GE 800. Digital IP-Intercom Server GE 800. Datasheet

Similar documents
GE 800. Digital IP-Intercom Server GE 800 DATASHEET

IP DSP-Intercom Stations Series EE 900A

SIP-ET 908A. SIP Module SIP-ET 908A. Datasheet

2-Wire Industrial Station Series 8000

WS 201PICA. IP Wallmount Station WS 201PICA. Datasheet

Control Desk solutions by Commend. CONDUCTOR Simplicity in concert with Power.

Compact Intercom Server GE 100

Intercom Client for Android The IP Intercom Station with a special touch

SIP-WS 201VCA. Wallmount Stations SIP-WS 201VCA. Datasheet

ET 908. IP-Intercom Module ET 908 DATASHEET PRELIMINARY

S6 High performance Intercom Server for rack mounting

Business internet start, Business internet comfort, Business internet max giga. Internet can also be purchased separately without voice.

MINUTES AND TEXTS CUSTOMER MOBILE BOLT-ON GUIDE JUNE 2018 BOLT-ON WILL KEEP YOU IN CONTROL OF YOUR COSTS. INTERNATIONAL NUMBERS FROM YOUR MOBILE, THIS

E-T-A PowerPlex Bus System for Marine Applications

DATA SHEET. Catalyst Inline Power Patch Panel

IP Desktop Intercom Stations 12 NIB 001 Series

SpectraGuard Sensor SS-300-AT-C-50 Technical Specifications

Automation DriveServer

FP-PS-4. Features. Installation

Field Terminal Assembly (FTA)

RT-AX95U Wireless-AX11000 Tri Band Gigabit Router

Traffic Offload. Cisco 7200/Cisco 7500 APPLICATION NOTE

Map Reconfiguration User Guide

AC/DC (120V) Input Module Cat. No IAD Series C

Agilent 66000A 1200 W DC Modular Power System, GPIB

Instructions. (For 6180 Industrial Computers) Installing a Processor Upgrade

E-Seminar. Voice over IP. Internet Technical Solution Seminar

4 GHz Active Probe P7240 Datasheet

Connected for less around the world Swisscom lowers its roaming tariffs again. Media teleconference 12 May 2009

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9871E

CISCO 7304 SERIES ROUTER PORT ADAPTER CARRIER CARD

Beckhoff short profile

DataKom Vodafone Mobile Tariff Minimum 30 day end of month notice cancellation - Subject to contract. DataKom O2 Mobile Tariff. All prices exclude VAT

Tektronix Logic Analyzer Probes P5900 Series Datasheet

CISCO IP PHONE 7970G NEW! CISCO IP PHONE 7905G AND 7912G XML

Map Reconfiguration Dealer Guide

4 GHz Active Probe P7240 Datasheet

Monitoring products K8 SERIES. C o m p l e t e r a n g e i n m m w i d e h o u s i n g. Advanced Industrial Automation

THE NEW RC8. English. Connect to many devices such as... PLCs. Cameras Grippers...and many more.

END-OF-SALE AND END-OF-LIFE ANNOUNCEMENT FOR THE CISCO MEDIA CONVERGENCE SERVER 7845H-2400

Cisco ONS SDH 12-Port STM-1 Electrical Interface Card

Cisco CallManager 4.0-PBX Interoperability: Lucent/Avaya Definity G3 MV1.3 PBX using 6608-T1 PRI NI2 with MGCP

6640A Series Single-Output, 200 W DC Power Supplies, GPIB

Patent Portfolio Overview July The data in this presentation is current as of this date.

Patent Portfolio Overview May The data in this presentation is current as of this date.

Service withdrawal: Selected IBM ServicePac offerings

IP-Bridge Module for establishing IP connections in 2-wire-based cablings

Agilent U2941A Parametric Test Fixture

Instructions. (For 6180 Industrial Computers) Applications. Overview & Safety

Agilent U8000 Series Single Output DC Power Supplies. Data Sheet

NI 6521 Specifications

S6 High performance Intercom Server for rack mounting

AP 701 Access Panel. Features and Functions

ThinkServer IBM Tape Options

Keysight Technologies 8163B Lightwave Multimeter 8164B Lightwave Measurement System 8166B Lightwave Multichannel System.

Enterprise price plan guide Vodafone One Net Business

animeo IB+ Motor Controller WM 4DC/E

Avaya P332MF. Quick Start Guide. Unpack 1. Rack mount (optional) 2. Power up 3. Connect the Cables 4. Configure 5. Run Web-based Manager (optional)

E-T-A Get Smart With Your Systems

Calibrating FieldPoint Analog Input Modules with Calibration Executive

Kapsch CarrierCom. We drive innovation to drive your business.

Building-block power supply with system back-up options S8TS SERIES

ISV/TP Enrolment Form

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9870E

Allen-Bradley 1397 Enhanced Field Supply Card Cat. Nos FS FS1020

ENHANCED INTERIOR GATEWAY ROUTING PROTOCOL STUB ROUTER FUNCTIONALITY

A B A B. (Catalog Number 2707-MVH232, -MVP232) Product Data

Process displays For current and voltage

Agilent N4880A Reference Clock Multiplier

OUR SHARERS MEAN BUSINESS. SHARER TARIFF RANGE CUSTOMER MOBILE TARIFF GUIDE JUNE 2018

IBM offers Software Maintenance for additional Licensed Program Products

MORE THAN JUST A PRODUCT, CABLOFIL IS A GLOBAL SOLUTION. Safer, more economic economic and more performant and A SYSTEM AN EXPERTISE A SERVICE

CISCO AC/DC POWER SOLUTION FOR USE WITH CISCO OPTICAL PLATFORMS

8510 AC Spindle Drive Hardware/Firmware Replacement

Step 1: New Portal User User ID Created Using IdentityIQ (IIQ)

Advanced Test Equipment Rentals ATEC (2832)

IGEL-Briefing March Managed Software and Hardware Thin Clients

FP-AO-200 AND CFP-AO-200

SF5x Series DO-201AD. Page <1> 26/07/08 V1.1. Dimensions : Inches (Millimetres)

Installation Note. Removable Hard Disk Drive Upgrade Kit. For All PNA Series RF Network Analyzers. Network Analyzer Model Number

High-Performance Differential Probes P7350 P7330 P6330 Datasheet

FieldPoint. FP-1000/1001 FieldPoint Quick Start Guide. Install the Network Module Mount the module on a DIN rail. What You Need to Get Set Up

Business Mobile Plans

Agilent E36XXA Series Non-Programmable DC Power Supplies. Data Sheet

CLASS 1 DIVISION 2 PRODUCTS

Quick Start Guide TP1692EN Issue 3

FP-AO-210 AND CFP-AO-210

TS8000. DeviceNet Option 8000/DN/00 HA Issue 1

Priva Blue ID C-Line system overview

The pricing guide. What are these prices?

Global entertainment and media outlook Explore the content and tools

BUSINESS CUSTOMERS MORE FLEXIBILITY, CUSTOMER MOBILE TARIFF GUIDE MORE CHOICE EXPECT MORE MORE DATA, NOVEMBER 2018

Differential Probes TDP1500 TDP3500 Data Sheet

BUSINESS CUSTOMERS MORE FLEXIBILITY, CUSTOMER MOBILE TARIFF GUIDE MORE CHOICE EXPECT MORE MORE DATA, APRIL 2018

SPC4320. SPC G2 Intrusion System

NI CB-37F-LP. Introduction INSTALLATION GUIDE. Connector Block for 37-Pin D-Sub Devices

Global Intercom Hardware

Keysight Technologies E4980A Precision LCR Meter 20 Hz to 2 MHz. E4980AL Precision LCR Meter 20 Hz to 300 khz/500 khz/1 MHz. Configuration Guide

Agilent U2751A USB Modular Switch Matrix. Data Sheet

Cisco Unified CallManager 4.0-PBX Interoperability: Mitel 3300 ICP Release 4.1 PBX to a Cisco 6608 Gateway using T1 QSIG with MGCP

Transcription:

Datasheet Digital IP-Intercom Server Both the hardware and the software concept of the Intercom Servers incorporates state-of-the-art technology. All digital and with distributed intelligence the Intercom Server administers up to 112 IP-subscribers (or 56 digital or 56 analog). Interaction of all the peripheral devices and cards is controlled by a central processing unit. Each plug-in card or interface has its own front-end processor for controlling its particular features and facilities. The operating system of the is programmed using the latest, object-orientated software. This means that all present and future requirements in the fields of Intercom systems, security systems, facilities management, etc. can be met - fully digitally and on a IP-basis. Basic housing including transformer for power supply (depending on version), with bus pcb for 17 plug-in slots: processor card, connection card, power supply card, slot 1 to 14 available for subscriber cards (up to 112 subscribers) and/or interface cards. The Intercom Server unit includes an AF input for music/alarm, 2 inputs for floating contacts, 2 relay outputs and two Ethernet sockets and one RS 232 socket for (remote) configuration or maintenance. Datasheet Version 2.3/0414 Errors and omissions excepted Products may change in the interest of technical improvements without notice. www.commend.com P 1 8

Technical Data Benefits Technical data AC power supply: 24 V +/- 5% / 80 VA DC power supply: 24 35 V / 80 W Emergency power consumption: 200 mah for G8-GEN, G8-NET, G8-GEP, G8-GEB other cards: see corresponding data sheet Frequency range: 50 Hz to 16 khz Operating temperature range: 0 C to +50 C (32 F to 122 F) Storage temperature range: 30 C to +60 C ( 22 F to 140 F) Relative humidity: 20% to 80% not condensing Measurements of the housing: 483 x 133 x 229 mm (19.03 x 5.24 x 9.02 inch) Weight including package: approx. 5,800 g (12.8 lbs) Mounting: 19, 3 HU Relay outputs: max. switching capacity: 60 W / 125 VA, max. switching current: 2A max. switching voltage: 60 VDC / 40 VAC Music input: max. 800 mv rms at 10 kω, 16 khz Inputs IN1, IN2: for floating contacts, max. line resistance: 1.5 kω Thermal dissipation loss: 45.2 W (for calculation of the thermal load) Benefits Digital IP-Intercom Server (voice, video, indication and control). Integration of other systems via Ethernet and V24 interfaces with own protocol converter. The Server housing and connecting technology is specially designed to the requirements of 19 racks. More than 150 standard features Latest intercom technology: microprocessor-controlled, high density design, SMD production, object-orientated programming. For all kinds of Intercom stations (IP, 2-wire and 4-wire). Digital networking over IP, 2 or 4-wire lines, E1 or ISDN. Non-blocking Integrated functions for door/gate control, alarms, conferences and central control desks. Plug&Play video integration. Expandable from 2 to max. 25,000 subscribers without restrictions (up to 30,000 subscribers with restrictions). User-friendly configuration with included PC software. Expansion Subscriber: Outputs: Inputs: Basic expansion: 0 2 2 Maximum expansion per Server housing: Maximum expansion (239 housings) 112 226 226 30,000 (incl. WAN) 50,000 50,000 Extent of Supply 1 Intercom Server including: 19 housing (3 height units) with snap-on lid G8-GEB Bus PCB (with 17 slots, of which 14 are empty) G8-GEN power supply card (incl. installation board G8A-GEN) G8-GEP processor card G8-NET connection card (incl. installation board G8A-NET, 1m / 3.3ft cable) network requirements G8-NET QoS Requirements Maximum One-Way-Delay 100 ms Delay-Jitter not above 50 ms 0% packet loss for perfect audio quality Depending on variant: Transformer incl. mounting set for DIN rail TS 35 Tool for removing of installation boards Bandwidth Required Bandwidth incl. protocol overhead, for upload/ download each: speech and data 96 kbit/s Speech is compressed according to G.722 standard Datasheet Version 2.3/0414 Errors and omissions excepted Products may change in the interest of technical improvements without notice. www.commend.com P 2 8

Precautions This is a Class A product (standard EN 55022). In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. Defective power cables of the transformer must not be repaired or changed. In case of defective power cables, the whole transformer has to be changed. Mounting and installation of the Intercom Server and of the equipment may be carried out only by authorised service personnel. Cards may be inserted and removed only with voltage switched off. Before exchanging of cards, ESD precautions must be observed. The Earth terminal of the installation board G8A-GEN (see Connection Diagram G8A-GEN ) is used as grounding point for Wrist Strap Grounding. If heavy electromagnetic interference is to be expected (industrial environments), then grounding of the Intercom Server is mandatory. Configuration via IP The IP-Addresses of the Intercom Server are defined with the DIP-switches of the G8-GEP. As soon as the Intercom Servers are connected with the network they can be configured via IP. Configuration via RS 232 For configuration of the a 9-way D-Submin connection cable is required (1:1, plug on Server side, socket on PC side). This cable is connected to the 9-way D-Submin socket on the front of the power supply card G8-GEN or on the installation board G8A-GEN. NC 1 1 TXD 2 2 RXD 3 3 NC 4 4 GND 5 5 NC 6 6 NC 7 7 NC 8 8 NC 9 9 (9-way D-Submin plug) (9-way D-submin jack) PC NC = not connected This cable can be purchased at an electric outfitter or ordered under the type X-KAB-CCT. Mounting Instructions One housing requires 3 height units The plug-in cards are inserted into the 19 housing from the front and fixed with the attachment-clips. The corresponding installation boards are mounted at the rear of the Intercom Server (see Mounting of Cards and Boards ). Mounting of Cards and Boards boards Plug-in cards Tool for removing of installation boards Datasheet Version 2.3/0414 Errors and omissions excepted Products may change in the interest of technical improvements without notice. www.commend.com P 3 8

Connection Diagram G8A-GEN The G8A-GEN is the installation board for the card power supply card G8-GEN and the processor card G8-GEP. Connection Diagram G8A-NET G8A-NET is the installation board for the card G8-NET. Music / alarm input Floating contacts e.g.: Door opener Power supply S1W S1 S2W S2 Wiring outputs MU1 MU2 IN1 IN2 G8A-GEN S1 S2 S1W S1 S2W S2 +30V 24V AC 24V AC Grounding DC or AC 1 2 3 4 5 6 7 8 9 1...GND (Shield) 2...TXD 3...RXD 4...NC 5...GND 6...NC 7...NC 8...NC 9...NC Programming socket (parallel to G8-GEN) Power supply Grounding point for wrist strap grounding UPLINK DOWNLINK OUT (GEV) IN (GEV) Ethernet (configuration) Connection to network cards (G8-CNET-W, G8-CNET-E1) or GE 700 (G7-GEV) Datasheet Version 2.3/0414 Errors and omissions excepted Products may change in the interest of technical improvements without notice. www.commend.com P 4 8

Plug-in Cards for Subscriber cards: G8-IP-4B, C, D, P: for four IP-stations G8-IP-8B, C, D, P: for eight IP-stations G8-GED-4B, C, D: for four digital intercom stations G8-GET-4B, C, D: for four analogue intercom stations G8-TEL-4C, D: for four analogue telephones Input/output cards: G8-8E8A: 8 inputs for floating (volt-free) contacts and 8 floating (volt-free) relay contacts G8-16A: 16 outputs (floating (volt-free) relay contacts) G8-16E: 16 inputs for floating (volt-free) contacts Interface cards: G8-V24-PRO: Programmable V24-card with two RS 232-interfaces, of which one can be configured as RS 422. Attention: The card works with separately available driver software only! G8-AUD-2B, C, D: Digital Audio-Recording-Card with two audio channels (IN/OUT) and four relay contacts. G8-AUD-4B, C, D: Digital Audio-Recording-Card with four audio channels (IN/OUT) and four relay contacts. G8-TEL: Analogue telephone interface for connection to a PABX or the public telephone network. G8-SELCALL: Radio interface (two slots of the are occupied by the G8-SELCALL and the enclosed G8-V24-PRO!) G8-IAX: Interface card for integration of various VoIP-Standards via a IAX-capable Asterisk server. G8-VOIPSERV: Server card on Linux and Asterisk basis allows integration of various VoIP-Standards such as SIP, H.323 oder SCCP directly in the Intercom Server. G8-IF: Ethernet Interface card with standard ICX-protocol via Ethernet and two RS 232 Connection cards: G8-LAN: IP network card for connection of up to 100 Intercom Servers, GE 700, GE 300 and GE 200 via Ethernet (corresponding to IP protocol). G8-CNET-E1: E1 network card for connection of up to 100 Intercom Servers, GE 700, GE 300 and GE 200 over multiplexer connections or media converter, like e.g. fibre optic. G8-CNET-W: Network card for connection of up to 100 Intercom Servers, GE 700, GE 300 and GE 200 over 2 wires up to 4 km (2.48 miles). G8-S0: Network card for connection of up to 100 Intercom Servers, GE 700, GE 300 and GE 200 over ISDN dial up connections (two ISDN-basic rate interfaces). Licences For Subscriber Licences: L8-SUB-28C: For feature level upgrade from B to C for 28 subscribers. L8-SUB-28D: For feature level upgrade from B to D for 28 subscribers. Networking Licences: L8-NETLAN4: For activation of 4 LAN-connections via G8-NET card. L8-NETLAN8: For activation of 8 LAN-connections via G8-NET card. L8-NETWAN4: For activation of 4 WAN-connections via G8-NET card. L8-NETWAN8: For activation of 8 WAN-connections via G8-NET card. Interface Licences: L8-ICX: For activation of one ICX-Interface (ICX/TCP or ICX/RS232). Datasheet Version 2.3/0414 Errors and omissions excepted Products may change in the interest of technical improvements without notice. www.commend.com P 5 8

Plug-in Positions of the Cards The plug-in cards can be inserted in the following slots: Card type GEN GEP 1 2 3 4 5 6 7 8 9 10 11 12 13 14 NET max. per Server G8-16A 3 - - - 14 3 G8-16E - - - 14 G8-8E8A 3 - - - 14 3 G8-CNET-E1 - - - - - - - - - - 5 G8-LAN - - - - - - - - - - 7 G8-CNET-W - - - - - - - - - - 5 G8-AUD - - - 14 G8-IAX - - - 14 G8-IF - - - 14 G8-IP - - - 14 G8-TEL4 1 - - - - - - - - - - 2 1 G8-GED - - - 14 G8-GEN - - - - - - - - - - - - - - - - 1 G8-GEP - - - - - - - - - - - - - - - - 1 G8-GET - - - 14 G8-NET - - - - - - - - - - - - - - - - 1 G8-S0 - - - 7 G8-SELCALL 2 - - 4 2 G8-TEL - - - 14 G8-V24-PRO - - - 14 G8-VOIPSERV - - - 6 1 Details see datasheet G8-TEL4 2 A second slot of the is occupied by the G8-V24-PRO delivered with the G8-SELCALL. 3 A maximum of 100 outputs may be activated at once. Datasheet Version 2.3/0414 Errors and omissions excepted Products may change in the interest of technical improvements without notice. www.commend.com P 6 8

boards for the Plug-in Cards The plug-in cards can be used with the following installation boards:...included in extent of supply...available separately X...via Ethernet sockets of Intercom Server (G8A-NET) G8A-C G8A-I G8A-K G8A-T G8A-V24 G8A-GEN G8A-NET G8A-TEL G8A-PRO G8A-EW G8-16A - - - - - - - - G8-16E - - - - - - - - G8-8E8A - - - - - - - - G8-CNET-E1 - - - - - - - - - G8-LAN - - - - - - X - - - G8-CNET-W - - - - - - - - - G8-AUD * * - - - - - - G8-IAX - - - - - - X - - - G8-IF - - - - - X - - - G8-IP - - - - - - X - - - G8-TEL4 - - - - - - - - G8-GED - - - - - - G8-GEN - - - - - - - - - G8-GEP - - - - - - X - - - G8-GET - - - - - - G8-NET - - - - - - - - - G8-S0 - - - - - - - - - G8-SELCALL - - - - - - - - - G8-TEL - - - - - - - - - G8-V24-PRO - - - - - - - - - G8-VOIPSERV - - - - - - X - - * When using the installation boards G8A-C or G8A-T the 4 relay contacts of the G8-AUD can not be connected! Datasheet Version 2.3/0414 Errors and omissions excepted Products may change in the interest of technical improvements without notice. www.commend.com P 7 8

COMMEND A Strong Network Worldwide Europe America SWITZERLAND LIECHTENSTEIN Commend AG Tel. +41-44-955 02 22 www.commend.ch USA CANADA LATIN AMERICA Commend Inc. Tel. +1-201-529-2425 www.commendusa.com FRANCE Commend France S.A.S. Tel. +33-149 18 16 40 www.commend.fr SPAIN PORTUGAL ITALY Commend Ibérica S.L. Tel. +34-91-395 24 98 www.commend.es Commend Italia S.R.L. Tel. +39-035-95 39 63 www.commend.it Asia-Pacific AUSTRALIA NEW ZEALAND Commend Australia Tel. +61-3-9729-3700 (Melbourne) Tel. +61-2-4655-5738 (Sydney) www.commend.com.au NETHERLANDS BELGIUM LUXEMBURG AUSTRIA SLOVENIA RUSSIA HUNGARY CROATIA SERBIA BOSNIA-HERZEGOVINA MONTENEGRO MACEDONIA KOSOVO ALBANIA Commend Benelux B.V. Tel. +31-76-200 01 00 www.commend.nl Commend Österreich GmbH Tel. +43-1-715 30 79 www.commend.at Commend Adria d.o.o. Tel. +385-1-369 11 23 www.commend.hr CHINA SINGAPORE ISRAEL Commend Business Hub China Tel. +86-21-52 13 19 28 www.commend.cn Commend Business Hub Asia Isolectra Far East Pte. Ltd Tel. +65-6272-2371 www.commend.com.sg Sberlophone Ltd Tel. + 972-4-834 10 32 www.sberlophone.co.il SLOVAKIA CZECH REPUBLIC Commend Slovakia spol. s r.o. Tel. +421-2-58 10 10 40 www.commend.sk Africa UNITED KINGDOM IRELAND SWEDEN NORWAY FINLAND DENMARK ICELAND Commend UK Ltd Tel. +44-1279-87 20 20 www.commend.co.uk Commend Business Hub Nordic JNT Sound System AB Tel. +46-8-99 30 60 www.jnt.se SOUTH AFRICA ALGERIA TUNISIA MOROCCO Commend Business Hub South Africa Evolving Management Solutions (Pty) Ltd Tel. +27-11-274 6665 www.commend.co.za Commend France S.A.S. Tel. +33-149 18 16 40 www.commend.fr POLAND C&C Partners Telecom Sp.z o.o. Tel. +48-65-525 55 55 www.ccpartners.pl Other countries GERMANY Schneider Intercom GmbH Tel. +49-211-88285-333 www.schneider-intercom.de Commend International GmbH Tel. +43-662-85 62 25 www.commend.com Datasheet Version 2.3/0414 Errors and omissions excepted Products may change in the interest of technical improvements without notice. www.commend.com P 8 8