NI SMB-2145/2146/2147/2148

Similar documents
You need the following to set up and use your terminal block:

NI 653x Cable Adapter

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9208E 16-Channel, ±20 ma, 24-Bit Analog Input Module

NI 6521 Specifications

NI CB-37F-LP. Introduction INSTALLATION GUIDE. Connector Block for 37-Pin D-Sub Devices

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9870E

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9871E

INSTALLATION INSTRUCTIONS LFH160 Cable

Getting Results with the NI 5752R

Getting Results with the NI PXI-6585R

NI SD Card Memory Module

Getting Started with R Series Multifunction RIO

NI 9213 Calibration Procedure

Getting Started with R Series Intelligent DAQ

Electrical. SPECIFICATIONS SH Cable

TBX-96 TERMINAL BLOCK

Getting Started with the NI PCIe-1433

LabVIEW DSP Module. Contents. Introduction RELEASE NOTES. Version 1.0

NI TB Introduction. Conventions INSTALLATION INSTRUCTIONS Wire Terminal Block for the NI PXI-2529

NI 6584R User Guide and Specifications

Getting Started with the NI 8234

NI USB Introduction USER GUIDE AND SPECIFICATIONS. 4-Channel, ±10 V, 16-Bit Analog Voltage Output Module

Calibrating FieldPoint Analog Input Modules with Calibration Executive

SH Cable Specifications

SCC-AO10 Isolated Analog Output Module

Caution Electrostatic discharge can damage your controller. To avoid such damage, handle the controller only in a proper ESD-controlled environment.

SCC-RLY01 Relay Module

Getting Started with the NI PCIe-8253

SCXI HIGH-VOLTAGE 8 4 MATRIX TERMINAL BLOCK

Getting Started with NI-Motion for NI 73xx Motion Controllers

Getting Started with the NI 8234

NI USB Introduction USER GUIDE AND SPECIFICATIONS. 8-Channel, 24 V Logic, Sinking Digital Input Device

USER GUIDE Universal Motion Interface (UMI)-7764

FieldPoint. FP-1000/1001 FieldPoint Quick Start Guide. Install the Network Module Mount the module on a DIN rail. What You Need to Get Set Up

For NI PXI and NI SCXI Switch Modules

SCXI -1313A Terminal Block

NI CAN Demo Box. NI CAN Demo Box User Guide. Power supply (+9 VDC to +12 VDC) 68-pin Multifunction Data Acquisition board

cfp-rly-421 Features Installing the cfp-rly-421 FieldPoint Operating Instructions Eight-Channel SPST Relay Module

INSTALLATION INSTRUCTIONS NI TB-2630B Terminal Block for the NI PXI-2530B. Contents. Introduction

NI SPEEDY-33. '7 NATIONAL INSTALLATIONGUIDE. P~ClCl J ~ Ig~~!1 "INSTRUMENTSN. 1~~~~~~g~~lm.OOOQ{JOOO,

Getting Started with the NI PCIe-8235

NI Channel, 0 20 ma, 16-Bit Analog Current Output Module

Sample. LabWindows TM /CVI TM Core 1 Exercises Manual

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9476E. 32-Channel, 24 V Sourcing Digital Output Module

LabVIEW DSP Module Release and Upgrade Notes

INSTALLATION INSTRUCTIONS SH160F-160M-NI SwitchBlock Cable

Getting Started with the NI PXI/PCIe-8231

This installation guide describes how to install and connect signals to the NI TBX-2808 screw terminal accessory for use with NI SwitchBlock cards.

FieldPoint cfp-20xx. Quick Start Guide. What You Need to Get Set Up

NI PXI-2567 Specifications

FP-PS-4. Features. Installation

CompactRIO Reconfigurable Embedded Chassis

Compact FieldPoint cfp-cal

The NI TB-2648/2649/2650/2651 terminal blocks configure your NI PXI/PXIe-2531 (NI 2531) in one of the following topologies. 1-wire 8 64 matrix

Getting Started with the NI PCI-1405

Sample. LabWindows TM /CVI TM Core 1 Course Manual

NI 5761R User Guide and Specifications

USER GUIDE SC-2075 SIGNAL CONDITIONING ACCESSORY

NI USB Introduction USER GUIDE AND SPECIFICATIONS. 8-Channel, 24 V Logic, Sourcing Digital Output Device

USER GUIDE I/O Accessory For the NI PCIe-8237R GigE Vision Interface Device

Getting Started with the NI PCI-8254R

NI PCIe-8255R Quick Start Guide

Getting Started with the NI PCIe-8255R

NI What You Need to Get Started. Unpacking INSTALLATION GUIDE. This document explains how to set up your NI 8262 expansion module.

NI USB Introduction USER GUIDE AND SPECIFICATIONS. 4-Channel, 0 20 ma, 16-Bit Analog Current Output Module

8x16, 2-Wire Terminal Block for the NI PXI The following conventions are used in this guide:

CompactRIO NI crio-9012/9014

Thermal Kit for NI sbrio-9607/9627/9637

FP-AO-210 AND CFP-AO-210

SPECIFICATIONS AND FEATURES GUIDE NI Serial Legacy Hardware

R Series for PXI Express Digital RIO with Kintex-7 325T FPGA. ni.com/manuals. This document explains how to install and configure the NI PXIe-7822R.

Sample. LabVIEW TM Core 1 Exercises. Course Software Version 2010 August 2010 Edition Part Number B-01. LabVIEW Core 1 Exercises

FP-AO-200 AND CFP-AO-200

R Series Reconfigurable I/O Module (AI, AO, DIO) for PXI Express, 6 AI, 18 AO, 48 DIO, 1 MS/s AIO, 512 MB DRAM, Kintex-7 160T FPGA

NI CardBus-8310-to-PXI Expansion Kit

CALIBRATION PROCEDURE CAL Contents. Software

CB-27T, TBX-68T, AND CB-68T ISOTHERMAL TERMINAL BLOCKS INSTALLATION GUIDE

Reconfigurable Embedded Chassis with Integrated MXI-Express (x1) MXI-Express Switch

Getting Started with the NI PXI/PCI-1422

NI USB-9201/9221. Introduction USER GUIDE AND SPECIFICATIONS. 8-Channel, 12-Bit Analog Input Devices

R Series for USB Multifunction RIO with Kintex-7 160T FPGA. ni.com/manuals. Electromagnetic Compatibility Guidelines

Electromagnetic Compatibility Guidelines

1-Wire 4 x 128 Matrix Terminal Block for the NI PXI/PXIe-2532B

Getting Started with the NI PXI/PCI-1409

VME-GPIB Installation and User Guide

FP-AIO-600 and cfp-aio-600

Where to Start with NI ELVIS

NI High-Speed Digitizers

GETTING STARTED GUIDE NI Channel, 50 Arms Continuous, 24-Bit, Analog Input Module

Where to Start with NI ELVIS

Power Analyzer Firmware Update Utility Version Software Release Notes

RTM Contents. Definitions. Conditions SPECIFICATIONS. PCI Express Rear Transition Module for ATCA

NI PXI-1042 Series Power Supply Shuttle

LabVIEW DataFinder Toolkit

R Series Digital I/O Module for PCI Express, 128 DIO, 512 MB DRAM, Kintex-7 160T FPGA. This document describes how to begin using the PCIe-7821R.

QUICK START GUIDE. What You Need to Get Set Up

SCXI -1102/B/C. Contents CALIBRATION PROCEDURE. For NI-DAQmx

Contents. Software Requirements CALIBRATION PROCEDURE NI TB-4353

NI High-Speed Digitizers

RTM Contents. Definitions. Conditions SPECIFICATIONS. High-Speed Serial Rear Transition Module for ATCA

Transcription:

USER GUIDE NI SMB-2145/2146/2147/2148 Shielded Signal Accessories for NI 5751/5752 Adapter Modules The NI SMB-2145/2146/2147/2148 (NI SMB-214x) devices are shielded signal accessories for NI FlexRIO digitizer adapter modules (NI 5751 and NI 5752). NI SMB-214x accessories provide easy connections to other devices for testing and debugging. The following table describes each of the accessories. Table 1. NI 214x Signal Accessories Accessory NI SMB-2145 NI SMB-2146 NI SMB-2147 NI SMB-2148 Description NI 5752 analog input accessory NI 5752 digital I/O accessory NI 5751 analog input accessory NI 5751 digital I/O accessory This guide explains how to set up and use NI SMB-214x signal accessories with NI 5751/5752 adapter modules. Contents Conventions... 2 What You Need to Get Started... 2 Related Documentation... Parts Locator... Installing Cables... 5 Connecting Signals... 8 NI SMB-2145... 9 NI SMB-2146... 10 NI SMB-2147... 11 NI SMB-2148... 12 Cleaning the Accessory... 1

Specifications...1 NI SMB-2145...1 NI SMB-2146...14 NI SMB-2147...14 NI SMB-2148...15 Compliance and Certifications...16 Environmental Management...16 Technical Support Resources...17 Conventions The following conventions are used in this manual: This icon denotes a note, which alerts you to important information. This icon denotes a caution, which advises you of precautions to take to avoid injury, data loss, or a system crash. When this symbol is marked on a product, refer to the Specifications section for information about precautions to take. italic monospace Italic text denotes variables, emphasis, a cross-reference, or an introduction to a key concept. Italic text also denotes text that is a placeholder for a word or value that you must supply. Text in this font denotes text or characters that you should enter from the keyboard, sections of code, programming examples, and syntax examples. This font is also used for the proper names of disk drives, paths, directories, programs, subprograms, subroutines, device names, functions, operations, variables, filenames, and extensions. What You Need to Get Started To set up and use the NI SMB-214x, you need the following items: NI 5751R or NI 5752R, installed in a PXI/PXI Express or CompactPCI chassis Note The NI 5751R and NI 5752R are comprised of an NI FlexRIO FPGA module and an NI FlexRIO adapter module (NI 5751 or NI 5752). NI SMB-2145/2146/2147/2148 User Guide 2 ni.com

Related Documentation Parts Locator The appropriate cable assembly for your adapter module: Table 2. NI SMB-214x Cables Adapter Module/Signal Cable Description Part Number NI 5751 Analog SHC68-C68-D4 196275A-01 NI 5751 Digital SHC68-C68-D4 196275A-01 NI 5752 Analog SHC68-C68-D 18814B-01 NI 5752 Digital SHC68-C68-D4 196275A-01 At least one 50 Ω cable with SMB connectors You may find the following documents helpful as you use the NI SMB-214x. NI 5751R User Guide and Specifications NI 5752R User Guide and Specifications NI FlexRIO FPGA Module Installation Guide and Specifications These printed documents provide the specifications for your adapter module and your FPGA module. These documents are also available at ni.com/manuals. Figures 1-4 show the connectors on each of the NI SMB-214x accessories. 1 1 AI 0/16 AI 1/17 AI 2/18 AI /19 AI 8/24 AI 9/25 AI 10/26 AI 11/27 AI 4/20 AI 5/21 AI 6/22 AI 7/2 SMB-2145 Analog Input Accessory AI 12/28 AI 1/29 AI 14/0 AI 15/1 2 1 Analog Inputs <0..1> 2 VHDCI Connector Shield Ground Lug Figure 1. NI SMB-2145 Parts Locator Diagram National Instruments Corporation NI SMB-2145/2146/2147/2148 User Guide

1 2 DO 0 DO 1 DO 2 DO DO 4 DO 5 DO 6 DO 7 DI 0 DI 1 DO 8 DO 9 DO 10 DO 11 DO 12 DO 1 DO 14 DO 15 SMB-2146 Digital I/O Accessory 4 1 Digital Outputs <0..15> 2 Digital Inputs <0..1> VHDCI Connector 4 Shield Ground Lug Figure 2. NI SMB-2146 Parts Locator Diagram 1 AI 15 AI 14 AI 1 AI 12 AI 7 AI 6 AI 5 AI 4 AI 11 AI 10 AI 9 AI 8 SMB-2147 Analog Input Accessory AI AI 2 AI 1 AI 0 2 1 Analog Inputs <0..15> 2 VHDCI Connector Shield Ground Lug Figure. NI SMB-2147 Parts Locator Diagram 1 DO 0 DO 1 DO 2 DO DO 4 DO 5 DO 6 DO 7 DI 0 DI 1 DI 2 DI DI 4 DI 5 DI 6 DI 7 SMB-2148 Digital I/O Accessory 2 4 1 Digital Outputs <0..7> 2 Digital Inputs <0..7> VHDCI Connector 4 Shield Ground Lug Figure 4. NI SMB-2148 Parts Locator Diagram NI SMB-2145/2146/2147/2148 User Guide 4 ni.com

Installing Cables Caution Disconnect power from the adapter module, accessory, and any other connected hardware before connecting the cable to prevent personal injury or damage to the hardware. NI is not liable for damage resulting from improper connections. Complete the following steps to install the cable and any 50 Ω SMB cables. 1. Install the NI 5751R or NI 5752R by following the installation procedure described in the NI FlexRIO FPGA Module Installation Guide and Specifications. 2. Remove power from the adapter module by powering down the PXI/PXI Express or CompactPCI chassis or by programmatically removing power from the adapter module. Power down any external hardware intended for connection to this system.. Attach either end of the cable assembly to the VHDCI connector on the front panel of the adapter module and secure the cable with the captive screws on the cable connector. Note Do not use cables other than the cables listed in Table 2 with these accessories. 4. Attach and secure the other end of the cable assembly to the VHDCI connector of the NI SMB-214x and secure them together with the captive screws on the cable connector. National Instruments Corporation 5 NI SMB-2145/2146/2147/2148 User Guide

NATIONAL NATIONAL INSTRUMENTS INSTRUMENTS NATIONAL NATIONAL INSTRUMENTS INSTRUMENTS Figures 5 and 6 show how to connect your NI SMB-214x accessory to your NI FlexRIO system. 1 NI PXI-1042 2 4 5 1 PXI Chassis with NI 5752R 2 NI SMB-2145 NI SMB-2146 4 SHC68-C68-D4 Cable Assembly 5 SHC68-C68-D Cable Assembly Figure 5. Connecting the NI 5752R to the NI SMB-2145 and NI SMB-2146 NI SMB-2145/2146/2147/2148 User Guide 6 ni.com

AI 15 AI 14 AI 11 AI 1 AI 10 AI 9 AI 12 AI 8 SMB-2147 Analog Input Accessory AI 7 AI AI 6 AI 5 AI 2 AI 4 AI 1 AI 0 NATIONAL INSTRUMENTS NATIONAL NATIONAL INSTRUMENTS 1 NI PXI-1042 4 4 2 1 PXI Chassis with NI 5751R 2 NI SMB-2147 NI SMB-2148 4 SHC68-C68-D4 Cable Assemblies Figure 6. Connecting the NI 5751R to the NI SMB-2147 and NI SMB-2148 5. Make signal connections by connecting SMB cables to NI SMB-214x signal terminals. Refer to the Connecting Signals section for more information. Note To ensure a solid ground connection, tighten the SMB connectors by gently snapping them into place. National Instruments Corporation 7 NI SMB-2145/2146/2147/2148 User Guide

Connecting Signals 6. Apply power to the adapter module by powering on the PXI/PXIe or Compact PCI chassis or by programmatically applying power to the adapter module. 7. Power on any external hardware intended for use with this system. The NI SMB-214x provides signal connectivity to the NI 5751/5752 adapter module. You can connect to these signals from the labeled SMB connectors on the NI SMB-214x. Caution Connections that exceed any of the maximum ratings for the NI SMB-214x or the NI 5751/5752 adapter module can damage the device and the computer. Maximum input ratings are provided in the specifications document that shipped with the adapter module. NI is not liable for any damages resulting from such signal connections. Figures 7 through 10 show the pinouts of the VHDCI connectors of NI SMB-214x accessories. The analog inputs, digital inputs, and digital outputs are connected to corresponding pins on the NI SMB-214x. Refer to Table for the pin descriptions. Pin Table. VHDCI Connector Pinout Descriptions Signal Description AI <0..1> Analog input channels 0 through 1 DI <0..15> Digital input channels 0 through 15 DO <0..15> Digital output channels 0 through 15 Ground reference for signals Reserved for system use. Do not connect signals to these channels. NI SMB-2145/2146/2147/2148 User Guide 8 ni.com

NI SMB-2145 AI 0/16 AI 2/18 AI 4/20 AI 6/22 AI 8/24 AI 10/26 AI 12/28 AI 14/0 1 2 4 5 6 7 8 9 10 11 12 1 14 15 16 17 18 19 20 21 22 2 24 25 26 27 28 29 0 1 2 4 5 6 7 8 9 40 41 42 4 44 45 46 47 48 49 50 51 52 5 54 55 56 57 58 59 60 61 62 6 64 65 66 67 68 AI 1/17 AI /19 AI 5/21 AI 7/2 AI 9/25 AI 11/27 AI 1/29 AI 15/1 Figure 7. NI SMB-2145 VHDCI Connector Pinout National Instruments Corporation 9 NI SMB-2145/2146/2147/2148 User Guide

NI SMB-2146 DI 1 DO 15 DO 1 DO 11 DO 9 DO 7 DO 5 DO DO 1 1 2 4 5 6 7 8 9 10 11 12 1 14 15 16 17 18 19 20 21 22 2 24 25 26 27 28 29 0 1 2 4 5 6 7 8 9 40 41 42 4 44 45 46 47 48 49 50 51 52 5 54 55 56 57 58 59 60 61 62 6 64 65 66 67 68 DI 0 DI 14 DO 12 DO 10 DO 8 DO 6 DO 4 DO 2 DO 0 Figure 8. NI SMB-2146 VHDCI Connector Pinout NI SMB-2145/2146/2147/2148 User Guide 10 ni.com

NI SMB-2147 AI 0 AI 2 AI 4 AI 6 AI 8 AI 10 AI 12 AI 14 1 2 4 5 6 7 8 9 10 11 12 1 14 15 16 17 18 19 20 21 22 2 24 25 26 27 28 29 0 1 2 4 5 6 7 8 9 40 41 42 4 44 45 46 47 48 49 50 51 52 5 54 55 56 57 58 59 60 61 62 6 64 65 66 67 68 AI 1 AI AI 5 AI 7 AI 9 AI 11 AI 1 AI 15 Figure 9. NI SMB-2147 VHDCI Connector Pinout National Instruments Corporation 11 NI SMB-2145/2146/2147/2148 User Guide

NI SMB-2148 DI 7 DI 5 DI DI 1 DO 7 DO 5 DO DO 1 1 2 4 5 6 7 8 9 10 11 12 1 14 15 16 17 18 19 20 21 22 2 24 25 26 27 28 29 0 1 2 4 5 6 7 8 9 40 41 42 4 44 45 46 47 48 49 50 51 52 5 54 55 56 57 58 59 60 61 62 6 64 65 66 67 68 DI 6 DI 4 DI 2 DI 0 DO 6 DO 4 DO 2 DO 0 Figure 10. NI SMB-2148 VHDCI Connector Pinout Note For additional shielding, you can connect the shield ground connector on the NI SMB-214x to earth/hard ground. This terminal is connected to the shielded enclosure ground. The shield ground lug is shown in Figures 1 through 4. NI SMB-2145/2146/2147/2148 User Guide 12 ni.com

Cleaning the Accessory Specifications Disconnect all cables to the NI SMB-214x before cleaning. To remove light dust, use a soft, nonmetallic brush. To remove other contaminants, use alcohol wipes. The unit must be completely dry and free from contaminants before returning to service. These specifications are characteristic at 25 C unless otherwise noted. NI SMB-2145 Analog Input Analog input channels... 16, single-ended Typical propagation delay through NI SMB-2145... 1.2 ns Typical channel-to-channel skew... ±5 ps Typical trace characteristic impedance... 50 Ω Maximum voltage rating... 5.5 V or the maximum input voltage of the NI 5752 analog inputs, whichever is less Physical Dimensions... 0.5 cm 4.5 cm 26.5 cm (12.0 in. 1.77 in. 10.4 in.) Weight... 1,80 g (48.7 oz.) I/O connectors... One 68-pin VHDCI connector, 16 SMB jack connectors, one banana-style connector National Instruments Corporation 1 NI SMB-2145/2146/2147/2148 User Guide

NI SMB-2146 Digital I/O Digital output channels...16, single-ended Digital input channels...2, single-ended Typical propagation delay through NI SMB-2146...1.2 ns Typical channel-to-channel skew...±5 ps Typical trace characteristic impedance...50 Ω Maximum voltage rating...5.5 V or the maximum input voltage of the NI 5752 digital inputs, whichever is less Physical Dimensions...0.5 cm 4.5 cm 26.5 cm (12.0 in. 1.77 in. 10.4 in.) Weight...1,80 g (48.7 oz.) I/O connectors...one 68-pin VHDCI connector, 18 SMB jack connectors, one banana-style connector NI SMB-2147 Analog Input Analog input channels...16, single-ended Typical propagation delay through NI SMB-2147...1.2 ns Typical channel-to-channel skew...±5 ps Typical trace characteristic impedance...50 Ω Maximum voltage rating...5.5 V or the maximum input voltage of the NI 5751 analog inputs, whichever is less NI SMB-2145/2146/2147/2148 User Guide 14 ni.com

Physical Dimensions... 0.5 cm 4.5 cm 26.5 cm (12.0 in. 1.77 in. 10.4 in.) Weight... 1,80 g (48.7 oz.) I/O connectors... One 68-pin VHDCI connector, 16 SMB jack connectors, one banana-style connector NI SMB-2148 Digital I/O Digital input channels... 8, single-ended Digital output channels... 8, single-ended Typical propagation delay through NI SMB-2148... 1.2 ns Typical channel-to-channel skew... ±5 ps Typical trace characteristic impedance... 50 Ω Maximum voltage rating... 5.5 V or the maximum input voltage of the NI 5751 digital inputs, whichever is less Physical Dimensions... 0.5 cm 4.5 cm 26.5 cm (12.0 in. 1.77 in. 10.4 in.) Weight... 1,80 g (48.7 oz.) I/O connectors... One 68-pin VHDCI connector, 16 SMB jack connectors, one banana-style connector National Instruments Corporation 15 NI SMB-2145/2146/2147/2148 User Guide

Compliance and Certifications Environmental Management National Instruments is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers. For additional environmental information, refer to the NI and the Environment Web page at ni.com/environment. This page contains the environmental regulations and directives with which NI complies, as well as other environmental information not included in this document. Waste Electrical and Electronic Equipment (WEEE) EU Customers At the end of the product life cycle, all products must be sent to a WEEE recycling center. For more information about WEEE recycling centers, National Instruments WEEE initiatives, and compliance with WEEE Directive 2002/96/EC on Waste Electrical and Electronic Equipment, visit ni.com/environment/weee. RoHS National Instruments (RoHS) National Instruments RoHS ni.com/environment/rohs_china (For information about China RoHS compliance, go to ni.com/environment/rohs_china.) NI SMB-2145/2146/2147/2148 User Guide 16 ni.com

Technical Support Resources The National Instruments Web site is your complete resource for technical support. At ni.com/support you have access to everything from troubleshooting and application development self-help resources to email and phone assistance from NI Application Engineers. National Instruments corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas, 78759-504. National Instruments also has offices located around the world to help address your support needs. For telephone support in the United States, create your service request at ni.com/support and follow the calling instructions or dial 512 795 8248. For telephone support outside the United States, contact your local branch office: Australia 1800 00 800, Austria 4 662 457990-0, Belgium 2 (0) 2 757 0020, Brazil 55 11 262 599, Canada 800 4 488, China 86 21 5050 9800, Czech Republic 420 224 25 774, Denmark 45 45 76 26 00, Finland 58 (0) 9 725 72511, France 01 57 66 24 24, Germany 49 89 74110, India 91 80 41190000, Israel 972 6977, Italy 9 02 4109277, Japan 0120-527196, Korea 82 02 451 400, Lebanon 961 (0) 1 28 28, Malaysia 1800 887710, Mexico 01 800 010 079, Netherlands 1 (0) 48 4 466, New Zealand 0800 55 22, Norway 47 (0) 66 90 76 60, Poland 48 22 28 90 10, Portugal 51 210 11 210, Russia 7 495 78 6851, Singapore 1800 226 5886, Slovenia 86 425 42 00, South Africa 27 0 11 805 8197, Spain 4 91 640 0085, Sweden 46 (0) 8 587 895 00, Switzerland 41 56 2005151, Taiwan 886 02 277 2222, Thailand 662 278 6777, Turkey 90 212 279 01, United Kingdom 44 (0) 165 52545 National Instruments Corporation 17 NI SMB-2145/2146/2147/2148 User Guide

LabVIEW, National Instruments, NI, ni.com, the National Instruments corporate logo, and the Eagle logo are trademarks of National Instruments Corporation. Refer to the Trademark Information at ni.com/trademarks for other National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents. 2010 National Instruments Corporation. All rights reserved. 75568A-01 May10