LoadPlanner CAD@ 2018 Version 3.36 Dated 23-02-2018 Functions updated Load align Handling and creating wind towers Creating tween deck panels Creating of Plan Model Copy as loaded, varies block stowage, and grouped units New Right click a top viewed unit, edit individual unit text Explorer. Ships library, data list of all stanchion files Version 3.35 Dated 26-01-2018 (not released) Various corrections to USB Installations Version 3.34 Dated 05-01-2018 Correction to Units text and color setting In v3.33 the converting of old ship files (*.Shp) disabled, function enabled and updated Other corrections Version 3.33 Dated 20-12-2017 This update only contains error corrections Installations There have been some issues installing updates, all problems occur due to Microsoft Update running For IT departments doing Puss forward installations no problems, but if you not a hard-core IT administrator, restart your Pc, do not Run any applications then install the program If you fail to do the installations correct, you have to uninstall then reinstall, Repair installations only work if installed correct first time Activations Deactivations and Reactivations All updated according to Microsoft recommendations, also a system Diagnostic tool added Explore > Help > Diagnostic, create a log file enable LoadPlanner.DK to supply support Diagnostic only handling licenses and installations information s, not errors in normally use The log only needed if you are ask to send it Safety issue NOTE: for any communications via the internet to the server, you must log on window as administrator or run the program as administrator In daily use the program does not require administrator privileges However, if you are linking paths to password protected network, it will not be shown in LoadPlanner Explorer
Open the drive in Microsoft explorer first, then open LoadPlanner Generic Errors handling New GenericErrorEventHandler Error handling inside the matrix Typical error as System Out of Memory User will be guided to fix the problem NOTE: If you are getting the error System Out of Memory you strongly recommended save your work, close LoadPlanner CAD and free memory before continuing If you just continue, you file may not be recoverable Typical reasons for getting the System Out of Memory error Incorrect stanchion file, all drawings object converted to polyhatch (AutoCAD users!!) User having a lot of heavy drawings open in UserCAD Adding more than 4000 individual units to Quay area (Filter your Load List before adding units) Using PDF converted to CAD without cleaning the drawing fires (See help file Working with converted PDF file) (a bit of commons senses you so you don t get this error) What color of the curtains in the accommodations or how many screws and size on the brake of the windlass, is so never mind in a cargo planning tools LoadPlanner CAD is not a ship art design, only a cargo planning tool, if you need to do art use the UserCAD Shifting from Cargo Model to Plan Model Also recover System Out of Memory errors The functions have been rewritten, to speed up flowed, but also handling any incorrect base point and blocks Container Grid Creating new or modifying container grid has been rewritten Much more user friendly File do not longer require reloading Version 3.32 Dated 08-11-2017 Program start up Errors in missing registrations of needed drivers, or incorrect user profile, earlier resulted in new Lock in requirement A startup function added, checking for any errors in the startup prosses, and guide user to fix the problem A Reactivations of license added. Error corrections Unit Properties, New Pipe Unit Properties, selecting POL, POD and Ref on list Load List, Units defined block, missing reference to main unit (none selected) Ships Eqp. User defined twd setting, ordering corrected Project file Grid and Bulk Open file with "Unonymus" layers, unonymus layers will be deleted Functions updated Container handling, Cargo Model, Aft and top viewed loading, see the manual Layout, 20Ft Bay plan
Layout, 40Ft Bay plan Loaded List, Export weight list for use in external stability programs AutoCAD 2018 format added, Require updated file converter New Function Units AutoCAD look, set units transparent to 100% and pin color will follow selected POL, POD or REF color To use unit fill and pin color same time, check mark Include Units pin color, in color selection For existent files, re select text selections before pin color updated Version 3.31 Dated 10-10-2017 Container Grid Setup container grid, adjusting TCG for transverse tires on deck fixed New function, Pick LCG for each bay in UserCAD, see the manual Grouped Unit, New Function Function designed to handled palettes, wind towers or any type of unit, enable to stack unit in varies ways
See the Manual > Cargo Functions > Grouped Unit (this function can save you a lot of time and reduce file size) Moving Units New system to check under laying units and ships structure, each moved unit is checked in each end of unit Fx so a unit do not drop to the tanktop mowing over a gab of Twd Magazine aft above hatch cover level, unit adjusted accordantly The function is a part of the Gravity and construction s check Disable to disable the function Errors All errors reported in Ver. 3.29 and 3.30 (actually very few reports ) have been checked, and the error successfully found and corrected The comment errors have occurred in the module Load_One_Unit_From_List (handling loading of units) and frmcad.doct_onactiondraw ((BaseDoc) handling a moved unit) This two and others main functions have been added its own error handling, correcting any problem during executing, if possible if not you get the error dialog. Manual The manual has been updated, and a new main topic added Frequently Asked Questions (FAQ) It is recemented to read the FAQ, so if you are having a problem you might find the solution here If not do not hesitate to contact me Version 3.30 Dated 17-08-2017 Err corrections Snap lines Save and ReLoad DAO have been replaced by ADODB (Microsoft ActiveX Data Objects 6.1 Library) Version 3.29 Dated 24-07-2017 Corrections UserCAD
Object snap Block Editor, you can have several of block open as block editor LoadPlanner Working with object snap and snap lines updated New in this version Update max load for each tank top and hatch covers in Hold Dimensions and update the poly layer Also update Max Load mt/m2 for tweendecks and hatch covers in unit s proprieties and the information s text will show max load Manual updated Version 3.28 Dated xx-05-2017 New in this version UserCAD Updated The UserCAD have been converted to a multiple document interface (MDI) List Administrator > Loaded List > Export > Excel as weight list Version 3.27 Dated 29-05-2017 New in this version List Administrator > Loaded List > Export > Excel as weight list The Excel list can be used as input for others stability programs, if function is available Updated Matrix The system has been updated in a long range of functions as Pipe calculations Bulk Loading Units Properties (Set units pin color added) Bugs Entries in sub layers is moved to its main layer (BBC Amber)
Version 3.20 to 3.26 Installations problems on target machine do to Microsoft Data Access Objects (DAO) 3.6 Library DAO is from 1997 and is used to convert old ship files from the old LoadPlanner and being replaced by Microsoft ActiveX Data Objects 6.1 Library, once completed the system will be available in 64bit Version 3.19 Dated 22-02-2017 Pipes calculations Correction to tier calculations, no of pipes in bottom tier Text in Pipes block updated with all given info as Tier limit dunnage between tiers etc. Sequence list updated Incorrect base point when moving Views in Model Plan corrected Hidden Side view and / or All over aft view corrected when reloading project file A long range of others corrections Version 3.18 Dated 09-02-2017 Updated server connection Version 3.17 Dated 04-01-2017 Printing problems from Adobe Reader Some experience printing problems printing from Adobe Reader, this is typical coursed when many units having transparent colors in a small area of the drawing, typical the All over aft view To avoid this problem, the side and aft view are as default set as none transparent, under Text and Color menu the transparent can be switch on or off. A other way to solve the problem is to take the All over aft view this will also reduce the pdf file size with about 25% However, should the problem still occur, set the printer setting under Advance setting to Print as Image New server A new server has been set up, therefore all versions earlier than 3.17 will not be able to Activate or Deactivate license Version 3.14 Dated 14-12-2016 Setup of user defined frames, see the manual Crating frames in UserCAD Bugs. Have seen some project files given error when opening, some of those errors coursed do to so called Bad blocks Blocks coming from 2 nd part cad programs compatible with dwg, VD programmers have updated the matrix to handling those blocks and if possible, as in most cases, the blocks will be added correct, if not those blocks will be deleted, so a file all ways can be opened. It is strongly recommended you update the LoadPlanner CAD DWG file support Var. corrections Version 3.13 Dated 24-11-2016
Var Corrections Version 3.12 Dated 22-11-2016 Corrections to cargo block(s) handling Version 3.11 Dated 14-11-2016 Corrections to bulk loading Corrections to creating container grid Version 3.10 Dated 08-11-2016 New text handling for unit s text, No upside down or mirrored text Snap lines updated Import of packing list, updated include color marking Version 3.08 Dated 18-10-2016 Creations of new container grid corrected Edit of blocks in block, UserCAD Summaries of total cargo loaded in Title Block Version 3.07 Dated 10-10-2016 Bugs fix / Corrections Units Properties Copy wind mill towers to new unit, stackable cradle included, once saved Load List updated Change of block dimension, Stove factor updated Color selections for Pol, Pod and Reference direct uprated, do not require Save Container Grid Edit of max bays Import of packing list Colon 0 readable, New Function Load List > Tools > Copy as Loaded, copy all units as shown on list Version 3.06 Dated 04-10-2016 Correction to user s incorrect ship setting Version 3.05 Dated 02-10-2016 (Major update)
A long range of functions updated, it might be required that you update your stanchion file Select Design> Auto Update all if you find any error or incorrect behavers update your stanchion file Moving of object have been redefined, before moving a unit it might have given some flashing on screen, due to redrawing, this have been eliminated The activations and deactivations has added an error tapping, if any errors occur pls. forward error massaged New functions Creations of Hatch Covers, handling of same Creations of Tweendeck, handling of same Grid Loading, enter individual distance between each grid cells. Select units from Load List Quay area, Save As, the shown unit on the quay area can be saved to any supported file type for use in others programs. Systems Layer, under Design, create Twd setting side view generate a twd layer making each twd positions, modified the layer for additional twd settings and add bulkhead setting. Use snap options to move twd side view in order to snap to given positions. The given Lcg and Set Height can be entered in the Units Properties, press Enter and the twd is moved to given position, do not click Save as default setting will be change Layer Dialog box, System or User Layers can be edited direct in the Plan Model in relations to other layers Version 3.04 Dated 02-10-2016 Test Version, not published Version 3.03 Dated 24-08-2016 New function LoadPlanner Explore Select any old LP 4.x Ship file, Select the function Convert to LP CAD Stanchion Follow the guide to convert the old ship file. The converting of old ship file has been updated, include correct scaling of bitmap, black area etc. General update to a long range of functions. Version 3.01 Dated 17-07-2016 Error in activation and deactivation of installations fixed Update to varies functions Version 3.00 Dated 28-06-2016 New Functions in LoadPlanner Unit Snap Options, dialog box, Enable / Disable snap options, set snap distance or use the
Snap options on the menu bare Snap selected on the menu bar override snap options selected in the Unit Snap Dialog box, to enable / disable press the S key Units pop up text, enable / disable under Text and Color on main menu bar, for existent file run a text update before enabled. Layout > Create / Update 20ft Bay plan Add a 20ft bay plan to Plan Model. The bay plan is added as a block and are inactive, to update just run the functions. Note if the bay plan is shown in-correct you have to update the container grid under Design or if no units shown select Cargo Model and return to Plan Model run Create / Update 20ft Bay plan New Layout dialog box. Add viewport Pick on screen select the area of the Plan Model to be added to the viewport. List Administrator > Ship equipment > Setting > Update all TWD Function update all tweendeck according to main setting, and redraw all New LoadPlanner CAD file converter, required in order to convert AutoCAD dwg filer Download LoadPlanner CAD dwg file support (Note: existent vdfileconverter4 to be uninstalled before new can be installed) Version 2.9 Dated 02-06-2016 New function Top View Plan. LoadPlanner / File > New > Top View Plan Open any compatible drawing and use it as a top view plan, if the drawing needs to be scaled first open the drawing in UserCAD, scale the drawing. More info in the manual Setup LoadPlanner / Tools > Setup Change model back ground color or Mouse wheel scale factor Container grid in cargo model 20 and 40 feet container snap to the container grid, when the container grid in on only Updated Culture setting, the systems no longer use windows default, but own UK-US setting New Matrix improving loading speed and text handling Corrections made to Loading from Quay area, Updating of Load List, Export to Excel, Title block Updated manual Varies update, corrections and improving
Version 2.8 Dated 09-05-2016 Varies update and corrections Version 2.7 Dated 02-05-2016 New Functions Bulk loading added to the Grid dialog box. Under the Design function: Container grid, edit or setup new container grid, create sub layers related to the container grid. Stability setup, guide for import of hydrostatic data and tanks data. General update and improved Version 2.5 Dated 25-02-2016 Vital error in Units properties corrected (Quantity amend to 1) Load Align corrected and updated New functions Units Properties Convert existed unit to block File Save dialog box, Print to PDF added, to be used if Save to PDF extend above allowed file size Version 2.4 Dated 23-02-2016 New file diagnostics at opening files, checking the Poly Layer and updating the file if errors found This to laminate a long range of errors popping up due to incorrect poly layer Quay Area New filter functions Flying Units Final found the problem and now corrected, so should now be history. Version 2.3 Dated 17-02-2016 Errors course by missing data s saved under design, User will be notified to save data Occurred in Weight Dis.,Grid Load and Block shape Units properties Loading of 20ft Container in the 20ft container grid corrected
Legal characters in file names removed and max file length sat to 120 characters Note: Windows XP and older version of 7. You have to set windows to allowed long file names, else max length 31 characters Correction to changes of dimensions of loaded wind towers Version 2.2 Dated 10-02-2016 List Administrator, Import Max text string length 120 sign to be imported, text longer only the left 120 sign will be imported, use Note if longer text string is needed. Function Split UP All corrected. Cargo Model. Using the N key to load next unit in line form Load list or Quay area, now loaded at present curses positions This should end units hanging at AP Ship equipment Handling of ship equipment updated, Tweendecks and hatch covers base point / setting forced updated from Units Properties dialog box when click Save. New Layout > Weight Distribution updated Version 2.0 Dated 30-02-2016 First full licensed version, include updated matrix This version contains a long range of improvement and updated function All issues reported so far have been corrected, but be aware of older project files can enclose earlier issues So if reporting a problem, then only for project created in version 2.0 This version requires a Product key to run first time. The same product key allows to activate the numbers of installations as agreed. Office versions allow users to have 2 installations, but only under same user name. So to activate first installations use Login and 2 nd Login for 2 nd installations To activate or deactivate a license the system to be online, all depend of user rights on the system it might be that the program have to start up with administrator privileges. In order to move one license form one user to another or from one pc to another, the installations have to be deactivated, before it can be activated. Be aware if a user continues activate and deactivate between several computers, the licenses might be blocked.