Disk Scheduling. Chapter 14 Based on the slides supporting the text and B.Ramamurthy s slides from Spring 2001

Similar documents
Disk Scheduling. Based on the slides supporting the text

Chapter 14: Mass-Storage Systems. Disk Structure

Module 13: Secondary-Storage Structure

Chapter 10: Mass-Storage Systems

Chapter 12: Mass-Storage Systems. Operating System Concepts 8 th Edition,

Chapter 13: Mass-Storage Systems. Disk Scheduling. Disk Scheduling (Cont.) Disk Structure FCFS. Moving-Head Disk Mechanism

Chapter 13: Mass-Storage Systems. Disk Structure

CSE325 Principles of Operating Systems. Mass-Storage Systems. David P. Duggan. April 19, 2011

Chapter 12: Secondary-Storage Structure. Operating System Concepts 8 th Edition,

CS3600 SYSTEMS AND NETWORKS

EIDE, ATA, SATA, USB,

Chapter 14: Mass-Storage Systems

Overview of Mass Storage Structure

Free Space Management

Module 13: Secondary-Storage

V. Mass Storage Systems

File. File System Implementation. Operations. Permissions and Data Layout. Storing and Accessing File Data. Opening a File

Mass-Storage Structure

Chapter 12: Mass-Storage Systems. Operating System Concepts 8 th Edition,

CS420: Operating Systems. Mass Storage Structure

Chapter 10: Mass-Storage Systems

Chapter 10: Mass-Storage Systems. Operating System Concepts 9 th Edition

OPERATING SYSTEMS CS3502 Spring Input/Output System Chapter 9

I/O, Disks, and RAID Yi Shi Fall Xi an Jiaotong University

Chapter 12: Mass-Storage

Tape pictures. CSE 30341: Operating Systems Principles

Disk scheduling Disk reliability Tertiary storage Swap space management Linux swap space management

CHAPTER 12: MASS-STORAGE SYSTEMS (A) By I-Chen Lin Textbook: Operating System Concepts 9th Ed.

OPERATING SYSTEMS CS3502 Spring Input/Output System Chapter 9

Disc Allocation and Disc Arm Scheduling?

CS 471 Operating Systems. Yue Cheng. George Mason University Fall 2017

Che-Wei Chang Department of Computer Science and Information Engineering, Chang Gung University

Chapter 10: Mass-Storage Systems

MASS-STORAGE STRUCTURE

Lecture 9. I/O Management and Disk Scheduling Algorithms

Mass-Storage Structure

File. File System Implementation. File Metadata. File System Implementation. Direct Memory Access Cont. Hardware background: Direct Memory Access

Chapter 14: Mass-Storage Systems

I/O Systems and Storage Devices

Part IV I/O System. Chapter 12: Mass Storage Structure

CS370 Operating Systems

Ricardo Rocha. Department of Computer Science Faculty of Sciences University of Porto

Silberschatz, et al. Topics based on Chapter 13

I/O Device Controllers. I/O Systems. I/O Ports & Memory-Mapped I/O. Direct Memory Access (DMA) Operating Systems 10/20/2010. CSC 256/456 Fall

Chapter 12: Mass-Storage

Chapter 12: Mass-Storage

Chapter 12: Mass-Storage Systems. Operating System Concepts 8 th Edition

Chapter 11: Mass-Storage Systems

Part IV I/O System Chapter 1 2: 12: Mass S torage Storage Structur Structur Fall 2010

Chapter 5: Input Output Management. Slides by: Ms. Shree Jaswal

Operating Systems 2010/2011

Today: Secondary Storage! Typical Disk Parameters!

Operating Systems. No. 9 ศร ณย อ นทโกส ม Sarun Intakosum

UNIT 4 Device Management

Chapter 12: Mass-Storage Systems. Operating System Concepts 9 th Edition

Chapter 11 I/O Management and Disk Scheduling

CS370: System Architecture & Software [Fall 2014] Dept. Of Computer Science, Colorado State University

CSCI-GA Operating Systems. I/O : Disk Scheduling and RAID. Hubertus Franke

Chapter 14 Mass-Storage Structure

Introduction Disks RAID Tertiary storage. Mass Storage. CMSC 420, York College. November 21, 2006

Mass-Storage Systems. Mass-Storage Systems. Disk Attachment. Disk Attachment

CS370 Operating Systems

EI 338: Computer Systems Engineering (Operating Systems & Computer Architecture)

Chapter 10: Mass-Storage Systems. Operating System Concepts 9 th Edition

UNIT-7. Overview of Mass Storage Structure

Mass-Storage Systems

CHAPTER 12 AND 13 - MASS-STORAGE STRUCTURE & I/O- SYSTEMS

Disks and RAID. CS 4410 Operating Systems. [R. Agarwal, L. Alvisi, A. Bracy, E. Sirer, R. Van Renesse]

CS370: Operating Systems [Spring 2017] Dept. Of Computer Science, Colorado State University

Mass-Storage. ICS332 - Fall 2017 Operating Systems. Henri Casanova

Chapter 12: Mass-Storage Systems

CS370: Operating Systems [Fall 2018] Dept. Of Computer Science, Colorado State University

Operating System 1 (ECS-501)

CS370: Operating Systems [Fall 2018] Dept. Of Computer Science, Colorado State University

Mass-Storage. ICS332 Operating Systems

Ricardo Rocha. Department of Computer Science Faculty of Sciences University of Porto

CSE380 - Operating Systems. Communicating with Devices

Chapter 11. I/O Management and Disk Scheduling

Chapter-6. SUBJECT:- Operating System TOPICS:- I/O Management. Created by : - Sanjay Patel

I/O Management and Disk Scheduling. Chapter 11

Input/Output. Chapter 5: I/O Systems. How fast is I/O hardware? Device controllers. Memory-mapped I/O. How is memory-mapped I/O done?

MODULE 4. FILE SYSTEM AND SECONDARY STORAGE

CSE Opera+ng System Principles

CIS Operating Systems I/O Systems & Secondary Storage. Professor Qiang Zeng Spring 2018

CSE 380 Computer Operating Systems

CIS Operating Systems I/O Systems & Secondary Storage. Professor Qiang Zeng Fall 2017

CS370 Operating Systems

Operating Systems. V. Input / Output. Eurecom

Chapter 5 Input/Output

Operating Systems. Designed and Presented by Dr. Ayman Elshenawy Elsefy

VIII. Input/Output Operating Systems Prof. Dr. Marc H. Scholl DBIS U KN Summer Term

I/O Hardwares. Some typical device, network, and data base rates

Operating Systems. Mass-Storage Structure Based on Ch of OS Concepts by SGG

CS 537 Fall 2017 Review Session

STORAGE SYSTEMS. Operating Systems 2015 Spring by Euiseong Seo

I/O 1. Devices and I/O. key concepts device registers, device drivers, program-controlled I/O, DMA, polling, disk drives, disk head scheduling

Chapter 7: Mass-storage structure & I/O systems. Operating System Concepts 8 th Edition,

Disks: Structure and Scheduling

CSE 451: Operating Systems Winter Secondary Storage. Steve Gribble. Secondary storage

Lecture 21 Disk Devices and Timers

Transcription:

Disk Scheduling Chapter 14 Based on the slides supporting the text and B.Ramamurthy s slides from Spring 2001 1

User-Space I/O Software Layers of the I/O system and the main functions of each layer 2

Disks Disk Hardware (1) Disk parameters for the original IBM PC floppy disk and a Western Digital WD 18300 hard disk 3

Disk Structure Disk drives are addressed as large 1-dimensional arrays of logical blocks, where the logical block is the smallest unit of transfer. The 1-dimensional array of logical blocks is mapped into the sectors of the disk sequentially. Sector 0 is the first sector of the first track on the outermost cylinder. Mapping proceeds in order through that track, then the rest of the tracks in that cylinder, and then through the rest of the cylinders from outermost to innermost. 4

Disk Scheduling The operating system is responsible for using hardware efficiently for the disk drives, this means having a fast access time and disk bandwidth. Access time has two major components Seek time is the time for the disk are to move the heads to the cylinder containing the desired sector. Rotational latency is the additional time waiting for the disk to rotate the desired sector to the disk head. Minimize seek time Seek time seek distance Disk bandwidth is the total number of bytes transferred, divided by the total time between the first request for service and the completion of the last transfer. 5

Disk Scheduling (Cont.) Several algorithms exist to schedule the servicing of disk I/O requests. We illustrate them with a request queue (0-199). 98, 183, 37, 122, 14, 124, 65, 67 Head pointer 53 6

FCFS Illustration shows total head movement of 640 cylinders. 7

SSTF Selects the request with the minimum seek time from the current head position. SSTF scheduling is a form of SJF scheduling; may cause starvation of some requests. Illustration shows total head movement of 236 cylinders. 8

SSTF (Cont.) 9

SCAN The disk arm starts at one end of the disk, and moves toward the other end, servicing requests until it gets to the other end of the disk, where the head movement is reversed and servicing continues. Sometimes called the elevator algorithm. Illustration shows total head movement of 208 cylinders. 10

SCAN (Cont.) 11

C-SCAN Provides a more uniform wait time than SCAN. The head moves from one end of the disk to the other. servicing requests as it goes. When it reaches the other end, however, it immediately returns to the beginning of the disk, without servicing any requests on the return trip. Treats the cylinders as a circular list that wraps around from the last cylinder to the first one. 12

C-SCAN (Cont.) 13

Version of C-SCAN C-LOOK Arm only goes as far as the last request in each direction, then reverses direction immediately, without first going all the way to the end of the disk. 14

C-LOOK (Cont.) 15

Selecting a Disk-Scheduling Algorithm SSTF is common and has a natural appeal SCAN and C-SCAN perform better for systems that place a heavy load on the disk. Performance depends on the number and types of requests. Requests for disk service can be influenced by the fileallocation method. The disk-scheduling algorithm should be written as a separate module of the operating system, allowing it to be replaced with a different algorithm if necessary. Either SSTF or LOOK is a reasonable choice for the default algorithm. 16

RAID RAID multiple disk drives provides reliability via redundancy. Redundant Array of Independent Disks (RAID) RAID is arranged into six different levels. Several improvements in disk-use techniques involve the use of multiple disks working cooperatively. Disk striping uses a group of disks as one storage unit. RAID schemes improve performance and improve the reliability of the storage system by storing redundant data. Mirroring or shadowing keeps duplicate of each disk. Block interleaved parity uses much less redundancy. 17

RAID Levels 18

Raid Levels(continued) Raid levels 0 through 2 Backup and parity drives are shaded 19

Raid Levels (continued) Raid levels 3 through 5 Backup and parity drives are shaded 20

Raid Levels 6 and 7 RAID 6:P and Q redundancy RAID 7: heterogeneous disks array 21

Disk Attachment Disks may be attached one of two ways: 1.Host attached via an I/O port 2.Network attached via a network connection 22

Network-Attached Storage(NAS) 23

Storage-Area Network (SAN) 24