For Conergy SunTop only

Similar documents
Product Pricing List 2009

March Roof Product Guide. Warehouses located in Atlanta, GA and Temecula, CA

Microinverters And The Solar Industry

G12/G12x USER S MANUAL

IRONRIDGE PRODUCT CATALOG

EVOLVE1-M MONITOR ARM

HP ProLiant DL165 G7 Server

PARAVION TECHNOLOGY, INC AIRWAY AVENUE FT. COLLINS, COLORADO

DirectCommand Installation Case/Flexi-Coil/New Holland Air Cart Kit (Variable Rate Electro Hydraulic Systems) Ag Leader Technology

AIR TERMINALS: COPPER

METRIC TO OPERATE OVERHEAD VALVES DUCTILE IRON STAINLESS STEEL ALUMINUM CARBON STEEL

Installation Guide Philips MP20/30/40/50/60/70 IntelliVue M-Series Arm Rail Mount Kit

Portable Staging User Guide

Fixed Camera Housing. Installation. Customer Support. Parts Required. Tools Required. Procedure. If you need assistance... Installation Guide

Modular Table Power System Installation for Runner Non-folding Plug and Play Tables

Dimensions in mm in mm in. R in mm in mm mm. Weight. Dimensions in.

Chevy Tahoe Installation Instructions

SOLARMOUNT PART & ASSEMBLY BONDING CLAMPS 9/27/2017

Formulate Designer Series 20 Backwall - Kit 11

Adjust-O Magnet Squares

PV Rapid Shutdown device

Formulate Accent - 04

Installation Guide Mounting Kit for Mounting Philips Avalon CTS Cordless Fetal Transducer System on Wall, 2'' Post, Rail, or Slide-on Mounting Plate

Replacing the Power Supply

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

HIGH DENSITY TERMINAL BLOCKS

INSTALLATION INSTRUCTIONS

TABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION

sunmax Residential Solar Solution sunmax Hardware sunmax Software

INSTALLATION INSTRUCTIONS

TensionLitePlus Kiosk Design 4

Portable Staging User Guide

Conergy PH Series Modules. Solar module user manual

ISOLATION RELAY RACK ISOLATION KIT 19 RACK MOUNT RELAY RACK ISOLATION KIT, SLOTTED UNEQUAL FLANGE RACK ISOLATION KIT 23 RACK MOUNT

Conductor and Cable Marking Description and Handling

Series 062 Bus Bar Connectors

LED. Sign Module. Assembly Manual

HL-DL. Direct View Architectural Delineation LED System INSTALLATION GUIDE

Rhino Pioneer Full Rail Kit (43180B, 43181B, 43182B, 43183B, 43184B, 43185B, 43187B, 43188B, 43189B,43201B, 43227B, 43228B, 43229B, 43230B, 43231B.

256 Kbytes (1771-DRS) 1 Mbyte (1771-DRS1) 4 Mbytes (1771-DRS4) Installation Data

Architectural Trim & Moldings

Westell. Breaker Panel Technical Practice NPDRP1114

Breaker Panel Technical Practice NPDRP1114

3M Cross-Connect Cabinet Riser Installation Guide

ORLANDO BERLIN. High quality and elegance à from the doorplate to the outdoor stand the lightly

Installation Guide Philips MP60/70 IntelliVue VHM Arm Rail Mount Kit

TDM To MiniMech conversion ProceDure

(Cat. No A1B, -A2B, -A3B, -A3B1, -A4B Series B) Installation Data. Make sure you have these items:

or

Treadmill Integrated LCD Screen Option. Cardio Theater Integrated Bracket Assembly Instructions

User s Guide. Includes Mounting, Installation, and Product Registration nd Avenue NE Arlington, WA USA (+1)

Cab Box Kit Dome Plug Cab Box Cab Box Lid

SENC 150 REFERENCE MANUAL

Module clips. Certified by First Solar and Calyxo

IBM. Rack Installation Instructions

Rack Installation Instructions

ATTENTION: OBSERVE PRECAUTIONS FOR HANDLING ESD-SENSITIVE DEVICES

APC Open Frame Rack Networking Solutions

2.1 MANAGEMENT UNIT INSTALLATION

Architectural Trim & Moldings

Formulate Kiosk features and benefits: dimensions: additional information:

Standard Strip Series

BS EN Class H, BS 7430 UL467 (CR105) Tightening torque 15 Nm mm mm kg CR525

ML200 Fanless Mini-ITX Enclosure

PERFECT HANDLING. PCB Front Panels & Injector/Extractor Handles... Package Your Electronics With Ripac.

QUICKBOLT I NS TALL ATI ON I N S TR UC T IO NS

Shop Fox Fence Kit Installation Instructions:

Terminals, Lugs, and Fasteners

Mounting Instructions for MTP Modules

Installation Notes TII Model 341 Protector

Part Name/Description Part Number Quantity

- ELV OVERVIEW. InstallationGuide SUPPLIED PARTS RELATED PARTS. Brackets Fixtures. Other. 1 of 9 IG-STR9-ELV

2 To display the Administration Home page, click the Administration link. (You may need to provide the Administrator password.)

120Ra-1 Pentium III Processor Installation Insert

Baffle Attached to Heavy Duty T Bar Installation Instructions

If you are missing any of the following items, please contact Stanton Video immediately (602)

Assembly Instructions for #5630 Medication PalWOW

IBM Systems. Quick start guide for IBM System p5 505 ( )

A TCP/IP network CAT 5 cable If the network is faster than 10baseT a switching hub will be needed Static IP address

SMART HEATSINKS UNIVERSAL MOUNTABLE, AUTO-ALIGN HEAT SINKS

Replacing the Colored Accent Ring EXTREME-PERFORMANCE 240MM LIQUID CPU COOLER QUICK START GUIDE

Replacement Keyswitch Assembly

ASSEMBLY INSTRUCTIONS for 16 WAY GT MIXED 150/280 SEALED CONNECTION SYSTEM

Bulletin Installation of solar photovoltaic systems Rules , , , , and

M-2300-ZX Focus SVT Brake Conversion Kit INSTRUCTION SHEET

A-100G6 - Basic frame assembly diagram

hp uninterruptible power system r12000 xr models installation instructions

Installation Guide for America Solar Wholesale Photovoltaic Modules

serial number A1159T or lower, which includes all manufactured in 2008 Not compatible and not required. Figure 1 Auger Update Sites Call-Outs R B

CLIPLINE complete. The modular terminal block system for all applications

The Gradient Control Mat (GCM)

Formulate 20 x 20 Island Exhibit - Kit 10

System Storage EXP3000 Rack Installation Instructions

Want to make your inspectors happy?

INSTALLATION INSTRUCTIONS

Z-Truck (Vertical Moving) Z-truck Flag. Y-Truck (Horizontal Moving) FIGURE 1: VIEW OF THE Z-TRUCK. Flexshaft Assembly

Project Olympus Chassis Mechanical Specification

Cycles Integrated LCD Screen Option. Cardio Theater Integrated Bracket Assembly Instructions

features and benefits: dimensions: Approximate weight with cases: 124 lbs / 56.2kgs Shipping Packing case(s): 1 OCE 1 OCH

Quick Installation Guide

Transcription:

Wiley Electronics LLC Washer, Electrical Equipment Bond WEEB Patent Pending INSTALLATION INSTRUCTIONS For Conergy SunTop only Please read carefully before installing. WEEB-CMC WEEBL-8.2 WEEB Bonding Jumper-8.2 Products are tested to UL 467 3098177 UL standard for safety grounding and bonding equipment Document Number 104-0404-000012-003

WEEB COMPATIBILITY The WEEB family of products can be used to bond anodized aluminum, galvanized steel, steel and other electrically conductive metal structures. Standard Top Down Clamps The WEEBs used for bonding the PV modules to the mounting rails are compatible with various cross-sections of module frames. The following are examples of module frames that are compatible. Notice that the WEEB teeth are positioned completely under the edge of the module frame. OK OK OK The following is an example of a module frame that is incompatible with the WEEB. The WEEB teeth are positioned only partially under the edge of the module due to the lip on the top edge of the module frame.

Top Down Clamps for Lipped Modules The following are a few variations of lipped solar modules mounted with inverted U-shaped clamps. Notice that the WEEB teeth are positioned so that they are in contact with the modules. OK Low-Lipped Module WEEB-CMC is not compatible with high lipped modules. The WEEB teeth do not intersect with the solar module frame. High-Lipped Module

SYSTEM OVERVIEW Use WEEB-CMC to bond solar modules to module mounting rail Use WEEB Bonding Jumper 8.2 to electrically connect spliced rails Important notes: 1. 2. Use one WEEBL-8.2 per rail to connect to equipment ground conductor Use general purpose anti-seize compound on fastener threads when installing WEEBs. WEEBs are intended for SINGLE USE ONLY. Functionality will not be guaranteed if reused.

WEEB-CMC LAYOUT EVEN NUMBER OF MODULES IN ROW DENOTED PLACES TO INSTALL WEEB-CMC CR = 41 WEEB-CMC NEEDED = CR = 41 = 4 ODD NUMBER OF MODULES IN ROW DENOTED PLACES TO INSTALL WEEB-CMC CR = 51 WEEB-CMC NEEDED = [C+1]R = [5+1]1 = 6 Note: When replacing a single faulty module, also remove the adjacent module which contacts the same WEEBs as the faulty module. This will ensure that there are never ungrounded modules in the array.

Installing WEEBL-8.2 Grounding Lug Assembly Assemble WEEBL-8.2 grounding lug assembly onto mounting rail as shown in figure below. Ensure that WEEB teeth contact the rail. Refer to manufacturers instructions on the use of the Quickstone technology. Tighten to 7 ft-lb Tighten to 10 ft-lb Quickstone WEEBL-8.2 WEEB teeth engages bonding surface on mounting rail

Installing WEEB-CMC Module Bonding Clips Bolt retention tabs Rail retention tabs WEEB-CMC Pre-assemble WEEB-CMC onto mid clamp assembly Solar module frames Tighten to 15ft-lb Install midclamp hardware into mounting rail, then snap WEEB-CMC onto mounting rail. When properly installed, the mid-clamp and WEEB-CMC assembly slide along rail for easy positioning. Ensure WEEB teeth contact both the solar module and mounting rail surfaces before tightening bolt.

Recommended Installation Procedure 1 Install mounting rails per manufacturer's specifications. Before installing solar modules onto mounting rails, use one WEEBL-8.2 grounding lug assembly per rail to connect mounting rails to equipment ground conductor. For long rails with splices, use the WEEB Bonding Jumper-8.2 to electrically connect spliced rails. WEEBL-8.2 grounding lugs are designed with a low profile to fit under the solar modules for an asthetically pleasing installation. Proper planning will ensure that the lug assemblies are positioned beneath the modules and away from the edge of the modules where the clamps are located. WEEBL-8.2 grounding lug connects to equipment ground conductor. Equipment Ground Conductor Use WEEB Bonding Jumper 8.2 to electrically connect spliced rails Note: To enhance safety during installation, connect equipment ground conductor to ground before installing solar modules. Solar modules will be grounded as they are installed to the grounded mounting rails.

2 Install end clamps to manufacturer's specification. Ensure that the solar modules are perpendicular to the mounting rails. Note: WEEB teeth contact the edge of the solar module frame and mounting rail to form the grounding connection. Module misalignments may cause WEEB teeth to miss the edge of the modules. Visually check that WEEBs are properly positioned. Install end clamp to manufacturer's specifications Install mid-clamp assembly, aligning WEEB-CMC by positioning the mid-clamp against the edge of the solar module Verify that the WEEB teeth are in full contact with the edge of the solar module and the mounting rails. Make necessary adjustments before installing the next module.

3 Position edge of module against mid-clamp When installing the next module, ensure that the WEEB teeth contacts the edge of the module. Make the necessary adjustments before tightening bolt to 15 ft-lb. When all modules in the row are installed, install end clamp to manufacturer's specification. Refer to WEEB layout to determine WEEB-CMC usage.