC Systems HPLC and UHPLC Flexar LC / Flexar FX-20

Dissolution Automation: Off line Hybrid Systems

Varian 356-LC Control Software

Resolution 1 F (1 C) single point; degrees C or Calibration single or dual point Calibration F

Flexar FX-20 LC Pump: Ultimate Performance and Flexibility for UHPLC and HPLC

Manual HPLC-4 Alliance-UV

Agilent 1100 HPLC ChemStation 1) Turn on all the modules for HPLC system (CapPump G1376A, DAD G1315B) and allow for system to initialize.

Flexar FX-20 LC Pump: Ultimate Performance and Flexibility for UHPLC and HPLC

SepacoreControl Software data sheet

Waters 600E Multisolvent Delivery System Quick Start Guide

HITACHI LACHROM ELITE

Introduction to the HPLC ChemStation and Acquisition

Operating Manual. High Performance Liquid Chromatograph. Scientific Equipment Center, Prince Of Songkla University

Agilent 1200 Infinity Series High Dynamic Range Diode Array Detector Solution

Integral Process Analytical Liquid Chromatography Systems

OEM applications. Our engineers welcome your ideas and are pleased to help realize your projects. IDEX Complete Fluidic Solutions

Agilent Splitter Kits

Mitos P-Pump. product datasheet

Quick Setup Instructions for the Knauer HPLC-System. Quick Setup Instructions for the Knauer HPLC-System For windows XP (using CHANCE vers. 2.

PerkinElmer Series 200 HPLC: Operating Procedure

Accessories for

Upchurch Scientific Nano Flow Sensor User s Guide

Optimizing System Dispersion on the Agilent 1290 Infinity II LC

Product Catalog. EasySampler EasySampler Unattended, Representative Sampling

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Luminex Prima

Dissolution Automation: Off line Systems

Equipment Overview: Safety:

Release Note for Agilent LC and CE Drivers Revision A.02.16

Educational Microfluidic Starter Kit

N.1 ION CHROMATOGRAPHY/HPLC MODULAR SYSTEM FOR ANIONS, CATIONS, TRANSITION METALS, PESTICIDES, PAH

Spraybase Technical Specifications Sheet

OpenLAB. CDS EZChrom Edition KNAUER Instrument Control SOFTWARE

Agilent 1200 Infinity II Series Refractive Index Detector

SHIMADZU LC-10/20 SYSTEM

NIR-Online Multipoint System Technical data sheet

AZURA instruments & components for (U)HPLC, Prep LC, FPLC and osmometry

Brownlee SPP. HPLC and UHPLC Column Solutions with Superficially Porous Particle Technology

Hand-Held Pressure Indicator

Hand-Held Pressure Indicator Model CPH6200-S1 Model CPH6200-S2 (2-channel version)

ANALYTICAL NovoGROM COLUMNS 3.0, 4.0, and 4.6 mm i.d.

AGILENT 1100/1200. Clarity Control Module. Code/Rev.: M060/70D Date: 10/5/2017

9 Maintenance. Agilent Technologies. This chapter describes the maintenance of the module. InfinityLab LC Series Diode Array Detectors User Manual

MCS 100 E. Compact IR Photometer for Stack Gas Monitoring

UniPoint System Software User s Guide

Customers should provide all necessary operating supplies upon request of the engineer.

Thermo Scientific Dionex Aquion Ion Chromatography System

4 plate fully automated ELISA analyzer Reagent system. Open (Human tests predefined) Throughput (max.) Up to 7 plates / run Reaction / reading system

Intrinsically safe Hand-Held Pressure Indicator (ATEX-version) Model CPH62I0

Industrial pressure controller Model CPC4000

Bio Compatibility Kit

Manual for the MicroSIA Instrument

SPM Zero dead volume dilutor DATASHEET

More Precision. thermoimager TIM // Compact thermal imaging cameras

powered by TAS Technology

HIAC Liquid Particle Counting System. Easily configurable for maximum flexibility

Minisart Syringe Filters Removal of Particles and Microorganisms from Liquids and Gases

Release Note for Agilent LC and CE Drivers Revision A.02.17

UPGRADE PROGRAM. V250 Series Pumps vs V301 Series Pumps. Technical Memo

Particle size range (0.8 microns 1000 microns)

Guidebook for Installation and Familiarization. HP 1100 Series Combinatorial Chemistry Analysis System

Agilent 1290 Infinity with ISET

Products for Health Care

ACQUITY UPLC Systems with 2D Technology Capabilities Guide

Mitos Duo XS-Pump Part No

Model KBW 720 Growth chambers with light

DC - Devices and Controller

HIAC Liquid Particle Counting System. Easily configurable for maximum flexibility

COBRIX 2 On-line Beverage Analyzer. Anton Paar

C190-E092A Prominence Gel Permeation Chromatography System Shimadzu High Performance Liquid Chromatograph

Accessories for

Technical Specifications

Agilent SD-1 Purification Solution

Using the Chromeleon Summit 2 Tandem Operation Wizard

Near- Infrared Analyzer Beat Sensor GP

PinAAcle 900 AA Spectrometers

Microplate Readers INSTRUMENTS. Description Catalog # Description DAR800 SF2100 SF4700

Agilent Instrument Control Framework A for Agilent LC/CE and GC Instruments in Non-Agilent Chromatography Data Systems Release Notes

NIR-Online Technical data sheet

Soprane II Documentation

1 plate fully automated ELISA analyzer Reagent system. Open (Human tests predefined) Throughput (Max.) 1 plate /run Barcode reader

Aqueous GPC Instructions - Detailed

MIST Version 2.0 USER S GUIDE. Preliminary Version. INTRODUCTION...2 General Description...2 Models Available...2

Flash Chromatography. Sorbtech Purity Flash Cartridges. EZ Flash Cartridges. EZ Flash Systems. Flash Chrom.

phoenix Upgrade Packages for SLM Model 4800/48000/8000/8100 Spectrofluorometers

DMT PERFORMING UNDER PRESSURE DMT. All-Media Pressure Scanner Features. Applications. Description 1/8

Hand-held thermometer Model CTH6200

DigitalFlow GC868 Panametrics Clamp-On Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

Transcription:

The UltiMate Solvent Organizer 3.9 Specifications 3.9.1 Solvent Organizer Reservoirs Solvent Degassing Standard: 2 x 500 ml and 2 x 250 ml (safety) bottles with shut-off valve and 2 µm in-line filter. Built-in 4 channel He degasser. Full traceability of solvents used (composition, purity, supplier, etc.) in hardware settings of UltiChrom software. 3.9.2 Injector Valve Injection Loop Fill Port for Needle Manual, low dispersion 6 port valve with position feedback for automated injection mark (start data acquisition). Standard: 5 µl (optional: 1 µl). 2 x 22 gauge. 3.9.3 Column Compartment Dimensions Connection 70 mm (3 in) x 60 mm (2.5 in) x 400 mm (16 in), for a microcolumn with length up to 300 mm (12 in). Preinstalled fitting, dead volume free. Complete column specification and identification during system set-up (UltiChrom software). 3.9.4 Operating Software UltiChrom Recommended Computer Configuration Full control of UltiMate instrument settings and run sequences, including data acquisition (maximum 4 channels), data evaluation and presentation. Runs under Windows 3.1, 95, 98 and NT based operating systems. IBM compatible 166 MHz Pentium computer, 64 Mb RAM, 500 Mb hard drive, Super VGA display (1024 x 768 resolution), CD-ROM drive, 3 free com ports. Full Compliance, including year 2000 compliance. 3-38 D970R2 User s Manual UltiMate

The UltiMate Solvent Organizer 3.9.5 General Power 115/230 V, 47-63 Hz, 250 VA (factory set) Requirements Fuse 230 V Version: Slow-Blow, 2 A 115 V Version: Slow-Blow, 5 A Dimensions 250 mm (10 in) x 400 mm (16 in) x 530 mm (21 in). Weight 22 kg (48 lb). He Supply 1-2 bar (15-30 PSI) Wetted Parts PTFE, graphite fiber filled PTFE, PEEK, glass, sapphire, ceramic, fused silica, stainless steel Types 316 and V4A. ph Range 2-10. Production ISO 9002 certified manufacturing. Quality CE certified (LVD and EMC). Operating 10-40 o C, 20-80% relative humidity. Temperature User s Manual UltiMate D970R2 3-39

The UltiMate MICROPUMP 4.10 Specifications 4.10.1 Flow Characteristics Pump Type Reciprocating double piston pump with electronic residual pulsation suppression Flow Rate 0-500 µl/min Range Flow Rate < 0.5 % Accuracy Flow Rate Predefined by Calibrator in Solvent Organizer (when used in Selection conjunction with UltiMate) Gradient Low pressure quaternary mixing with high speed micro Formation proportioning valves Gradient <0.5 % RSD (typically < 0.02 % RSD) Accuracy (when used in conjunction with UltiMate) Delay Volume Calibrator Dependent Micro HPLC ~ 120 µl Capillary HPLC ~ 12 µl Nano HPLC ~ 0.6 µl (when used in conjunction with UltiMate) Rapid Purge Yes Valve Pressure Range 0-40 MPa Tracking of instrument usage, total pump cycles, total volume electronic records of installation, maintenance, error codes 4.10.2 Instrument Control User Interface Instrument Control Keypad, 16 Keys, Liquid Crystal Display 2 x 24 characters 2 x RS-232C terminals for remote control operation via UltiMate Software Tracking of instrument usage, total pump cycles, total volume, electronic records of installation, maintenance, error codes 4.10.3 Inputs/Outputs Solvent Generation Events Recorder Output 4 Low Pressure Gradient Proportioning Valves 4 TTL (max 10 ma)* 2 Open Collector (max 40 ma)* 2 Relay (normally open) START-, ERROR IN: Optocoupler, max 10 ma* START-, ERROR OUT: Open Collector, max 40 ma* * Events controlled by UltiChrom Software 2.5 mv/mpa (1 V = 40 MPa) 4-30 D970R2 User s Manual UltiMate

The UltiMate MICROPUMP 4.10.4 General Power Requirements Fuse Dimensions Weight Production Quality Operating Temperature 90-260 V, 47-63 Hz, 100 VA Maximum 2 Slow-Blow, 2A 160 mm (6.4 in) x 340 mm (13.4 in) x 185 mm (7.3 in). 5.5 kg (12 lb.). ISO 9002 certified manufacturing. CE certified (LVD and EMC). 10-40 o C, 20-80% relative humidity. User s Manual UltiMate D970R2 4-31

The UltiMate UV Detector 5.10 Specifications 5.10.1 Detection Characteristics Detection Type Rapid scanning monochromator Noise 1 x 10-5 AU (254 nm, 1.0 sec) Drift 1.5 x 10-4 AU/h Time Constants 0.1/0.2/1/2/5/10 sec Wavelength Range 190-740 nm, up to four wavelengths can be monitored simultaneously Sources D2, Tungsten Wavelength +/- 1 nm Accuracy Scans per run Number is limited only by speed of data transfer (time programmed or manually launched) Scan Ranges 190-380, 381-740, 190-740 nm Scan Autozero Full wavelength range Bandwidth < 7 nm Scan Speed ~ 100 nm/sec 5.10.2 Instrument Control User Interface Instrument Control and Data Evaluation Data Rate Keypad, 16 Keys, Liquid Crystal Display 2 x 24 characters 2 x RS-232C terminals for remote control operation via UltiChrom Software 1-10 Hz Continuous tracking of lamp burn time, instrument usage, electronic records of installation, maintenance, error codes 5.10.3 Flow Cells, 10 mm UZ-View Application Micro LC Capillary LC Nano LC Type UZ-M10 UZ-C10 UZ-N10 P/N 160011 160013 160015 Flow rate range 10-100 µl/min 1-10 µl/min 0.1-1 µl/min Illuminated volume 180 nl 45 nl 3 nl Capillary ID 150 µm 75 µm 20 µm Path length 10 mm Noise < 0.05 mau (a) Max. Pressure 400 bar (6000 psi) (a) @245 nm, Acetonitrile/water (70/30), TC 2 s 5-30 D970R2 User s Manual UltiMate

The UltiMate UV Detector 5.10.4 Flow Cells, 30 mm UZ-View Application Micro LC Capillary LC Nano LC Type UZ-M30 UZ-C30 UZ-N30 P/N 160012 160014 160016 Flow rate range 10-100 µl/min 1-10 µl/min 0.1-1 µl/min Illuminated volume 540 nl 135 nl 10 nl Capillary ID 150 µm 75 µm 20 µm Path length 30 mm Noise < 0.05 mau (a) Max. Pressure 400 bar (6000 psi) (a) @245 nm, Acetonitrile/water (70/30), TC 2 s 5.10.5 Inputs/Outputs Digital Output Analog Input Analog Output 2 RS-232 2 EVENT: (Open Collector, Relay) START-, ERROR IN: Optocoupler START-, ERROR OUT: Open Collector 1 V (1V/100 nm) 2 ±0.1 V/ ±1 V / ±10 V (for recorder or integrator) 5.10.6 General Power Requirements Fuse Dimensions Weight Production Quality Operating Temperature 90-260 V, 47-63 Hz, 100 VA Maximum 2 Slow-Blow, 2A 160 mm (6.4 in) x 340 mm (13.4 in) x 185 mm (7.3 in). 5.5 kg (12 lb.). ISO 9002 certified manufacturing. CE certified (LVD and EMC). 10-40 o C, 20-80% relative humidity. User s Manual UltiMate D970R2 5-31