EOS-6000 Series Optical A/B Switch User Manual DC Version

Similar documents
UTAH-100/XHDA SERIES

Medallion 7200 Series CATV Fiber Amplifier

DLS 5405 Operating Manual High Bandwidth Noise Injection Unit

Agilent OBSAI Protocol Tester

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL

DVBus , and Multiplexer and demultiplexer assemblies for video channels USER MANUAL

Medallion 7200 Series CATV Fiber Amplifier

16-SLOT IN-BAND MANAGEMENT CHASSIS

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

OTEB-CO-P PRE-AMP EDFA INSTRUCTION MANUAL

RZ5/RZ5D/RZ6 Processor. Operator s Manual

Agilent 70612B K18 Switch Matrix

Dell Networking S4810 Open Networking (ON) Getting Started Guide

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

4 Channel 4~20mA/0~10VDC Analog Data Fiber Link System

Getting Started with the Agilent Serial BERT N4906B. You only need a few minutes to get started with the Serial BERT.

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

Agilent Technologies E5339A 38-Pin Low-Voltage Probe

OPERATOR MANUAL. OSD2053P SERIES MICRO 10/100Base-T to 100Base-X MEDIA CONVERTER. WITH PoE SOURCE

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Manual Version: V1.00. Video Decoder Quick Guide

Firmware Guide. Keysight PXIe Chassis Family

Quick Start Guide. C-100 Series Switches

Metro-Optical Transport Access Nodes

Perle SMI Media Converter Installation Guide

Installation Job Aid for Ethernet Routing Switch 3600 Series

Model 3955 DFB 1550nm Laser in TO-can

VFI RTG PDU 6-10K. Installation and user manual. Service and support: Call your local service representative

Multicom 1550nm High Power Erbium Doped Fiber Amplifier MUL 2RU EDFA 1550 XX xx

User Manual TL-DA14-HD2 1x4 HDMI Splitter & Distribution Amplifier All Rights Reserved Version: TL-DA14-HD2_160926

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Installation Job Aid for Ethernet Routing Switch 5900 Series

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR065-48S / OPR065-48R. Manual

Keysight E5864A Removable Hard Drive for Series Logic Analyzers. Installation Guide

DS-1H05 Ethernet-over-Coax Extender. User Manual

Manual Version: V1.00. Video Decoder User Manual

RZ2 BioAmp Processor. Operator s Manual

DM3058/DM3058E Digital Multimeter

ChromaFlex Chassis. Hardware Interface Manual

OTEB-CO-B Series. Booster EDFA OPERATING MANUAL

Siemens Industrial s

TippingPoint Zero Power High Availability Installation Guide

LBO-H2 Series DIRECT PLUGGABLE LINKBRIDE TM FIBER OPTIC HDMI 2.0 TRANSMISSION SYSTEM

Model 7705 Control Module

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

CSM200 Expansion Tray

Customer Replacement Procedure

iconverter 2-Module Power Chassis

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

OPERATOR MANUAL OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM

MT1810A 4 Slot Chassis Operation Manual

Installation Job Aid for VSP 4850GTS

VCL-TP, Teleprotection Equipment With Trip Counter Display Panel

MC-12 Software Installation Instructions

OFFICE UPS MULTI-DEVICE PROTECTION UPS 500S/600S/750S

Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide

Network Camera. Quick Guide DC-B1203X. Powered by

HES-3109 SERIES 9 PORTS 10/100/1000BASE-T MANAGEMENT ETHERNET SWITCH

Customer Replacement Procedure

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A

SATA II HDD Canister KISS DA 435 Quick Reference Guide

XBR V4 INSTALLATION AND USER GUIDE

1690-Series Logic Analyzers

Stride SE2 Series Unmanaged Industrial Ethernet Switches and Media Converters

Precise Fiber Couple Laser Light Source

REDUNDANT POWER SUPPLY SYSTEM FOR NETGEAR RPS CAPABLE ETHERNET SWITCHES

COGNEX. Checker SensorView. Quick Reference Guide

Industrial Serial RS-232 to Fiber Converter. KSC-200 Series. Installation Guide

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input.

Errata. Agilent References in this manual. About this manual. Support for your product

RS-485 Fiber-Optic Link RS-485 to Multi-Mode Fiber-Optic converter ST Fiber Connectors DIN Rail Mount

DXF-200 DVI/HDMI Optical Extension System

Installing the Cisco MDS 9020 Fabric Switch

4100/ VDC Converter Installation Instructions

800xA Networks. NE801 User Manual. Power and productivity for a better worldtm

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

PoE Powered Gigabit Ethernet Media Converters 1000BASE-T TO 1000BASE-SX/LX. KGC-352 Series. Installation Guide

PSW-002. Fiber Optic Polarization Switch. User Guide

XBR V3 INSTALLATION AND USER GUIDE Rev 03. xbr V3 Installation and User Guide Page 1 of 14. (preliminary)

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

MC 11 EB-2 Power supply cabinet with external bus, AC version

MicroLink Installation Operation & Specifications Manual. General Description

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

Installation Job Aid for VSP 4450GTX-HT- PWR+

Customer Upgrade Procedure

10/100 Ethernet Fiber Link Card System

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

DS1000B Series Digital Oscilloscope

LASER PLUS OPERATING INSTRUCTIONS

EC Series. Safety Guide

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

PT-7728/7828 Quick Installation Guide

Kinetix 300 Memory Module Programmer

Dell Networking S4100-ON Series. Set-Up Guide

Contents. HP E1586A Rack Mount Terminal Panel User s Manual

PIM-Mini Pulsed Current Source Operation Manual

Transcription:

EOS-6000 Series Optical A/B Switch User Manual DC Version For more information on this and other products: Contact Sales at EMCORE 626-293-3400, or visit www.emcore.com.

Table of Contents Table of Contents...2 Safety Information...3 Power Requirements...3 Safety Instructions...3 Before Initializing and Operating the Unit...3 Safety Symbols...3 Getting Started...4 Before Initializing and Operating the Unit...4 Note: Keep the packaging....4 Optical Switch Outline Drawing (Units in mm)...7 Operating Environment...9 Temperature...9 Humidity...9 Introduction...9 Front Panel View...10 Rear Panel View (DC)...10 Sample Application...11 Functionality...11 Network management...11 Output Indication...11 Operation...12 Manual Switch...12 Normal Operating Condition...12 Applicable Standards Compliance...13 EMI/EMC...13 Packaging...13 Packaging...13 2 of 14

Safety Information Power Requirements The system operates from a DC power source that supplies -36 to -60 V DC. Safety Instructions The following safety instructions must be observed whenever the unit is operated, serviced, or repaired. Failure to comply with any of these instructions or with any precaution or warning contained in the user s manual is in direct violation of the standards of design, manufacture, and intended use of the unit. Emcore assumes no liability for the customer s failure to comply with any of these safety requirements. Before Initializing and Operating the Unit Inspect the unit for any signs of damage, and read the user s manual thoroughly. Install the unit as specified in the Getting Started section. Ensure that the unit and any devices or cords connected to it are properly grounded. Safety Symbols The following symbols and messages can be marked on the unit (Table 1). Observe all safety instructions that are associated with a symbol. Table 1: Safety Symbols Symbol Description Laser safety. See the user s manual for instructions on handling and operating the unit safely. See the user s manual for instructions on handling and operating the unit safely. Electrostatic discharge (ESD). See the user s manual for instructions on handling and operating the unit safely. Frame or chassis terminal for electrical grounding within the unit. Protective conductor terminal for electrical grounding to the earth. WARNING CAUTION The procedure can result in serious injury or loss of life if not carried out in proper compliance with all safety instructions. Ensure that all conditions necessary for safe handling and operation are met before proceeding. The procedure can result in serious damage to or destruction of the unit if not carried out in compliance with all instructions for proper use. Ensure that all conditions necessary for safe handling and operation are met before proceeding. 3 of 14

Getting Started Before Initializing and Operating the Unit 1. Inspect the optical switch for any signs of damage, and read the User s Manual thoroughly. 2. Install the optical switch as specified in the Getting Started section. 3. Ensure that the optical switch and any devices or cords connected to it are properly grounded. 4. Become familiar with all safety symbols and instructions to ensure that the optical switch is operated and maintained safely. Initial Inspection WARNING WARNING: To avoid electrical shock, do not initialize or operate the unit if it bears any sign of damage to any portion of its exterior surface, such as the outer cover or panels. Check that the unit and contents are complete: 1. Wear an anti-static wrist strap and work in an electrostatic discharge (ESD) controlled area. 2. Inspect the shipping container for any indication of excessive shock to the contents, and inspect the contents to ensure that the shipment is complete. 3. Inspect the unit for structural damage that can have occurred during shipping. Note: Keep the packaging. Immediately inform Emcore and, if necessary, the carrier if the contents of the shipment are incomplete, if the unit or any of its components are damaged or defective, or if the unit does not pass the initial inspection. 4 of 14

Storing and Shipping To maintain optimum operating reliability, do not store the unit in locations where the temperature falls below -25 C or rises above 65 C. Avoid any environmental condition that can result in internal condensation. Ensure that these temperature and humidity requirements can also be met whenever the unit is shipped. Claims and Repackaging Immediately inform Emcore and, if necessary, the carrier, if The contents of the shipment are incomplete The unit or any of its components are damaged or defective The unit does not pass the initial inspection In the event of carrier responsibility, Emcore will allow for the repair or replacement of the unit while a claim against the carrier is being processed. Returning Shipments to Emcore Emcore will only accept returns for which an approved Return Material Authorization (RMA) has been issued. This number must be obtained prior to shipping any material to Emcore. The owner s name and address, the model number and full serial number of the unit, the RMA number, and an itemized statement of claimed defects must be included with the return material. Ship the return material in the original shipping container and packing material. If these are not available, typical packaging guidelines are as follows: 1. Wear an anti-static wrist strap and work in an ESD controlled area. 2. Wrap the unit in anti-static packaging. Use anti-static connector covers, as applicable. 3. Pack the unit in a reliable shipping container. 4. Use enough shock-absorbing material (10 to 15 cm or 4 to 6 in on all sides) to cushion the unit and prevent it from moving inside the container. Pink poly anti-static foam is recommended. 5. Seal the shipping container securely. 6. Clearly mark FRAGILE on its surface. 7. Always provide the model and serial number of the unit and, if necessary, the RMA number on any accompanying documentation. 8. Please contact the RMA department, using the contact information at the beginning of this document, to provide an RMA number and a shipping address. Unpacking 1. Inspect the shipping boxes for any obvious damage. 2. Unpack the unit from all packaging boxes. 5 of 14

3. Inspect the appearance of the unit for any shipping damage. 4. In case of damage, document and inform the shipping company and your local representative. 5. Save the shipping boxes and their inserts for any future reshipment for upgrade or repair. NOTE: In the event of a reshipment back to the manufacturer, any additional damage caused by not using the original boxes will be considered the responsibility of the customer. Optical Switch Mounting and Power Connection 1. Mount the unit into a 19-inch wide rack or cabinet. 2. Turn the unit power supply switch located on the rear panel off. 3. Connect wires DC+, DC-, and GND to the pluggable terminal block that is connected to the DC input of the power supply. The DC power source must be 36 60VDC and wires used must handle at least 10VA. 4. Turn the unit power switch to the ON position. 6 of 14

Optical Switch Outline Drawing (Units in mm) 7 of 14

Operating the Optical Switch WARNING To avoid the risk of injury or death, always observe the following precautions before initializing the optical switch. If using a voltage-reducing autotransformer to power the optical switch, ensure that the common terminal connects to the earthed pole of the power source. Use only the type of power cord supplied with the optical switch. Connect the power cord only to a power electrical outlet equipped with a protective earth contact. Never connect to an extension cord that is not equipped with this feature. Willfully interrupting the protective earth connection is prohibited. Never look into the end of an optical cable connected to an optical output device that is operating. Laser radiation is invisible, and direct exposure can severely injure the human eye. For more information, see the User s Manual of the laser source in use. Turning off the power to the optical switch does not block the externally supplied radiation to the input of the optical switch, or the output of the optical switch. Do not use the optical switch outdoors. To prevent potential fire or shock hazard, do not expose the optical switch to any source of excessive moisture. Do not operate the optical switch when its covers or panels have been removed. Do not interrupt the protective earth grounding. Any such action can lead to a potential shock hazard that can result in serious personal injury. Do not operate the optical switch if an interruption to the protective grounding is suspected. In this case, ensure that the optical switch remains inoperative. Unless absolutely necessary, do not attempt to adjust or perform any maintenance or repair procedure when the unit is opened and connected to a power source. Repairs are to be carried out only by a qualified professional. Do not attempt any adjustment, maintenance, or repair procedure to the optical switch s internal mechanism. Disconnect the power cord from the unit before adding or removing any components. Operating the unit in the presence of flammable gases or fumes is extremely hazardous. Do not perform any operating or maintenance procedure that is not described in the User s Manual. Some of the optical switch s capacitors can be charged even when the unit is not connected to the power source. 8 of 14

Operating Environment In order for the optical switch to meet the warranted specifications, the operating environment must meet the following conditions for temperature and humidity. WARNING 1. Do not use the optical switch outdoors. 2. To prevent potential fire or shock hazard, do not expose the optical switch to any source of excessive moisture. Temperature The optical switch can be operated in the temperature range of 0 C to 50 C. Humidity The optical switch can be operated in environments with up to 85% humidity, non-condensing (0 C to 50 C). Do not expose it to any environmental conditions or changes to environmental conditions that can cause condensation to form inside the optical switch. Introduction The Model EOS-6000 Optical A/B Switch series product line is a high performance solution for network protection and optical redundancy. Packaged in a convenient 1RU housing, this line of optical switches provides an automatic or manual fiber switching function to protect the network from inadvertent service outages due to up-stream optical signal degradation. Each fiber s optical signal power level is continuously monitored, as is an adjustable optical trip threshold for each channel. If the primary fiber s optical signal power level falls below the desired optical trip threshold, the unit automatically switches to the secondary fiber, thus eliminating the need for intervention of a system operator. The EOS-6000 is capable of manual switching or can be switched remotely via SNMP adding optical protection to many system applications. 9 of 14

Front Panel View Power Main Input Backup Input Output Manual switch Indicator Status Status status Rear Panel View (DC) Main Line Backup Line Output Com Port Select Switch DC Terminal Block Input Input RS232 Port for management RJ45 Port for management Power Switch 10 of 14

Sample Application The diagram below shows a typical CATV application that allows fully redundant transmitters and fiber paths, with automatic protection to the network via the EOS-6000 switch. Contact your Emcore sales representative for more information on Emcore s complementary product lines. Functionality Network management The EOS-6000 supports SNMP1.0 protocol for remote network management. In addition to SNMP, the EOS-6000 also supports web browser, telnet and remote firmware upgrade. EOS-6000 supports the following Network Management functions. 1) Monitoring the main and backup channel s optical power; 2) Obtaining the output status; 3) Switching between the main line and the backup line 4) Setting up the following parameters: Parameters Switching Threshold Pre-alarm db value Operating mode Description Power value for auto-switch The Pre-alarm power value (dbm) (for warning) = Switching Threshold + Pre-alarm db value Mode 0: Switch remains on the backup line even if the power of the main line returns to normal. Mode 1: Switches to the main line when the power of the main line rises above the Pre-alarm power value (dbm). See the EOS-6000 Network Management Manual for more information. Output Indication 1) A blinking LED on either the main line or backup line indicates the current working channel. 2) If the working channel s optic power is: 11 of 14

a. Above the Pre-alarm power value (dbm), the output indicator is green; b. Above the Switching Threshold but below the Pre-alarm power value (dbm), the output indicator is yellow; c. Below the Switching Threshold, the output indicator is red. 3) If the optic power of either the main line or backup line is higher than the Switching Threshold, the output indicator is green, otherwise red. Operation 1) If the working channel is on the main line currently, it will not switch to the backup line until the main line s optic power drops below the switching threshold and the backup line s optic power is higher than the switching threshold. 2) If the working channel is on the backup line currently, a. For mode 0, it will not switch to the main line until the backup line s optic power drops below the switching threshold and the main line s optic power is higher than the switching threshold. b. For mode 1, it will switch to the main line at once when the main line s optic power rises above the Pre-alarm power value (dbm). Manual Switch The manual switch is enabled and will take effect only when the optic powers of two channels are both either above or below the switching threshold in mode 0 or below the switching threshold in mode 1. Normal Operating Condition The normal operating condition is when the unit is powered on, receiving optical power on both its main and backup working channels with optical powers above the pre-alarm power values. The optical switch is positioned to passively direct the main optical power to the output port. In this case, the front panel LED indicators, Power, Main, and Output are steady green, and Backup is blinking green. Optical Characteristics PROPERTY UNITS MIN. TYP. MAX. Operating Wave Length nm 1310 +/- 10 or 1550+/-20 Insertion Loss db 1.0 1.3 Return Loss db 55 60 Polarization Dependent db 0.06 0.1 Loss Repeatability db +/-0.01 +/-0.02 Isolation db -60-50 Input Optical Power dbm 24 Switching Time ms 25 General and Mechanical Specifications PROPERTY REQUIREMENT COMMENTS Switching Threshold 20 db range see datasheet Settable within range Switching Mode Auto, Manual, remote 12 of 14

Optical Connector SC/APC Other styles available Monitoring Interfaces 100 Base-T Ethernet Rear Panel RS-232 interface LED Indicators Operating Temperature 0 C to 50 C Storage Temperature -25 C to 65 C Power Consumption 5W Maximum SNMP V1 Reserved for Factory Use Power, Main, Backup, and Output Indicators Supply Range (VDC) 36-60 VDC Dimensions 430x300x44mm Applicable Standards Compliance EMI/EMC EN55022:2006 conducted emissions, information technology equipment EN55022:2006 radiated emissions, information technology equipment EN55024: 1998/A1:2000/A2: 2002 IEC 61000-4-2: 2001 IEC 61000-4-3:2008 IEC 61000-4-4:2004 IEC 61000-4-6:2006 FCC Part 15 (CFR 47), subpart B, Class B Packaging Packaging The module shall be sealed in an anti-static bag. The product manual will be installed in an anti-static bag and shipped with the unit MIB s and manuals will be provided on a CD-ROM supplied with unit 13 of 14

Laser Safety Class 1 Device This equipment is inherently classified as a Class I laser product, since the equipment contains no laser or light emitting diode (LED) of a higher class number. WARNING Although unit is classified as a Class 1 device, a hazard can exist due to laser radiation emitting from the output port of the optical switch, and thus eye safety precautions should be adhered to at all times. Never look into an uncovered optical bulkhead connector or the end of an optical cable connected to an optical output device that is operating. Laser radiation is invisible, and direct exposure can severely injure the human eye. For more information, see the User s Manual of the laser source in use. Turning off the power to the optical switch does not block the externally supplied radiation to the input of the optical switch, or the output of the optical switch. Information contained herein is deemed to be reliable and accurate as of issue date. EMCORE reserves the right to change this user manual, the design, or specifications of the product at any time without notice. EMCORE, and the EMCORE logo are trademarks of EMCORE Corporation. 14 of 14