The Most Advanced Digital Variable Impedance Transducer for Noncontact Linear Position / Displacement Sensing

Similar documents
PTT 280, 380 AND 480 WHITE PAPER

the Interactive Catalog

Inductive displacement measurement system model series IE25P with programmable analogue interface

DMT PERFORMING UNDER PRESSURE DMT. All-Media Pressure Scanner Features. Applications. Description 1/8

ECL150/ECL150e. Eddy-Current Displacement Sensor INSTRUCTION MANUAL. Measurement Systems from LION PRECISION

Operation Manual CX10 1/8 DIN Microcomputer Based Conductivity/Resistivity Controller

PRESSURE TRANSDUCER Setra 276

955 ebrik INSTALLATION MANUAL. Series ebrik ABSOLUTE PROCESS CONTROL KNOW WHERE YOU ARE... REGARDLESS LINEAR DISPLACEMENT TRANSDUCERS

Manual of Electrical Installation for Pressure Probes KS and KS-SIL2 series

LAKEWOOD INSTRUMENTS MODEL 1575e WATER TREATMENT CONTROLLER

ED-1100 PORTABLE VARIABLE EDDY CURRENT INSTRUMENT

TMS 9000 Series Torque Measurement System DIGITAL TELEMETRY DESIGNED FOR TODAY & TOMORROW

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

BTL6-A_10-M -A1-S115. Data Sheet. english

Model T28 Transmitter

E4PA. Ultrasonic Displacement Sensor. Ordering Information

Industrial. Laboratory and Field. Accessories. Product Selection Guide. Analyzers 1 Controllers 2 Transmitters 3 Monitors 4

Input Frequency: 650 range 50/60Hz 675 range Hz Input Ranges in Amps: Measurement Maximum Inrush

M5100 Heavy Industrial Pressure Transducer

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

TPE 1464 Series Pressure Transducer

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

MicroTrans EQ Signal Processor. Operation & Maintenance Manual

RK-5 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED CONNECTION. Main features

POSIROT. PRAS26 Magnetic Angle Sensor. Magnetic Angle Sensors. Datasheet

Transducers for Pt-100/1000, Resistors

High Voltage DC Meter

HIGH-VOLTAGE DC METER

RK-A CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

Operation Manual TX10 1/8 DIN Microcomputer Based ph/orp Controller

Heritage Group Inc. Magnetic susceptibility meter SM-100 USER S MANUAL. Publication Date: April 2005

DELTA CONTROLS CORPORATION

E4PA-N. Application Examples. Features. Ultrasonic Displacement Sensor. Now, more advanced with a new mutual interference prevention function.

DTM Distributed Transmitter Monitor

Principle of Operation

PQ-Box 100, 150, 200 & 300 Power Quality Analyser Clamps & Accessories

Internal Buffer/Boiler Module HZS 534

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

Inductive Cylinder Position Sensors

MODEL SELECTION SINGLE-PHASE, TWO-WIRE (ONE-ELEMENT) MODELS WITH INTERNAL CURRENT SENSOR

Ellab Temperature Indicator

Trident and Trident X2 Digital Process and Temperature Panel Meter


HEAVY DUTY INCLINOMETER ANALOG & RS232 INTERFACE

Trend-1 Vibration Data Logger. User Manual

D-510 PISeca Single-Electrode Capacitive Sensor Probe

Datasheet.

Model User Manual Revision E 04/29/99. OEM Gaging System. Part Number R01

MP-2000 Dual Channel LVDT/RVDT Readout/Controller

SINGLE-CHANNEL PROCESS CONTROLLERS & TEMP. DISPLAYS D3820/D3830 Series

Isolated Process Current Input with Loop Power 7B35

Temperature Switches

Inc. FLO-CAL Liquid Calibration System FLO-CAL SOFTWARE FLEXIBLE DESIGN TO MEET YOUR LIQUID FLOW CALIBRATION REQUIREMENTS

Valve and Case Expansion Monitor Specifications

SC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. (407) Phone: Website:

Isolated Process Current Input 7B32 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Process Current Output 7B39 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

EPWR Series. RoHS. Product Description. Available Products. Installation Instructions 01

D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES

EDX-10 Series. Compact Recording System

SC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. Phone: (407) Fax: (407) Vulcan Road Apopka, Florida 32703

U7100 Pressure Transducer

MODEL 9250 Preliminary data sheet

The World s Smallest Displacement Sensor!!

NAMUR PS1-6,5-25-N PS2-6,5-25-N PS N PS N ( DIN )

Safety. 2. Configuration - Operation 2.1 RTD Selection 2.2 Driver Test Header. 3. Diagnostics 3.1 ph Input 3.2 Temperature Input

MTII4200 Level Transmitter Installation, Operation & Maintenance Instructions

Model 8042 Submersible Accelerometer

BRC SERIES 20kW High Voltage Power Supply

MDP200 Series. Differential Pressure Sensor FEATURES APPLICATIONS DESCRIPTION

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

KDM-8200 EuroCard Noncontacting Displacement Measuring System

Isolated Voltage Input 7B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

FTM84/85 Feature Application. Temperature & Humidity / Flow Measuring Specialist

Pile Driver Weld Immune Sensors

HIGH ACCURACY PRESSURE TRANSDUCERS

Metrix DPS 1.35 Software Overview. January 2018

Electrostatic Fieldmeter Model 775

NF770 Temperature Compensation Liquid Flow Computer

SX 6000 Paperless Recorder

More Precision. thermoimager TIM // Compact thermal imaging cameras

MA Series. Safety, Technology & Innovation. Description. Approvals. Operation. Applications. Declaration of Conformity

4-Channel Vibration Datalogger

Switch on / off. For switching off please press button for approx. 5 sec.

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

Inductive Proximity Sensor

METERING/DISPLAY MANUAL

More Precision. eddyncdt // Eddy current sensors for displacement and position

An OR Operation. Or (O) Function I0.4 Q0.1 I0.5 I0.5 I0.4 Q0.1. Input 3. Input 4. Output 2

5D Windows Configurator. Instruction Manual

TNG-3B derives its operating power from the serial port. The DTR, RTS, and both data lines are all used, and must be properly connected.

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

PT2060 Monitor. PT2060/91 SIM System Interface Module. Specifications. Electrical. Messtechnik

LION PRECISION. Application Note. Thickness Measurement With Noncontact Sensors. LA June, Applicable Equipment: Applications: Summary:

MEMSENSE. AccelRate3D. Triaxial Accelerometer & Gyroscope Analog Inertial Sensor

Model KT 53 Cooling incubators with thermoelectric cooling

The SF-586b Insertion Flow Meter For Compressed Air, Gases And Exhaust Air (up to 400 C) In Pipe Diameters From 25mm to 5000mm

HD25A. Absolute Industrial Rugged Metal Optical Encoder Absolute Industrial Rugged Metal Optical Encoder, Page 1 of 5. Description.

ASM Series. Advanced Signal Multi-scanner. Functional signal multi-scanner adding flexibility to your calibration needs

Transcription:

SENSOR DATA SHEET The Most Advanced Digital Variable Impedance Transducer for Noncontact Linear Position / Displacement Sensing 800-552-6267 kamansensors.com measuring@kaman.com

Features v Self tuning bridge, will perform with nearly any sensor, any conductive target v Pushbutton calibration v Pushbutton temperature compensation v Pushbutton zeroing v Embedded intelligence, all functions accessible without a PC v Large easy to read digital display v Scrolling menus for set up and calibration v Ethernet communication v No sensor, shorted sensor detection v Programmable switched output Applications v Position, vibration, proximity sensing v Part sorting v Process control v Laboratory test v Engine dynamics testing v Condition monitoring Digital Circuit Design Kaman is not new to digital circuit design. From the late 1980s we have had a digital circuit sensor in production. Kaman has continued to build on the foundations developed with the EASI-9500, KµDA, and ThreadChecker products. What s Different This Time Probably the biggest difference between the digivit and past digital inductive linear displacement sensors is that all functions can be accessed through 4 pushbuttons on the front panel. All information is displayed on an easy to read, integral digital display. There is no requirement to connect to a PC! What s Unique about digivit Technological innovation has resulted in a self tuning bridge. There is no longer the need to connect to a PC to download a configuration file when changing sensors or doing high level calibrations. Attaching a sensor to the digivit and performing a simple calibration procedure via the pushbuttons will tune the bridge. It not only tunes the bridge, its self optimization will ensure the best performance possible for any given, combination of sensor, target, cable & calibration. Calibrations Linearity calibration is a simple routine via the pushbuttons. Multiple point calibrations are possible. The 2-point calibration provides a reliable, precise repeatable output, the 6-point calibration provides outstanding linearity, and the 21 point calibration the best possible linearity. Temperature compensation calibration by the user is also possible. Simply positioning the sensor at 2 different positions within the calibrated range at 2 different temperatures and depressing a pushbutton will complete a temperature compensated calibration. The same procedure can also be done with the electronics.

Where Everything Is 1. Sensor connection 2. Digital display 3. Scroll up pushbutton 4. Scroll down pushbutton 5. Escape pushbutton 6. Enter pushbutton 7. I/O terminals 8. Ethernet connection Digital Display Options Percent of full scale (default) Voltage output Current output 1 2 3 4 5 6 Analog Output Options 0-5 VDC 0-10 VDC (default) +/- 5 VDC +/- 10 VDC 4-20 ma 0-20 ma Calibrations 2 point 6 point 21 point Active temperature compensation Miscellaneous Zero Ethernet connection 2 point adjust Programmable switched output 0.78 (19.8) 2.28 (57.9) 0.28 (7.1) 3.38 (85.9) 7 8 1.44 (36.6) 2.75 (69.9) 10 9 8 7 6 5 4 3 2 1 0.38 (9.7) 0.44 (11.2) 0.25 (6.4) 1.50 (38.1) Operating temperature range: Storage temperature range: Sensor integral cable length: 2 meters Sensors -55 C to 200 C Sensors -55 C to 200 C Extension cables available Electronics 0 C to 50 C Electronics -20 C to 70 C Input power: 18-28VDC (130mA @24VCD)

Probe Options Although the digivit will work with nearly any single coil sensor and any conductive target, the following sensors have been characterized over standard ranges with an aluminum target. M3 x.5 2U 4U 9U 12U 0.66 (16.8) #10-32 3/8-332 1/2-28 0.08 (2.00) 0.95 (24.1) 1.23 (31.2) 1.26 (32.0) 0.15 (3.81) 0.34 (8.64) 0.46 (11.68) 16U 26U 38U 51U 3/4-20 3/4-20 3/4-20 3/4-20 1.37 (34.8) 1.15 (29.2) 1.15 (29.2) 1.15 (29.2) 0.63 (16.0) 1.00 (25.4) 0.51 (13.0) 1.50 (38.1) 0.71 (18.0) 2.00 (50.8) 0.91 (23.1) Calibration fixture 2U-16U sensors English/Metric 855578-001 Calibration spacer set 26U-51U (0.050, 0.100, 0.200, 0.300, 0.400, 0.500, 1.000) 850859-001

Specifications Characterized with an aluminum target 2U 4U 9U 12U 16U 26U 38U 51U Offset Inch 0.002 0.005 0.010 0.016 0.020 0.032 0.050 0.100 (mm) (0.05) (0.13) 0.25 (0.40) (0.50) (0.80) (1.20) (2.5) Short range Inch 0.010 0.025 0.050 0.080 0.100 0.160 0.250 0.300 (mm) (0.25) (0.60) (1.25) (2.00) (2.50) (4.00) (6.00) (7.50) Standard range Inch 0.020 0.050 0.100 0.160 0.200 0.320 0.500 0.600 (mm) (0.50) (1.30) (2.50) (4.00) (5.00) (8.00) (12.00) (15.00) Extended range Inch 0.030 0.070 0.150 0.240 0.320 0.500 0.800 1.000 (mm) (0.75) (1.75) (3.75) (6.00) (8.00) (12.50) (20.00) (25.00) Typical specifications for standard range, aluminum target, standard cable length: Nonlinearity 6 pt calibration ± %FS <0.3% Nonlinearity 21 pt calibration ± %FS <0.1% Static Resolution RMS %FS <0.001% Resolution @ 100Hz RMS %FS <0.01% Resolution @1000Hz RMS %FS <0.02% Thermal sensitivity %FS/ F 0.05 (sensor only) (%FS/ C) (0.1) Thermal sensitivity w/temp comp cal %FS/ F 0.01 (sensor only) (%FS/ C) (0.02) Performance with Magnetic Target Materials Characterized with a 4130 steel target, 2m cable 2U 4U 9U 12U 16U 26U 38U 51U Offset Inch 0.002 0.005 NR 0.016 0.020 0.032 0.050 0.100 (mm) (0.05) (0.1) (0.40) (0.50) (0.80) (1.20) (2.5) Short range Inch 0.010 0.020 NR 0.060 0.100 0.160 0.250 0.300 (mm) (0.25) (0.50) (1.5) (2.50) (4.00) (6.00) (7.50) Standard range Inch 0.020 0.040 NR 0.120 0.200 0.320 0.500 0.600 (mm) (0.50) (1.00) (3.00) (5.00) (8.00) (12.00) (15.00) Extended range Inch 0.030 NR NR 0.160 0.320 0.500 0.800 1.000 (mm) (0.75) (4.00) (8.00) (12.50) (20.00) (25.00) Typical specifications for standard range, 4130 target, standard cable length: Nonlinearity 6 pt calibration ± %FS <0.3% <1.5% NR <0.3% <0.3% Nonlinearity 21 pt calibration ± %FS <0.2% <0.2% NR <0.2% <0.1% Static Resolution RMS %FS <0.001% <0.001% NR <0.001% <0.001% Resolution @ 100Hz RMS %FS <0.01% <0.01% NR <0.01% <0.01% Resolution @1000Hz RMS %FS <0.02% <0.02% NR <0.02% <0.02% Thermal sensitivity %FS/ F 0.05 0.8 NR 0.8 0.1 (No Compensation) (%FS/ C) (0.1) (1.6) (1.6) (0.2) Thermal sensitivity w/temp %FS/ F 0.02 0.02 NR 0.02 0.01 comp calibration (%FS/ C) (0.04) (0.04) (0.04) (0.02) NR = Not Recommended for 4130 targets

Ordering Information The components required to complete a sensor system are sold separately. A complete system includes: Or Electronics Extension cable (optional) Sensor Without calibration Straight x Straight 852395-XXXXX 2U 850904-006MT 855949-000 Straight x Rt Angle 855948-XXXXX 4U 854575-1F079 With calibration 1 meter -F03R3 9U 854574-1F079 855949-001 2 meter -F06R6 12U 854573-1F079 3 meter -F09R8 16U 854572-1F079 4 meter -F13R1 26U 854571-1F079 5 meter -F16R4 38U 854570-1F079 6 meter -F19R6 51U 854653-1F079 7 meter -F23R0 8 meter -F26R2 Optional Factory Calibration The digivit is designed so the user can perform both linearity and temperature compensated calibrations. If desired, the digivit can be ordered with factory calibration (part number 855578-001). If ordering factory calibration the following information must be provided at the time of order. Factory temperature compensation is performed at two displacements, 10% of the specified range and 90% of the specified range, and two temperatures, ambient and 10 C above ambient. If a temperature compensated calibration is desired under other conditions, contact Kaman to discuss the details. Linearity calibration type: Temperature compensated calibration: Sensor model: Cable extension: Target: Offset: Range: 2 point, 6 point or 21 point yes/no from the available models above from available models above aluminum, 4130 steel or customer supplied in inch or mm units in inch or mm units Offset Minimum Output Range Maximum Output Target