Protection Products. Catalogue

Similar documents
Overcurrent and Arc Protection by Reyrolle Alexander Erokhin. 21, 2017 I Berlin

SOLKOR-N (7SR18) Feeder Differential Protection. Make the ight choice! Choose EYROLLE Protection

Reyrolle Catalogue Answers for Energy

7SG14 Duobias-M Transformer Protection

Substation Automation Products. Transformer protection RET670/650 Relion 670 and 650 series

Protection relays.

TWO-WINDING TRANSFORMER DIFFERENTIAL

PROTECTION, AUTOMATION & CONTROL

MiCOM P521. Fast feeder differential protection

MiCOM P521. Fast Feeder Differential Protection

7SR242 Duobias Transformer Protection Relay Answers for energy.

Recloser Controller for feeder protection and automation siemens.com/distribution-automation

Reyrolle Protection Devices. 7PG2113/4/5/6 Solkor Pilot Wire Current Differential Protection with integrated Overcurrent Guard. Answers for energy

(1) Description of Operation 7SR224 Recloser Controller

MiCOM P521. Fast Feeder Differential Protection. Protection Relays. MiCOM P521 CUSTOMER BENEFITS

7SR18 Solkor Line Differential Protection Energy Management

Current Matters. The Device issue. Siemens Protection Devices Ltd. In-depth looks at some of our best and most versatile products to date

7SR21 Non-Directional 7SR22 Directional Overcurrent Relay

Reyrolle Protection Devices. 7SR11 and 7SR12 Argus Overcurrent Relays. Answers for energy

Reyrolle Protection Devices. 7SR210 & 7SR220 Argus Overcurrent Protection Relay. Answers for energy

Transformer Protection and Control RET630 Numerical transformer protection in medium voltage networks

Reyrolle Protection Devices. 7SG13 Delta Protection and Control Relays. Answers for energy

Reyrolle Protection Devices. 7SR242 Duobias Transformer Protection Relay. Energy Management. Unrestricted

Substation Automation Products. Generator protection REG670/650 Relion 670 and 650 series

Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage

7SR11 and 7SR12 Argus Overcurrent Relays Answers for infrastructure & cities.

REL52002 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, RS-485

RMS Product Presentation

7SR242 Duobias Multi-Function 2-Winding Transformer Protection Relay

7SR21 Non-Directional 7SR22 Directional Overcurrent Relay

Transformer Protection Relay

SIPROTEC 7SC80 Feeder Protection and Automation Answers for infrastructure and cities.

Power systems 5: Protection

MiCOM P122C Time-Overcurrent Protection

7SR21 & 7SR22 Argus Overcurrent Relay Energy Management

Reyrolle Protection Devices. 7SR11 and 7SR12 Argus Overcurrent Relays. Answers for energy

DIGITAL RELAY OF PROTECTION AND AUTOMATION SERIES PC83 AND PC830

Catalog Edition 6 siemens.com/protection

7SR11 and 7SR12 Description of Operation

MiCOM P220, P225 and P226C

GRD110 FEATURES APPLICATION

Substation Automation Products. Line differential protection RED670 Relion 670 series

SYMAP R Plug in Variants FI, MI, 87M, TI Technical data

Feeder/ Motor Protection Relay VAMP 40

Substation Automation Products. Bay control REC670/650 Relion 670 and 650 series

7SR11 & 7SR12 Argus Overcurrent Relay Energy Management

7SR11 & 7SR12 Argus Overcurrent Relay Energy Management

SR489 SR489. Generator Management Relay. Economical protection, metering, and monitoring functions for small and medium sized generators.

IMP/ 001 / 014 Policy for the Protection of Distribution Networks

Substation Automation Products. High impedance differential busbar protection REB650 Relion 650 series

Relion 615 series Line Differential Protection and Control RED615 Ver. 2.0 Technical Presentation

RELAYABLE POWER. AQ 200 series protection, control, measurement and monitoring IEDs

RELAYABLE POWER. AQ 200 series protection, control, measurement and monitoring IEDs

Maximize protection. Sepam series 10, 20, 40, 60, 80. Modular range of digital protection relays

Protect induction and synchronous motors with one relay.

MiCOM P124 T&D. Self and Dual Powered Overcurrent Relays

p. 1 p. 9 p. 26 p. 56 p. 62 p. 68

7SR210 & 7SR220 Argus Overcurrent Protection Relay Energy Management

RELAYABLE POWER. AQ-200 series protection, control, measurement and monitoring IEDs

7SR210 & 7SR220 Argus Overcurrent Protection Relay Energy Management.

Relion 615 series Feeder Protection and Control REF615 Ver. 2.0 Technical Presentation

7SR11 and 7SR12 Argus Overcurrent Relays Energy Management

7SR191 Capa Capacitor Protection Relay Energy Management

APPLICATION AND COMMISSIONING MANUAL FOR NUMERICAL OVER CURRENT & EARTH FAULT PROTECTION RELAY TYPE MJT 315

DTRV-EP. COMPLEX DIGITAL PROTECTION FOR 120 kv / MEDIUM VOLTAGE TRANSFORMERS. Application field

Reyrolle Protection Devices. 7SG118 Argus 8 Voltage & Frequency Relay. Answers for energy

MiCOM P721 & P723. Numerical High Impedance Differential Relay. Protection Relays. Customer Benefits

Content REF615 Technical Presentation

S o m e t h i n g b e t t e r t h a n p r o t e c t i v e r e l a y s. automation, control & communication

GRE140. Protection and Control for MV Systems

Siemens Vacuum Recloser 3AD. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field

Substation Automation Products. Line distance protection REL670/650 Relion 670 and 650 series

MiCOM P14x. Feeder Management Relays

NEO 3000 Substation System THE FAMILY OF EQUIPMENT DEDICATED FOR POWER UTILITIES. Energy Sector

GE Multilin 350 Feeder Protection Relay Specifications

Siprotec 7ST61 / 7ST63

GRE120. Motor Protection and Control for MV Systems

REL52001 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, 2 x RJ-45

Approval...6. Current Revision...7. Introduction... 8 About PJM Manuals... 8 About This Manual... 8 Using This Manual...9

Reyrolle Protection Devices. 7SR10 Argus Overcurrent and Earth Fault Relay

Perfect protection smallest space

Protect induction and synchronous motors with one relay

Three phase and earth fault overcurrent relays

MiCOM P12x/y AREVA T&D. Three phase and earth fault overcurrent relays

System Protection and Control Subcommittee

MiCOM P14x AREVA T&D. Feeder Management Relays

Products Portfolio. Pole mounted Vacuum Recloser

7SR23 DAD High Impedance Protection Relay Energy Management

MiCOM Protection 20, 30 and 40 Series Relays Key Features

MiCOM Agile P541 & 542. Grid Solutions. High-speed current differential unit protection. Key Benefits. Key Features. Current Differential Protection

Relion 615 series Transformer Protection and Control RET615 Ver. 2.0 Technical Presentation

High-speed transformer differential protection for up to five terminals

Bus Bar Protection Relay B-PRO 4000

Reyrolle Protection Devices. 7SR10 Argus User Manual Overcurrent and Earth Fault Relay

CSC-211 Multifunction Protection IED Product Guide

UR Universal Relay Series

U lity network. system Q sys. Interconnected P sys. P load Q load. P gen Q gen. Generator network

AQ-200 SERIES PROTECTION,CONTROL, MEASUREMENT AND MONITORING IEDS

Medium Voltage Metal-Enclosed Thyristor-Switched Harmonic Filter Banks

Transcription:

Protection Products Numerical Multi-Function Relays Catalogue

Selection Guide Product Range Feeder Protection Model Argus 1 Argus 2 Argus 7 Argus 8 Delta Delta Lite Motor Protection Model Rho 3 Description Overcurrent and earth fault protection Directional overcurrent and earth fault protection Check synchronising relay Voltage & Frequency protection Feeder Manager Feeder Manager Description Motor protection Busbar Protection Model DAD - N Description High impedance differential protection Transformer Protection Model Duobias M Micro TAPP Description Transformer protection & automation system Automatic voltage control of transformers Feeder/Line Differential Protection Model Description Solkor - N Feeder differential protection, automation & control system

Feeder Protection ARGUS 1 Overcurrent and earth fault protection IDMTL phase overcurrent protection (51P) 3 DTL phase overcurrent protection (50P) IDMTL earth fault protection (51N) 3 DTL earth fault protection (50N) 2-stage circuit breaker failure (50BF) 2 instantaneous or DTL SEF/ REF stages with harmonic rejection (50N/64R) 8 independent setting groups Upto 9 programmable digital (status) input & upto 11 programmable output contacts CT supervision Circuit breaker maintenance Ammeter function Status & trip LEDs LCD display (16-characters, 2 lines) Fibre-Optic / RS485 Communication Port Communication protocol compatible with IEC 608-70-5-103 or MODBUS RTU Radial feeders Capacitor banks Industrial plants Transformers & Reactors Argus 1

Feeder Protection ARGUS 2 Bi-Directional overcurrent and earth fault protection IDMTL phase fault directional overcurrent protection (51/67) 3 DTL phase directional overcurrent protection (50/67) IDMTL voltage/current polarised directional earth fault protection (51N/67N) 3 DTL voltage/current polarised directional earth fault protection (50N/67N) 2- stage circuit breaker failure (50BF) 2 instantaneous or DTL SEF/ REF stages with harmonic rejection (50N/64R) Optional under/over voltage protection (27/59) Upto 9 programmable digital (status) input & upto 11 programmable output contacts CT supervision Circuit breaker maintenance Ammeter function (Complete metering function on specific models) Status & trip LEDs LCD display (16-characters, 2 lines) Fibre-Optic / RS485 Communication port Communication protocol compatible with IEC 608-70-5-103 or MODBUS RTU Parallel feeders Ring feeders Distribution feeders Transformers Argus 2

Feeder Protection ARGUS 7 Check synchronising relay Check & system synchronising (25) with independent settings Under voltage blocking Differential blocking Upto 4 programmable digital (status) inputs & upto 7 programmable output contacts Configurable dead bus and/or dead line charge Integral manual close guard feature Split system detection Close records Status & trip LEDs LCD display (16-characters, 2 lines) Fibre-Optic / RS485 Communication Port Communication protocol compatible with IEC 608-70-5-103 Check & system synchronising (25) Argus 7

Feeder Protection ARGUS 8 Voltage & Frequency protection Four independent voltage elements, each of which can be set as either under voltage (27) or over voltage (59) protection Negative sequence over voltage (47) protection Neutral voltage displacement protection Four independent frequency elements, each can be set for under frequency (81U) or over frequency (81O) protection 1, 2 or 3-phase measurement with four independent voltage elements Independent time delay for each element Upto 9 programmable digital (status) inputs & upto 11 programmable output contacts Circuit breaker maintenance Status & trip LEDs LCD display (16-characters, 2 lines) Fibre-Optic / RS485 Communication port Communication protocol compatible with IEC 608-70-5-103 or MODBUS RTU Capacitor bank Ungrounded / High impedance earthed systems AC Generators Transmission lines Distribution feeders Argus 8

Feeder Protection DELTA Feeder Manager Directional/Non-directional phase over current protection (50/51P, 67P) Directional/Non-directional derived earth fault protection (50/51N, 67N) Directional/Non-directional measured earth fault protection (50/51N, 67N) Sensitive earth fault/restricted earth fault protection (50N/64R/87G) Negative sequence over current protection (46IT+DT) Under/over voltage protection (27/59) Under/over frequency protection (81) Negative sequence over voltage protection (47) Neutral overvoltage protection (59NIT+NDT) Thermal overload protection (49) Check synchronisation (25) Cold load pickup Upto 27 programmable digital (status) inputs & upto 21 programmable output contacts Auto reclose (79) Broken conductor detection (46) Circuit breaker failure protection (50BF) Voltage transformer supervision Current transformer supervision Comprehensive metering functions Upto 32 programmable status and trip LEDs with text legend Mimic display Local/remote/out-of-service key switch Fibre-Optic and RS232 Communication port Communications protocol compatible with IEC 60870-5-103 or MODBUS RTU IRIG-B time synchronization Full programmable scheme logic using ReyLogic Integrated protection, control, monitoring & metering of distribution feeders Delta

Feeder Protection DELTA LITE Feeder Manager Directional/Non-directional phase over current protection (50/51P, 67P) Directional/Non-directional derived earth fault protection (50/51N, 67N) Directional/Non-directional measured earth fault protection (50/51N, 67N) Sensitive earth fault/restricted earth fault protection (50N/64R) Negative sequence over current protection (46IT+DT) Under/over voltage protection (27/59) Under/over frequency protection (81) Negative sequence over voltage protection (47) Neutral overvoltage protection (59NIT+NDT) Thermal overload protection (49) Check synchronisation (25) Cold load pickup Upto 27 programmable digital (status) inputs & upto 29 programmable output contacts Auto reclose (79) Broken conductor detection (46) Circuit breaker failure protection (50BF) Voltage transformer supervision Current transformer supervision Comprehensive metering functions Upto 32 programmable status and trip LEDs LCD display (20-characters, 2 lines) Fibre-Optic and RS232 Communication port Communications protocol compatible with IEC 60870-5-103 or MODBUS RTU IRIG-B time synchronization Programmable logic using Rey Logic Integrated protection, control, monitoring & metering of distribution feeders Delta Lite

Motor Protection RHO 3 Motor protection Thermal overload protection (49) Short circuit protection (50) Earth fault protection (50N) Stall and locked rotor protection (48) Phase unbalance protection (46) Undercurrent detection (37) Optional 8 thermistor or Resistance Temperature Detector (RTD) inputs Restart inhibit protection Limitation of number of starts Upto 9 programmable digital (status) inputs & upto 7 programmable output contacts CT supervision Earth fault trip inhibit for contactor control application Circuit breaker failure protection (50 BF) Comprehensive metering function Status and trip LEDs LCD display (16-characters, 2 lines) Fibre-Optic / RS485 Communication port Communications protocol compatible with IEC 60870-5-103 or MODBUS RTU Protection and management of medium and large motors and driven equipment Ideally suited for pumps, conveyors, compressors, fans etc. Rho 3

Impedance and Busbar Protection DAD N High impedance differential protection High impedance, phase segregated differential protection (87) Upto 27 programmable digital (status) inputs & Upto 29 programmable output contacts 3 analogue inputs Upto 8 setting groups Open circuit current transformer supervision Metering functions 16/32 programmable status and trip LEDs LCD display (16 characters, 2 lines) Fibre-Optic and RS232 Communication port Communications protocol compatible with IEC 60870-5-103 IRIG-B time synchronization Input characteristic rejects DC offset transients and provides excellent harmonic rejections Programmable logic using ReyLogic High impedance busbar protection with CT supervision DAD-N

Transformer Protection DUOBIAS M Transformer Protection & automation system Two-winding and three-winding power transformer, triple slope biased-differential protection (87) Second harmonic magnetising current inrush restraint Differential highset protection (87HS) IDMTL/DTL phase and ground overcurrent protection for HV and LV windings (50/51P, 50/51N) Thermal overload protection (49)* Neutral voltage displacement protection (59N)* Over and under voltage protection (27/59)* Under frequency protection (81)* Overexcitation protection Volts/frequency (24)* Integral restricted earth fault protection for each winding (64R) Upto 27 programmable digital (status) inputs & upto 29 programmable output contacts Circuit breaker failure protection (50BF)* Integrated current amplitude and vector group compensation which removes the needs for interposing CTs Comprehensive metering functions 16/32 status and trip LEDs LCD display (20 characters, 2 lines) Fibre-Optic and RS232 Communication port Communication protocols compatible with IEC-60870-5-103 and MODBUS RTU IRIG-B time synchronization Programmable logic using ReyLogic * These are optional functions Comprehensive protection, monitoring and control package for 2-winding and 3-winding power transformers Duobias M

Transformer Protection Micro TAPP Automatatic voltage control of transformers Automatic voltage control of power transformers through on-load tap changer Enhanced TAPP (Transformer automatic paralleling package) principle for voltage control User-specified system power factor eliminates errors associated with other circulating current schemes Load drop compensation Coupling control to minimise circulating current Tap-stagger to allow circulating current for network operation purposes Multiple settings groups to allow application of voltage offsets for load reduction and network operation Detection of low system frequencies to facilitate system voltage reduction by tapping down Homing feature enabling transformers to be tapped to the correct busbar voltage prior to switching in to or out of service Tap position indication accepts inputs from either analogue or numerical sender units Runaway prevention to lock out the tap-changer and prevent runaway due to electrical or mechanical failure VT Fuse monitor. Negative Phase Sequence (NPS) voltage element detects blown VT fuses to prevent incorrect voltage control Pseudo-VT Tm feature for voltage control on remote side of transformer Self monitoring Events, short-term waveforms and long-term system data recording I 2 counter Tap changer operations counter Tap position indicator Fibre-Optic / RS232 Communication port Communication protocol compatible with IEC 60870-5-103 LCD display (40 characters, 8 lines) Automatic voltage control & monitoring system of power transformers Voltage control on remote side of transformer for embedded generation, traction & induction furnaces Micro TAPP

Feeder/Line Differential Protection SOLKOR N Feeder differential protection, automation & control system Three pole current differential protection with two stage bias characteristic (87) Current differential protection Three pole, phase fault overcurrent protection - IDMTL or DTL with highsets (50/51P) Earth fault overcurrent protection - IDMTL or DTL with highsets (50/51N) Magnetising inrush detector to provide additional restraint Intertripping from internal or external initiation Upto 9 programmable digital (status) inputs & upto 7 programmable output contacts Ratio correction for mis-matched line current transformer ratios Communication link supervision Circuit breaker fail protection (50BF) I 2 counter Local & Remote current metering LCD display (16-characters, 2 lines) Fibre-Optic Communication port Communications protocol compatible with IEC-60870-5-103 Differential protection for overhead lines and cable feeders Solkor N

The policy of Easun Reyrolle is one of continuous improvement and development. The company therefore reserves the right to supply equipment, which may differ slightly from that described and illustrated in this publication. CORPORATE OFFICE Easun Reyrolle Limited., 98 Sipcot Industrial Complex Hosur 635 126, India. Tel: +91 4344 401600/01/02 Fax: +91 4344 276397 TURNKEY PROJECTS BUSINESS/AMR BUSINESS #389, Rasukumaki, Hulimavu Begur Hobli, Bannerghatta Road Bangalore - 560 076, India. Tel: +91 80 40477200/ 201 Fax: +91 80 40477202 Email: cenmarket@easunreyrolle.net Sales Offices Bangalore Easun Reyrolle Ltd. #17/3 Arakere, Bannerghatta Road, Bangalore - 560 076, India. Tel: +91 80 26581023/3268 Fax: +91 80 26580642 Email: blroffice@easunreyrolle.net Kolkata Easun Reyrolle Ltd. 4, Dr.Sundari Mohan Avenue, 5th Floor Flat No.18, Kolkata - 700 014, India. Tel: +91 33 22848320 Fax: +91 33 22848326 Email: kolkata@easunreyrolle.net HOSUR WORKS #98, Sipcot Industrial Complex Hosur - 635 126, India. Tel: +91 4344 401600/01/02 Fax: +91 4344 276397 CENTRAL MARKETING & EXPORTS BUSINESS #17/3 Arakere Bannerghatta Road Bangalore - 560 076, India. Tel: +91 80 26581023/3268 Fax: +91 80 26580642 Email: cenmarket@easunreyrolle.net Bhopal Easun Reyrolle Ltd. H.No.16, Essarjee Homes Near Gopal Nagar, Kalan Road Piplani, Bhopal - 462 021, India. Telefax: +91 755 2684221 Email: bhopal@easunreyrolle.net Mumbai Easun Reyrolle Ltd. 23, Kasturi Building, Jamshedji Tata Road Mumbai - 400 020, India. Tel: +91 22 22022270/22855415 Fax: +91 22 22825703 Email: mumbai@easunreyrolle.net BANGALORE WORKS #17/3 Arakere, Bannerghatta Road Bangalore - 560 076, India. Tel: +91 80 26581023/3268 Fax: +91 80 26580642 Email: blrworks@easunreyrolle.net AUTOMATION BUSINESS #389, Rasukumaki, Hulimavu Begur Hobli, Bannerghatta Road Bangalore - 560 076, India. Tel: +91 80 40477200/ 201 Fax: +91 80 40477202 Email: smabp@easunreyrolle.net Chennai Easun Reyrolle Ltd. 6th Floor, Temple Tower, 672, Anna Salai, Nandanam Chennai - 600 035, India. Tel: +91 44 24346425/24347608 Fax: +91 44 24346435 Email: chennai@easunreyrolle.net Secunderabad Easun Reyrolle Ltd. #2, 1st Floor, Paradise Chambers Opp Hotel Ambassador 1-7-196 Prender Ghast Road Secunderabad - 500 003, India. Telefax: +91 40 27817847 Email: hyderabad@easunreyrolle.net Delhi Easun Reyrolle Ltd. 29/12, Ground Floor, East Patel Nagar New Delhi - 110 008, India. Tel: +91 11 25747321/25747322 Fax: +91 11 25747320 Email: delhi@easunreyrolle.net Corporate Office Easun Reyrolle Limited. 98 Sipcot Industrial Complex, Hosur 635 126 India. Tel: +91 4344 401600/01/02 Fax: +91 4344 276397 www.easunreyrolle.com CAT/PPMF/08-07/Rev 1 IMAGIC CREATIVES Easun Reyrolle-2007 - Easun Reyrolle, the Easun Reyrolle logo and any alternative version thereof are registered trade marks and service marks of Easun Reyrolle