MPC / 6. First interface. distance up to 15m, speed up to 19,2Kbit/s, GSM modem support. 4 band 850/900/1800/1900 MHz

Similar documents
MPC / 7. First interface. distance up to 15m, speed up to 19,2Kbit/s. 4 band 850/900/1800/1900 MHz. Second interface (galvanically isolated)

MX-1 GSM/GPRS M-BUS DATA LOGGER USER MANUAL

CONTROLLER MPC-330 USER S MANUAL

RAY-3 DATA LOGGER USER S MANUAL

Description (common to all MPC controllers)* Connection and communication functions 2 / 5

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

Reliable and Remote-Manageable for Large Scale M2M Deployment

Z-GPRS2-SEAL THE SIMPLEST REMOTE MANAGEMENT SYSTEM FOR UNIVERSAL APPLICATIONS GSM/GPRS DATALOGGER WITH BUILT-IN I/O S AND TELECONTROL FUNCTIONS

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

Neon pr. ph/ ORP measurement. Applications. Description

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

Touch the future of IoT

5600 Series. 8 and 16-port Serial Device Servers. Features. Internet Readiness for up to 16 Serial Devices

DATA SHEET LAN Server For Energy and Power meters AEM and APM with Modbus interface

Ursalink UR71 Industrial Cellular Router Datasheet

PLC PFC200 Controller PFC200 CS 2ETH RS

ProtoConvert Modbus RTU / Modbus TCP/IP / BACnet MSTP / BACnet IP / SNMP - Telnet (Lighting Controller) PG

Reliable and Remote-Manageable for Large Scale M2M Deployment

SecurityHawk SecurityHawk 8-20

Reliable and Remote-manageable For Large Scale M2M Deployment

Ursalink UR55 Industrial Cellular Router Datasheet

Reliable and Remote-Manageable for Large Scale M2M Deployment

Ursalink UR51 Industrial Cellular Router Datasheet

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision

Communication Interface

The securityprobe5es-x20 s software motion detection and a rich notification suite keeps you up to date 24 hours a day. securityprobe5es-x20

GenIP : Intelligent gateway dedicated to most critical industrial applications

WISE-52xx Intelligent IIoT Concentrator

Intelligent 4 Port RS-422/485 to 2 Port Ethernet Serial Device Server with PoE

Networks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks

Arm-based palm-sized industrial computers with 2 serial ports and 2 LAN ports. Features and Benefits. Certifications

RTU32S RTU32S Series Small Compact Utility RTU

Standard protocol support (e.g. MODBUS, SNMP, M-Bus), possibility to install dedicated user protocols

icex-cmtm General specs and Installation guide

RTU32S RTU32S Series Small Compact Utility RTU

Three-phase electricity meter with instantaneous reading of electrical variables. Input current measurement: 5 A, 90 A, 150 A, 250 A (span by model).

mark150s mark150/485s DDC controllers Summary

UCM 94/1 3G/GPRS Modem for RTU32 Series

CONTROLLER MPC-374 USER S MANUAL

USER S MANUAL TP1043 series

MESR321. Vlinx Isolated Industrial Modbus Ethernet to Serial Gateway B&B ELECTRONICS PRODUCT INFORMATION

MESR Port Industrial Modbus Gateway. Specifications Power. MESR424_r000_2913ds

IPM-S500 Series MID SINGLE PHASE AND THREE-PHASE ENERGY COUNTERS

iologik E4200 Modular Active Ethernet I/O adaptor IT and Instrumentation for industry Introduction Specifications LAN Regulatory Approvals Warranty

SenNet Registered trademark of Satel Spain Dataloggers series DL170 DL171 DL172.

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

S SENECA. Installation Manual Z-TWS4. Z-PC Line. Web Multifunction Controller Straton / Linux

Versions. Q.station Q.station T. Q.station D. Q.station DT x x

Features and Benefits. Certifications

Hardware manual. 1. Overview 2. Technical characteristics 3. Connections. ( Portal (../portal/portal.html)

M-Bus Master MultiPort 250D/L

Industrial IEEE b/g/n wireless access point with 2x10/100Base-T(X) Features

Asset Management. Facility Management. Total Solutions. Supply Chain Management. Utilities. Series 4500

IDS-141A/181A. Industrial 4-port/8-port slim type serial to Ethernet device server. Features. Introduction. DS-Tool

WISE I/O Modules Overview P10-1-1

The new Expert Logger 400: Industry 4.0 ready!

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

securityprobe 5E Standard

Ursalink UR52 Industrial Cellular Router Datasheet

IAP-320 series are reliable a/b/g WLAN Access Point with 2 ports LAN. It supports 802.1X and MAC filters for

SH2WEB24. Central unit module. Benefits. Description

Smart Energy & Power Quality Solutions. ProData datalogger. Datalogger and Gateway

SB2WEB24. SB2WEB BACnet Controller. Benefits. Description

Compatible with all of the AKCP range of Intelligent Sensors it provides a complete environmental, access control and security monitoring solution.

Sensor Control... Access Control... securityprobe 5E-X20

ZLJ\YP[`7YVIL, :[HUKHYK

An all-in-one module. Archiving Up to 50,000 data items time-and-date stamped and saved to flash memory

Features. :. Introduction. :. Leader 5000 Appearance. Ethernet-Based Block I/O System

Features and Benefits. SNMP MIB-II for network management. Certifications

Q Series - Q.station 101 Test Controller

SA2WEB24. Central unit module. Benefits. Description

Part Numbers SNAP-UP1-M64

Wireless Solutions. 5.1 Wireless LAN & Wireless Modem. Wireless Modems. Intelligent GPRS/GSM Modules. Mini-Programmable Automation Controllers

iologik 2500 HSPA/GPRS/WLAN Series

ModBerryM500 series. Features of new. ModBerryM500 ASK FOR NEW RASPBERRY PI 3 B+

MM-IM. Large works automation And data gateway. PRODUCT DATASHEET

iopac 8500 Series Rugged modular RTU controllers Overview Programmable Controllers High Sampling Rate Analog Input Prerecord Feature

M-Bus Master. Data sheet. MultiPort 250D/L

NPort 5400 Series. 4-port RS-232/422/485 serial device servers. Network-Readiness for up to Four Serial Devices

NPort 5400 Series. 4-port RS-232/422/485 serial device servers. Network-Readiness for up to Four Serial Devices

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

Reliable and Remote-manageable For Large Scale M2M Deployment

USER S MANUAL TP series

MGate 5105-MB-EIP Series

ZLAN5200. User Manual

TK C -25 C 95% RH EMC TK701G TK701U TK704G TK704U TK704W. TK-Series Cellular Router

Standard protocol support (e.g. MODBUS, SNMP, M-Bus), possibility to install dedicated user protocols

Standard protocol support (e.g. MODBUS, SNMP, M-Bus), possibility to install dedicated user protocols

3G/4G LTE Cellular to Ethernet and Serial Secure Industrial Gateway. SE5901B Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

Standard protocol support (e.g. MODBUS, SNMP, M-Bus), possibility to install dedicated user protocols

iopac 8020 Series Rugged modular RTU controllers Overview Programmable RTU Controllers Ethernet bypass feature for seamless data transmission

UniMod Intelligent Communication for all Metering Application

Features and Benefits. User-friendly LCD panel for easy installation Adjustable termination and pull high/low resistors.

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

Mega_Link Telemetry Communication System

Feature and Benefits. Certifications

Part Numbers SNAP-PAC-S1 SNAP-PAC-S2

UA Series IIoT Communication Server

Features and Benefits. Certifications

Address. Supply 24 V 0 V Fieldbus connection RJ-45. Fieldbus connection RJ-45. Configuration and programming interface. Pack. System Data.

Transcription:

V.Bartkeviciaus company "VALSENA" Savanoriu ave. 271-412 Kaunas LT 50131, Lithuania Phone: 370 37 310603 Fax: 370 37 310648 E-mail: valsena@valsena.lt MPC-330 Main features: Freely chosen interfaces: up to 5 interfaces. Suppoerted interfaces: RS485,, Data/Req (Kamstrup), Mbus, Current loop, GSM/GPRS and LAN. Supported protocols: Modbus RTU, Modbus TCP/IP, IP, ICMP, UDP, TCP, DHCP, PPP, ARP, SNTP, IEC60870-5-104:200 and transparent, DynDNS, DNS(client), FTP(server&client). Routing: GSM - Ethernet rounting Special: transparent non-standart protocol data transfer Memory expansion: up to 8GB using micros SD card Power: 9-36 VDC (10VA) Power for external devices: 3,7; 5; 6; 8 or 10 VDC (20mA) First interface GSM/GPRS distance up to 15m, speed up to 19,2Kbit/s, GSM modem support 4 band 850/900/1800/1900 MHz Second interface (galvanically isolated) RS485 Opto MBus distance up to 1,2km, max 32 transivers, speed up to 19.2 Kbits/s distance up to 15m, speed up to 19,2Kbit/s (Kamstrup) data transfer interface up to 8 devices 2 wire active Current Loop 25-27V, 14-20mA, up to 6km, speed up to 19,2Kbit/s Third interface (galvanically isolated) RS485 Opto MBus distance up to 1,2km, max 32 transivers, speed up to 19.2 Kbits/s distance up to 15m, speed up to 19,2Kbit/s (Kamstrup) data transfer interface up to 8 devices 2 wire active Current Loop 25-27V, 14-20mA, up to 6km, speed up to 19,2Kbit/s Power for exteranl devices 3,7/5/6/8/10 V Fourth interface RS485 distance up to 1,2km, max 32 transivers, speed up to 19.2 Kbits/s distance up to 15m, speed up to 19,2Kbit/s Fifth interface Ethernet twisted pair, 10/100 Mbps, distance up to 100m Protocols Modbus RTU Modbus TCP/IP IP 1 / 6

ICMP UDP TCP DHCP PPP ARP SNTP IEC60870-5-104:2000 DynDNS FTP server FTP client DNS client General Power 9-36 VDC Galvanic isolation >1000V Capacity Power for external devices 300mA max 3,7/5/6/8/10 VDC (20mA) Regulatory approvals Electromagnetic compatibility EN 55022:2010 EN 55024:2010 EN 61000-4-2:2009 EN 61000-4-3:2006 EN 61000-4-3:2006/A1:2008 EN 61000-4-3:2006/A2:2010 EN 61000-4-4:2004 EN61000-4-4:2004/A1:2010 EN 61000-4-6:2009 Safety EN 60950-1:2006+A1:2010+A11:2009+A12:2011 Specification CPU SD card support Memory ARM7 micro SD card up to 8GB archive storage 1-8 MB, independant data storage without power about 5 years LED indication Power + Serial ports read/write for each port + GSM/GPRS modem status + Ethernet status + Programing and updating Remote Locally GSM/GPRS, Ethernet (RJ45) USB,, RS485 Physical characteristics Dimmensions Weight Mounting type Safety class 147x128x50 mm 400 g on DIN32 rail IP20 Climate conditions Operating temperature -25..+60 C Storage temperature -40..+60 C Humidity range 5-95%, non-condensing Other fuetures Real time clock + MBus auto setup + 24 months warranty period + MAX number of interfaces (for filter) Number of supported interfaces 5 RS485 + distance up to 1,2km, max 32 transivers, speed up to 19.2 Kbits/s + distance up to 15m, speed up to 19,2Kbit/s Opto + (Kamstrup) data transfer interface MBus + up to 8 devices Current Loop + Active or Pasive, 2 or 4 wire Ethernet + twisted pair, 10/100 Mbps, distance up to 100m 2 / 6

USB (device) + Type B, ver. 2,0 USB (host) - Type A, ver. 2,0 Power for exteranl devices + 3,7/5/6/8/10 V Universal - Jumper switchable GSM/GPRS + 4 band 850/900/1800/1900 MHz OVERVIEW MPC-330 controller is created for data logging and analyzing in a real time. Using GPRS/GSM and/or Ethernet, controller sends saved data and reports to remote users. Controller supports most of protocols and interfaces (, RS485, Data/Req, MBus, Current loop), so it can be used with different brands and models of counters. Our special TRANSPARENT data transfer protocol enables controllers to use with practically any device. Device supports wide range of protocols (and can be extended by our programmers, if you need some special). For data exchange over GPRS/GSM, Ethernet and/or any Serial interfaces, controller uses Modbus TCP/IP, Modbus RTU, IEC60870-5-104:2000, SNTP and other protocols. Our clients GAS, Heat, Watering suppliers, Industry companies in EU, Ukraine, Central Asia. DEFAULT FEATURES Reading data from energy carrier meters; "TRANSPARENT remote data reading from counters (special manufacturers protocols); Independent data log (up to 8MB) with real time stamp; Remote configuration and upgrading possibilities over GPRS/GSM and Ethernet; Wide range of interfaces: GSM/GPRS, Ethernet,, RS485, Data/Req, MBus Current Loop, USB; Galvanically isolated interfaces and power supply; BENEFIT TO THE CLIENT Economy, because controller does a lot of mechanic work, so your professionals can do more important work; Increase efficiency, because the data are sent to a central computer continuously. If connection is lost, data will be safe kept in controllers memory, until connection will be reestablished; Increases security, because the relevant information is rapidly shorten response time; Versatile, because this controller can retrieve data from different manufacturers and even different types of meters; Simplicity, because of intuitive control and optimally assembled LED s it is easy to monitor and maintain equipment; A good partner, because we not only help you customize and will make equipment, but also flexibly adapt controller, if your demands will change. 3 / 6

CUSTOMIZING DEVICE The exceptional feature of this device - a flexible hardware and software configuration, it depends on customer needs, you can choose the desired interface and functionality. Manufacturers code: 4 / 6

5 / 6

Powered by TCPDF (www.tcpdf.org) For routing in complex projects of data collection and processing 6 / 6