User Guide. Westermo Teleindustri AB Lynx DSS. WeOS. Industrial Ethernet Device Server Switch.

Similar documents
User Guide. Westermo Teleindustri AB Lynx L110 / L210. WeOS. Industrial Ethernet 10-port Switch.

Lynx. Industrial Ethernet 10-port Switch L110 / L210. User Guide

Viper port Ethernet M12 switch. User Guide Westermo Teleindustri AB. X1 X5 X9 X6 X10 X7 X11 SRV 1 X2 X8 X12 DC X4

User Guide. Westermo Teleindustri AB Lynx DSS L105-S1/L205-S1. WeOS. Industrial Ethernet 5-port Device Server Switch.

User Guide. Westermo Teleindustri AB Lynx DSS L106-S2/L206-S2. WeOS. Industrial Ethernet 6-port Device Server Switch.

User Guide. Westermo Teleindustri AB Lynx DSS L108 / L208-F2G-S2. WeOS. Industrial Ethernet 8-port Device Server Switch.

User Guide. Westermo Teleindustri AB Lynx L110 / L210. WeOS. Industrial Ethernet 10-port Switch.

User Guide. Westermo Teleindustri AB RV-07B. 19 rack system PS-20 Power card.

User Guide. Westermo Teleindustri AB 2004 REV.A SDW Industrial Ethernet 5-port Switch.

User Guide. Westermo Teleindustri AB TD-29 DC. FSK-modem Multidrop 2-wire.

User Guide Westermo Teleindustri AB SDW-500. Industrial Ethernet 5-port Switch.

User Guide. Westermo Teleindustri AB RedFox. Ethernet switch and router approved for railway usage.

Wolverine DDW DDW Industrial Ethernet Extender WeOS

User Guide. Westermo Teleindustri AB DDW-226 WOLVERINE SERIES. WeOS. Industrial Ethernet SHDSL extender.

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MANUEL D INSTALLATION RD-48 LV/HV. RS-422/485 Repeater Répéteur RS-422/485

User Guide. Westermo Teleindustri AB RedFox Industrial. WeOS. Industrial Routing Switch.

User Guide. Westermo Teleindustri AB DDW-100. Industrial Ethernet SHDSL Extender.

Legacy Serial. Legacy Serial Redundant Ring Ethernet Extender DDW-222. High Speed Ethernet extension over copper. Configuration and diagnostics

ODW-621 Fibre Optic Modem

800xA Networks. NE801 User Manual. Power and productivity for a better worldtm

User Guide Westermo Teleindustri AB. Lynx SERIES. Industrial Ethernet 8-port Switch.

RedFox Industrial Series

User Guide. Westermo Teleindustri AB MCW-211. Industrial Ethernet Media Converter.

ODW-622 Fibre Optic Modem

DDW-002-B1. EN Ethernet Broadband Bridge. User Guide Westermo Teleindustri AB. 10/100 BASE-TX LINK DC1 X1 X1 DC2

User Guide Westermo Teleindustri AB. Lynx SERIES. Industrial Ethernet 8-port Switch.

AD-01 M-BUS Adapter. Industrial adapter, M-bus, Repeater, Converter and zone controller.

User Guide Westermo Teleindustri AB DDW-100. Industrial Ethernet SHDSL Extender.

User Guide. Westermo Teleindustri AB DDW-220 WOLVERINE SERIES DDW-220. Industrial Ethernet SHDSL extender.

MCW-211-F1G-T1G. Industrial Ethernet Media Converter.

User Guide. Westermo Teleindustri AB DDW-120. Industrial Ethernet SHDSL Extender.

Viper-12A. 12 port Ethernet M12 switch. User Guide Westermo Teleindustri AB. ON USB X2 X3 RSTP FRNT CON V ON USB

User Guide. Westermo Teleindustri AB RedFox Industrial. WeOS. Industrial Routing Switch.

Industrial Routing Switch

User Guide. Westermo Teleindustri AB DDW-220. Wolverine series DDW-220. Industrial Ethernet SHDSL extender.

Ethernet Extender with serial support DDW-226

Viper 20A Series. 20 port Ethernet M12 switches. User Guide REV. C. Westermo Teleindustri AB. X9 X15 X16 X17 X10 X11

Industrial Routing Switch

User Guide. Westermo Teleindustri AB 2006 EDW Serial Adapter.

RedFox Industrial Rack Series

SMM Series 3G and GSM Modems. Quick Start Guide. Document Number: Version: 1.2 (20 October, 2015)

ODW-641. Industrial Converter PROFIBUS DP to Fibre Optic Link. Point to Point applications. Fibre Optic Modem. User Guide

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

User Guide Westermo Teleindustri AB TDW-33. DIN-rail Tele V.90 modem.

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

User Guide. Westermo Teleindustri AB BRD-355. Industrial ADSL/VDSL Router.

FL MC 2000E (SM40) LC

MC 11 EB-2 Power supply cabinet with external bus, AC version

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

Multi-Power Miniature Media Converter 10/100/1000 JUNE 2007 LGC322A-NPS LGC320A-NPS, LGC321A-NPS,

MRD-350. Industrial Mobile Broadband Router GSM / GPRS / EDGE / 3G / HSDPA / HSUPA / HSPA. User Guide

AS1008-P AS1026-P AS2008-P AS2024-P User Manual

Industrial Serial RS-232 to Fiber Converter. KSC-200 Series. Installation Guide

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

Industry Line. Ethernet Solutions for Building Automation Systems and CCTV Surveillance Applications

10/100TX to 100FX w/ 1 PoE Injector Industrial Media Converter User Manual

Lantech IPGC-0101DSFP. User Manual. 10/100/1000T (PoE at) to 100/1000M SFP Industrial Switch Converter

FCC Information. RoHS This product is RoHS compliant. SJ/T The following contains information that relates to China.

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink

Documentation on all Paxton products can be found on our web site -

Modbus TCP/RTU Gateway

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input.

Lantech. IPGS-0204DSFP 4 10/100/1000T PoE at/af + 2 Dual Speed SFP Industrial Unmanaged Switch

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

Hypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :

ICPDAS FSM-510G Series Ethernet Management Switch Quick Start

User Guide Westermo Teleindustri AB EDW-100. Serial Adapter.

6 10/100/1000TX + 2G Fiber Industrial Ethernet Switch User Manual

RS-232/422/485 to Copper or Fiber. Ethernet Converter. User s Manual

LNX-0702G-SFP Series

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Redundancy unit CP-A RU

Perle SMI Media Converter Installation Guide

MINI-PS AC/10-15DC/8

Industrial 3-Port Fast Ethernet Media Converter Switches

LS8000 USER MANUAL. Kitchen Display Station Controller. with Android TM

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

EasySync Ltd. ES-R-2x01-M RS232 to RS422 / RS485 Converter. User Guide. Document Reference No.: ES_ Version draft Issue Date:

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Manual Version: V1.00. Video Decoder Quick Guide

MF BASE-T to 1000BASE-X INDUSTRIAL MEDIA CONVERTER WITH SFP SUPPORT INSTALLATION GUIDE

Leased-Line Extenders over IP

Gigabit Miniature Media Converters. Connect Gigabit Ethernet copper ports to fiber optic cable.

8~14-Port Managed Ethernet Switch

Device Server for the conversion of serial interfaces (RS-232/422/485) to IP.

LNP series. 5-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 1*10/100Tx, 12~36VDC Input.

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

TN-5308 Quick Installation Guide

Fig. 1: Entry Line Compact Gigabit Ethernet Converter

SOHO Access TM Module. User Guide. SAM-SW5U: 5-port 10/100 Ethernet Switch

LNX-1002C-SFP Series

PoE Powered Gigabit Ethernet Media Converters 1000BASE-T TO 1000BASE-SX/LX. KGC-352 Series. Installation Guide

Transcription:

User Guide 6643-2220 WeOS Lynx DSS Westermo Teleindustri AB Industrial Ethernet Device Server Switch www.westermo.com

License Information This device contains public available software which is under the GPL license. For more information see legal.pdf included with all firmware releases. This product includes software developed by the OpenSSL Project for use in the OpenSSL Toolkit. http://www.openssl.org Legal information The contents of this document are provided as is. Except as required by applicable law, no warranties of any kind, either express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, are made in relation to the accuracy and reliability or contents of this document. Westermo reserves the right to revise this document or withdraw it at any time without prior notice. Under no circumstances shall Westermo be responsible for any loss of data or income or any special, incidental, and consequential or indirect damages howsoever caused. More information about Westermo can be found at the following Internet address: http://www.westermo.com 2 6643-2220

Safety! Before installation: Read this manual completely and gather all information on the unit. Make sure that you understand it fully. Check that your application does not exceed the safe operating specifications for this unit. This unit should only be installed by qualified personnel. This unit should be built-in to an apparatus cabinet, or similar, where access is restricted to service personnel only. The power supply wiring must be sufficiently fused, and if necessary it must be possible to disconnect manually from the power supply. Ensure compliance to national installation regulations. This unit uses convection cooling. To avoid obstructing the airflow around the unit, follow the spacing recommendations (see Cooling section)..!! Before mounting, using or removing this unit: Prevent access to hazardous voltage by disconnecting the unit from power supply. Warning! Do not open connected unit. Hazardous voltage may occur within this unit when connected to power supply. Class 1 Laser Product Do not look directly into the optical fibre port or any connected fibre patch cables although this unit is designed to meet the Class 1 Laser regulations. Care recommendations Follow the care recommendations below to maintain full operation of unit and to fulfil the warranty obligations. This unit must not be operating with removed covers or lids. Do not attempt to disassemble the unit. There are no user serviceable parts inside. Do not drop, knock or shake the unit, rough handling above the specification may cause damage to internal circuit boards. Do not use harsh chemicals, cleaning solvents or strong detergents to clean the unit. Do not paint the unit. Paint can clog the unit and prevent proper operation. Do not expose the unit to any kind of liquids (rain, beverages, etc). The unit is not waterproof. Keep the unit within the specified humidity levels. Do not use or store the unit in dusty, dirty areas, connectors as well as other mechanical part may be damaged. If the unit is not working properly, contact the place of purchase, nearest Westermo distributor office or Westermo Tech support. Fibre connectors are supplied with plugs to avoid contamination inside the optical port. As long as no optical fibre is mounted on the connector, e.g. for storage, service or transportation, should the plug be applied. WARNING: When this unit is operated at an ambient temperature above +50 C, the External Surface of Equipment may exceed Touch Temperature Limit according to EN/IEC/UL 60950-1. To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord. 6643-2220 3

Fibre Optic Handling Fibre optic equipment needs special treatment. It is very sensitive to dust and dirt. If the fibre will be disconnected from the unit the protective hood on the transmitter/receiver must be connected. The protective hood must be kept on during transportation. The fibre optic cable must also be handled the same way. Cleaning of the optical connectors In the event of contamination, the optical connectors should be cleaned by the use of forced nitrogen and some kind of cleaning stick. Recommended cleaning fluids: Methyl-, ethyl-, isopropyl- or isobutyl-alcohol, Hexane, Naphtha. Maintenance No maintenance is required, as long as the unit is used as intended within the specified conditions. Agency approvals and standards compliance Type EMC Safety Approval / Compliance EN 61000-6-1, Immunity residential environments EN 61000-6-2, Immunity industrial environments EN 61000-6-3, Emission residential environments EN 61000-6-4, Emission industrial environments EN 55022 +A1, Emission IT equipment EN 55024 +A1 + A2, Immunity IT equipment FCC part 15 Class B EN 50121-4, Railway signalling and telecommunications apparatus IEC 62236-4, Railway signalling and telecommunications apparatus UL/IEC/EN 60950-1, IT equipment Marine DNV Standard for Certification no. 2.4 FCC Part 15.105 Notice: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio/tv technician for help. 4 6643-2220

Declaration of Conformity Westermo Teleindustri AB Declaration of conformity The manufacturer Westermo Teleindustri AB SE-640 40 Stora Sundby, Sweden Herewith declares that the product(s) Type of product Model 1 Ethernet device server switch Lynx DSS L*08-F2G-S2* is in conformity with the following EC directive(s). No Short name 2004/108/EC Electromagnetic Compatibility (EMC) References of standards applied for this EC declaration of conformity. No Title Issue EN 61000-6-1 Electromagnetic compatibility Immunity for residential 2007 environments EN 61000-6-2 Electromagnetic compatibility Immunity for industrial 2005 environments EN 61000-6-3 Electromagnetic compatibility Emission for residential 2007 environments EN 61000-6-4 Electromagnetic compatibility Emission for industrial 2007 environments EN 55022 Information technology equipment Radio disturbance characteristics Limits and methods of measurement 2006 +A1:2007 EN 55024 Information technology equipment Immunity characteristics Limits and methods of measurement EN 50121-4 Railway applications Electromagnetic compatibility Emission and immunity of the signalling and telecommunications apparatus The last two digits of the year in which the CE marking was affixed: 11 1998 + A1:2001 + A2:2003 2006 Pierre Öberg Technical Manager 25 th May 2011 1 The first * in the model name can be any alphanumeric character, indicating software version. The second * in the model name can be any alphanumeric characters indicating customer specific models, or blank. Org.nr/ Postadress/Postal address Tel. Telefax Postgiro Bankgiro Corp. identity number Registered office S-640 40 Stora Sundby 016-428000 016-428001 52 72 79-4 5671-5550 556361-2604 Eskilstuna Sweden Int+46 16428000 Int+46 16428001 6643-2220 5

Type tests and environmental conditions Environmental phenomena Basic standard Description Test levels Electrostatic discharge EN 61000-4-2 Enclosure Contact: ±6 kv Air: ±8 kv Fast transients EN 61000-4-4 Power port ±2 kv Ethernet Status out/digital in Serial ports Enclosure Surge EN 61000-4-5 Power port L-L: ±0.5 kv, 2 Ω, 18 μf L-E: ±2 kv, 42 Ω, 0.5 μf L-L: ±1 kv, 42 Ω, 0.5 μf L-E: ±2 kv, 12 Ω, 9 μf L-L: ±1 kv, 12 Ω, 9 μf Ethernet L-E: ±2 kv, 2Ω, 0.5 μf Status out/digital in L-E: ±2 kv, 42 Ω, 0.5 μf L-L: ±1 kv, 42 Ω, 0.5 μf RS-232 L-E: ±2 kv, 2 Ω, 0.5 μf RS-422/485 L-E: ±2 kv, 42 Ω, 0.5 μf Power frequency magnetic field EN 61000-4-8 Enclosure 300 A/m; 0, 16.7, 60 Hz 1000 A/m; 50 Hz Pulsed magnetic field EN 61000-4-9 Enclosure 300 A/m Radiated RF immunity EN 61000-4-3 Enclosure 20 V/m @ (80 2700) MHz 1 khz sine, 80% AM Conducted RF immunity EN 61000-4-6 Power port 10 V, 80% AM, 1 khz; (0.15 80) MHz Ethernet Status out/digital in Serial ports Earth port Radiated RF emission EN 55022/ FCC Part 15/ DNV 2.4 Enclosure Class B / DNV bridge Conducted RF emission EN 55022/ FCC Part 15/ DNV 2.4 Power port Ethernet Class B / DNV bridge Class B Compass safe distance DNV 2.4 Enclosure Standard compass (5.4 /H deviation) = 15 cm Steering/standby steering/emergency compass (18 /H deviation) = 10 cm Dielectric strength EN 60950-1 Power port to all 1.5 kvrms, 50 Hz, 1 min other ports Ethernet ports to all other ports RS-232 port to all other ports RS-422/485 port to all other ports 6 6643-2220

Environmental Temperatures Operating 40 to +70 C* Storage and transport 50 to +85 C Humidity Operating 5 to 95 % relative humidity Storage and transport 5 to 95 % relative humidity Altitude Operating 2 000 m / 70 kpa MTBF MIL-C217F2, Ground Benign, 25 C 499 000 hours Parts count Service life Operating 10 year Vibration IEC 60068-2-6 (sine) Operating 3 13.2 Hz: 1mm 13.2 100 Hz: 0.7 g 5.5 30 Hz: 1.5 g 30 50 Hz: 0.42 mm 50 500 Hz: 4.2 g** IEC 60068-2-64 5 20 Hz: 2 m²/s³, (random) 20 2000 Hz: 3 db/oct Shock IEC 60068-2-27 Operating 30 g, 11 ms 100 g, 6 ms** Bump IEC 60068-2-27 Operating 10 g, 11 ms Packaging Enclosure EN 60950-1 Zinc Fire enclosure Dimension W x H x D With connectors 52.5 x 100 x 101 mm 52.5 x 119 x 101 mm Weight 0.7 kg Degree of protection EN 60529 Enclosure IP 40 Cooling Convection * Refer to Safety section in User Guide. ** Might require Ethernet cables to be fastened close to the unit. 6643-2220 7

Description Lynx DSS is an Industrial switch and device server made for harsh environments. WeOS is the operating system of Lynx DSS enabling the unit to operate in two functional levels. The switch can be used in ether 100 Mbit or Gigabit networks due to our multi-rate SFP solution. Lynx DSS has two serial ports, one that supports RS-232 and the other configurable for RS-232/422/485 as well as serial protocols for interconnection with legacy equipment. Our unique FRNT (Fast Recovery of Network Topology) technology is the fastest protocol on the market to re-configure a network in the event of any link or hardware failure. That is why Lynx is used in safety critical applications such as tunnels, traffic signal control and railway systems. Installations in harsh environments and places with heavy electrical interference require the use of a reliable media, therefore a number of fiber optic transceiver are available as accessories to Lynx DSS. 8 6643-2220

Interface specifications Power Operating voltage Rated current Rated frequency Inrush current, I 2 t Startup current* Polarity Redundant power input Isolation to Connection Rated: 24 to 48 VDC Operating: 19 to 60 VDC 250 ma (380 ma) @ 24 VDC (with 500 ma USB load) 120 ma (188 ma) @ 48 VDC (with 500 ma USB load) DC 22.7 10-3 A 2 s @ 48 VDC 2 x Rated current Reverse polarity protected Yes All other Detachable screw terminal Connector size 0.2 2.5 mm 2 (AWG 24 12) Shielded cable Not required * External supply current capability for proper start-up Ethernet TX Electrical specification Data rate Duplex Circuit type Transmission range Isolation to Connection Cabling Conductive housing Number of ports 4 * Refer to Safety section. IEEE std 802.3. 2005 Edition 10 Mbit/s, 100 Mbit/s, manual or auto Full or half, manual or auto TNV-1 Up to 150 m with CAT5e cable or better* All other RJ-45, auto MDI/MDI-X Shielded CAT5e or better is recommended Yes Ethernet SFP pluggable connections (FX or TX) Electrical specification Data rate Duplex Transmission range Connection Number of ports 1 or 2 IEEE std 802.3. 2005 Edition 100 Mbit/s or 1000 Mbit/s transceivers supported Full or Auto, depending on transceiver Depending on tranceiver SFP slot holding fibre transceiver or copper transceiver 6643-2220 9

RS-232 Electrical specification Data rate Data format Protocol Circuit type Transmission range Isolation to Connection Shielded cable Conductive housing Number of ports 1 RS-232/422/485 Electrical specification EIA RS-232 300 bit/s 115.2 kbit/s 7 or 8 data bits, Odd, even or none parity, 1 or 2 stop bits Transparent, optimised by packing algorithm SELV 15 m / 49 ft All other RJ-45 according to EIA-561 Recommended Yes Data rate RS-232 50 bit/s 115.2 kbit/s Data format Circuit type RS-422/485 Configurable for EIA RS-232 or EIA RS-422/485 50 bit/s 2 Mbit/s 7 or 8 data bits, Odd, even or none parity, 1 or 2 stop bits (2 stop bits only when no parity is set) TNV-1 Transmission range RS-232 15 m / 49 ft Isolation to RS-422/485 Up to 1200 m / 0.74 mi, depending on data rate and cable type All other Connection RS-232 RJ-45 according to EIA-561 RS-422/485 RJ-45 Shielded cable RS-232 Recommended Conductive housing RS-422/485 Number of ports 1 Not required, but recommended in railway installations close to the rails.* Yes * To minimise the risk of interference, a shielded cable is recommended when the cable is located inside 3 m boundary or the cable is longer than 30 m and inside 10 m boundary to the rails and connected to this port. I/O / Relay output Maximum voltage/current Contact resistance Isolation to Connection 60 VDC / 80 ma Max 30 Ω All other Detachable screw terminal Connector size 0.2 2.5 mm 2 (AWG 24 12) 10 6643-2220

I/O / Digital input Maximum voltage/load current 60 VDC / 2 ma Voltage levels Logic one: >12V Logic zero: <1V Isolation to Connection All other Detachable screw terminal Connector size 0.2 2.5 mm 2 (AWG 24 12) USB Electrical specification Data rate Circuit type Maximum supply current Connection USB 2.0 host interface Up to 12 Mbit/s (full-speed mode) SELV 500 ma USB receptacle connector type A Console Electrical specification LVTTL/LVCMOS-level Data rate 115.2 kbit/s Data format 8 data bits, no parity, 1 stop bit, no flow control Circuit type SELV Connection 2.5 mm jack, use only Westermo cable 1211-2027 Accessories Description Art no Westermo console cable 1211-2027 RJ45 to terminal block 1200-2490 RJ45 to DB9 cable 1211-2210 SFP Transceivers Supported transceivers See SFP Transceivers User Guide 6100-0000 for recommended SFP transceivers. For UL60950-1 compliance, only the UL recognized SFP transceivers listed in 6100-0000 should be used. Deviations With copper transceiver 1100-0148 the specified operating temperature on Lynx DSS is 0 to +50ºC. FRNT reconfiguration times can not be guaranteed with copper transceivers. 6643-2220 11

Location of interface ports and LED s LED Indicators (for details see page 16) Power connection (for details see page 9) USB Position Direction Description No. 1 Out VBUS No. 2 In/Out D No. 3 In/Out D+ No. 4 Out GND Shield In/Out Connected to protective earth SFP transceivers (for details see page 9 and 11) Ethernet connection TX (4 ports) I/O connection (for details see page 10) Position Signal Direction Description No.1 TD+ In/Out Transmitted/Received data No. 2 TD In/Out Transmitted/Received data No. 3 RD+ In/Out Transmitted/Received data No. 4 Not Connected No. 5 Not Connected No. 6 RD In/Out Transmitted/Received data No. 7 Not Connected No. 8 Not Connected Shield Connected to PE RJ-45 connector (Front view) Male Female Pin 8 Pin 1 Pin 8 Pin 1 Pin 1 Pin 8 12 6643-2220

RS-422/485 (for more details see below) Position Signal Direction Description RS-232 RS-422 (4-wire) RS-485 (2-wire) No. 1 T+ T+/R+ Out/In RS-422: Transmit RS-485: Transmit/Receive No. 2 T T /R Out/In RS-422: Transmit RS-485: Transmit/Receive No. 3 R In RS-422: Receive No. 4 Not used No. 5 Not used No. 6 R+ In RS-422: Receive No. 7 Not used No. 8 Not used Position Signal Direction Description No. 1 DSR Out Data Set Ready No. 2 DCD Out Data Carrier Detect No. 3 DTR In Data Terminal Ready No. 4 SG Signal Ground, not chassis ground No. 5 RD Out Receive Data No. 6 TD In Transmit Data No. 7 CTS Out Clear To Send No. 8 RTS In Request To Send Lynx DSS is equipped with internal termination that is configurable through software in RS-422/485 mode. The following termination schemes are supported: No termination Terminate Rx Terminate Tx Terminate Tx and Rx RS-422 Tx Tx Tx Tx Rx Rx Rx Rx No termination Termination RS-485 When the unit is powered-off or during reboot, any internal termination will be disconnected from the signal lines. Note: Due to that the port is configurable for both RS-232 and RS-422/485, there are no fail-safe biasing available for RS-422/485 signals. 6643-2220 13

I/O connection (for details see page 10) Console port (for details see page 10) Cable 1211-2027 Bottom view Connection to console port The console port can be used to connect to the CLI (Command Line Interface). The following steps needs to be taken 1. Connect the serial diagnostic cable to the console port (use only Westermo cable 1211-2027). 2. Connect cable to your computer (USB port, if drivers are needed they can be downloaded from our Web page). 3. Use a terminal emulator and connect with correct speed and format (115200, 8N1) to the assigned port. For more information about the CLI, see the WeOS management guide. Accessories Description Art no Westermo console cable 1211-2027 RJ45 to terminal block 1200-2490 RJ45 to DB9 cable 1211-2210 14 6643-2220

Power connection 4-position Product marking Direction Description 1 2 3 4 No. 1 +DC1 Input Supply voltage input DC1 No. 2 +DC2 Input Supply voltage input DC2 No. 3 -COM Input Common No. 4 -COM Input Common LynxDSS supports redundant power connection. The positive inputs are +DC1 and +DC2, the negative input for both supplies are COM. Connect the primary voltage (e.g. +24 VDC) to the +DC1 pin and return to one of the COM pins on the power input. I/O connection 4-position Product marking Direction Description 1 2 3 4 No. 1 Status + Output Alarm relay (status) contact No. 2 Status Output Alarm relay (status) contact No. 3 Digital in + Input Digital in + No. 4 Digital in Input Digital in The Status output is a potential free, opto-isolated normally closed solid-state relay. This can be configured to monitor various alarm events within the Lynx DSS unit, see WeOS Management Guide. An external load in series with an external voltage source is required for proper functionality. For voltage/current ratings, see Interface Specification section. The Digital in is an opto-isolated digital input which can be used to monitor external events. For voltage/current ratings, see Interface Specification section: Lynx DSS 1 External Load 2 V Status 3 4 + V Digital In 6643-2220 15

LED indicators LED Status Description ON OFF Unit has no power. GREEN RED BLINK All OK, no alarm condition. DC1 OFF Unit has no power. GREEN RED Alarm condition, or until unit has started up. (Alarm conditions are configurable, see ''WeOS Management Guide''). Location indicator ("Here I am!"). Activated when connected to IPConfig Tool, or upon request from Web or CLI. Power OK on DC1. Power failure on +DC1. DC2 OFF Unit has no power. GREEN RED Power OK on DC2. Power failure on +DC2. FRNT OFF FRNT disabled. GREEN RED BLINK FRNT OK. FRNT Error. RSTP OFF RSTP disabled. GREEN BLINK Unit configured as FRNT Focal Point. RSTP enabled. VPN* OFF VPN disabled. GREEN RED Unit elected as RSTP/STP root switch. (Configurable) Default: At least one VPN tunnel up and OK. (Configurable) Default: All VPN tunnels down. Rx/TD, TD OFF No serial data received. GREEN FLASH Serial data received. Tx/RD, RD OFF No serial data transmitted. GREEN FLASH 1 to 6 OFF No Link. GREEN GREEN FLASH YELLOW Serial data transmitted. Link established. Data traffic indication. * VPN functionality only available in Lynx DSS 208. Port alarm and no link. Or if FRNT or RSTP mode, port is blocked. 16 6643-2220

Mounting This unit should be mounted on 35 mm DIN-rail, which is horizontally mounted inside an apparatus cabinet or similar. Snap on mounting, see figure. Mounting Lynx with integrated DIN-clip: Removal Removing Lynx with integrated DIN-clip: Press down the support at the back of the unit using a screwdriver. See figure. Cooling This unit uses convection cooling. To avoid obstructing the airflow around the unit, use the following spacing rules. Minimum spacing 25 mm (1.0 inch) above / below and 10 mm (0.4 inches) left / right the unit. Spacing is recommended for the use of unit in full operating temperature range and service life. 10mm 10mm 6643-2220 17

Getting Started This product runs Westermo Operating System (WeOS) which provides several management tools that can be used for configuration of the unit. IPConfig tool This is a custom Westermo tool used for discovery of attached Westermo units. Note! Version of IP Config tool must be 10.4.0 or higher. Web Configuration of the unit using the web browser. CLI Configuration of the unit via the Command Line Interface. Username: admin Password: westermo If the computer is located in the same subnet as the switch you can easily use a web browser to configure the unit. Within the web you can configure most of the available functions. For advanced network settings and more diagnostic information, please use the CLI. Detailed documentation is available in the chapter The Command Line Management Tool in the WeOS management guide. Factory default IP address: 192.168.2.200 Netmask: 255.255.255.0 Gateway: Disabled Note! If you are not sure about the subnet consult your network administrator. Configuration Configure the unit via Webbrowser The unit can easily be configured via a Web browser. Open the link http://192.168.2.200 in your web browser, and you will be prompted with a Login screen, where the default settings for Username and Password are: Username: admin Password: westermo Once you have logged in, you can use the extensive integrated help function describing all configuration options. Two common task when configuring a new switch is to assign appropriate IP settings, and to change the password of the admin account. The password can be up to 64 characters long, and should consist of printable ASCII characters (ASCII 33-126); 'Space' is not a valid password character. 18 6643-2220

Referring documents Type Description Document number Management Guide Westermo OS management guide 6101-3201 Factory default on Lynx DSS It is possible to set the unit to factory default settings by using two straight standard Ethernet RJ-45 cables. 1. Power off the switch and disconnect all Ethernet cables (copper and fibre). 2. Connect one Ethernet cable between Ethernet ports 3 and 6, and the other between Ethernet ports 4 and 5. The ports need to be connected directly by an Ethernet cable, i.e., not via a hub or switch. Use a straight cable not a cross-over cable when connecting the ports. 3. Power on the unit. 4. Wait for the unit to start up. Control that the ON LED is flashing red. The ON LED flashing indicates that the unit is now ready to be reset to factory default. You now have the choice to go ahead with the factory reset, or to skip factory reset and boot as normal. Go ahead with factory reset: Acknowledge that you wish to conduct the factory reset by unplugging the Ethernet cables. The ON LED will stop flashing. This initiates the factory reset process*, and after approximately 1 minute the unit will restart with factory default settings. When the switch has booted up, the ON LED will show a green light, and is now ready to use. Skip the factory reset: To skip the factory reset process, just wait for approximately 30 seconds (after the ON LED starts flashing RED) without unplugging the Ethernet cables. The switch will conduct a normal boot with the existing settings. * Note Do not power off the unit while the factory reset process is in progress. 6643-2220 19

Westermo Teleindustri AB SE-640 40 Stora Sundby, Sweden Phone +46 16 42 80 00 Fax +46 16 42 80 01 E-mail: info@westermo.com Westermo Web site: www.westermo.com Sales Units Sweden Westermo Data Communications AB Svalgången 1 SE-724 81 Västerås Phone: +46 (0)21 548 08 00 Fax: +46 (0)21 35 18 50 E-Mail: info.sverige@westermo.se United Kingdom Westermo Data Communications Ltd Talisman Business Centre Duncan Road Park Gate, Southampton SO31 7GA Phone: +44(0)1489 580 585 Fax.:+44(0)1489 580586 E-Mail: sales@westermo.co.uk Germany Westermo Data Communications GmbH Goethestraße 67, 68753 Waghäusel Tel.: +49(0)7254-95400-0 Fax.:+49(0)7254-95400-9 E-Mail: info@westermo.de France Westermo Data Communications S.A.R.L. 9 Chemin de Chilly 91160 CHAMPLAN Tél : +33 1 69 10 21 00 Fax : +33 1 69 10 21 01 E-mail : infos@westermo.fr Singapore Westermo Data Communications Pte Ltd 2 Soon Wing Road #08-05 Soon Wing Industrial Building Singapore 347893 Phone +65 6743 9801 Fax +65 6745 0670 E-Mail: sales@westermo.com.sg North America Westermo Data Communications 939 N. Plum Grove Road, Suite F Schaumburg Chicago Phone: +1 847 619 6068 Fax: +1 847 619 66 74 E-mail: info@westermo.com Taiwan Westermo Data Communications Co F2, No. 188, Pao-Chiao Rd. Shing-Tien City Taipei 23145 Phone:+886 2 8911 1710 E-mail: info@westermo.com Westermo Teleindustri AB have distributors in several countries, contact us for further information. REV.C 6643-2220 2012-01 Westermo Teleindustri AB, Sweden A Beijer Electronics Group Company