SmartBlock I/O Module HE579MIX102 Isolated 6 Relay, 12 DC Inputs, 4 Analog Inputs

Similar documents
SmartBlock I/O Module HE579MIX577/977 Isolated 4/8 Analog Inputs 2/4 Analog Outputs

Thermocouple / Millivolt Input Module HE800THM000 / HE800THM100 HE-THM000 / HE-THM100* * HE- denotes plastic case.

Temperature I/O Module HE800MIX963 / HE-MIX963* * HE- denotes plastic case.

4-20 ma Analog Input Module HE800ADC020 / HE800ADC120 HE-ADC020* / HE-ADC120* 12-Bit Resolution * HE-denotes plastic case.

24VDC Bipolar Digital In 10-28VDC, 0.5A Sourcing Digital Out 4-20mA Analog In/Out HE800MIX902 / HE-MIX902* * HE- denotes plastic case.

MAN October 2010 PAGE 1 HE-579ACM300 SmartBlock Power and Energy Monitor HE-579ACM300

RTD Input Module HE800RTD000 / HE800RTD100 HE-RTD000 / HE-RTD100* * HE- denotes plastic case.

Thermistor / Current / Voltage Analog Input Module HE800ADC920 / HE-ADC920* 12-Bit Resolution * HE- denotes plastic case.

DeviceNet Master (Scanner) HE800DNT450 / HE-DNT450* DeviceNet Communications * HE- denotes plastic case.

SmartRail I/O Ethernet Base HE599ETX300

XL4 OCS DATASHEET MODEL DC In, 12 DC Out, 2 12-bit Analog In. Serial Ports. USB mini-b USB A. CAN Port Isolated 1 kv.

24VDC Bipolar Digital In 10-28VDC, 0.5A Sourcing Digital Out 0-20mA Sourcing Analog In/ Out HE800MIX906 / HE-MIX906* * HE- denotes plastic case.

SmartMod DC Digital Input Module HE359DIM610 12/24VDC Negative Logic

Specifications / Installation. Specifications Digital DC Inputs XL103 XL104 Digital DC Outputs XL103 XL104

Specifications / Installation. QX Series Models:

XL7 OCS Datasheet for HE-XW1E0, HE-XW1E2, HE-XW1E3, HE-XW1E4, HE-XW1E5 HEXT391C100, HEXT391C112, HEXT391C113, HEXT391C114, HEXT391C115

4-20mA Analog Output Module HE800DAC002 / HE800DAC102 HE-DAC002* / HE-DAC102* 14-Bit Resolution * HE- denotes plastic case.

QX751 CANOpen HEQX751C203/HEQX751C205 HE-BP41/HE-BP43 Back Pack Module

XL4 OCS DATASHEET MODEL DC In, 6 Relay Out, 4 12-bit Analog In. Serial Ports. USB mini-b USB A. CAN Port Isolated 1 kv. Gen.

AC Input /AC Output. Module

Advanced Ladder Logic Required Power 24VDC. Full IEC Languages (Steady state) (heater duty cycle) 24VDC

XL4 OCS Datasheet for HE-XC1E0, HE-XC1E2, HE-XC1E3, HE-XC1E4, HE-XC1E5 HEXT251C100, HEXT251C112, HEXT251C113, HEXT251C114, HEXT251C115

Thermistor / Current / Voltage Analog Input Module HE800ADC920 / HE820ADC920* 12-Bit Resolution * HE820 denotes plastic case.

MAN MAY 2003 PAGE 1 OCX VDC Bipolar Digital In 10-28VDC, 0.5A Sourcing Digital Out ±10V, ±20mA Analog In/Out HE500OCX404 / HE500RCX404

BMX DDM Mixed Relay Input/Output module

SAVE THESE INSTRUCTIONS

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION IMPORTANT SAFETY INSTRUCTIONS

Thermocouple Input Module Product Specifications and Installation Data

General Specifications. P2-08THM Analog Input

SAVE THESE INSTRUCTIONS

Tempco Instruction Manual

SAVE THESE INSTRUCTIONS

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

Model 7705 Control Module

User Manual for XL-J1939

SEM3 - Embedded Micro Metering Module

em4 Accessories Digital expansions

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

Installation and Wiring

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Control & Logic Specifications Required Power 24 VDC (355mA with heater operating).

MAXIMA+ Series Rotary Level Indicator

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

MODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT

Specifications

SCB-68 User Guide. 68-Pin Shielded Desktop Connector Block

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

Installation Requirements for Conformance to Standards

5B Series 16 Channel Backplane 5B01 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Installation, Operation and Maintenance Manual

USER MANUAL INSTALLATION MANUAL. Isolation transformers. ITR Isolation Transformer 7000 W 230V/32A

User safety and equipment protection guidelines

V E2B Snap-in I/O Module

IMPORTANT PRODUCT INFORMATION

CAN Fiber Optic Modem

ACCESS 9340/9360 Meter Input/Output Module

SLATE. Digital I/O Module INSTALLATION INSTRUCTIONS R8001D4001

DL05 CPU Specifications. Performance Contact execution (Boolean) µs Typical scan (1K Boolean) ms.

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

Digital ac/dc (24V) Input Module

PS/IO Circuit Board Retrofit

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

MAXIMA + Series ROTARY LEVEL CONTROL

Autoranging True RMS Multimeter User Manual

Select a Micro800 Controller

This Datasheet for the IC660BBD025. Block 5/12/24Vdc Sink I/O 32 Circuits.

Model 8010 High Power Device Test Fixture Interconnection Reference Guide

24/48/120 VAC Interface Card Instruction Manual

PM Series Power Meter

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

V E1B Snap-in I/O Module

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

Electrical network protection Sepam series 20 Sepam series 40 Quick start

Zenith DS9000 Dispensing System

Installation manual for for Schleifenbauer DPM3

Safegard V4 Panel. Installation Datasheet. Safegard V4 Panel Installation Instructions and Datasheet release 1.7 August 2016

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

OPERATING INSTRUCTION

Component identification

PV Rapid Shutdown device

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

Installing the Tracer MP503 Input/Output Module Ordering number: ,

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

BA/BS4S Temperature Sensor Installation & Operating Instructions

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

Environmental Operating Temperature 0-60 degrees C Humidity (non condensing) 5 to 95% NEMA 4/12 faceplate (NEMA4x/12 for Mini OCS)

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A

E2Q4 Square Proximity Sensor

Installing the IPS 4345 and IPS 4360

Installing Your 1394 Drive Interface Module

H704-42(H)(E), H704-42/1(H)(E)

IMPORTANT SAFETY INSTRUCTIONS

Installation & Operation Guide

A0-10 ANALOG OUTPUT. Instruction Manual April 2001 NALOG OUTPUT

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

VibraLINK switchable junction boxes Installation and operating guide VLL series

Transcription:

MAN0959-01 PAGE 1 Mix102 module ` SmartBlock I/O Module HE579MIX102 Isolated 6 Relay, 12 DC Inputs, 4 Analog Inputs 1 SPECIFICATIONS Digital DC Inputs Digital Relay Outputs Inputs per Module 12 Outputs per Module 6 relay Commons per Module 2 Commons per Module 6 Input Voltage Range 12 VDC / 24 VDC Max. Output Current per Relay 3 A at 250 VAC, resistive Absolute Max. Voltage 35 VDC Max. Max. Total Output Current 5 A continuous Input Impedance 10 k! Max. Output Voltage 275 VAC, 30 VDC Isolation 500 V Response Time Comm Time + 10 ms Current Max Upper Threshold 0.7 ma Max. Switched Power 1250 VA, 150 W Current Min Lower Threshold 0.2 ma Contact Isolation to XLe ground 1000 VAC Voltage Max. Voltage Drop at Rated 8 VDC Max Upper Threshold Current 0.5 V Voltage Expected Life No load: 5,000,000 3 VDC Min Lower Threshold (See Derating section for chart.) Rated load: 100,000 Max. Switching Rate 300 CPM at no load 20 CPM at rated load Type Mechanical Contact Analog Inputs High Resolution Number of Channels 4-10 to 10 VDC Input Ranges -5 to 5 VDC 0 to 20 ma 4 20 ma Safe input voltage range ma -0.5 to 5 V V -0.5 to +30 V Isolation 500 V Input Impedance Current Mode: 55! Voltage Mode: 1 meg! Nominal Resolution 16 Bits %AI full scale 32,000 counts Max. Over-Current 35 ma Max. Error at 25 C (excluding zero) 0.1% Additional error for temperatures other than 25 C TBD Filtering 16 Hz hash (noise) filter 1-128 scan digital running average filter General Specifications Voltage Input 10-30 VDS Relative Humidity 5 to 95% Non-condensing Required Power (Steady State) 2W (80mA @ 24VDC) Required Power (Inrush) DC Switched: 12A 50uS AC Switched: 120mA 10mS Operating Temperature 0 to 60 Celsius Weight 12oz/340g

MAN0959-01 PAGE 2 Mix102 module 2 DIMENSIONS AND INSTALLATION J2 Relay 1 to 6 and Inputs 11 & 12 2.16 (54.8mm) With connector 2.84 (72.1mm) Can and Power Connector 4.48 (113.7mm) 4.56 (115.8mm) Status LEDs Network ID Selector Switches J1 Analog Inputs 1 to 4 and Inputs 1 to 10 CAN Network & Power Connector Torque rating 4.5 7 Lb-In (0.50 0.78 N-m) CAN Network & Power Port Pin Assignments Pin Signal Signal Description Direction 1 V- CAN and Device Ground - Black 2 CN_L CAN Data Low - Blue In/Out 3 SHLD Shield Ground - None " 4 CN_H CAN Data High - White In/Out 5 V+ Positive DC Voltage Input (10-30VDC) - Red " " Earth Ground Location Network, Power and Grounding: A single 5 pin connector is used to make both a network connection and power input. A quality class 2 power supply should be used for this product. If the power is run with the network cable, care must be taken such that the voltage does not drop below the lower supply limit on longer runs. A quality earth ground is required for safe and proper operation. The best ground is achieved by screwing the lower left grounding location into a grounded back plate. Alternately a ground can be connected to the spade lug. Please see Horner manual MAN0799 for details on CAN wiring.

MAN0959-01 PAGE 3 Mix102 module 3 WIRING

MAN0959-01 PAGE 4 Mix102 module 4 CONFIGURATION For most applications the I/O scanner built into Cscape and the OCS firmware will provide a fast, robust and easy to use method to configure and scan the SmartBlock I/O. For advanced operations such as onthe-fly changes to the input type please see the following chapter on network data and the SmartStix and SmartBlock programming guide. To configure SmartBlock I/O from Cscape open the Hardware Configuration dialog from the Controller Hardware Configuration menu. Select the option for CsCAN I/O, then click Add. Select the SmartBlock Tab and select the device to be configured. Below is the configuration for MIX102 device. Network ID This should match the ID of the rotary switch on the SmartBlock unit and should be unique to the network. I/O Mapping These registers define how the OCS controller registers are mapped to the data to and from the SmartBlock I/O. These registers do no have to match the I/O types typically used for I/O such as %AI, Q Any standard controller registers may be used such as %R, %T and %M. Input Update Method This defines how often analog data is sent from the SmartBlock to the CsCAN network. Digital data is transmitted on change of state. Channel Configuration This selects how each analog channel is configured including filtering. Timeout This sets the time a controller will wait before assuming the host OCS is off-line.

MAN0959-01 PAGE 5 Mix102 module 5 NETWORK DATA Consumed Digital Data This data is sent from the controller to the SmartBlock. For typical applications the I/O configuration setup in Cscape will automatically populate this data. For more advanced applications you may use NetPut functions to write this data. Please see the advanced programming guide MAN0880 for more details. Bit Description 1-4 Mode Bit 1 bit per channel 0 = Voltage Mode 1 = Current mode 13-16 Filter See programming Guide 17-20 Scale Bit 1 bit per channel 0 = ±10V or ±20mA 1 = ±5V or 4-20mA 81-86 Digital Outputs Bits that control the relay outputs 97-102 Digital Stop Overrides Bits that allow override of outputs on stop 113-118 Digital Stop Defaults Values for override on stop Produced Digital Data This data is sent from the SmartBlock to the controller. Normally this data is mapped into specific registers in the I/O configuration in Cscape. For advanced applications NetGet functions can be used to obtain this data. Since this data is broadcast to all controllers on the network additional controllers can use NetGet functions to obtain this data as well. Bit Description 1-12 Digital Inputs Data from the digital inputs 33-48 Status and Diagnostic Data 49-56 Firmware Version 57-64 Device Class 56 for the MIX102 Produced Analog Data This data is sent from the SmartBlock to the controller. Normally this data is mapped into specific registers in the I/O configuration in Cscape. For advanced applications NetGet functions can be used to obtain this data. Since this data is broadcast to all controllers on the network additional controllers can use NetGet functions to obtain this data as well. Word Function Word 1 INT Analog Input 1 Data Word 2 INT Analog Input 2 Data Word 3 INT Analog Input 3 Data Word 4 INT Analog Input 4 Data

MAN0959-01 PAGE 6 Mix102 module 6 INSTALLATION / SAFETY Warning: Remove power from the OCS controller, CAN port, and any peripheral equipment connected to this local system before adding or replacing this or any module a) All applicable codes and standards should be followed in the installation of this product. b) Shielded, twisted-pair wiring should be used for best performance. c) Shields are to be terminated to frame ground. d) In severe applications, shields should be tied directly to the ground block within the panel. e) Ungrounded thermocouple sensors are preferred due to their isolated electrical characteristics f) Interposing terminal strips between the sensor and the module can cause errors due to cold junction effect. g) If Interposing terminal strips must be used, use specially constructed terminal blocks, which match the material characteristics of the thermocouple sensor. h) Horner thermocouple input modules use a high impedance differential circuit to support the use of grounded or ungrounded thermocouples. For grounded thermocouples, the specified Common Mode Range allows for ground potential differences between the machine ground and the PLC ground within that range. For ungrounded or floating thermocouples the high impedance inputs are subject to common mode noise pickup. For noisy environments it is recommended that one side of all ungrounded thermocouples be grounded near the PLC. This does not affect open thermocouple detection or measurement accuracy and reduces the effect of common mode noise if present. This PLC side ground connection must not be used with grounded thermocouples or accuracy will be affected. Any thermocouple should be grounded in one place at most. When found on the product, the following symbols specify: Warning: Consult user documentation. Warning: Electrical Shock Hazard. WARNING: To avoid the risk of electric shock or burns, always connect the safety (or earth) ground before making any other connections. WARNING: To reduce the risk of fire, electrical shock, or physical injury it is strongly recommended to fuse the voltage measurement inputs. Be sure to locate fuses as close to the source as possible. WARNING: Replace fuse with the same type and rating to provide protection against risk of fire and shock hazards. WARNING: In the event of repeated failure, do not replace the fuse again as a repeated failure indicates a defective condition that will not clear by replacing the fuse. WARNING: Only qualified electrical personnel familiar with the construction and operation of this equipment and the hazards involved should install, adjust, operate, or service this equipment. Read and understand this manual and other applicable manuals in their entirety before proceeding. Failure to observe this precaution could result in severe bodily injury or loss of life. All applicable codes and standards need to be followed in the installation of this product. For I/O wiring (discrete), use the following wire type or equivalent: Belden 9918, 18 AWG or larger.

MAN0959-01 PAGE 7 Mix102 module Adhere to the following safety precautions whenever any type of connection is made to the module. Connect the green safety (earth) ground first before making any other connections. When connecting to electric circuits or pulse-initiating equipment, open their related breakers. Do not make connections to live power lines. Make connections to the module first; then connect to the circuit to be monitored. Route power wires in a safe manner in accordance with good practice and local codes. Wear proper personal protective equipment including safety glasses and insulated gloves when making connections to power circuits. Ensure hands, shoes, and floor are dry before making any connection to a power line. Make sure the unit is turned OFF before making connection to terminals. Make sure all circuits are de-energized before making connections. Before each use, inspect all cables for breaks or cracks in the insulation. Replace immediately if defective. 7 TECHNICAL SUPPORT North America: Tel: 317 916-4274 Fax: 317 639-4279 Web: http://www.heapg.com Email: techsppt@heapg.com Europe: Tel: +353-21-4321266 Fax: +353-21-4321826 Web: http://www.horner-apg.com Email: tech.support@horner-apg.com Cscape, SmartStix and CsCAN are trademarks of Horner APG. This information is subject to change without notice.