FL SWITCH SFN(T) 16-Port Standard Function Ethernet Switches for Normal and Extreme Environments. AUTOMATION Data Sheet 2806_en_C

Similar documents
FL SWITCH SFNB. Five- and Eight-Port Standard Function Ethernet Switch with Narrow Housing. AUTOMATION Data Sheet 2642_en_H.

PHOENIX CONTACT - 10/2009

PHOENIX CONTACT - 02/2007

PHOENIX CONTACT - 06/2006

FL MC 2000E (SM40) LC

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

FL SWITCH LM 8TX(-E) FL SWITCH LM 4TX/2FX(-E) FL SWITCH LM 4TX/2FX SM(-E)

PHOENIX CONTACT - 11/2008

FL SWITCH Factoryline 5- and 8-port managed switches with optional fiber optic ports and wide temperature ratings. Data sheet.

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

TRIO-DIODE/12-24DC/2X10/1X20

PHOENIX CONTACT - 07/2006

PHOENIX CONTACT - 04/2008

FL SWITCH 8TX. Extract from the online catalog. Discontinued item. Order No.:

onlinecomponents.com

FL SWITCH SFN 5TX. Extract from the online catalog. Order No.:

This data sheet is only valid in association with the IL SYS INST UM E user manual.

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

Stride Industrial Ethernet Switches

MINI-PS AC/10-15DC/8

Valueline Industrial PC

Redundancy Module QUINT-DIODE/40

Ha-VIS econ 2000 Fast and Full Gigabit Ethernet Basic. Features

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet

Hardened PoE Ethernet Switch

FL MC EF 1300 SM SC. FO converter with SC duplex fiber optic connection (1300 nm), for converting 10/100Base-T(X) to single-mode fiberglass (9/125 μm)

Stride SE2 Series Unmanaged Industrial Ethernet Switches and Media Converters

QUINT-BUFFER/24DC/24DC/40

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

PHOENIX CONTACT - 05/2007

RAD-WHG/WLAN-XD. WirelessHART gateway with integrated WLAN (802.11b/g) INTERFACE Data Sheet 2720_en_C. 2 Features. 1 Description

QUINT-PS-3x AC/24DC/10

Quick Start Guide Elinx ESW200 Series. 5 and 8 port Unmanaged Ethernet Switch

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT Features

XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment

User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX

IES User Manual. 6 GE + 2 SFP Unmanaged Switch -20 to 60C, DIN-rail. v

Industrial Ethernet Switch

STEP-PS/1AC/24DC/1.75

Industrial 3-Port Fast Ethernet Media Converter Switches

PSI-MODEM-SHDSL/PB. Broadband PROFIBUS extender, SHDSL PROFIBUS leased line modem. Data sheet _en_03. 1 Description. 1.

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

ETD-BL-1T-OFF-CC- 10S

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Rugged MediaConverter

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features

1 10/100TX FX w/ 1 PoE Injector Industrial Switch. User Manual

PHOENIX CONTACT

Quick Start Guide. Physical Description. The Port Status LEDs

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

FL MC EF 1300 MM ST. FO converter with B-FOC (ST ) connection (1300 nm), for converting 10/100Base-T(X) to multi-mode fiberglass (50/125 µm)

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

onlinecomponents.com

PSI-MODEM-SHDSL/SERIAL

AXL BK PN (-ME) Axioline bus coupler for PROFINET IO. Data sheet. 1 Description

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

Quick Start Guide Elinx ESW100 Series. 5 and 8 port Unmanaged Ethernet Switch

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

Hardened Media Converter

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1

PSR-PS21. SIL coupling relay. Data sheet. 1 Description

Power Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground

PI-EX-ME-2NAM/COC-120VAC

MINI MCR-SL-UI-2I(-SP)(-NC)

MINI MCR-SL-PT100-UI-200

MINI MCR-SL-PT100-UI(-SP)(-NC)

HARTING econ 3000 Introduction and features

PI-EX-ME-2NAM/COC-24VDC

TF501, TF521 Terminal Bases

Device Server for the conversion of serial interfaces (RS-232/422/485) to IP.

10/100TX to 100FX w/ 1 PoE Injector Industrial Media Converter User Manual

Industrial Switches Industrial Switches

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

LNP-0602 series. 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx. User Manual

Hardened Web-Smart PoE & High Power PoE Ethernet Switch

gigabit industrial ethernet user manual Models , ,

FL MC EF WDM... Ethernet FO converter for bidirectional data transmission via a single optical fiber (SC simplex) Data sheet.

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

QUINT-PS/ 1AC/24DC/ 5

TU531, TU532 Terminal Unit

PHOENIX CONTACT - 12/2007

PHOENIX CONTACT - 01/2007

Power Supply, Primary Switch Mode for Universal Use QUINT-PS AC/48DC/5

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

AO523 Analog Input Module

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

PSM-ME-RS485/RS485-P. Repeater for RS wire bus systems. Data sheet. 1 Description

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

EL1142 Series. IEC / IEEE 1613 Hardened 2-Port 10/100BASE-TX to 2-Port 100BASE-FX Media Converter. User s Guide

Industrial Ethernet Switch. Signamax Connectivity Systems. Industrial Ethernet Switch. Model A Series. User s Guide

FB-6SP and FB-12SP. Block device couplers. Data sheet 3177_en_A. 2 Features. 1 Description

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

Transcription:

16-Port Standard Function Ethernet Switches for Normal and Extreme Environments AUTOMATION Data Sheet 2806_en_C 1 Description PHOENIX CONTACT 2011-06-28 2 Features and Benefits The FL SWITCH SFN(T) 16(15)(14)TX range of Factory Line switches can be used for quick and cost-effective Ethernet network expansion to the field level. These unmanaged switches provide simple, robust networking in an industrial environment. Due to the narrow housing design, the switches are suitable for use in control cabinets and junction boxes. The FL SWITCH SFNT switches allow operation across a wider temperature range than most switches, allowing networks to expand into process industry environments, such as oil/gas, chemical, water/wastewater, wind energy, security, and monitoring. The FL SWITCH SFN(T) 16(15)(14)TX switches support the auto negotiation function on the RJ45 ports and offer transmission speeds of 10/100 Mbps. Mixed operation for the connection of segments with different data transmission speeds is also supported. The RJ45 ports offer an autocrossing function, which means it is not necessary to make a distinction between 1:1 and crossover cables. Fiber optic ports are available in an SC format and offer speeds of 100 Mbps. The fiber optic ports extend the segment length to 2000 m or more, depending on the quality of the fiber optic cable. -40 to 75 C operating range for SFNT switches 0 to 60 C operating range for SFN switches Auto-negotiation and autocross simplify cabling Couple copper network segments with different bit rates with automatic detection of the data transmission speed of 10 or 100 Mbps Individual LEDs at each port indicate communication activity and data rate Redundant power supply capable with local (LED) and remote (dry contact) alarms to indicate failure of one or both power supplies Available fiber optic options for extended distance and electrical noise immunity Fiber optic ports available in SC formats This data sheet is valid for all products listed on the following page: Make sure you always use the latest documentation. It can be downloaded at www.phoenixcontact.net/catalog.

3 Ordering Data Description Type Order No. Pcs./Pkt. Ethernet switch, with 16 RJ45 ports for 10/100 Mbps FL SWITCH SFN 16TX 2891933 1 Ethernet switch, with 15 RJ45 ports, 1 fiber optic port in SC format for FL SWITCH SFN 15TX/FX 2891934 1 10/100 Mbps Ethernet switch, with 14 RJ45 ports, 2 fiber optic ports in SC format for 10/100 Mbps FL SWITCH SFN 14TX/2FX 2891935 1 Ethernet switch, wide temperature, with 16 RJ45 ports for 10/100 Mbps FL SWITCH SFNT 16TX 2891952 1 Ethernet switch, wide temperature, with 15 RJ45 ports, 1 fiber optic port in FL SWITCH SFNT 15TX/FX 2891953 1 SC format for 10/100 Mbps Ethernet switch, wide temperature, with 14 RJ45 ports, 2 fiber optic ports in SC format for 10/100 Mbps FL SWITCH SFNT 14TX/2FX 2891954 1 Accessories Description Type Order No. Pcs./Pkt. Universal end clamp E/NS 35 N 0800886 50 Patch angle with 2 ports in CAT 5e FL PF 2TX CAT5E 2891165 1 Patch angle with 8 ports in CAT 5e FL PF 8TX CAT5E 2891178 1 Patch angle with 2 ports in CAT 6 FL PF 2TX CAT6 2891068 1 Patch angle with 8 ports in CAT 6 FL PF 8TX CAT6 2891071 1 Patch angle with security elements for 2 ports in CAT 5e FL PF SEC 2TX 2832687 1 Patch angle with security elements for 8 ports in CAT 5e FL PF SEC 8TX 2832690 1 Patchbox 8 x RJ45 CAT 5e, pre-assembled, can be retrofitted FL PBX 8TX 2832496 1 Patch cable, CAT 5, pre-assembled, 0.3 m long FL CAT5 PATCH 0,3 2832250 10 Patch cable, CAT 5, pre-assembled, 0.5 m long FL CAT5 PATCH 0,5 2832263 10 Patch cable, CAT 5, pre-assembled, 1.0 m long FL CAT5 PATCH 1,0 2832276 10 Patch cable, CAT 5, pre-assembled, 1.5 m long FL CAT5 PATCH 1,5 2832221 10 Patch cable, CAT 5, pre-assembled, 2.0 m long FL CAT5 PATCH 2,0 2832289 10 Patch cable, CAT 5, pre-assembled, 3.0 m long FL CAT5 PATCH 3,0 2832292 10 Patch cable, CAT 5, pre-assembled, 5.0 m long FL CAT5 PATCH 5,0 2832580 10 Patch cable, CAT 5, pre-assembled, 7.5 m long FL CAT5 PATCH 7,5 2832616 10 Patch cable, CAT 5, pre-assembled, 10.0 m long FL CAT5 PATCH 10 2832629 10 Security element for FL CAT patch FL PATCH SAFE CLIP 2891246 20 Color marker for FL PATCH GUARD, black FL PATCH GUARD CCODE BK 2891136 12 Color marker for FL PATCH GUARD, blue FL PATCH GUARD CCODE BU 2891233 12 Color marker for FL PATCH GUARD, orange FL PATCH GUARD CCODE OG 2891330 12 Color marker for FL PATCH GUARD, yellow FL PATCH GUARD CCODE YE 2891437 12 Color marker for FL PATCH GUARD, turquoise FL PATCH GUARD CCODE TQ 2891534 12 Color marker for FL PATCH GUARD, green FL PATCH GUARD CCODE GN 2891631 12 Color marker for FL PATCH GUARD, red FL PATCH GUARD CCODE RD 2891738 12 Color marker for FL PATCH GUARD, violet FL PATCH GUARD CCODE VT 2891835 12 Security element for FL PATCH FL PATCH GUARD 2891424 20 FL PATCH GUARD, key FL PATCH GUARD KEY 2891521 1 Dust protection cap FL RJ45 PROTECT CAP 2832991 10 2806_en_C PHOENIX CONTACT 2

4 Technical Data General Data Function Switch/repeater; conforms to standard IEEE 802.3 Latency of the communication processor 8 µs plus frame time Housing dimensions (width x height x depth) 70 x 135 x 110 mm Weight, without connectors 870 g Operating temperature FL SWITCH SFN FL SWITCH SFNT 0 C to 60 C -40 C to 75 C Storage temperature -40 C to 85 C Degree of protection IP20, DIN 40050, IEC 60529 Protection class Class 3 VDE 0106; IEC 60536 Humidity (operation and storage) 5% to 95%, no condensation Air pressure (operation) FL SWITCH SFN FL SWITCH SFNT Air pressure (storage) FL SWITCH SFN FL SWITCH SFNT 86 kpa to 108 kpa, 1500 m above sea level 62 kpa to 108 kpa, 4160 m above sea level 66 kpa to 108 kpa, 3500 m above sea level 62 kpa to 108 kpa, 4160 m above sea level Mounting NS35 (EN 60715) Preferred mounting position Perpendicular to a standard mounting rail Connection to protective earth ground Snapped onto a grounded mounting rail Supply Voltage (U S ) Connection type Removable, screw-clamp connector Wire size (solid/stranded/awg) 0.2 to 2.5 mm 2 / 0.2 to 2.5 mm 2 / 30-12 AWG Torque 0.6-0.8 Nm (5-7 lb f -in.) Recommended PE wire size 2.5 mm 2 Nominal power supply 24 V DC Permissible ripple 3.6 V pp within the permissible voltage range Permissible voltage range 12 V DC to 48 V DC Test voltage 500 V DC for one minute Protection against polarity reversal Present Current Consumption and Inrush Current Current Consumption (max) Inrush Current FL SWITCH SFN(T) 16TX 550 ma @ 12 V DC 275 ma @ 24 V DC 9.85 A @ 30 µs FL SWITCH SFN(T) 15TX/FX 630 ma @ 12 V DC 315 ma @ 24 V DC 9.7 A @ 30 µs FL SWITCH SFN(T) 14TX/2FX 715 ma @ 12 V DC 350 ma @ 24 V DC 10.0 A @ 30 µs Interfaces Total number of RJ45 Ethernet interfaces 14/15/16 MAC Address Table Size (Entries) 4 K Properties of RJ45 Ports Connection format 8-pos. RJ45 female connector on the switch Connection medium Twisted-pair cable with a conductor cross section of 0.14 mm 2 to 0.22 mm 2 Cable impedance 100 Ω Transmission speed 10/100 Mbps Maximum network segment length 100 m Properties of Fiber Optic Ports Connection format SC duplex female connector Fiber type Multimode Laser protection Class 1 according to DIN EN 60825-1:2001-11 2806_en_C PHOENIX CONTACT 3

Interfaces (Continued) Transmission rate Wavelength Fiber optic segment length Transmission power (medium type) dynamic (average) Minimum Maximum Transmission power (medium type) static Minimum Maximum Receiver sensitivity Minimum Maximum Alarm Contacts Voltage Current carrying capacity 100 Mbps full duplex 1300/1310 nm 12.1 km glass fiber with F-G 62.5/125 0.7 db/km F1000 3.3 km glass fiber with F-G 62.5/125 2.6 db/km F600 7.1 km glass fiber with F-G 50/125 0.7 db/km F1200 3.1 km glass fiber with F-G 50/125 1.6 db/km F800-23.5 dbm (50/125 µm) / -20 dbm (62.5/125 µm) -14 dbm (50/125 µm) / -14 dbm (62.5/125 µm) -22.5 dbm (50/125 µm) / -19 dbm (62.5/125 µm) -14 dbm (50/125 µm) / -14 dbm (62.5/125 µm) -31 dbm (dynamic) / -31 dbm (static) -14 dbm (dynamic) / -14 dbm (static) 24 V DC 1 A maximum including inrush Mechanical Tests Shock test according to IEC 60068-2-27 Operation: 25g, 11 ms period, half-sine shock pulse Storage/transport: 50g, 11 ms period, half-sine shock pulse Vibration resistance according to IEC 60068-2-6 Operation/storage/transport: 5g, 150 Hz, Criterion 3 Free fall according to IEC 60068-2-32 1 m Conformance With EMC Directives Developed according to IEC 61000-6-2 IEC 61000-4-2 (ESD) IEC 61000-4-3 (radiated-noise immunity) IEC 61000-4-4 (burst) IEC 61000-4-5 (surge) IEC 61000-4-6 (conducted noise immunity) IEC 61000-4-8 (noise immunity against magnetic fields) EN 55022 (noise emission) Approvals General Hazardous location Contact: ±4 kv, Criterion B Air: ±8 kv, Criterion B 10 V/m, Criterion A Ports: ±1 kv, Criterion B DC power: ±2 kv, Criterion B Ports: ±1 kv, Criterion B DC power: ±500 V, Criterion B 10 V rms, Criterion A 30 A/m, Criterion A Class A c u ROHS EEE 2002/95/EC, WEEE 2002/96/EC U Class I, Zone 2 AEx nc IIC T4, EX nc nl IIC T4 X U Class I, Division 2 Groups A, B, C, D, T4 2806_en_C PHOENIX CONTACT 4

X1 FL SWITCH SFN(T) 5 Overview Alarm connector Power connector 6 Requirements for Operation in Hazardous Locations WARNING: These instructions must be followed for proper use in hazardous locations. X1 FL SWITCH SFNT 15TX/FX Ord.No. 2891953 US1 US2 Link/ACT Power LEDs (US1 and US2) Link/ACT LEDs The device must be installed within an enclosure rated at least IP54. Do not open the enclosure unless power has been switched off or the area is known to be non-hazardous. Provisions shall be made to prevent the rated voltage from being exceeded by transient disturbances of more than 40%. 7 Installation Figure 1 Connectors and LEDs ( 15TX/FX shown) 5.1 Diagnostic and Status Indicators Des. Color Status Meaning US1 and US2 green ON Supply voltage (US) in the tolerance range OFF Supply voltage (US) too low Link/ACT green ON Valid network connection Flashing Transmitting or receiving data At high data rates the Link/ACT LED blinking may appear to be a constant rate. CAUTION: Only qualified personnel may start up and operate this device. Qualified personnel are persons authorized to start up, ground and mark devices, systems, and equipment according to the standards of safety technology. NOTE: The FL SWITCH SFN(T) module is designed for SELV and PELV operation according to IEC 61140/EN 61140. Install the FL SWITCH SFN(T) on a clean NS 35 rail. To avoid contact resistance, use only clean, corrosion-free rails that meet the EN 60715 standard. End clamps can be mounted on both sides of the module to stop the modules from slipping on the rail. NOTE: Connect the mounting rail to protective earth ground using a grounding terminal block. The modules are grounded when they are snapped onto the rail. Connect protective earth ground with low impedance. 7.1 Assembly 1. Place the module onto the rail from above. The upper holding keyway must be hooked onto the top edge of the rail. 2. Push the module from the front towards the mounting surface. 3. Once the module has been snapped on properly, check that it is fixed securely on the rail. 2806_en_C PHOENIX CONTACT 5

7.2 Removal 1. Insert a suitable tool (e.g., needle-nose pliers) into the arresting latch and pull it down. 2. Pull the module slightly away from the mounting surface. 3. Lift the module from the rail. + 7.3 Power Connection The switch is designed for SELV and PELV operation at +24 V DC according to IEC 61140/EN 61140. Only SELV and PELV according to the defined standards may be used for supply purposes. The FL SWITCH SFN(T) 16(15)(14)TX switches provide the ability to connect redundant power supplies (see Figure 2). If redundant power supply is not required, a single power supply can be used (see Figure 3). Snapping the switch onto a grounded rail connects it to the ground potential. In an environment particularly prone to EMI, noise immunity can be increased by an additional lowimpedance connection to protective earth (see Figure 2 and Figure 3). X18 X17 R2 GND US2 GND US1 R1 + + Figure 3 X18 X17 R2 GND US2 GND US1 R1 Power connections for single power supply 7.4 Alarm Contact The FL SWITCH SFN(T) 16(15)(14)TX switch provides contacts (R1, R2) for remote monitoring if a power failure is detected. Alarms are triggered if one or both power supplies fail. The alarm relay is a normally closed type. When there are no faults, the contact is held open. When a fault occurs, the relay is de-energized to close the contact. X18 X R2 GND US2 GND US1 R1 Figure 2 Power connections for redundant power supply Figure 4 Remote monitoring connection 2806_en_C PHOENIX CONTACT 6

X1 FL SWITCH SFN(T) 7.5 Ethernet Interface The FL SWITCH SFN(T) has 14, 15, or 16 Ethernet ports on the front in RJ45 format to which only twisted-pair cables with an impedance of 100 Ω can be connected. The data transmission speed is 10/100 Mbps. In addition, every port has an autocrossing function: it is not necessary to make a distinction between 1:1 or crossover Ethernet cables. evaluating the source addresses in the data telegrams. Only packets with unknown addresses, with a source address of this port or with a multicast/broadcast address in the destination address field are forwarded via the corresponding port. The switch can store addresses in its address table with an aging time of 5 minutes. This is important when more than one termination device is connected to one or more ports. In this way, several independent subnetworks can be connected to one switch. A restart deletes the entire address table. RJ45 9 Dimensions 10 mm 8 7 6 5 4 3 2 1 n.c. TD- n.c RD- n.c. n.c. ṪD+ RD+ FL SWITCH SFNT 15TX/FX Ord.No. 2891953 US1 US2 X1 Link/ACT Figure 5 RJ45 pin assignment 8 Switching Characteristics Store and Forward All data telegrams received by the switch are saved and their validity checked. Invalid or faulty data packets (> 1522 bytes or CRC errors) and fragments (< 64 bytes) are rejected. Valid data telegrams are forwarded by the switch. The switch always forwards the data using the data transmission speed that is used in the destination network segment. 135 mm Multi-Address Function 70 mm The switch independently learns the addresses for termination devices, which are connected via a port, by Depth = 110 mm 2806_en_C PHOENIX CONTACT GmbH & Co. KG 32823 Blomberg Germany Phone: +49-(0) 5235-3-00 7 PHOENIX CONTACT P.O. Box 4100 Harrisburg PA 17111-0100 USA Phone: +717-944-1300 www.phoenixcontact.com