Table of Contents. Automatic Transfer Switch. User Manual ATS-16A/20A/30A/32A

Similar documents
ALPHA Automated Transfer Switch Operating Manual. Rev 1.21 The original of this document is drawn up in English language

User Guide Automatic Transfer Switch (ATS)

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA. GE Critical Power

Installation and Operation

Zonit μats TM Users Guide μats1-lv Version 1.2

Neutrik 20A powercon with 2nd order EMI filter & GDT/VDR protection circuit against Lightning Strike & Local Power Surge Circuit A

Metered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord

User Manual Back-UPS Pro BN 1100/1350/1375/1400/1500 M2 BN 1100/1350/1500 M2-CA

F1000 User's Manual. (Version: V1.01)

iconverter 2-Module Power Chassis

U P S USER S MANUAL IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. Uninterruptible Power System. Line Interactive (Network) UPS

User Manual Back-UPS BE650MC

TOUCH SCREEN CONTROLLER for Air Conditioning Control System

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

W-715 Fog Jet USER MANUAL English 2013 Antari Lighting and Effects Ltd.

MIL-STD Rugged Computer User's Manual. Version 1.0 Revision Date: July. 05, 2017 THOR200. MIL-STD Rugged Computer

Line Interactive 1000VA/1400VA/2000VA Uninterruptible Power System

Party Dimmer IEC ORDERCODE 50324

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR065-48S / OPR065-48R. Manual

GRID-TIED SOLAR INVERTER 1.5KW ~ 6.0KW V.1.2

Installation and Operation Back-UPS Pro 900

Installation Manual INTELLIGENT SERVER. Model name: BMS-LSV6UL

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

Mounting and Operating Instructions (Simple Programming) Art.No..: , published: 10/2003

User Manual. Solar Inverter for Water Pump

Installation and Operation Back-UPS Pro 900

Broadband Automatic Disconnect Switch. User Manual

Liebert PST5. Installer/User Guide

UPS Emergency Bed Power Unit

OFFICE UPS MULTI-DEVICE PROTECTION UPS 500S/600S/750S

AX3000 Platine Terminal Ethernet TCP/IP

AX3000 Platine Terminal Ethernet TCP/IP

Digital Overhead Stirrer

The power behind competitiveness. Delta UPS - Amplon Family. N Series, Single Phase 1/ 2/ 3 kva. User Manual.

Model HM-535 Power Supply Installation and Service Instructions

1PH RACK 19 SINGLE PHASE UPS Rev. 11 SR 6kVA 10kVA

Back-UPS RS APC Back-UPS RS 800VA 120V Black

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2

Product Specifications

EATON 5S 850/1200/1600

USER MANUAL AUTOMATIC TRANSFER SYSTEM SPS ATS

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Stage Fog Machine User Manual

OPERATING INSTRUCTIONS PA AMPLIFIER P-1812

Metered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord

Pulsar EXtreme 2000/3000 VA

Liebert PSA5. Installer/User Guide

Power Supply. Users Guide PRODUCT MANUAL. WESTELL.COM Westell Technologies MNL rd

QIT600F1 USER'S GUIDE

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

Z-350 FAZER USER MANUAL

Powerware 3105 UPS User s manual

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Z-380 Fazer Machine User Manual English

Powerware 3105 UPS User s manual

Hardened PoE Ethernet Switch

FT-20 Fire Training Fog Machine User Manual English

INFO-PV_Inverter. User Manual INF-PVI 2000 INF-PVI 3000 INF-PVI 4000 INF-PVI 5000

FT-20 Fire Training Fog Machine User Manual English

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E

T SERIES UPS kva PF Vac with Internal Battery 7.0 Touch Screen. User Guide

Smart Grid Tie Microinverter User Manual

Table of Contents. 3.1 Front/Rear Panel and User Interface Front Panel Rear Panel User Interface...

25.2kW 3-Phase Switched PDU, LX Platform Interface, 240V Outlets (24 C13/6 C19), Touchscreen LCD, IEC A Red 415V, 0U, TAA

Liebert MicroPOD 230V

Wise HP33 THREE PHASE HIGH PRECISION AVR SURVO-MOTOR AUTOMATIC VOLTAGE STABILIZER

Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13

Back-UPS RS 550 Installation & Operation

22-60VDC Grid Tie Microinverter User Manual

Mission 1K-2K-3K INSTRUCTION MANUAL. Single Phase UPS. Uninterruptible Power Systems

Installation and Operation Manual Back-UPS BR900G-RS

Modified Sinewave Series. Power Inverter 1000/1500 MW 1210, MW1215. True Sinewave Power Inverter 1000/2000 SW 1210, SW 1220.

MANUAL ENGLISH PSA-63A4C. Ordercode: Highlite International B.V. Vestastraat EX Kerkrade the Netherlands

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

Metered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R

IES User Manual. 6 GE + 2 SFP Unmanaged Switch -20 to 60C, DIN-rail. v

Premium Online Series

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL

WIRESPEED ADSL MODEM (MODEL 2000) User Guide

High Power over Ethernet Midspans PD Port Model PD Port Model

Optional add-on cassette Attachment Instruction manual

Quick Installation Guide

Liebert PSI5. Installer/User Guide

INTELLIGENT SERVER. Model: BMS-LSV6E

HYBRID PV INVERTERS HySpirit Series. 4kW-10kW. Hybrid Inverter with Battery Backup Smart Energy for Smart Home

Arion PDU : Intelligent Power Distribution User Guide for 24xC13 Outlet Monitored PDU

Disclaimer. Note that the Midspan is designed for indoor use only.

INSTALLATION AND USER MANUAL Green Point T

ALO Duo Roll DMX LED barrel scanner with dual light source

Follow the procedure below for unpacking the carton in which the device is shipped. DW-GTW-AC-E1060 Four anti-slide bumpers for desktop installation

Nature Power Inverters. Modified Sinewave 1000w/1500w True Sinewave 1000w/2000w. Owner s Manual

Itona TC73yy Hardware User s Guide

MAJOR VA Power Inverter

99 Washington Street Melrose, MA Phone Toll Free Visit us at

TABLE OF CONTENTS TABLE OF CONTENTS... 1 IMPORTANT SAFETY NOTICE...

RS Stock No Instruction Manual RS Input Data Logging Thermometer

Transcription:

Table of Contents 1. Important Safety Instructions... 2 2. Overview... 3 3. Product Functional Description... 4 3.1. Front Panel... 4 3.2. LCD Display Description... 5 3.3. Rear Panel... 6 3.4. Communication Interface... 7 4. Installation and Operating Instructions... 9 4.1. Unpacking... 9 4.2. Installation Procedures... 10 4.3. Operating Procedures... 11 5. Troubleshooting... 12 6. System Specifications... 13 7. Appendix A. Customized features to configure dry contacts... 15 Automatic Transfer Switch User Manual ATS-16A/20A/30A/32A 1

1. Important Safety Instructions This document provides important instructions for a safe installation, operation and use of the ATS. 1. Do not disassemble the ATS as there are no serviceable parts inside. Disassembling can cause electric shock and warranty will be void. 2. All repairs and maintenance should only be done by a qualified technician or authorized distributor. 3. This ATS supports electronic equipment in office, telecommunication, process control, medical and security applications. Non-authorized technicians are not allowed to install the ATS in the following areas: a. Life supporting medical equipment. b. Elevators, subway systems or any other equipment related to human safety. c. Public systems critical computer systems. 4. Please discuss with your distributor before installing the product at the locations mentioned above. Special considerations and designs are required for the operation, setup, management, and maintenance of critical equipment and emergency backup power generators related to personal safety and public facilities. 5. This equipment is not water proof. 6. Do not install the ATS in an environment with sparks, smoke, or gas. 7. This ATS is designed to be installed in a sheltered, controlled environment as follow: - Operating temperature 0-40 C, and 30-90% non-condensing humidity; - Avoid locations with dust, corrosive material, salt content, or flammable gas; - Install the ATS indoors as it is not designed for outdoor installation. 8. Improper grounding results in electrical leakage. Please ensure your AC input power is properly grounded. 9. Ensure the input voltage of the ATS matches the utility supply voltage. Use a certified input power cable with the correct plugs and sockets for the appropriate voltage system. 2. Overview The ATS (Automatic Transfer Switch) features two independent power supply source supplying power to the load (as shown in Figure 1 below). In the event of a power failure in the main utility (Source A), the ATS automatically switches to Source B to supply power to the load. The ATS automatically switches back to Source A after power is restored. In addition, the ATS provides user configurable power status (voltage or frequency) for the ATS switching condition. SOURCE A SOURCE B Figure 1. ATS block diagram Load 2 3

3. Product Functional Description 3.1. Front Panel 3.2. LCD Display Description No. Item Description/function 1 Mute button Turn off the sound of the alarm Select source to view info: Input A, Input B, 2 Source selection button or Load 3 Info selection button Select source info to view: Voltage, current, frequency, load capacity 4 Input selection button Switch input source: Input A Input B 5 LCD System status display 6 Input indicator A 7 Input indicator B 8 Error indicator 9 USB port 10 RS-232 port 11 Dry contact port Dry Contact 12 External communication slot Lit: Normal input voltage and frequency Dim: Abnormal input voltage and frequency Flashing: Indicates higher priority Lit: Normal input voltage and frequency Dim: Abnormal input voltage and frequency Flashing: Indicates higher priority Lit: System malfunction or abnormal Dim: System normal Connection for software setup or monitoring software Connection for software setup or monitoring software For external communication cards, e.g. RS-485, SNMP Symbol Description/function Input A error or power failure Input B error or power failure Overload System malfunction or abnormal Alarm on Alarm off Digital display showing input/output power connected to load ATS numeric display 4 5

3.3. Rear Panel Following is a rear view and basic information for each available ATS model. ATS-216 (230V-16A) 3.4. Communication Interface The ATS provides three communication ports and one external communication slot (optional) for the user. Standard communication ports: RS-232, USB, and 5 dry contacts External communication slot: SNMP, RS-485 ATS-120 (120V-20A) ATS- 232 (230V-30A) 3.4.1. RS-232 3.4.2. USB Pin Definition Type Signal 1 N/A N/A N/A 2 TX Output TX 3 RX Input RX 4 N/A N/A N/A 5 GND Power source N/A 6 +12V Power source N/A 7 N/A N/A N/A 8 N/A N/A N/A 9 N/A N/A N/A Pin Signal 1 VBUS ATS- 130(120V-30A) 2 D- 3 D+ 4 GND 3, 1 Power input (B) 5 Output socket 2 Power input (A) 6 Output breaker 4 Input breaker (optional, sold separately) 6 7

3.4.3. Dry Contact The ATS provides five user configurable dry contacts for customized features (Refer to Appendix 1). The capacity of each contact is 24Vdc/1A. Pin Definition Signal (default) 1 Common 3 N/A 2 Relay 3 System Alarm 3 Relay 4 Overload 4 Common N/A 5 Relay 5 Over temperature 6 Common 1 N/A 7 Relay 1 Source A abnormal 8 Common 2 N/A 9 Relay 2 Source B abnormal 4. Installation and Operating Instructions 4.1. Unpacking Upon receiving of goods, inspect the package and contents for shipping damage. Any missing contents, damage or other problem must be reported to the forwarder or dealer as soon as possible. Product Inventory: ATS Module RS-232 cable x1 pcs USB cable x1 pcs CD (Monitoring software and Setting tool) x1 pcs User Manual x1 pcs Backplate and screws x1 set *Power cable x2 pcs *Available for ATS-216 models only. 8 9

4.2. Installation Procedures 1. Affix the two included backplates to the ATS as shown in Figure 1. 2. Mount the ATS into a 19 rack or into a cabinet with 19 inner design as shown on Figure 2. 3. Connect the load power cords to the ATS sockets labelled "OUTPUT" 4. Check that the total load does not exceed ATS specifications (e.g. voltage, current). 5. Turn on all connected equipment. The ATS automatically boots up after 1 second and supply power to the connected load. 4.3. Operating Procedures 4.3.1. Boot Up Once the input power is connected, the ATS automatically boots up and the LCD display and LEDs (,, ) are lit as shown in Figure 3. After boot up, the LCD display the input source voltage as shown in Figure 4 and the selected Input indicator A ( ) LED or Input indicator B ( ) LED is lit. Figure 3 Figure 4 Figure 1 4.3.2. Switch input source The ATS supports manual switching between power supplies as instructed below: Press and hold the Input selection button for 2 seconds until you hear two short beeps. The system display the power transfer (LCD display as shown in Figure 5), press again and hold the Input selection button for 2 seconds to confirm. The system will switch to Source B (LCD display as shown in Figure 6) if the power supply is present. If the power supply is not present and switching fails, the LCD display a warning as shown in Figure 7. Figure 2 Figure 5 Figure 6 Figure 7 10 11

5. Troubleshooting If you are encounter problems with the ATS, refer to the troubleshooting guide below. Should the problem persists, please contact your local dealer for assistance. Issue Possible Cause Solution ATS is OFF Power is supplied to the load but panel remains off Error code Er01, Er02 Error code Er03 to Er15 Not connected to the electrical grid Abnormal electrical grid Input breaker has been tripped Check the connection from the electrical grid to the ATS input Request service by professional electrician Reset breaker Internal components have Please contact the local dealer. been damaged Internal components have Please contact the local dealer been damaged Not connected to the electrical grid Abnormal electrical grid Abnormal power system Check the connection from the electrical grid to the ATS input Request service by professional electrician Request service by professional electrician Error code Er16 Overload Check the load capacity Error code Er17 to Er32 Abnormal internal components Please contact the local dealer 6. System Specifications Model ATS-120 ATS-130 Input Input voltage 100V / 110V / 115V / 120V / 127V (software selectable: +/-5%, 10%, 15%, 20%) Input voltage range 75Vac~150Vac Input frequency 50/60Hz (software selectable: +/- 5%, 10%, 15%, 20%) Input current 20A 30A Output Output voltage 100V / 110V / 115V / 120V / 127V Output current 20A 30A Connection Input NEMA 5-20 x 2 NEMA L5-30 x 2 Output NEMA 5-20 x 8 NEMA 5-20 x 16, NEMA L5-30 x 1 Protection Input Breaker(option) Electronic circuit Communication RS-232, USB, Dry contact external slot for option card (SNMP, RS-485) Transfer time(ms) 6ms typical, 16ms maximum Efficiency 99% (with full linear load) Display LCD+LED Physical Dimension, D X W X H (mm) 275 x 440 x 44 275 x 440 x 88 Net Weight (kgs) 4 6 Environment Operating temperature -5~40 C @ 20~90% RH (non-condensing) Standards Safety UL 60950-1/CAN/CSA C22.2 No. 60950-1 compliance EMC FCC Part 15 12 13

Model ATS-216 ATS-232 Input Input voltage 200V / 208V / 220V / 230V / 240V (software selectable: +/- 5%, 10%, 15%, 20%) Input voltage range 150Vac~300Vac Input frequency 50/60Hz (software selectable: +/- 5%, 10%, 15%, 20%) Input current 16A 32A Output Output voltage 200V / 208V / 220V / 230V / 240V Output current 16A 32A Connection Input IEC-C20 inlets x2 40A terminal 6P output IEC-C13 x 8, IEC-C13 x16, IEC-C19 x 1 IEC-C19 x2 Protection Input Breaker (option) Electronic circuit Communication RS-232, USB, Dry contact external slot for option card (SNMP, RS-485) Transfer time(ms) 6ms typical, 16ms maximum Efficiency 99% (with full linear load) Display LCD+LED Physical Dimension, D X W X H (mm) 275 x 440 x 44 275 x 440 x 88 Net Weight (kgs) 4 6 Environment Operating emperature -5~40 C @ 20~90% RH (non-condensing) Standards Safety UL 60950-1/ CAN/CSA C22.2 No. 60950-1, IEC 60950-1 ompliance EMC FCC Part 15, EN62310-2 7. Appendix A. Customized features to configure dry contacts Event Code 1 Source A no power Er01 2 Source B no power Er02 3 Source A voltage abnormal Er03 4 Source B voltage abnormal Er04 5 Source A frequency abnormal Er05 6 Source B frequency abnormal Er06 7 Source A voltage and frequency abnormal Er07 8 Source B voltage and frequency abnormal Er08 9 ATS no output due to source A and B abnormal Er09 10 Source A voltage unbalance Er10 11 Source B voltage unbalance Er11 12 ATS output voltage unbalance Er12 13 ATS output voltage abnormal Er13 14 ATS output frequency abnormal Er14 15 ATS output voltage and frequency abnormal Er15 16 ATS output overload and cut output Er16 17 ATS output short circuit and cut output Er17 18 Input relay defect on source A Er18 19 Input relay defect on source B Er19 20 Source transfer relay defect Er20 21 ATS output relay defect Er21 22 Internal working power 12V defect on source A Er22 23 Internal working power 12V defect on source B Er23 24 System over temperature Er24 25 System DC offset error Er25 26 EEPROM working abnormal Er26 27 Emergency Power Off Er27 28 Loss LCD connection Er28 29 Internal transferring inhibition by some reason Er29 30 Overload transferring is over 4 times and system lock Er30 31 Inhibit to transferring due to phase angle over shift Er31 32 System Alarm Er32 14 15

16 17

19232 18