ULTIMATE-PRECISION DIGITAL LBB

Similar documents
Dual Channel LVDT/RVDT Readout/Controller

ED-22 Analog Output Series Magnetic Encoder

D-SERIES INCLINOMETER

P-SERIES INCLINOMETER

D-Series Inclinometer

Palpadores inductivos LBB

SGJ Cable Actuated Sensor Industrial CANBus J1939

ETHERNET INTELLIGENT PRESSURE SCANNER

SGH Cable Actuated Sensor Industrial CANOpen

MEAS HTU21D PERIPHERAL MODULE

MS4525DO DESCRIPTION STANDARD RANGE (PSI)

USBDEVELKIT DEVELOPMENT KIT V3

T600 TACHOMETER MultiTasker - a measurement & monitoring instrument with 2 frequency and 1 analog inputs

SR1H Cable Actuated Sensor Industrial CANOpen Output Signal

T200 IDENT PRINTER BUDGET THERMAL TRANSFER PRINTER TECHNICAL DATASHEET

MS4515DO SPECIFICATIONS FEATURES APPLICATIONS

OPERATION MANUAL PML-1000

TSYS01-FAMILY Digital Temperature Sensors

TE3124 PRINTER THERMAL TRANSFER PRINTER TECHNICAL DATASHEET

AEROSPACE, DEFENSE & MARINE /// MC801 FIBER OPTIC CONNECTORS

Application Note TSYS01

Sample board for USB DEVELOPPER KIT

REMOTE INPUT/ OUTPUT TERMINAL SYSTEM (RITS) CONNECTORS

MEAS TEMPERATURE SYSTEM SENSOR (TSYS01) XPLAINED PRO BOARD

MP-2000 Dual Channel LVDT/RVDT Readout/Controller

MEAS OPTIMUS PRESSURE SCANNING SYSTEMS

Serial Port Plug - F2M01SXA Brief Datasheet. Features. Applications. General Description. Provides transparent RS-232 serial cable replacement.

PRINTER ACCESSORIES TECHNICAL DATASHEET UNIVERSAL REEL HOLDER

Automated Tuner System Power Distribution Hub

USB Ranger Fiber Optic USB 2.0 Extender. User Guide

T3224 PRINTER. THERMAL TRANSFER PRINTER (600dpi) TECHNICAL DATASHEET

AMP-LATCH RIBBON CABLE INTERCONNECT SOLUTIONS

DPL/DPN-Series Inclinometer

M5600/U5600 Software Manual Wireless Pressure Transducers (Rev 2.0)

USER MANUAL EAZY-CAL LVC-4000 LVDT Signal Conditioner

EUROCARD CONNECTORS PER DIN AND IEC

OCM5 Splitters and Pass-Through Modules for CSX-3 Cabinets

AN510 Using SPI protocol with pressure sensor modules

Absolute Stand Alone Inclinometer

User Manual. Spectrum Pro

FX1901 OEM Compression Load Cell

USB22 Series INTRODUCTION INSTALLATION GUIDE

Calibration Software PTC04 User Manual

PRINTER ACCESSORIES TECHNICAL DATASHEET UNIVERSAL REEL HOLDER

INDUSTRIAL MINI I/O CONNECTOR

FullAXS CONNECTOR SEALING & CABLE ASSEMBLY

VT992 1U External Power Supply for MTCA Systems, Quad 1200 W

P A /P A Projected Capacitive Touch Solution Datasheet

Xtreme/104. PC/104 Serial Communications. User Manual

UPort TM 200/400 Series Quick Installation Guide

Specification Status: RELEASED

Touch Screen. Bergquist. User s Guide. Set-Up and Use of Bergquist 5-Wire Controller USB, RS-232, & PS/2 TOUCH SCREEN CONTROLLER FEATURES

CAN485. Wall Mounting CAN to RS-485 Interface Converter. Support data conversion between 1 CAN port and 1 RS-485 serial port

Operating Manual. Model 3255A Accelerometer

Data Acquisition Package

Specification Status: Released

MHK5 SERIES PROFINET ABSOLUTE MULTI -TURN ENCODER

Specification Status: RELEASED

FLAT FLEXIBLE CABLE (FFC) CONNECTORS

U7100 Pressure Transducer

FCC Information. RoHS This product is RoHS compliant. SJ/T The following contains information that relates to China.

4515DO DESCRIPTION STANDARD RANGES(IN H20)

TRP-C08 User s Manual

8-Channel Relay Output Board Via I 2 C Protocol. I2C-Relay8

Model SC500. Programmable Single-Channel Transducer Indicator/Conditioner DESCRIPTION FEATURES

Electrical Specifications. Input Input range: Vac Hz, single phase AC. 92% typical at high line 50% load. FCC Subpart J EN55022 Class A

Single-channel Silicon ESD Protection Devices

MODULAR PLUGS, ACCESSORIES AND TOOLING

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS

INTMOD485-LH Protocol Converter

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

Integrated Stepper Drive & Motor

USB 3.0 Spectra

Moxa TCC-100 Series User s Guide

FPS2800B12C4 Fluid Property Sensor Module

PRESS-FIT MACHINES A WIDE RANGE OF PRODUCTION EQUIPMENT FOR COMPLIANT PIN CONNECTOR TECHNOLOGY TE APPLICATION TOOLING /// PRESS-FIT MACHINES

USB Ranger 422 User Guide

Product Specification. tsense VAV. CO 2 -, Temperature- and RH- sensor in a housing with colour touch display

Application Note: 48V-BMS-AN01 General Description 48V-BMS. AN01 General Description. Revision 1.0 / 06/10/15 page 1/15

Sierra 80 Volt Brushless DC Motor Controller Product Specification

OBSOLETE. Isolated, Linearized, Thermocouple Input 3B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

User's Guide. Extech AM A AC Analog Clamp Meter

ACSI ACTUATOR CONTROL SOLUTIONS

InVue BT128 Refractometer

WIEG-EXT Wiegand to RS485 extender module.

OWNERS MANUAL REV. A H-4501 SDI-12 FIBEROPTIC MEDIA CONVERTER D

OCT 17 Rev A

Electrical Specifications. Input Input range Vac Frequency. 90% typical at full load, nominal line. FCC Subpart J EN55022 Class B

Moxa TCC-100 Series Hardware Installation Guide

Agilent Connectivity Hardware for PC-to-Instrument Connections. Data Sheet. with Agilent GPIB and Instrument Control Products

DIGITAL COMPASS-RD DIGITAL COMPASS REFERENCE DESIGN KIT USER' S GUIDE. 1. Kit Contents. 2. Introduction. 3. Quick-Start Guide. 4. General Description

converter Tel: Fax:

PRODIS. PD-ADC Digital Process Meter for analog Sensors. Digital Process Meters. Datasheet

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

B100 Installation Manual

USB Ranger User Guide. Cat 5 USB 2.0 Extender with Remote Power. Powered by

USB-I 2 C 13-Channel Controller. I2C-USB-Relay10. User Manual P/N KA-USB-I2C-10RL

zqsfp+stacked Connector and Cage Assembly

WINTOTAL SOFTWARE. Label/Marker Design Package. Technical Datasheet. TTDS-001 Revision 11 - July 2015

Industrial Isolated Converters

Transcription:

ULTIMATE-PRECISION DIGITAL LBB SPECIFICATIONS High precision, 0.1% of reading or 1μm EMI and ESD protected (CE certified) Spring actuated probes Robust cast aluminum case (electronics) Stackable with T-Connectors for networking T-Connector available separately USB interface available (with COM libraries) Up to 31 devices on USB with external power External power supply available FEATURES High resolution 14-bit digitizing module Built-in digital linearity correction Robust probes with precision linear ball bearing Very easy to setup and use, plug-and-play USB bus or externally powered (both available) USB device name for easy WINDOWS recognition Up to 31 probes on one network (external power) RoHS compliant and CE certified APPLICATIONS Wobble/run-out of rotating parts (i.e. rotors, axles) Free-form measurements (i.e. airfoils, windshields, crankshafts, camshafts) Factory automated inspection systems (i.e. engine pistons, bearings, etc.) Optics Inspection Systems (i.e. mirrors, lenses) SPC data collection Metrology The Ultimate-Precision Digital LBB system consists of DLBB digital probes (or gage heads) daisy chained in a network, using T- Connectors (available separately) with DE-9 connectors. Each DLBB includes a highly repeatable analog AC LVDT (Linear Variable Differential Transformer) probe guided with a precision linear ball bearing, mated to an in-line digital I/O signal conditioning module. The circuitry and firmware feature digital calibration and linearity correction of the digital output position signal with extremely high accuracy. The DLBB probes operate in conjunction with our available USB interface module. Our robust dimensional gaging probes are engineered to provide highly precise and repeatable measurements in various industrial, quality assurance and metrology applications. The system is based on an RS-485 half duplex, multi-drop network providing plug-and-play functionality. The DLBB probes convert their position signal into digital data which is then transmitted by the RS- 485 network using asynchronous transmission (poll/response). The devices support both standard and buffered modes. Our USB 2.0 full speed compliant interface module connects to this network (using a T-Connector) to communicate with and allow data transfer to a computer. When our USB module is plugged into a computer running a WINDOWS operating system, the Device Manager (in the section Universal Serial Bus Controllers ) of the Computer Management Console displays the name Meas-Spec Digital LBB Serial Converter, clearly identifying our DLBB device amongst others. The available DLBB external power supply is capable of supplying 31 DLBB gaging probes (2 Amps). It features an integral T-Connector which is permanently attached to it. This special T-Connector will interrupt the bus power and switch it over to the external power supply, for all Digital LBB gaging probes connected downstream. SENSOR SOLUTIONS ///Ultimate-Precision Digital LBB Rev. 8 1/2016 Page 1

SPECIFICATIONS Parameter Specification Comment Measurement ranges 1, 2, and 5 mm Accuracy 0.1% of reading or 1μm Whichever is greater Repeatability 0.0065% of range or 0.15μm Whichever is greater Calibration temperature 72 ± 7 F [22 ± 4 C] Resolution 14 bits Supply voltage 5.00 ± 0.25 Volts DC Supply current 60mA maximum Operating temperature 32 to 140 F [0 to 60 C] Storage temperature -4 to +158 F [-20 to +70 C] Dry air environment Maximum operating relative humidity 60% Non-condensing Standard and Buffered mode sampling rate 240 readings per second Buffer size 3000 Samples Bus format 8 Bits, 1 Stop, Odd Parity Bus baud rate 187.5KBd Standard & buffered modes Bus protocol Proprietary device addressable Bus interface RS-485 Max number of DLBB probes on USB 4 (on computer USB bus power) Plus USB interface module 31 (on external power) USB powered by computer USB Cable length 2 meters Cable jacket material Polyurethane Housing material, electronics Aluminum, epoxy powder coated Weight (device without T-Connector) 115 grams Weight of T-Connector 50 grams Available separately Weight of USB interface 115 grams Available separately External power supply output current 2 Amps Available separately SENSOR SOLUTIONS ///Ultimate-Precision Digital LBB Rev. 8 1/2016 Page 2

DRAWINGS AND DIMENSIONS DIGITAL LBB GAGING PROBE T-CONNECTOR Ø0.18 [4.5] 2 PLACES SENSOR SOLUTIONS ///Ultimate-Precision Digital LBB Rev. 8 1/2016 Page 3

POWER SUPPLY KIT (3 COMPONENTS) USB INTERFACE MODULE SENSOR SOLUTIONS ///Ultimate-Precision Digital LBB Rev. 8 1/2016 Page 4

ORDERING INFORMATION Description Probe or sleeve dia. Actuation Model Part Number 1mm range probe 8mm Spring DLBB315PA-020 72350009-000 2mm range probe 8mm Spring DLBB315PA-040 72350012-000 5mm range probe 8mm Spring DLBB315PA-100 72350015-000 USB interface module for DLBB DLBB USB INTERFACE 72290002-000 T-Connector for DLBB DLBB T-CON 72290003-000 Power supply kit for DLBB (100-240VAC, 50/60Hz input; 5VDC, 2A out) DLBB USB POWER SUPPLY 72290004-000 NORTH AMERICA Measurement Specialties, Inc., a TE Connectivity Company 1000 Lucas Way Hampton, VA 23666 United States Phone: +1-800-745-8008 Fax: +1-757-766-4297 Email: sales@meas-spec.com EUROPE MEAS Deutschland GmbH (Europe) a TE Connectivity Company Hauert 13 D-44227 Dortmund Germany Phone: +49-(0)231-9740-0 Fax: +49-(0)231-9740-20 Email: info.de@meas-spec.com ASIA Measurement Specialties (China), Ltd., a TE Connectivity Company No. 26 Langshan Road Shenzhen High-Tech Park (North) Nanshan District, Shenzhen 518057 China Phone: +86-755-33305088 Fax: +86-755-33305099 Email: info.cn@meas-spec.com TE.com/sensorsolutions Measurement Specialties, Inc., a TE Connectivity company. Accustar, American Sensor Technologies, AST, ATEXIS, DEUTSCH, IdentiCal, TruBlue, KPSI, Krystal Bond, Microfused, UltraStable, Measurement Specialties, MEAS, Schaevitz, TE Connectivity, TE, and the TE connectivity (logo) are trademarks of the TE Connectivity Ltd. family of companies. Other logos, product and company names mentioned herein may be trademarks of their respective owners. The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, TE Connectivity makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity s obligations shall only be as set forth in TE Connectivity s Standard Terms and Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse of the product. Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application. 2015 TE Connectivity Ltd. family of companies All Rights Reserved. SENSOR SOLUTIONS ///Ultimate-Precision Digital LBB Rev. 8 1/2016 Page 5

DISTRIBUTOR / DISTRIBUIDOR Brazil and South America / Brasil e América do Sul Metrolog Controles de Medição Address / Endereço: Rua Sete de Setembro, 2656 13560-181 - São Carlos - SP Brazil / Brasil Phone / Telefone: +55 (16) 3371-0112 +55 (16) 3372-7800 Internet: www.metrolog.net metrolog@metrolog.net www.metrolog.net TE CONNECTIVITY /// SENSOR SOLUTIONS