DAWN Mini ADAQ TC20 Details

Similar documents
Technical Datasheet #TDAXTC20 Thermocouple Scanner 20 Thermocouple Channels CAN, SAE J1939 with Electronic Assistant P/N: AXTC20 Description:

Applications: Stationary, portable power generator sets Genset control systems

Discrete I/O P/N: AXDIO inputs, 8 relay outputs, SAE J1939 with Electronic Assistant

Discrete I/O 12 Discrete Inputs 8 Relay Outputs CANopen P/N: AXDIO128CO

PRELIMINARY. Preliminary Technical Datasheet #TDAX Discrete I/O P/N: AX inputs, 8 relay outputs, SAE J1939 with Electronic Assistant

Applications: Power generator sets and control systems for industrial engine applications.

TECHNICAL DATASHEET #TDAX I/O

Applications: Industrial Automation, Cranes, Hoists, Utility Vehicles, Off-highway, Ag, and Forestry Equipment

Applications: Industrial Automation, Cranes, Hoists, Utility Vehicles, Off-highway, Ag, and Forestry Equipment

Applications: Industrial Automation, Cranes, Hoists, Utility Vehicles, Off-highway, Ag, and Forestry Equipment

TECHNICAL DATASHEET #TDAX Analog Signal Output CAN Controller (SAE J1939)

P/N: AX Applications: power gen set engine control systems oil and gas equipment automation off-highway machine automation

Accessories: PL-DTM06-12SA-12SB Mating Plug Kit (1 DTM06-12S, DTM06-12SB, 2 W12S, 24 contacts) Electronic Assistant Configuration KIT: AX070502

CONCEPT P/N: AX Concept TECHNICAL DATASHEET #TDAX Analog Input CAN Controller CAN (SAE J1939 or CANopen ) with Electronic Assistant

TECHNICAL DATASHEET #TDAX023240

TECHNICAL DATASHEET #TDAX023300

TECHNICAL DATASHEET #TDAX050000K CAN

P/N: AX Distribute your control functions directly onto the valve.

Ordering Part Numbers: TECHNICAL DATASHEET #TDAX BLDC MOTOR CONTROLLER P/N: AX100260

Analog Input Module. ST-3xxx. User Manual CREVIS Co.,Ltd. Version FnIO S-Series

MasterFlux 48V Cascade BLDC Motor Controller Product Specification 030F0137

Inclination sensors 2-dimensional, measuring range up to ±90

BMXAMI0410 analog input module M340-4 inputs - high speed

TM3TI4 module TM3-4 inputs temperature

Blue ID Communication module RS485 SC44

INDUSTRIAL INCLINOMETER SAE J1939 INTERFACE

TM3TI8T module TM3-8 inputs temperature

TM3AI4 module TM3-4 analog inputs

TM3TM3 module TM3-2 temperature inputs and 1 analog output

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL

Modular pressure transmitters for harsh environments DST P500, DST P507 and DST P550

THM501 PT100 MODBUS TEMPERATURE TRANSMITTER

TM3TI4 module TM3-4 inputs temperature

HelmView Model HV750; HVS750. Installation Manual Section 78

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010

TM241CEC24R controller M IO relay Ethernet CAN master

TM241C40U controller M IO transistor NPN

Isolated, Field Configurable Analog Input 6B11 / 6B11HV FEATURES APPLICATIONS PRODUCT OVERVIEW

TM241C24T controller M IO transistor PNP

RMCN22BD Analog Converter ma - for Zelio Analog

System D I S T R I B U T E U R C O N S E I L D E P U I S vision sensors PRODUCT SPECIFICATIONS AND DRAWINGS

QUINT-PS/ 1AC/24DC/20/CO

Inclination sensors 1-dimensional, measuring range

HelmView Model HV750. Installation Manual Section 78

Device manual Inclination sensor 2 axes. JN2301 from firmware /00 05/2016

TM241C40R controller M IO relay

CAN485. Wall Mounting CAN to RS-485 Interface Converter. Support data conversion between 1 CAN port and 1 RS-485 serial port

TM251MESC controller M251 Ethernet CAN

P3-SCM. General Specifications

General Specifications. P2-08THM Analog Input

Trident and Trident X2 Digital Process and Temperature Panel Meter

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES

STEP-PS/1AC/24DC/2.5. Extract from the online catalog. Order No.: DIN rail power supply of 24 V DC/2.5 A, primary switched, single phase.

TM7NCOM16A CANopen interface block - IP67-16 I/O - M12

HIT/HIX HART Isolator

TM241CE24T controller M IO transistor PNP Ethernet

Military (Airborne, ground-fix, shipboard), Ruggedized, Telecom, Industrial

MAJOR VA Power Inverter

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

In-Sight 7010C/7200C/7400C

TM241CE40R controller M IO relay Ethernet

BL compact multiprotocol fieldbus station for Industrial Ethernet 8 Analog Inputs for Thermocouple Elements BLCEN-8M12LT-4AI-TC-4AI-TC

TM3DI16 module TM3-16 inputs

Priva Blue ID Communication module RS485 SC44

SD328AU68S2 motion control stepper motor drive - SD328 - <= 6.8 A

Temperature/Process Controllers Manual

Simple but elegant look and ease of installation make it ideal for various industrial applications.

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

TECHNICAL PRODUCT DATASHEET

DCT 531. Industrial Pressure Transmitter with RS485 Modbus RTU. Stainless Steel Sensor

TM241CEC24T. Main. 14 (remote I/O architecture) W with max number of I/O expansion module ma fast input. 2.

GFK-2415A March Type of sensor connection

TM241CE24U controller M IO transistor NPN Ethernet

GW-7238D J1939 to Modbus TCP Server / RTU Slave Gateway

SKF Multilog On-line System IMx-8. 24/7 condition monitoring to improve machine reliability

KEPCO SINGLE OUTPUT, 1U SIZE, 100 WATT HOT SWAP PLUG-IN POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, HSF-1UR 100W SERIES

NEW Series SSH Output to 75A, 510 Vac with Diagnostics High Industrial Performance (HIPpak) Solid-State Relays

In addition to fan control, many other hydraulic control applications can be accommodated with this hardware and application-specific software.

TM241CE40R controller M IO relay Ethernet

MGate 4101-MB-PBS Series

TM221M16TG controller M IO transistor PNP spring

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

TM221M32TK controller M IO transistor PNP

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

TM221CE40R controller M IO relay Ethernet

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL

Intrinsically Safe Barriers

TM241CE24T controller M IO transistor PNP Ethernet

TM241CE40T controller M IO transistor PNP Ethernet

TM241CE40R controller M IO relay Ethernet

GW-7228 J1939/Modbus RTU Slave Gateway

GSP750 Series. 750 Watts. AC-DC Power Supplies. Models & Ratings. Input

Analog Output Module. ST-4xxx. User Manual CREVIS Co.,Ltd. Version FnIO S-Series

Priva Blue ID Communication module RS232 SC22

P3-RS Remote Slave Module

iologik 4000 Series Modular remote I/O Introduction iologik E4200 Specifications Remote I/O Slice Form Factor and Flexible I/O Variety

General Specifications. P2-SCM Serial Communications

CompactBlock Guard I/O EtherNet/IP Safety Modules

Transcription:

DAWN Mini ADAQ TC20 Details Technical Specifications Inputs Power Supply Input Supply Current Thermocouple Types Thermocouple Inputs Scan Rate Common Mode Readings Thermal Drift Isolation 12V or 24VDC nominal (9 32 VDC power supply range) 200 ma at 12 V Typical 100 ma at 24 V Typical Reverse polarity protection is provided. Power supply input section protects against transient surges and short circuits and is isolated from thermocouple inputs Up to 20 channels, independently configurable for B, E, J, K, N, R, S or T The device reads mv signals from the supported Thermocouples. B = 0 to 13.82 mv E = -9.835 to 76.373 mv J = -8.095 to 69.553 mv K = -6.458 to 54.886 mv N = -4.345 to 47.513 mv R = -0.226 to 21.101 mv S = -0.236 to 18.693 mv T = -6.258 to 20.872 mv Temperatures are configured to indicate the SAE J1939 SPN to be transmitted by that temperature input. Accuracy: +/- 1 C typical with cold junction compensation at ambient temperature Resolution: 0.001 C 100ms per channel, total sweep time maximum 2.2 seconds Input range +/- 4V maximum Rejection is 100db at 5Vp-p (50-60Hz) 150 ppm/ C of span (maximum) Digital isolation is 500VDC from input to ground. Three way isolation is provided for the CAN line, inputs and power supply SPNs and PGNs The SPN drop list includes all temperature SPNs from the J1939-71 standard published up to January of 2009. If an SPN is not supported by the drop list, the user can select a zero SPN, which then allows them to define the SPN and PGN per the application requirements. One byte parameters have a resolution of 1 C / bit and a range of -40 C to 210 C. Two byte parameters have resolution of 0.03125 C / bit and a range of -273 C to 1735 C (per SAE J1939). Averaging The Parameter Group Number (PGN) that will be used to send a temperature to the J1939 network will be entirely dependent on the Suspect Parameter Number (SPN) that was selected for that channel. In all cases, the PGN is a PDU2 type. Each PGN has a predefined priority and repetition rate associate with it. The average temperature of all the active channels can be broadcasted to the network using the default Engine Average Information PGN, or on a Proprietary B message. Open circuit detection Frozen data detection Over or under temperature detection High temperature shutdown detection TDAXTC20 1

Communication CAN Network Termination RS-232 1 CAN 2.0B port, protocol SAE J1939 Digital isolation is provided for the CAN line. According to the CAN standard, it is necessary to terminate the network with external termination resistors. The resistors are 120 Ohm, 0.25W minimum, metal film or similar type. They should be placed between CAN_H and CAN_L terminals at both ends of the network. 1 RS-232 port is available for debugging purposes. ASCII Text Format, 115200 Baud Rate Data 8 bit, Parity None, Stop 1 bit. Flow Control Xon/Xoff. Short circuit protection to ground. General Specifications Microprocessor Diagnostics MC56F8366,16-bit, 512 kbyte flash program memory Configurable Diagnostic Messaging parameters Diagnostic Log is maintained in non-volatile memory. Each thermocouple channel could be configured to send diagnostic messages to the network if the temperature goes out of range. When sending an Active Diagnostic Trouble Code (DM1) or a Previously Active Diagnostic Trouble Codes (DM2) message, the controller will use the appropriate Diagnostic Trouble Code (DTC). As defined by the standard, this is a combination of the Suspect Parameter Number (SPN), the Failure Mode Indicator (FMI), Occurrence Count (OC) and the SPN Conversion Method (CM). UL and cul Compliance UL508 (April 2010) (FTPM2) Controls for Stationary Engine Driven Assemblies cul C22.2 No. 14-10 (2010) CE Compliance 2004/108/EC (EMC Directive) 2011/65/EU (RoHS Directive) Vibration 8 G for a rail mounted and vibration isolated device The marine type approval process tested to 4.0 G per IEC 60068-2-6, Test Fc. Marine Type Approval Lloyd s Register, DNV, ABS, RINA, GL, BV, CCS, IRS Meets the environmental, EMC and vibration requirements of generator set applications in marine installations. Operating Temperature Range -40 to 85 ºC (-40 to 185 ºF) Storage Temperature Range -50 to 120 ºC (-58 to 248 ºF) Humidity Protected against 95% humidity non-condensing, 30 ºC to 60 ºC IP65, Pollution Degree 3 per UL508 The marine type approval process tested to IP56. Weight 2.2 lbs. (1.00 kg)

Packaging Rugged aluminum housing, stainless steel end plates, neoprene gaskets 145.30 x 149.00 x 73.00 mm (5.72 x 5.86 x 2.87 ) L x W x H Connectors, Deutsch IPD P/N: 1 8-pin DT13-08PA, 1 40-pin DRC13-40PA Can be mounted directly on the power generator set or remotely Suitable for moist, high shock, vibrating and non-hazardous environments Sample Rate vs Number of Channels Hz T Channels 3.333333 0.3 1 2.5 0.4 2 2 0.5 3 1.666667 0.6 4 1.428571 0.7 5 1.25 0.8 6 1.111111 0.9 7 1 1 8 0.909091 1.1 9 0.833333 1.2 10 0.769231 1.3 11 0.714286 1.4 12 0.666667 1.5 13 0.625 1.6 14 0.588235 1.7 15 0.555556 1.8 16 0.526316 1.9 17 0.5 2 18 0.47619 2.1 19 0.454545 2.2 s 20 TDAXTC20 3

Dimensional Drawing Electrical Pin Out Power and CAN

Electrical Pin Out - Thermocouples Type J, K, B, E, N, R, S or T + - Mating Connector Part Number: Deutsch IPD p/n DRC16-40SE-A or DRC18-40SA or DRC16-40S with sockets 0462-201-16141 TDAXTC20 5