Shutter Assembly Guide Frame Accessory

Similar documents
Test Kit, Communication Adapter, Power Supply Dispositivo de prueba Pocket de test pour

COOPER POWER SERIES. Input/Output (I/O) module installation instructions. Voltage Regulators MN225067EN

COM32. Installation & Operation Manual

COOPER POWER SERIES. RS-485 digital communications accessory board installation and operation instructions. Voltage Regulators MN225074EN

COOPER POWER SERIES. Visible-Break switch accessory operation instructions. Padmounted switchgear MN285011EN

COOPER POWER SERIES. 600 A U-OP visible break connector system operation instructions. Deadbreak Apparatus Connectors MN650022EN

SIMADYN D Digital Control System. Fiber-Optic Rack Coupling CS12. User Manual. Edition DK No

It's Here... Access Elevator Supply now offers Replacement Logic Boards for Siemens Class 72G Elevator Soft Starters. Easy to install and lightweight

User Guide usa.siemens.com/smartgear

COOPER POWER SERIES. Fiber-optic/RS-232 communications module installation and operation instructions. Voltage Regulators MN225020EN

EMMS-T A00 SIERS. Siemens integrated electrical racking system instruction manual. usa.siemens.com/mvswitchgear

Conext CL-60 Inverter Firmware Upgrade Process

Lug Mounting Assembly Adaptador de Montaje de Borne Adapteur Support de Crochets

COOPER POWER SERIES. Ethernet communications module installation and operation instructions. Voltage Regulators MN225033EN

Shutter and rail locking device for low-voltage switchgear

MFKF3R 3VL9300-3JM01 MFKF43R 3VL9300-3JM41 MFCF036 3VL9300-3JQ31 MFCF048 3VL9300-3JQ41

MFMM 3VL9600-3JN01 MFKL3R 3VL9400-3JM01 MFKM3R 3VL9600-3JM01 MFCM036 3VL9600-3JQ31 MFCM048 3VL9600-3JQ41

Vista SD Portable Remote Control Pendant

SEM3 - Embedded Micro Metering Module

Single Phase Vacuum Capacitor Switch. UltraVacLT 15kV 95kV or 125kV BIL

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

COM128. Installation & Operation Manual

Door Mount Rotary Handle Operator Accionamiento Giratorio de Montaje en la Puerta Mise en marche giratoire d'assemblage dans la porte

Configuration. S&C Scada-Mate Switching System Outdoor Distribution (14.4 kv through 34.5 kv)

Installation. MGE Galaxy 3500 and Smart-UPS VT. Maintenance Bypass, Distribution and Transformer Cabinet

PowerLogic High Density Metering System 1-Meter Enclosure

KBMG MULTI-SPEED BOARD

COOPER POWER SERIES. DC motor operator control installation and operation instructions. Padmounted Switchgear MN285018EN

Series 3700 Screw Terminal Assemblies Installation Instructions

Series NRX drawout circuit breaker and cassette rejection interlocks

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Model 2380 Rack-Mount Kit

SAVE THESE INSTRUCTIONS

PowerFlex 755 Common DC Input Drives, Frames Interlock Assembly and Precharge Assembly Left-front Cover Retrofit Kit

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

Installation and Operation

Agilent Technologies E5385A 100-Pin Probe

Installation NOTICE. S&C IntelliCap Automatic Capacitor Control. Table of Contents. Instruction Sheet

ATV Single Gang Disc Harrow OWNER S MANUAL

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

Digitrip 520MC with Maintenance Mode

Installation Manual. SENTRON 3/6 Bus Plug with Optional SEM3 Package. usa.siemens.com/busway

Installation Instructions

* * Agilent Power Distribution Unit (PDU) Installation Guide

Installation Guide SMT 2200/3000 VA Input/Output Hardwire Kit

CONTACTOR DRIVER BOARD. DS200CDBAG1A and DS200CDBAG1B

Altivar 61/71 Adjustable Speed Drives Heatsink Fan Kits VZ3V1212 and VZ3V1216

ATV Single Row Disc Harrow OWNER S MANUAL

S Reclosers. Contents. Form 6 Recloser Control Disassembly, Reassembly, and Testing Instructions

110.4 Use of Equipment.

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

Digital encoder interface module 5/12/24 V DANGER

PIM-Mini Pulsed Current Source Operation Manual

Install Motor Controller User Manual

DTU3005-B Intelligent Data Transfer Device for Connection to PLCs and Modbus Networks Operator s Manual

Enphase S-Series Microinverter and Engage Cable Safety

SLM Series Slot Sensors

Primary Injection Test Procedure

Model 2380 Rack-Mount Kit

Agilent Technologies E5346A 38-Pin Probe and E5351A 38-Pin Adapter Cable

Type VR Electrically Operated Ground and Test Device

Voltage Detector and Phasing Tester Operating Instructions 83280

Installing the NEMA 4X Hatch

Installation and Operation Guide for PD5200 and PD5300 Automatic Transfer Switch

Adapter Kit for PanelView 1200/1200e Touch Screen Terminal Cutout

TDM-150 TIMER DISPLAY

MPP200 User s Manual

SKIVING MACHINE MAINTENANCE & INSTRUCTIONS MANUAL ASSK2. Allswage UK. Roebuck Street, West Bromwich, B70 6RB

Series Amp Pad Mount Quick Connect Input and Output Power Panels

COOPER POWER SERIES. Form 4C microprocessor-based recloser control standard and automation power supply kit installation and operation instructions

WinPM.Net 6.0. Installation Guide

SIWAREX JB Aluminum Housing. Instruction Manual Edition 03/2006

ACCESS 9340/9360 Meter Input/Output Module

VM 6.1. Capacitive Air Gap Measuring Chains User s Manual P/N: M7A-110

INCOM communications adapter module

WARNING ELECTRICAL SHOCK HAZARD

Multi Unit Enclosed Meter

Altivar - Lexium. Option modules DANGER S1A S1A /8 VW3A3601 / VW3A3608 VW3A3616 / VW3A3627 VW3A3619 VW3A3720 VW3A3721 VW3M3308

A1. Multilin EPM 4600 Meter Displays DIS3500/DIS5700. Quick Start Guide. GE Digital Energy

B63/ NS MS. EtherNet/IP LINK

1.4. Electronic Products. Contents Description E33 esm Keypad Multiplexed Switch Module Product Selection...

36'' & 48'' E-Z Shutter Fan Installation & Operator s Instruction Manual

Articulating TV/Monitor Clamp/Grommet Desk Mount Model: DE640S (Hydro Series)

INSTALLATION INSTRUCTIONS

Trusted Power Distribution Unit 15-Way Fused

Agilent Technologies E5339A 38-Pin Low-Voltage Probe

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

OV1000 Part No OV1000 HEIGHT ADJUSTABLE TABLE USER GUIDE

Instruction Manual: IM E

Wall. No opening (Example: LA-030-W)

GV3000/SE AC Drive ControlNet Network Communication Option Board M/N 2CN3000

M215 (M215-60) Safety

INSTALLATION INSTRUCTIONS STZ-R SERIES (ENGLISH)

Installation Note. Enhanced Memory Upgrade Kit (Option B72) for Agilent ESA-E Series and ESA-L Series Spectrum Analyzers

MK-212 SERIES OWNERS MANUAL & OPERATING INSTRUCTIONS

Access Energy Manager (AEM) Sub Billing Software 2.0. Commissioning & Operations Guide

PCM-7140 Pulsed Current Source Operation Manual

Instruction Bulletin Trim and Rail Extension Kit (6-, 12-, and 18-inch) Installation onto an NF Panelboard Class 1670

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

FX Supervisory Controller Wireless TEC Option Card Installation Instructions

Transcription:

Shutter Assembly Guide Frame Accessory SIZE: FS1 3-pole Cat. No.: WLG3SHUT1L For Use With: Circuit Breaker Adapters WLG _ 13 Installation Instructions Instruction No.: 923 99902 176 Danger Peligro Danger! Hazardous Voltage Will cause death or serious injury. Tensión peligrosa. Pueda causar la muerte o lesiones graves. Tension dangereuse. Danger de mort ou risque de blessures graves. WARNING Shock and arc flash hazard May cause serious injury or death. Only qualified personnel should work on this equipment, after becoming thoroughly familiar with all warnings, safety notices, and maintenance procedures contained herein and on the devices. For the purposes of this manual and product labels, qualified personnel is one who is familiar with the installation, construction, or operation of the equipment and the hazards involved. In addition, s/he has the following qualifications: (a) is trained and authorized to energize, de-energize, clear, ground, and tag circuits and equipment in accordance with established safety practices. (b) is trained in the proper care and use of protective gear equipment such as rubber gloves, hard hat, safety glasses or face shields, flash clothing, etc., in accordance with established safety procedures (c) is trained in rendering first aid. Only authorized repair or replacement parts shall be used in this equipment. 923 99902 176 1 / 8

NOTICE These instructions do not purport to cover all details or variations in equipment, nor to provide for every possible contingency to be met in connection with installation, operation or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the Purchaser s s purposes, the matter should be referred to the local Siemens Sales Office. The contents of this instruction manual shall not become part of or modify any prior or existing agreement, commitment or relationship. The sales contract contains the entire obligations of Siemens. The warranty contained in the contract between the parties is the sole warranty of Siemens. Any statements contained herein do not create new warranties or modify the existing warranty. TRADEMARKS Unless otherwise noted, all names identified by are registered trademarks of Siemens AG or Siemens Industry, Inc. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. The following is the bill of materials and tools required to assemble shutter for frame size 1. Bill of Material for frame size 1 1. Shutter Subassembly (1) 2. Shutter Mounting Assemblies (2) 3. Shutter Mounting Assembly top (1) 4. Shutter Mounting Assembly bottom (1) 5. Socket head cap screws M6x10 with locking coating (6) Tools Required A. ¼i inch hblade flat thead screwdriver di B. M5 Allen Wrench A B 923 99902 176 2 / 8

Danger Peligro Danger! Hazardous Voltage Tensión peligrosa. Tension dangereuse. Will cause death or serious injury. Pueda causar la muerte o lesiones graves. Danger de mort ou risque de blessures graves. 1 INSTALL SHUTTER MOUNTS Shutter mounting assemblies are used to support the shutter assembly. There are two shutter mounts on the left side (Item 2) and two on the right side (Item 3 and 4) per shutter (as noted by the arrows below. Place each shutter mounting assembly into the cradle locking holes. Ensure that the locating dowel pins are seated. The front tines will pass through the rectangular opening in the cradle sidewall. Use the screwdriver blade to spread the front tines by inserting the screwdriver between the tines, and rotating the blade in clockwise and counter-clockwise motions. This will lock the shutter mounting assemblies to the cradle. left side right side 923 99902 176 3 / 8

Danger Peligro Danger! Hazardous Voltage Tensión peligrosa. Tension dangereuse. Will cause death or serious injury. Pueda causar la muerte o lesiones graves. Danger de mort ou risque de blessures graves. Place the Shutter subassembly (Item 1) in the way and sequence as noted by the arrows below. TOP VIEW 923 99902 176 4 / 8

Danger Peligro Danger! Hazardous Voltage Tensión peligrosa. Tension dangereuse. Will cause death or serious injury. Pueda causar la muerte o lesiones graves. Danger de mort ou risque de blessures graves. 2 INSTALL SHUTTER TO MOUNTS The shutter subassembly (Item 1) is secured to the shutter mounting assemblies (Item 2, 3 and 4) with six socket head cap screws M6x10 with locking coating (Item 5) as shown below. Torque each screw to 30 lb-in (four places). 2 1 3 2 4 923 99902 176 5 / 8

Danger Peligro Danger! Hazardous Voltage Tensión peligrosa. Tension dangereuse. Will cause death or serious injury. Pueda causar la muerte o lesiones graves. Danger de mort ou risque de blessures graves. 3 OPTIONAL: INSTALLING PADLOCK The WL shutter prevents incidental contact with primary conductors when the circuit breaker is removed from the cradle. At the user s option, a padlock may be installed through the arm on the right side of shutter assembly, as a means of locking out direct access to the primary conductors. One padlock through the arm is required to lock out primary conductor direct access. For frame size 1, a padlock may only be used on the right side. NOTE Remove padlocks before inserting breaker into the cradle. 923 99902 176 6 / 8

This page is intentionally blank. 923 99902 176 7 / 8

Siemens Industry, Inc. 5400 Triangle Parkway Norcross, GA 30092 1-800-241-4453 info.us@siemens.com Printed in USA 923 99902 176 8 / 7 2014 Siemens Industry, Inc. All Rights reserved Siemens is a registered trademark of Siemens AG. Product names mentioned may be Trademarks of their respective companies. Specifications are subject to change without notice.