Optimize Your Data Center. Gary Hill VP, Business Development DVL Group, Inc.

Similar documents
SmartRow Solution Intelligent, Integrated Infrastructure for the Data Center

SmartRow Intelligent, Integrated Infrastructure in a Self-Contained Line-Up. Solutions For Business-Critical Continuity

Smart Solutions Intelligent, Integrated Infrastructure for the Data Center

SMART SOLUTIONS TM INTELLIGENT, INTEGRATED INFRASTRUCTURE FOR THE DATA CENTER

SmartAisle Intelligent, Integrated Infrastructure Using Row-based Building Blocks. Solutions For Business-Critical Continuity

SMARTAISLE Intelligent, Integrated Infrastructure for the Data Center

PLAYBOOK. How Do You Plan to Grow? Evaluating Your Critical Infrastructure Can Help Uncover the Right Strategy

Data Center Infrastructure Management Creating The Efficient Converged Data Center

84 kw, Tier 3, Direct Expansion, 937 ft 2

Move beyond the expected.

APPLYING DATA CENTER INFRASTRUCTURE MANAGEMENT IN COLOCATION DATA CENTERS

SmartMod Intelligent, Integrated Infrastructure for the Data Center

How Liquid Cooling Helped Two University Data Centers Achieve Cooling Efficiency Goals. Michael Gagnon Coolcentric October

SmartCabinet Intelligent, Integrated Containment for IT Infrastructure

IBM Site Enablement Services

3300 kw, Tier 3, Chilled Water, 70,000 ft 2

Data Center Optimized Controls

Changing the way companies run their data centers

DATA CENTER COLOCATION BUILD VS. BUY

Datacentre Newbridge Data sheet

DCIM Solutions to improve planning and reduce operational cost across IT & Facilities

Engineering & Support Services

Next Generation Cooling

Data Center Infrastructure Management (D.C.I.M.)

Datacentre Reading East 2 Data sheet

THE NEW WORLD OF IT INFRASTRUCTURE SOLUTIONS. Enabling an IT Infrastructure as Dynamic as Your Business

The Efficient Enterprise. All content in this presentation is protected 2008 American Power Conversion Corporation

9.6 MW, Traditional IT and OCP-compatible, Indirect Air Economizer, m 2

Getting Power Peace of Mind with Remote Data Center Monitoring and Management Through EcoStruxure IT

EXTENDING THE LIFECYCLE OF AGEING DATA CENTRES:

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

1008 kw, Tier 2, Chilled Water, ft 2

SIX Trends in our World

5.2 MW, Pod-based build, Chilled Water, ft 2

survey, 71% of respondents listed Improving capacity planning as a top driver for buying DCIM 1.

Predictive Resilience: Leveraging Integrated DCIM to Reduce Data Center Downtime

2000 kw, Tier 3, Chilled Water, Prefabricated, sq. ft.

The Most Comprehensive DCIM Solution

200 kw, Tier 3, Chilled Water, 5250 ft 2

San Francisco Chapter. What an auditor needs to know

SMARTMOD Intelligent, Integrated Infrastructure for the Data Center

DATA CENTRE & COLOCATION

Schneider Electric Data Center Software

Trellis Platform. for Data Center Infrastructure Management (DCIM)

POWER AND THERMAL MANAGEMENT SOLUTIONS

Datacentre Milton Keynes Data sheet

Variable Density, Closed-Loop, Water-Cooled Data Center Solution

Create a sustainable, high-performance university campus.

FOM 2.4 The Performance Indicator: Assessing & Visualizing Data Center Cooling Performance

Data Centre Solutions. Data Centre Solutions Expertly Engineered

Powering Transformation With Cisco

siemens.com/dcim We are the trusted technology partner for energy-efficient, safe and secure buildings and infrastructure.

HPC Solutions in High Density Data Centers

INNOVATE DESIGN APPLY.

INNOVATE DESIGN APPLY.

Thermal management. Thermal management

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

Taking The Heat Off University of East Anglia Data Centre

Virtualization and consolidation

DCIM and how it helps deliver the InteropNet. Paul Goodison CEO, Cormant Inc CORMANT

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

DCIM Data Center Infrastructure Management Measurement is the first step

83951c01.qxd:Layout 1 1/24/07 10:14 PM Page 1 PART. Technology Evolution COPYRIGHTED MATERIAL

Modular & Mobile Data Centre Solutions. Data Centre Solutions Expertly Engineered

Energy Logic: Emerson Network Power. A Roadmap for Reducing Energy Consumption in the Data Center. Ross Hammond Managing Director

Power Consumption in the Data Center. Green Concepts

IT your way - Hybrid IT FAQs

Comprehensive Data Center Energy Management Solutions

ARTO LIND ABB Ability Datacenter Automation. The way to monitor & control your DC infrastructure (DCIM) Datacenter Infrastructure Management

Liebert. APM from 30 to 300 kw. The Compact Row Based UPS With FlexPower Technology

RFP Questions Guideline For Data Center Buyers

The Four 4R s. of Data Center Airflow Management. About Upsite Technologies

:: While reducing energy costs remains a factor, the most commonly reported driver of DCIM investment plans is capacity planning -Gartner*

Checklist for building an edge data center

Two-Stage Power Distribution: An Essential Strategy to Future Proof the Data Center

VERTIV SERVICE CAPABILITY

Compute Engineering Workshop March 9, 2015 San Jose

Considerations on Evaluating a DCIM Solution

Campus IT Modernization OPERATIONAL CONTINUITY FLEXIBLE TECHNOLOGY MODERNIZED SYSTEMS

Data Centre Solutions Expertly Engineered APC Management Software

1.866.TRY.GLCC WeRackYourWorld.com

Data Center Infrastructure Management ( DCiM )

Data Centre In A Box

Newave s approach for protecting mission critical application

Smart Data Centres. Robert M Pe, Data Centre Consultant HP Services SEA

Datacentre Milton Keynes Hall C Data sheet

Trellis Real-Time Infrastructure Optimization Platform Release Notes Version December 23, 2016

APC by Schneider Electric Elite Data Centre Partner

ACHIEVING A NEW LEVEL OF DATA CENTER PERFORMANCE. Optimizing Availability, Capacity and Efficiency with DCIM Solution from Vertiv

Survey and Audit Service Schedule. Airflow and Thermal Imaging Survey Service Schedule. Data Centre Solutions Expertly Engineered

Where s the Heat Coming From. Leland Sparks Global Account Technical Consultant Belden

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

Electrical Products Group Conference

DCIM Data Center Infrastructure Management

Make the most of your Energy from Power Plant to Plug. Chris Simard, Regional Director Field Sales Group

Unleash IT to Accelerate Radical Business Innovation. Hyperconverged Infrastructure Powered by Lenovo ThinkAgile HX Series with Nutanix

IBM Integrated Server Farm (ISF)

<Insert Picture Here> Austin Data Center 6Sigma DC CFD Model

Raytheon s Strategic IT Energy and Resource Management Program

High Performance Computing (HPC) Data Center Proposal

Transcription:

Optimize Your Data Center Gary Hill VP, Business Development DVL Group, Inc.

Data Center Age Profile Gartner Group Survey

Legacy Data Centers Challenges Under Powered - Room or Racks Inadequate Air Delivery Inadequate Monitoring Capabilities Inefficient Cooling Cabling Challenges Budget 3

Choices in Handling Change Build Cloud Colocation The Best Choice May Be To Extend the Life of Your Existing Data Center 4

Extend the Life of the Data Center FACT: Pressures on cost will increase Step 1: Unlock hidden or stranded capacity Assessments & Audits Under-utilized servers Virtualization Decommission servers Redeploy power & cooling Step 2: Improve Measuring & Monitoring Define, Measure, Analyze, Control Step 3: Densify Your Data Center 5

Visualize the data center floor Avocent Data Center Planner Inventory Mapping and Planning Tool for Physical Devices in Data Center Visualize infrastructure down to the rack Model current and future rack capacities Track equipment throughout its lifecycle Perform what if scenarios

Reduce time to provision equipment Avocent Data Center Planner Less time required to plan equipment installs Optimize installation based on available space, power & air

Track Rack Capacity - Power, Cooling, Space Avocent Data Center Planner Effectively Manage The Data Center as a System

Extending The Life of Your Data Center

Intelligent, integrated infrastructure in a self contained line-up Needs Addressed Integrated design Standardization Low 1 st cost & operating cost Availability Speed of deployment Applications Capacity: 20kW Racks: 3-6 Key Applications: Small data centers; remote sites

Single line of racks Complete and integrated data center infrastructure 3-6 racks (up to 20kW) Integrated Cooling Airflow Management Fire Suppression UPS Power Distribution Monitoring

SmartRow TM Airflow Management

SmartRow TM Benefits Efficient Significant energy savings from enclosed precision cooling system, variable capacity and intelligent controls Optimizes space efficiency through integrated system Economical Room neutral: No effect on existing space Reduce cost of installation: no need to undertake expensive upgrades to fire suppression, cooling capacity or flooring Interoperable Can be deployed in just weeks: simple in design & deployment Local data center experts and service teams for configuration, installation, maintenance, repair Control Monitors temperature and controls precision cooling operating levels accordingly Monitors equipment for quicker response & resolution

SmartRow TM Design & Cost Example Situation: deploy 18 kw of IT to a non-it ready room Conventional Design 18 kw, 288 sq ft 1 rows, 6 racks Ceiling mounted ducted cooling (6) 5 kva UPS Room renovation, fire suppression SmartRow 18 kw, 288 sq ft 1 row, 6 racks 1 Liebert Challenger 6 Liebert GXT 5 kva Room neutral

SmartRow TM Cost Comparison Room Costs contractor, installation, engineering services Infrastructure Equipment UPS, distribution, cooling, racks, fire suppression Annual Energy Consumption power & cooling equipment energy use Conventional SmartRow Cost Savings % Savings $60,000 $43,000 $17,000 28% $105,000 $109,000 -$4,000-3% Total CapEx $165,000 $152,000 $13,000 8% $8,800 $6,400 $2,400 27% 5 Year OpEx $44,000 $32,000 $12,000 27% 5 Year TCO $209,000 $184,000 $25,000 12% Room Savings Equipment Savings Energy Savings Room neutral, fewer services to retrofit room into an IT space Pre-engineered, integrated precision cooling, ducting, distribution and fire suppression Airflow management, variable capacity, intelligent controls

Intelligent, integrated infrastructure using row-based building blocks Applications Capacity: Most cost effective up to 400kW Floor: Raised, non-raised Applications: Small and medium data centers; high-density zones Needs Addressed Efficiency: OPEX & CAPEX Flexibility Availability Standardization Interoperability

Mission: Continue to Connect to Everything Regardless of Vendor Leveraging Avocent firmware expertise

Trellis Universal Management Gateway Universal Management Gateway Provides KVM and Serial Access Integrated or stand-alone Connects directly to Service Processors Supports Environmental Sensors Collects data from connected devices and feeds data to the Trellis software Digital Rack Interface Pod Provides Digital KVM access Powered directly from server Backup power provided by Universal Management Gateway Based on Avocent ASIC technology

Trellis Platform 1.0 Facilities Capabilities Site Management Alarm/event management and notifications Device operating status and data trends Environment and site conditions Energy Management Data center efficiency metrics including PUE Energy consumption (kw/hours) and costs Sub-system efficiency losses Power Systems Management Dependencies of the complete power system Power system resource utilization and capacity Active power path status Cooling Systems Management Dependencies of the complete cooling system Cooling system resource utilization and capacity Cooling target zone management

Capabilities Will Be Bundled Into Value-Driven Offerings EMERSON NETWORK POWER S DATA CENTER INFRASTRUCTURE MANAGEMENT SOLUTION OFFERINGS NOTIONAL OFFERINGS TO BE OFFERED

Customer Benefits Availability Efficiency & Cost Capacity Planning & Agility Compliance Predict outage risks Monitor facilities / IT dependencies Automate impact analyses Reduce MTTR Eliminate risk with root cause analyses Identify redundancy gaps Minimize energy Identify energy inefficiencies Understand IT services TCO Optimize resource utilization Improve process efficiency Centralize IT equipment access Understand data center asset inventory Plan future IT services Optimize IT resource deployment Model deployment scenarios Reduce vendors Control / log IT systems access Control physical access to data center Meet government / industry energy efficiency standards Simplify complex eco-system management

SmartAisle at the DVL Efficiency Lab 115 Sinclair Road Bristol, PA 19007

SmartAisle at Microsoft Technology Center 45 Liberty Blvd. Malvern, PA 19355

Key Takeaways 1. Pressures on data centers will continue to accelerate. 2. Address your data center as a System. 3. Implement DCIM to make informed decisions 4. Improve efficiency across the entire operation 5. Evaluate SmartSolutions 24

Questions?? 115 Sinclair Road Bristol, PA 19007 www.dvlnet.com (215) 785-5950