IBM System Storage DS4700 Express Storage Subsystem Fibre Channel Cabling Guide

Similar documents
IBM TotalStorage DS4500 Fibre Channel Storage Subsystem Cabling Guide

System Storage DS3950 Quick Start Guide

GB of cache memory per controller to DS4800 controllers with 8 GB of cache memory per controller.

IBM TotalStorage DS4000 Fibre Channel and Serial ATA Intermix Premium Feature. Installation Overview

EXN4000 Storage Expansion Unit Installation and Setup Instructions

E-Series Hardware Cabling Guide

E-Series Hardware Cabling Guide

System Storage EXP3000 Rack Installation Instructions

Dell PowerVault MD3600f and MD3620f Storage Arrays. Deployment Guide

Rack Installation Instructions

N3240 Installation and Setup Instructions

Rack Installation Instructions

Hard Drive and Storage Expansion Enclosure Installation and Migration Guide

Rack Installation Instructions

N3220 Installation and Setup Instructions

Rack Installation Instructions

IBM TotalStorage DS300 and DS400 Quick Installation Guide

IBM. Rack Installation Instructions

System i and System p. Service provider information Reference information

IBM System Storage DCS3700 with Gen2 Controllers. Installation, User's, and Maintenance Guide IBM GA

IBM System Storage DS3000 series Interoperability Matrix IBM System Storage DS3000 series Interoperability Matrix

IBM System Storage DCS3860 Quick Start Guide

Power Systems. IBM Power 595 (9119-FHA) removal and replacement procedures

LSI CTS2600 Controller-Drive Tray

IBM System Storage DCS Series with Gen2 controllers. Hard Disk Drive and Storage Enclosure Installation and Migration Guide IBM GA

N3150 Installation and Setup Instructions

IBM System Storage DS3000 series Interoperability Matrix IBM System Storage DS3000 series Interoperability Matrix

Dell EMC PowerVault MD3860f Series Storage Arrays. Deployment Guide

4-Post and Universal Telco Frame (UTF) Rack Mount Kit Installation Instructions

N6000 Series Filer Installation and Setup Instructions

IBM TotalStorage NAS Gateway 300 Model G27. Quick Start Instructions

Dell PowerVault MD3860f Series Storage Arrays Deployment Guide

IBM ThinkPad USB Portable Diskette Drive. User s Guide

Installation, User s, and Maintenance Guide

Emulex 8Gb Fibre Channel Single-port and Dual-port HBAs for IBM System x IBM System x at-a-glance guide

Completing Your System Installation

SAS Connectivity Card (CIOv) for IBM BladeCenter IBM Redbooks Product Guide

Quick Installation Guide

IBM System Storage DS3000 Interoperability Matrix IBM System Storage DS3000 series Interoperability Matrix

Power Systems and 5877 removal and replacement procedures

Power Systems. System processor assembly

CSM200 Expansion Tray

IBM TotalStorage NAS 200 Model 25T. Quick Start Instructions

EXN3000 Storage Expansion Unit Installation and Setup Instructions

Installation and Support Guide for AIX, HP-UX, Solaris, and Linux on POWER

Hardware Replacement Guide

Installation and Support Guide for Microsoft Windows NT and Windows 2000

The Contents and Structure of this Manual. This document is composed of the following six chapters and three appendices.

Before you begin. Unpack & Prepare. Install Hardware. Connect Drive Trays. Apply Power. Connect Data Hosts. Choose Management Method

Hardware Replacement Guide Types 8099, 8116, 8155, 8156 Types 8157, 8158, 8159, 8160 Types 8215, 9210, 9211

Hardware Replacement Guide Lenovo 3000 J Series. Types 8453, 8454, 8455, 8458, 8459, 8460

IBM Shared Disk Clustering. Hardware Reference

IBM FlashSystem V MTM 9846-AC3, 9848-AC3, 9846-AE2, 9848-AE2, F, F. Quick Start Guide IBM GI

IBM FlashSystem V Quick Start Guide IBM GI

Installation and Support Guide for AIX, HP-UX, Solaris, and Linux on POWER

IBM DS4000 Service Alert Setup Instructions

6540 Controller Tray. Initial Setup Guide. EC E1, First Edition

IBM Flex System EN Gb Scalable Switch. User s Guide

ERserver. Service provider information Service functions

IBM System Storage DS3000 Interoperability Matrix IBM System Storage DS3000 series Interoperability Matrix

1 Getting Started Installing & Configuring

Veritas Appliance Hardware Service Procedure

Installing the Cisco SFS 3504 Server Switch

Installing IBM System Storage Productivity Center

SGI InfiniteStorage 350 Quick Start Guide

System i and System p. Creating a virtual computing environment

Installation and User's Guide

SCSI Hard Disk Drives For IBM PCs. User's Guide OPTIONS. by IBM

IBM TotalStorage DS4500 Fibre Channel Storage Server

IBM TotalStorage SAN Switch M12

IBM. Setup Instructions. RS/ Model B50 SA

Cable Routing Procedures for Dell PowerEdge T710 Systems

ideacentre 610S Quick Start Guide

IBM. Setup Instructions. IBM RS/ Model 260 SA

Before you begin. Unpack & Prepare. Install Hardware. Connect Drive Shelves. Apply Power. Connect Data Hosts. Connect Ethernet Cables

Installation and Support Guide for AIX, HP-UX, and Solaris

apple Service Source Xserve RAID 17 March Apple Computer, Inc. All rights reserved.

IBM PCI Hot Plug Services User Guide

SGI InfiniteStorage 120

2U STORAGE ENCLOSURE QUICK INSTALL GUIDE FS4100, FS4500, SC4100, AND FC4100

Installation Manual. Mounting Instructions Mechanical Mounting. Luminato. Teleste Corporation

IBM System Storage DS5020 Express

apple Service Source Xserve RAID Xserve RAID and Xserve RAID (SFP) Updated: 25 May Apple Computer, Inc. All rights reserved.

IBM ThinkPad 380XD/385XD Setup Guide

E-Series Cabling E-Series Hardware

IBM. Setup Instructions. RS/ P Series SA

Before you begin. Unpack & Prepare. Install Hardware. Connect Hardware. Apply Power. Choose Management Method. Install & Use SANtricity Software

Brocade 20-port 8Gb SAN Switch Modules for BladeCenter

Installation, User s, and Maintenance Guide

StorageGRID Webscale 10.4 Appliance Installation and Maintenance Guide

H4 Series Hardware Replacement Guide

ThinkCentre Hardware Installation and Replacement Guide. Machine Types 6417, 6418, 6449, 6453

Cisco Systems 4 Gb 20-port and 10-port Fibre Channel Switch Modules for BladeCenter

IBM United States Announcement , dated February 13, 2007

IBM. IBM PC Servers. IBM SSA RAID Cluster Adapter. Hardware Maintenance Manual Supplement. October 1997

Section 2 Storage Systems Architecture

SPARCstorage Array Configuration Guide

3 Here is a short overview of the specifications. A link to a data sheet with full specification details is given later in this web based training

Installation and Support Guide for AIX, HP-UX and Solaris

EOS-6000 Series Optical A/B Switch User Manual DC Version

Transcription:

IBM System Storage DS700 Express Storage Subsystem Fibre Channel Cabling Guide Table summarizes the steps required to correctly install, cable, and power on your IBM System Storage DS700 Express Storage Subsystem. Unless otherwise stated, all the following tasks are detailed in the sections referenced in the IBM System Storage DS700 Express Installation, User s, and Maintenance Guide. Review the multilingual IBM Safety Information document and read all safety information in the DS700 Express Installation, User s, and Maintenance Guide before you begin the installation. Attention: Before powering on the DS700 Express Storage Subsystem, it must be populated with at least two Enhanced Disk Drive Modules (E-DDMs). If at least two E-DDMs are not installed in each attached storage expansion enclosure or DS700 Storage Subsystem, when you power on the DS700 Express and its attached storage expansion enclosures, your standard storage partition key might be lost and must be regenerated. In addition, the resulting insufficient load to the enclosure power supplies might cause them to intermittently appear as failed, falsely indicating the power supplies are bad. All E-DDMs in the DS700 Express Storage Subsystem and the connected storage expansion enclosure or enclosures must contain no prior configuration data. Table. Installation Tasks Task Detailed Description Review the DS700 Express installation recommendations and requirements. Fold down and open the sides of the shipping box. Without removing the DS700 Express from box, you can remove the DS700 Express rack mounting rails and hardware from the box. Install the support rails in the rack cabinet. Before removing the DS700 Express from the shipping box, remove the components to lighten the unit. Record the serial number, machine type, model number, and RAID controller MAC addresses for your DS700 Express. Preparing for installation in Chapter "Handling static-sensitive devices" in Chapter Installing the support rails in Chapter Removing the CRUs in Chapter Appendix A, Records Install and secure the DS700 Express chassis in the rack cabinet. Installing the DS700 Express into a rack on the support rails in Chapter Replace the components in the installed DS700 Express chassis. Replacing the components in Chapter 7 Install in the rack cabinet the DS000 storage expansion enclosures that you plan to cable to the DS700 Express. 8 If there is any storage expansion enclosure to be attached to the DS700 Express, use SFP modules and FC cables to cable the DS700 Express to the DS000 storage expansion enclosure. Installation, User s, and Maintenance Guide for your DS000 storage expansion enclosure Connecting storage expansion enclosures to the DS700 Express in Chapter

Table. Installation Tasks (continued) Task Detailed Description 9 (If applicable) After you cable the DS000 storage expansion enclosures, set the enclosure IDs of any storage expansion enclosures in the DS700 Express configuration that require their enclosure IDs to be manually set. Ensure that all enclosures including the DS700 Express Storage Subsystems have a unique drive enclosure ID, including a unique value in the singles digit (x). For example, enclosure IDs for EXP70 storage expansion enclosures must be set manually while enclosure IDs for EXP80 storage expansion enclosures are automatically set by the controller. 0 For out-of-band management: v Cable the DS700 Express Ethernet ports to either the management workstation or to the hosts. v Use the default IP addresses for out-of-band connection, or change the IP addresses by using Dynamic Host Configuration Protocol (DCHP) or Storage Manager client. For in-band management: Cable the DS700 Express host channels to the FC HBAs in either the hosts or the FC switch that connects to the host FC HBAs. Connect the power cables for the DS700 Express and the storage expansion enclosures if needed. For models with DC power supplies, ensure that the appropriate disconnect device is installed between the DC power supply and the DC power source. Power on the attached storage expansion enclosures and the DS700 Express storage subsystem. Review the controller firmware and NVSRAM, drive enclosure firmware, ESM firmware, and Storage Manager software requirements and obtain upgrades if necessary. Install the DS000 Storage Manager 9.9 host software on the management workstation (for out-of-band management) or on the host (for in-band management). Use the DS000 Storage Manager software to verify the configuration. Storage expansion enclosure settings in Chapter Connecting secondary interface cables in Chapter Connecting hosts to the DS700 Express in Chapter Cabling the power supply in Chapter Turning on the storage subsystem in Chapter "Software and hardware compatibility and upgrades" in Chapter IBM DS000 Storage Manager Version 9 Installation and Support Guide for your operating system Review and perform the DS000 Health Check process. Performing the DS000 Health Check process in Chapter The following illustrations and instructions provide a very brief overview of the cabling tasks required after you install the DS700 Express in a rack cabinet. Review the following sections and then follow the instructions provided in the IBM System Storage DS700 Express Installation, User s, and Maintenance Guide. Figure. DS700 Express controller ports for models 70 and 7

Table. DS700 Express controller ports for models 70 and 7 Number Description Controller A Controller B Host ports and on Controller A - Model 70 Host ports and on Controller B - Model 70 Host ports,, and on Controller A - Model 7 Host ports,, and on Controller B - Model 7 Serial port Ethernet ports and on Controller A Ethernet ports and on Controller B Drive Channel - Ports and on Controller A Drive Channel - Ports and on Controller B Note: A drive channel consists of two fibre channel ports. Use one drive channel from each controller to create a redundant drive channel loop. See the System Storage DS700 Express Installation, User s, and Maintenance Guide for more details. Installing Small Form-Factor Pluggable (SFP) modules and fibre channel cables Statement : DANGER: Some laser products contain an embedded Class A or Class B laser diode. Note the following: Laser radiation when open. Do not stare into the beam, do not view directly with optical instruments, and avoid direct exposure to the beam. All host and drive cabling connections require you to use SFP modules in the DS700 Express host and drive channels used by the cabling connections. The SFP module housing and fibre channel cable have integrated guide keys that prevent you from inserting these devices incorrectly. Insert SFP modules into ports with minimal pressure so that you do not damage either the SFP module or the port. You can insert an SFP module into an active port without affecting the operational loop performance. You must connect the fibre channel cable to the SFP module after you insert the SFP module into the port. Attention: To avoid damage to your fibre-optic cables: v Do not route the cable along a folding cable-management arm. v Route the cable away from places where it can be damaged by other devices in the cabinet. v For devices on slide rails, leave enough slack in the cable so that it does not bend to a diameter of less than 7 mm ( in.) or a radius less than 8 mm (. in.) when extended or become pinched when retracted. v Do not use plastic cable ties in place of the provided cable straps. v Do not put excess weight on the cable at the connection point. Be sure that the cable is well supported. To install an SFP module and fibre channel cable:

. Remove the protective caps from the SFP module and from the fibre channel cable. Do not touch the exposed fibre-optic cable.. Insert the SFP module into a DS700 Express controller port.. Connect the fibre channel cable to the SFP module. Protective cap Wire tab Protective cap Plastic tab Fibre Channel cable Protective caps 0 o 90 o SFP module SFP module Figure. Connecting fibre channel cable to the SFP module Redundant drive-side fibre channel cabling Attention: Review the cabling information in Chapter of the IBM System Storage DS700 Express Installation, User s, and Maintenance Guide. Pay attention to the "Connecting storage expansion enclosures to the DS700" and "DS700 Storage Subsystem and supported storage expansion enclosure drive cabling schemes" sections. Failure to observe the recommended storage expansion enclosure cabling topology and limitations might result in non-optimal drive channels. Ensure that each storage expansion enclosure and the DS700 Express Storage Subsystem has a unique enclosure ID, including a unique value in the singles digit. The IBM System Storage DS700 Express Installation, User s, and Maintenance Guide describes the importance of redundant cabling and provides redundant cabling diagrams for connecting DS000 storage expansion enclosures to your DS700 Express. Refer to Connecting storage expansion enclosures to the DS700 Express, which provides diagrams of recommended topologies for enclosures. Figure on page shows the recommended redundant cabling topology for attaching a single DS000 EXP70 storage expansion enclosure to the DS700 Express storage subsystem. The topology shown uses ports from drive channels (on controller A) and (on controller B) to achieve a redundant connection to the DS000 enclosure. (In the graphic, represents the IN port and represents the OUT port).

ds700 Figure. Redundant drive-side fibre channel cabling topology for the DS700 and EXP70 Figure shows the recommended redundant cabling topology for attaching a single DS000 EXP80 storage expansion enclosure to the DS700 Express storage subsystem. The topology shown uses ports from drive channels (on controller A) and (on controller B) to achieve a redundant connection to the DS000 enclosure. (In the graphic, represents the EXP80 port labeled B.) ds700 Figure. Redundant drive-side fibre channel cabling topology for the DS700 and EXP80 DS000 storage expansion enclosure support The DS700 Express supports a maximum of drives in one redundant drive channel pair. The DS700 Express storage subsystem enables you to mix certain storage expansion enclosure models in the same configuration. In some cases, to intermix storage expansion enclosure models you must meet additional requirements, such as firmware updates or grouping restrictions. You might also need to purchase additional premium features. Refer to the IBM System Storage DS000 Hard Drive and Storage Expansion Enclosure Installation and Migration Guide and the IBM System Storage DS700 Express Storage Subsystem

ds7008 Installation, User's and Maintenance Guide for complete information on enclosure support and intermixing requirements for the DS700 Express storage subsystem. Redundant host-side fibre channel cabling The DS700 Express supports direct-attached redundant connections to up to four hosts. To ensure full protection against the loss of any one fibre channel path from the host servers to the DS700 Express storage subsystem, always use redundant host connections by connecting each host to the appropriate single-ported host channels on both RAID controllers A and B.. To connect the first host server to the DS700 Express storage subsystem, connect one host server FC host adapter to host channel of controller A (top), and connect the other host server FC host adapter to host channel of controller B (bottom).. To connect additional redundant hosts, connect the two host server FC host adapters to the next host channels on each controller (A and B), as shown in the following figure. Host, Host Adapter and Host, Host Adapter and Host, Host Adapter and Host, Host Adapter and Figure. Redundant host-side fibre channel cabling topology Note: Instead of connecting to a fibre channel host bus adapter, you can also connect to fibre channel switch ports.

This page left intentionally blank. 7

Trademarks IBM, the IBM Logo, and System Storage are trademarks of International Business Machines Corporation in the United States, other countries, or both. Note to U.S. Government Users - Documentation related to restricted rights - Use, duplication or disclosure is subject to restrictions set forth in GSA ASP Schedule Contract with IBM Corp. Third edition (March 007) Copyright International Business Machines Corporation 00, 007. All rights reserved. US Government Users Restricted Rights Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp. GC-78-0 (P) P/N: W88