Description. Specifications and Ordering Information 9200, 74712, Seismoprobe Velocity Transducer System

Similar documents
9200, Seismoprobe

9200, Seismoprobe * Bently Nevada* Asset Condition Monitoring

9200, Seismoprobe* Velocity Transducers

Velomitor * Piezo-velocity Sensor

Описание на сейсмозонды. Модели 9200, 74712

Velomitor* CT Velocity Transducer

and High Temperature Velomitor * System

and High Temperature Velomitor * System

Описание на пьезодатчики скорости. Модель

200150, & Accelerometers Bently Nevada* Asset Condition Monitoring

991 Thrust Transmitter Bently Nevada* Asset Condition Monitoring

991 Thrust Transmitter Bently Nevada* Asset Condition Monitoring

3300 XL High Temperature Proximity System

Case Expansion Transducer Systems

3300 XL 11mm Proximity Transducer System

8mm, 5mm Proximity Probe TM0180 and TM0105 Systems

Proximity Transducers, Seismic Sensors and Accessories

K-Beam Accelerometer. Acceleration. Capacitive MEMS, Triaxial Accelerometer. Type 8395A...

K-Beam Accelerometer. Acceleration. Capacitive MEMS, Triaxial Accelerometer. Type 8396A...

3300 RAM and NSv Proximity Transducer System

深圳市永旭伟业贸易有限公司. Description. a mm probe 1, 2 a 3300 XL extension cable (ref ) a 3300 Proximitor Sensor 3, 4, 5 (ref )

21022 Dual Axial Probe Housing Assembly Bently Nevada* Asset Condition Monitoring

3300 XL NSv Proximity Transducer System

CSI 9330 Vibration Transmitter

21000,24701 Proximity Probe Housing Assemblies Bently Nevada Asset Condition Monitoring

SYSTEMS ELECTRONICS GROUP

Proximity Transducers, Seismic Sensors and Accessories

3300 XL NSv* Proximity Transducer System Bently Nevada* Asset Condition Monitoring

MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS

Vibration Transducer Interface

3300 XL 11mm Proximity Transducer System

Compliance with API Standard 670 the PRO Product Standard for Proximity Probes

3500/45 Position Monitor

Proximity Transducers, Seismic Sensors and Accessories

Vibration Transducer SLD121 A

SKF Machine Condition Transmitters (MCT) Series

Optical Encoders. Sold & Serviced By: Toll Free Phone: Toll Free Fax:

Proximity Probes Seismic Sensors and Accessories

3300 XL 8mm Proximity Transducer System Bently Nevada* Asset Condition Monitoring

2300 Vibration Monitors

Easy Flow Indicator Magnetisch-Induktiver Durchflussmesser. Type 8024 For Insertion Fittings. Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI

3300 XL 8mm Proximity Transducer System

2300 Vibration Monitors

3500/25 Enhanced Keyphasor*Module

Vibration Switches. For 24/7 Protection of Cooling Towers, Fin Fans, HVAC Systems, Blowers, Motors and Other Critical Machinery

RK CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER (ANALOG OUTPUT OR START/STOP)

RK-A CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER

3500/77M Recip Cylinder Pressure Monitor

MODEL CV-86 SERIES INSTRUCTION MANUAL

Proximity Vibration / Position / Phase Reference Transmitters

3500/45E Position Monitor

Agilent 84904, 6, 7K/L Programmable Step Attenuators

Model 8042 Submersible Accelerometer

Electronic Vibration Switch PMC/BETA 440 & 450

3300 XL 8mm Proximity Transducer System

mm and 8 mm PROXIMITY TRANSDUCER SYSTEM

DX3309 / DP1009 / DD / DC1009 Series

07. har-link Interface Connectors

3500 Galvanic Isolator Interface Bently Nevada* Asset Condition Monitoring

Proximity Transducers, Seismic Sensors and Accessories

Описание на высокотемпературные системы близости. Модель 3300

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

ABSOLUTE ROTARY ENCODER INTERBUS

Heavy Duty Vibration Meter

Series PC 3.5 precision subminiature connectors

Description. Improved Startup/Shutdown Data Collection: New Ethernet Link to Data Manager* 2000 computers. View Transient Plots during machine SU/SD

1701/05 FieldMonitor* Terminal Base Bently Nevada* Asset Condition Monitoring

Remote Thru-beam Sensors

Bulletin 871D Cylinder Position Inductive Style

Ranger* Pro Wireless Condition Monitoring

Heavy Duty Vibration Meter

VITA 67 Series. Ideal For Blind Mate Applications. Electrical, Mechanical & Environmental Specifications

Operation The MICROSONIC sensors are continuous-wave devices that consist of an ultra-high-frequency

Model 356B41. Triax ICP Seat Pad Accelerometer per ISO Installation and Operating Manual

MTII4200 Level Transmitter Installation, Operation & Maintenance Instructions

3500/50E Tachometer Module

AGATE TECHNOLOGY AT-2030 OPERATORS MANUAL

PERFORMANCE SPECIFICATION ADAPTER, CONNECTOR, COAXIAL, RADIO FREQUENCY, (BETWEEN SERIES SMA TO SERIES TNC), CLASS 2, STRAIGHT PLUG

07. har-link INTERFACE CONNECTORS

Portable vibration calibrator Model 28959G

3500 Internal Barriers Product Datasheet Bently Nevada* Asset Condition Monitoring

T E M P O S O N I C S I I I INSTALLATION

3500/23E Transient Data Interface

Data Sheet. Model ER position sensor, features a versatile rod-and-cylinder design with optional dual rod ends. Interrogation Return wire.

PERFORMANCE SPECIFICATION

SDG1400 User s Guide

Absolute Encoders Multiturn

07. har-link Interface Connectors

NOVOHALL Rotary Sensor non-contacting. Series RSX-7900

60 mm sq. (2.36 inch sq.)

The SilverNugget is a servo controller/driver for NEMA 17 & 23 frame microstep motors.

MDT 2000 Magnetostrictive linear position transducer

Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid

SERIES MCX 50 MICRO MINIATURE CONNECTORS

Introduction. The information pages provide standard data common to all D-subminiature connectors. These include:

DATASHEET ABSOLUTE MAGNETIC ROTARY ENCODER CANOPEN

GAOTek Vibration Meter with 2 Channel (High-Quality Accelerometer)

The Model 464-BC Monitor controls and stores flow data from Marsh- McBirney Flo-Dar sensors. A portable computer and Flo-Ware software is used to

3500/23E Transient Data Interface

Incremental encoders Solid shaft with clamping or synchro flange pulses per revolution

Transcription:

R Specifications and Ordering Information 9200, 74712, 47633 Seismoprobe Velocity Transducer System Description Bently Nevada Seismoprobe Velocity Transducer systems are designed to measure absolute (relative to free space) bearing housing, casing, or structural vibration. The two-wire systems consist of a transducer, appropriate cable, and an optional velocity-to-displacement converter. The Seismoprobe family of velocity transducers are a two-wire design that uses moving-coil technology and provides a voltage output directly proportional to the transducer's vibration velocity. Unlike solid-state velocity transducers (which are inherently accelerometers with embedded integration electronics), moving-coil transducers are less sensitive to impact or impulsive excitation, and can represent a good choice for certain applications. Also, because they require no external power, they are convenient for portable measurement applications. Note: For the majority of installations, Bently Nevada's Velomitor family of velocity transducers incorporating solid-state technology represent superior performance and robustness for casing velocity measurement applications. Three types of Seismoprobe Velocity Transducers are available: 9200: The 9200 is a two-wire transducer suitable for continuous monitoring or for periodic measurements in conjunction with test or diagnostic instruments. When ordered with the integral cable option, the 9200 has excellent resistance to corrosive environments without need of additional protection. 74712: The 74712 is a high temperature version of the 9200. 47633: The 47633 is available in fewer mounting configurations and is only available with integral, non-armored cable. Its design uses a replaceable cartridge for easy replacement when the moving-coil element eventually wears out. It is intended for general-purpose applications where a velocity transducer with limited mounting options and performance is adequate. Various interconnect cables are available for connecting the 9200 and 74712 transducers to other instruments or a velocity-to-displacement converter. These cables are available in 300 mm (one-foot) increments, with or without stainless steel armor. Two types of velocity-to displacement converters (VDCs) are available: 9513: to be used with 9200 and 74712 transducers. 46687: to be used with 47633 transducers. BNC Part Number 141626-01 Page 1 of 10

Caution If housing measurements are being made for overall protection of the machine, thought should be given to the usefulness of the measurement for each application. Most common machine malfunctions (imbalance, misalignment, etc.) originate at the rotor and cause an increase (or at least a change) in rotor vibration. In order for any housing measurement alone to be effective for overall machine protection, a significant amount of rotor vibration must be faithfully transmitted to the bearing housing or machine casing, or more specifically, to the mounting location of the transducer. In addition, care should be exercised in the physical installation of the transducer. Improper installation can result in a decrease of the transducer amplitude and frequency, of the transducer amplitude and frequency response, and/or the generation of signals which do not represent actual machine vibration. Upon request, Bently Nevada can provide engineering services to determine the appropriateness of housing measurements for the machine in question and/or to provide installation assistance. Specifications Environmental Limits Operating and Storage Temperature: Environment: Relative Humidity: Physical Height: Diameter: Weight: 9200: -29 C to +121 C (-20 F to +250 F). 74712: -29 C to +204 C (-20 F to +400 F). Dust and moisture resistant. Note: Contact your nearest Bently Nevada Sales Professional regarding transducer operation in a radiation environment. To 95%, noncondensing. 100%, non-submerged, when ordered with integral cable. 102 mm (4 in) typical (depends on connector option). 41 mm (1.6 in) typical. 480 grams (17 ounces) typical. 9200 and 74712 Seismoprobe Velocity Transducers Specifications are at +22 C (+72 F) and 25 mm/s (1 in/s) at 100 Hz unless otherwise specified. Electrical Velocity-to-Displacement Converters Electrical Sensitivity: Frequency Response: Shock Resistance: Transverse Sensitivity: Leadwire Length: 20 mv/mm/s (500 mv/in/s), ±5% at 100 Hz (6,000 cpm) and 25 mm/s (1 in/s) zero-to-peak, ±5% at 100 Hz (6,000 cpm) when properly terminated and oriented at the angle of calibration. From minimum operating frequency (see ordering information) to 1 khz (60,000 cpm); +0, ±3dB typical. Withstands 50 g peak maximum acceleration. ±10% maximum. 305 metres (1,000 feet) maximum between Seismoprobe and 3300 Monitor. Consult manual for frequency roll-off at longer lengths. Model 9513 requires: Model 46687 requires: -18 Vdc. -24 Vdc. Output Sensitivity (with a 500 mv/in/s input) 9513-02: 200 mv/mil (8 V/mm) ±5%. 46687-01: 200 mv/mil (8 V/mm) ±5%. Frequency Range: Minimum operating frequency to 10 khz (600,000 cpm). Output Impedance: For model 9513-02, 100 Ω. Output Bias: 5.8 to 9.5 Vdc. BNC Part Number 141626-01 Page 2 of 10

Physical 46687 Height: Width: Length: 51 mm (2 in) 61 mm (2.40 in) 79 mm (3.10 in) 0 6 Coaxial connector (for test equipment only) 0 7 Thru 5 0 Environmentally-resistant with integral cable. Option number corresponds to cable length 7.0 feet (2.1 metres) min., 50.0 feet (15 metres) max., ordered in increments of 1.0 foot. Weight: Mounting Holes: 9513 Height: Length: Width: Weight: Mounting Holes: Seismoprobe Orientation: Ordering Information 220 grams (7.90 ounces) Four 4.8 mm (0.19 in) diameter holes centered in all corners of a 50.8 mm (2 in) square. 38 mm (1.50 in) 89 mm (3.50 in) 54 mm (2.12 in) 180 g (6.50 oz) Four 4.8 mm (0.19 in) diameter holes centered in all corners of a rectangle 50.8 mm (2 in) long by 44.5 mm (1.75 in) wide. All Seismoprobe Velocity Sensors are specified for mounting orientations as shown in Figure 1. Two-wire Transducer The 9200 Two-wire Velocity Seismoprobe transducer can be used with the 9513 VDC which is ordered separately (see Velocity-to-Displacement Converters). 9200-AXX-BXX-CXX-DXX Option Descriptions A: Transducer Mounting Angle/Minimum Operating Frequency Option 0 1 0 ±2.5, 4.5 Hz (270 cpm) 0 2 45 ±2.5, 4.5 Hz (270 cpm) 0 3 90 ±2.5, 4.5 Hz (270 cpm) 0 6 0 ±100, 10 Hz (600 cpm) 0 9 0 ±180, 15 Hz (900 cpm) B: Connector Option 0 1 Top Mount 0 2 Side Mount 0 5 Terminal block top mount C: Mounting Base Option D: Agency Approval Option 0 1 Circular; 1/4-in 20 UNC stud 0 2 Circular; 1/4-in 28 UNF stud 0 3 Rectangular flange 0 4 Circular; with three 8-32 threaded studs on a 44 mm (1.75 in) diameter bolt circle 0 5 No base; 1/2-in 20 UNF-3A stud 0 6 Isolated circular 1/4-in 20 UNC stud 0 7 Isolated circular 1/4-in 28 UNF stud 0 8 Isolated rectangular flange 0 9 Isolated circular 5/8-in 18 UNF stud 1 0 Circular; M10X1 stud 0 0 No approvals required 0 1 CSA/NRTL/C 0 2 BASEEFA 0 3 Not Available Hi-temp two-wire transducer The 74712 High Temperature Two-Wire Velocity Transducer can be used with the 9513 VDC which is ordered separately (see Velocity-to-Displacement Converters). 74712-AXX-BXX-CXX DXX Option Descriptions A: Transducer Mounting Angle/Minimum Operating Frequency Option B: Mounting Base Option 0 1 0 ±2.5, 4.5 Hz (270 cpm) 0 2 45 ±2.5, 4.5 Hz (270 cpm) 0 3 90 ±2.5, 4.5 Hz (270 cpm) 0 4 135 ±2.5, 4.5 Hz (270 cpm) 0 5 180 ±2.5, 4.5 Hz (270 cpm) 0 6 0 ±100, 10 Hz (600 cpm) 0 7 0 ±180, 15 Hz (900 cpm) 0 1 Circular; 1/4-in 20 UNC stud 0 2 Circular; 1/4-in 28 UNF stud 0 3 Rectangular flange 0 4 Circular base with three 8-32 studs 0 5 No base; 1/2-in 20 UNF-3A stud BNC Part Number 141626-01 Page 3 of 10

C: Connector Option 0 1 Coaxial connector for test equipment only: rated to +165 C (+329 F). 0 2 Top mount 0 3 Terminal block top mount 0 4 Side mount D: Agency Approval Option 0 0 No approvals required 0 1 CSA/NRTL/C 0 2 BASEEFA 0 3 Not Available Velocity-to-Displacement Converters For 9200 and 74712 Velocity Transducers (requires -18 Vdc supply): 9513-02 200 mv/mil (8 V/mm). For 47633 Velocity Transducer (requires -24 Vdc supply): 46687-01 200 mv/mil (8 V/mm). Interconnect Cables Standard Cables 9571 2-conductor twisted, shielded 22 AWG (0.5 mm 2 ) cable with 2-socket moisture-resistant female connector at one end, terminal lugs at the other end. (Used with monitors or VDCs). 84661 2-conductor twisted, shielded 22 AWG (0.5 mm 2 ) armored cable with 2-socket moisture-resistant female connector at one end, terminal lugs at the other end. (Used with monitors or VDCs). 9755 2-wire shielded 22 AWG (0.5 mm 2 ) cable with 2-pin female connectors at each end. (Connects 9200 or 74712 Seismoprobe transducers to Bently Nevada test kits). 83968 2-wire straight cable with 2-pin female connector at one end and coaxial connector in the other end (used with instruments with BNC connector input jacks). Minimum length is 1.5 metres (5 feet). High-Temperature cables 84508 2-wire shielded 22 AWG (0.5 mm 2 ) cable with terminal lugs at each end. 84509 2-wire shielded 22 AWG (0.5 mm 2 ) armored cable with terminal lugs at each end. 84660 2-wire shielded 22 AWG (0.5 mm 2 ) cable with 2-socket female connector at one end, terminal lugs at the other end. 84510 2-wire shielded 22 AWG (0.5 mm 2 ) armored cable with 2-socket female connector at one end, terminal lugs at the other end. 87143 2-wire shielded 18 AWG (1.0 mm 2 ) cable with terminal lugs at each end. Withstands 204 C (400 F). Cable Part Number-AXX A: Cable Length Option in feet Accessories Order in increments of 1.0 ft (305 mm). Example: 0 9 = 9 ft 1 2 = 12 ft Minimum length (armored): 3.0 ft (0.9 m) Minimum length (unarmored): 2.0 ft (0.6 m). Maximum length (armored): 70 ft (21 m). Maximum length (unarmored): 99 ft (30 m). 80705-01 Coiled 2-conductor cable with 2-pin connector at one end and BNC connector at the other end (used with instruments with BNC connector input jacks). Coiled length of 0.5 metre (19.6 inches), stretched length of 2 metres (6.5 feet). 46000-01 Magnetic Base for portable mounting or Seismoprobes. 46122-01 Quick connect for semi-permanent mounting of Seismoprobe velocity transducers BNC Part Number 141626-01 Page 4 of 10

02173006 Bulk cable; 2-conductor, twisted, shielded. 18 AWG (1.0 mm 2 ) cable without connectors or terminal lugs. Specify number of feet. Withstands +204 C (+400 F). 78920-01 Adapter for installing 47633 General-purpose Seismoprobe Velocity Transducer in 21128 stainless steel housing. 00531061 Mating connector for 9200 and 74712 transducers. 00530574 Clamp Specifications 47633 General Purpose Velocity Seismoprobe transducer Environmental Limits Operating Temperature: Storage Temperature: Relative Humidity: Physical Reference Height: Cartridge Diameter: Cartridge Weight: -29 C to +82 C (-20 F to +180 F) -29 C to +82 C (-20 F to +180 F) 100%, nonsubmerged. (NEMA 4 requirement) 114 mm (4.50 in) with mounting base. 32 mm (1.25 in) 340 g (12.0 oz) Specifications are at +22 C (+72 F) and 25 mm/s (1 in/s) at 100 Hz (6,000 cpm) unless otherwise specified. Ordering Information Electrical Frequency Response: Sensitivity: Amplitude Linearity Error: Amplitude Range: Transverse Sensitivity: 10 Hz to 1 khz (600 cpm to 60,000 cpm) +0, ±3dB typical. 20 mv/mm/s (500 mv/in/s) ±5% at 100Hz (6,000 cpm) and 25 mm/s (1 in/s) peak with a mounting tolerance of ±30 for vertical (-01 option) or ±10 for horizontal (-02 option) when operated into a 24.9 k Ω load. ±3% at 100 Hz (6,000 cpm) from 0.1 to 2.5 to 127 mm/s (5.0 in/s) peak. 0.81 mm (32 mils) peak-to-peak, maximum. ±12% maximum. General-purpose two-wire Seismoprobe Velocity Transducer 47633-AXX-BXX-CXX Option Descriptions A: Integral Cable length option B: Transducer Orientation Option 0 2 2 metres (6 feet) 0 6 6 metres (19 feet) 1 0 10 metres (33 feet) 2 0 20 metres (66 feet) 3 0 30 metres (98 feet) 0 1 Vertical, 0 ±30 0 2 Horizontal, 90 ±10 C: Mounting Option 0 0 No Base 0 1 With 3/8-in 24 UNF stud and 3/8-in 18 NPT adapter 0 2 With 1/2-in 13 UNC stud and 1/2-in 14 NPT adapter half union disconnect Note: To order the replaceable cartridge only, specify the No Base Mounting Option. 2000 Bently Nevada Corporation used in this document are registered marks of Bently Nevada Corporation BNC Part Number 141626-01 Page 5 of 10

Figure 1: Seismoprobe Orientation All Seismoprobe velocity transducers are specified for mounting orientations as shown above: 0 is vertical, as viewed from driver end. Figure 2: Theoretical Velocity Seismoprobe Frequency Response BNC Part Number 141626-01 Page 6 of 10

Figure 3: Theoretical Phase Shift between Output and Case Velocity Figure 4: Top Mounted Connector 9200 Option -01 or 74712 Option-02 Figure 5: Side Mounted Connector 9200 Option -02 or 74712 Option -04 BNC Part Number 141626-01 Page 7 of 10

Figure 6: Terminal Block Connector 9200 Option -05 or 74712 Option -03 Figure 7: BNC Connector 9200 Option -06 or 74712 Option -01 Figure 8: 9200 Connector Options -05 thru -07 Option -05 No Base required, Option -06 Isolated Circular 1/4-20 UNC-2B, and Option -07 Isolated Circular 1/4-28 UNF-2B All dimensions are in millimetres (inches) BNC Part Number 141626-01 Page 8 of 10

Figure 9: 9200 and 74712 Mounting Base Option -01 or -06 Option -01 Circular 1/4-20 UNC-2B, or Option -06 Isolated Circular 1/4-20 UNC-2B Figure 10: 9200 and 74712 Mounting Base Options -02 or -07 Option -02 Circular 1/4-28 UNF-2B, or Option -07 Isolated Circular 1/4-28 UNF-2B Figure 11: 9200 and 74712 Mounting Base Options -03 or -08 Option -03 Flanged or Option -08 Isolated Flanged Figure 12: 9200 and 74712 Mounting Base Option -04 3 each 8-32 studs BNC Part Number 141626-01 Page 9 of 10

Figure 13: 9200 and 74712 Mounting Base Option -09 Isolated Circular 5/8-18 UNF-2A Base Figure 14: 9200 and 74712 Mounting Base Option -10 or -11 Option -10 Circular M10x1 or Option-11 Isolated Circular M10x1 Base BNC Part Number 141626-01 Page 10 of 10