TeamConnect Ceiling Ceiling microphone conference system

Similar documents
TeamConnect TeamConnect System - The perfect audio solution for meetings

TeamConnect SL TeamConnect CU1, Central Unit, SL TeamConnect CB1, Combox

DATA SHEET DEVIO DEVIO CR-1 CONFERENCE ROOM DEVICE

DATA SHEET DEVIO SCR-20 CONFERENCING HUB

Orbis MU 41. Digital Flush Mount Delegate Microphone Unit Order #

TeamConnect. Meeting and audio conference solution. Instruction Manual

Orbis MU 21. Digital Delegate Microphone Unit with Loudspeaker Order #

SL Interpreter Compact

Professional Audio Conferencing Products - CONVERGE Pro 2 Series

Overview. Features. Technical Data Sheet 1 / 6. Mixing Console AG03

LSP 500 PRO. Wireless Integrated Professional Audio System FEATURES ARCHITECT S SPECIFICATION

CS-120. Conferencing and Discussion / Interpretation System. Digital Conference System. conference system. CS-120 Series

Overview. Features. Technical Data Sheet 1 / 6. Mixing Console AG06

LPT-C2 & LPT-C6 ListenPoint Standard & Advanced Control Unit (CU)

DATA SHEET DEVIO CR-1 CONFERENCING HUB

Overview. Features. Technical Data Sheet 1 / 6. Mixing Console MG10. MG10 is a versatile mixer suitable for a wide range of users and applications.

Overview. Features. Technical Data Sheet 1 / 5. Signal Processor MRX7-D

DATA SHEET TESIRA TCM-1 AVB BEAMTRACKING CEILING MICROPHONE

User Manual. Please read this manual carefully before using the Phoenix Octopus

MG12XU Overview Features Technical Data Sheet

Instructions for use. MKH 8020 Stereo

PS 630 SIX CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

PS 430 FOUR CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

HCS-5300MA/ 80 Digital Infrared Wireless Conference Main Unit

Quinta MU 31 FEATURES. Digital Wireless Delegate Microphone Unit Order #

DATA SHEET TESIRAFORTÉ DAN AI

CHAT 150 CHATAttach 150 Group Speakerphone. Quick Start Guide

SpeechLine. IS microphone series. Microphone solutions for your conference meeting room presentation. Instruction manual

Spider MT503 SMART USER MANUAL. Page 1

ASP-MG2240. Amplified Sound Masking System

HORECA140BK. Plug & Play Audio Set ECLER TECHNICAL DATA SHEET AUDIO SETS

AMP Watt Audio Amplifier with RS-232 and IR Control. User s Manual CUSTOMER SUPPORT INFORMATION

AMP20. User Manual.

Spider MT503 SMART USER MANUAL. Page 1

PJP-50USB. Conference Microphone Speaker. User s Manual MIC MUTE VOL 3 CLEAR STANDBY ENTER MENU

SMART Audio classroom amplification systems Model CAS-340

PS 230 DUAL CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

HCS-48U7C Chairman Unit with Voting and Channel Selection

HD 46 HME 46. Instructions for use

QM-AE1. QuickMedia Audio Extractor

HPA4202 1/5. 2-Channel High Power Multi-Impedance Amplifier. General Description. Features. Applications. AtlasIED.com. HPA4202 Front.

Stereo / Mono. Audio Power Amplifier W. Introduction. Applications

Meeting Room Solutions

CS-1 Active Full Range Integrated Commercial Audiovisual System

ControlSpace ESP-1240 TECHNICAL DATA SHEET. engineered sound processor. Key Features. Product Overview. Product Information.

System Interface Unit SIU-100/100T

Esfera SPM Instruction manual

CU 4005 CDS 4000 Central Control Unit for 50 Conference Units

HMEC Instructions for use

SL Headmic 1. Instruction manual

PJP-25UR Conference Microphone Speaker

PRELIMINARY DATA SHEET AM 1 AUTOMIXER SHIPS APRIL 2010

xin 4, xio 4x4 and xout 4

INT-HD52 Quick Install Guide

CLOUD CX261 Single Zone Mixer

ControlSpace ESP-1240 TECHNICAL DATA SHEET. engineered sound processor. Key Features. Product Overview. Product Information.

IP-ZCM. PoE+ IP to Analog Gateway (Zone Controller)

Orbis CU. Digital Control Unit Order # Optional CA-OR kit for 19" rack mounting front view

TECHNICAL DATA SHEET DS 16S/DS 16SE. FreeSpace. Loudspeakers. Product Overview. Key Features. Product Information. Applications

PJP-25UR Conference Microphone Speaker

PS 150 SINGLE CHANNEL TELEPHONE INTERFACE. USER MANUAL August 2016

USB VGA KVM Console Extender w/ Serial & Audio Over Cat5 UTP ft

IP-3000 Series. IP Network Public Address System. Monitoring and setting can be done easily by logging-in to control GUI via browser.

MKE 600. Perfect Sound.

* Answer/end call requires EHS cable for desk phone

M-1264 M-1212E STEREO MIXERS. TOA Corporation OPERATING INSTRUCTIONS. TOA 1000 series CAUTION

CHAT 50 Personal Speakerphone. Quick Start Guide

Classis RM 30 Classis RM 31

HCS-5300MA/80 Digital Infrared Wireless Conference Main Unit

FreeSpace Amplifiers. Premium commercial amplifiers designed to enhance audio installations using Bose FreeSpace loudspeakers.

The 5.8mm diameter ROM-2235L-HD-R is designed for extreme fidelity in a compact housing with true 20 Hz to 20 khz performance.

AEROBICS AND VOCAL HEADSET MICROPHONE PM4 PHANTOM POWER ADAPTOR OWNERS MANUAL QE AEROBICS MIC QV VOCAL MIC. PM4 Phantom power adaptor

Di2 Mk3 Active Direct Inject Box

MPS10 - MPS50. Modular Paging and Emergency Microphones

M 930 M 940 M 950 STUDIO CONDENSER MICROPHONES. Polar pattern: Cardioid, super-cardioid, wide-cardioid

BASIC PA AMPLIFIER A-1031 A-1061 A-1121 OPERATING INSTRUCTIONS TABLE OF CONTENTS

MPS01. Paging and Emergency Microphone

Digital Mixing System D-2000 Series

ASK-4 #101-DV AUDIO MONITORING SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS

Full workday of talk time 8 hours wideband and 12 hours narrowband Two years warranty for peace of mind

HCS-5300MA/20 Digital Infrared Wireless Conference Main Unit

CU 6005 DCS 6000 Medium Power Central Control Unit

MCS 50. Discussion Control Unit. 1 of 7

Versatile configuration options

ControlSpace ESP-00 Series II TECHNICAL DATA SHEET. engineered sound processor. Key Features. Product Overview. Product Information.

INFORMATION AMPLIFIER TA-102 OPERATING INSTRUCTIONS TABLE OF CONTENTS

TECHNICAL DATA SHEET. FreeSpace DS 100SE. Loudspeaker. Product Overview. Key Features. Product Information. Applications

User focus DW Pro 2 is designed to maximize productivity and flexibility in busy offices with its

TOA Net Price List PROFESSIONAL USER

Features. General Specifications. Surface Mount Speaker VXS5/VXS5W. Sophisticated sound and design for matching any application. Technical Data Sheet

HCS-5300MA/20 Digital Infrared Wireless Conference Main Unit

D-901 ALL-IN-ONE MODULAR DIGITAL MIXER

ZCM-V2+T. PoE+ IP to Analog Gateway (Zone Controller) Used In the ZC1PRO+T and ZC2PRO+T

HMEC 26. Instruction manual

AMX-9-DSP4-ACD YEARS OF EXPERTISE. DIGITAL AUTOMATIC PRE-AMPLIFIER

IDA8C. Networkable PAVA system Controller Unit. IDA8 System

VS-88UT All in One Presentation System with 8x8 4K60 4:2:0 HDMI/HDBaseT 2.0 Matrix Switching, Master Room Controller, PoE & Power Amplifier

HDMI and USB over IP Distribution Kit p

Multimedia digital audio mixer

User s Manual. Cardioid Microphones Type 4011 Type 4012

Transcription:

1/9 FEATURES Allows the person speaking to move around freely anywhere in the room during conferences and presentations Integrative Freedom: Virtually invisible integration thanks to unobtrusive design and inconspicuous installation variants Connectivity & Compatibility: The conferencing system for Unified Communications following the BYOD (Bring- Your-Own-Device) philosophy Excellently microphone directivity thanks to state-ofthe-art beam-forming technology, realized in proven Sennheiser quality Very low configuration and maintenance effort The new conference system blends into any conference room infrastructure. Thanks to three optional installation variations, the ceiling microphone can be installed in or on any ceiling while the central unit is hidden away in the cabinet and the loudspeakers are mounted freely in the room. Because of this, the tables remain free from cables and there are no requirements of a fixed table positioning. The ceiling microphone covers up to 60 m². For larger groups the system can be easily expanded with additional ceiling mics. After initial installation, the system requires little to no additional maintenance. PRODUCT VARIANTS EU Art. no. 506975 UK Art. no. 506976 US Art. no. 506977 DELIVERY INCLUDES SL Ceiling Mic ceiling microphone TeamConnect System (EU, UK or US) with Central Unit and Combox 2x SL Loudspeaker 52 A W active conference loudspeaker Power supply unit with EU, UK or US power supply cord Cable set (audio, power and control cable, 10 m each, plenum-rated) Ceiling suspension kit US 2 ft adaptor set Mounting instructions ACCESSORIES SL CM FB Ceiling fixation bracket Art. no. 506846

2/9 SPECIFICATIONS SL Ceiling Mic Dimensions (L x W x H) Weight AUDIO I and AUDIO II sockets POWER socket CONTROL socket Supply voltage Power consumption 590 x 590 x 43 mm (23.2" x 23.2" x 1.7") 6 kg (13.2 lbs) 2 x 3-pin terminals (fits Phoenix Contact MCVW 1.5-3-ST-3.81) 4-pin terminal (fits Phoenix Contact MCVW 1.5-3-ST-3.81) 6-pin terminal (fits Phoenix Contact MCVW 1.5-3-ST-3.81) 20 28 V DC 20 W Temperature Operation: 0 40 C (32 104 F) Storage: -10 60 C (14 140 F) Relative humidity 20 95 %, non-condensing Microphone type pre-polarized condenser microphone Sensitivity -1 dbv/pa (930 mv/pa) Equivalent noise level 20 db(a) Number of KE 10-237 29 microphone capsules Pick-up pattern Beam pattern Max. sound pressure 119 db SPL level Dynamic range 99 db(a) SL TeamConnect CU1 Dimensions (W x H x D) Weight MIC / LINE inputs 1-8 Impedance Maximum level Phantom power LINE inputs 1-2 Impedance Maximum level LINE OUT outputs 1-8 Impedance Nominal level Maximum level SL TeamConnect CB1 Dimensions (W x H x D) Weight Frequency response Noise Dynamic range SL Loudspeaker 52 A W Dimensions (L x W x H) Weight Frequency response ± 3 db Max. SPL at 1 m (150-5,000) Hz THD at 90 db SPL at 1 m > 200 Hz Input impedance Power consumption (standby) 432 x 191 x 51 mm (17" x 7.5" x 2") 2.25 kg (4.5 lbs.) 10 kω balanced -65 dbu to +17 dbu 24 V DC at 10 ma 10 kω balanced 17 dbu 50 Ω 0 dbu 17 dbu 119 x 143 x 44 mm (4.7" x 5.6" x 1.7") 1.51 lbs. (0.75 kg) 40 to 3,300 Hz THD < 0.04 % re-max level with 0 db gain at 1 khz > 84 db (non A-weighted) 240 x 140 x 161 mm (9.5" x 5.5" x 6.3") 3.1 kg (6.8 lbs) 53-30,000 Hz 97 db SPL < 1 % balanced > 10 kω unbalanced > 10 kω 230 V AC; 0.47 W / 110 V AC; 0.34 W Power consumption (idle) 230 V AC; 4.75 W / 110 V AC; 4.53 W Power consumption (max) 230 V AC; 95 W / 110 V AC; 91 W Mounting points 2 x M6 on rear panel with depth 10mm

3/9 ARCHITECT S SPECIFICATION A complete professional ceiling microphone conference system for fixed installation in medium to large conference rooms where table microphones are not desirable or possible, comprised of a central unit, a combox, a ceiling microphone and two active loudspeakers. The ceiling microphone shall fit within the space of a standard 600 mm (2 ft.) ceiling panel and shall be mountable either onto or flush with the ceiling itself. The ceiling microphone shall consist of 29 Sennheiser KE 10-237 pre-polarized condenser microphone capsules and shall use beamforming technology that automatically focuses on whoever is speaking in the room. The microphone shall be supplied complete with a ceiling suspension kit for ceiling installation, an external power supply unit with 3 country-specific mains cables, a power cable for connection to the external power supply unit, an audio cable for connection to the central unit, and a control cable for connection to the SL TeamConnect CB1. The microphone shall have a 4-pin terminal socket for connecting the power cable, two 3-pin terminal sockets for connecting the audio cable and a 6-pin terminal socket for connecting the control cable. In addition, the microphone shall feature the following sockets, buttons and LEDs located behind a service hatch: an RJ- 45 network socket for connecting a computer for configuration purposes, a SET LED that flashes when the microphone is ready for operation, an IP button for switching between a static IP (192.168.1.10) and the microphone s integrated DHCP server, an IP LED that lights up for static IP and flashes for DHCP IP addressing, a Reset button for performing a restart of the microphone, and a Reset LED that lights up when mains voltage is present. The microphone sensitivity shall be -1 dbv/pa (930 mv/pa). The maximum sound pressure level shall be 119 db SPL, equivalent noise level shall be 20 db(a). The dynamic range shall be 99 db(a). Operating voltage shall range from 20 to 28 V DC. The power consumption shall be 20 W. The microphone shall be compatible with the SL Ceiling Mic Configuration Manager software for easy configuration. The microphone shall be the Sennheiser SL Ceiling Mic. The central unit shall be an automatic mixer for professional quality audio in multiple microphone web and teleconferencing applications. It shall provide advanced mixing capabilities and configuration options. All devices used in the system shall be connected, directly or indirectly, to the central unit. The central unit shall be equipped with a TELCO telephone interface. An Ethernet port shall be provided for network connections. The central unit shall feature an RS-232 control port for connecting a third party media control system (Creston, AMX, etc.). The central unit shall have a USB 2.0 port for connecting a PC for configuration purposes and shall also be configurable via the RS-232 port or the network (Ethernet port). The required Configuration Manager PC software for configuring the central unit and all other components shall be supplied. The central unit shall feature eight mic/line inputs (each with 24V switchable phantom power), two additional line inputs and eight audio outputs for connecting e.g. active loudspeakers. The central unit shall support mono and stereo acoustic echo cancellation, i.e. one or two out of the eight outputs shall be selectable as the acoustic echo cancellation reference. The connection between the central unit and the combox shall be made by means of a standard CAT5 cable. The central unit shall be the Sennheiser SL TeamConnect CU1. The combox shall be plug and play (no drivers required) and shall be the system s audio interface, allowing the system to be used as an audio extension. The combox shall be used to process computer audio as well as headset or enterprise telephone audio in the system. The USB 2.0 port of the combox shall allow the connection of a PC. Via the combox, the system shall be capable of playing back all audio from the PC (e.g. web conferences, any audio and video content) as well as picking up and processing the audio in the meeting room and feeding it back to the PC. In addition, any device with a 4-pin 3.5 mm jack socket (e.g. a mobile phone or tablet PC) shall be connectable to the combox s headset socket via a 4-pin special cable, thus allowing audio from the mobile device to be processed in the system. The combox shall be the Sennheiser SL TeamConnect CB1. The loudspeaker shall be active and optimized for speech intelligibility. Its high, medium and low frequency levels shall be adjustable in order to obtain optimum sound quality depending on the mounting position of the speaker and the room characteristics. The loudspeaker shall have 2 power modes: on and auto standby. The loudspeaker s high pass filter shall be adjustable to 50 Hz, 70 Hz or 100 Hz. The input sensitivity shall be selectable between -6 dbu, 0 dbu or +10 dbu. The loudspeaker shall come complete with a wall mounting kit and, when wall mounted with the supplied spacers, shall be pivotable by 180 and tiltable. Up to eight loudspeakers shall be connectable to the central unit. The loudspeaker shall be the Sennheiser SL Loudspeaker 52 A W. Dimensions shall be as follows: central unit: 432 x 191 x 51 mm (17 x 7.5 x 2 ); combox: 119 x 143 x 44 mm (4.7 x 5.6 x 1.7 ); loudspeaker: 240 x 140 x 161 mm (9.45 x 5.51 x 6.34 ); ceiling microphone: 590 x 590 x 43 mm (23.2 x 23.2 x 1.7 ). Approximate weights shall be as follows: central unit: 2.25 kg (4.5 lbs.); combox: 0.75 kg (1.51 lbs.); loudspeaker: 3.1 kg (6.83 lbs.); ceiling microphone: 6 kg (13.2 lbs). The ceiling microphone conference system shall be the Sennheiser.

4/9 SL Ceiling Mic 590 mm 23.2" 590 mm 23.2" 43 mm 1.7" PIN ALLOCATION 1 2 3 4 5 6 1 2 3 4 1 2 3 1 2 3 CONTROL POWER AUDIO OUT 1 +24 V 1 +24 V 1 Audio + 2 COM 2 +24 V 2 Audio - 3 On status 3 Ground 3 Ground 4 Hook status 4 Ground 5 Mute status 6 Ground

5/9 SL CM FB 500 ±0.2 A 420 ±0.2 t=1,5 6.6 500 ±0.2 420 ±0.2 B B 430 A 2 ±0.1 180 ±0.1 ( 10 ±0.1 )

6/9 US 2ft adaptor set 580 t=1,2 262 ±0.15 262 ±0.15 A-A 1 1 A 131 131 16 ( 45.7 ) 42.5 ±0.2 R 5 R 5 5.5 16 R 5 R 5 16 16 16 5.5 15 ( 25 ) 3.4 1 5.5 23.8 1 11.3 90 2 12 ( 31.5 ) R 3 45 3.4 45 90 3.4 alle Flächen: Neben-Sichtfläche N-S2 nach SNP 10, pulverbeschichtet, Verkehrsweiß, glatt matt, nach RAL 9016 all surfaces: minor viewing areas N-S2 as per SNP 10 powder-coated, traffic white, flat matt, as per RAL 9016 A 90 ( 1.2 )

7/9 SL TeamConnect CU1

8/9 SL TeamConnect CB1

9/9 SL Loudspeaker 52 A W