Air-Cooled Series R Chiller

Similar documents
DOWNLOAD OR READ : TRANE RTAC 155 BINDIG MANUAL PDF EBOOK EPUB MOBI

Trane mytest Water-cooled Chiller Performance Validation What you spec is what you get *

CGWN/CCUN indoor liquid chillers The compact AquaStream² solution

CGAM air-cooled scroll chiller. Highly efficient, yet extremely quiet

Trailblazer AGZ-E air-cooled scroll chillers

Trane Cold Generator TM. Scroll Chillers. Comfort and Process Cooling Solutions

VARIABLE REFRIGERANT FLOW SYSTEMS HITACHI SMARTFLEX VRF GEN II FLEXIBILITY, PERFORMANCE AND CONTROL

glide glider kw R134a air cooled liquid chillers AND free cooling chillers FREE COOLING SHELL A C CLASS E C Energy Class RCGROUP SpA

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant

Supplement to PM WSC/WDC-1 MicroTech II for Centrifugal Compressor Water Chillers

Adaptive Frequency Drive Superior Chiller Performance

APPLIED SYSTEM AWS FAMILY FOR LARGE APPLICATIONS PRODUCT LEAFLET. Capacity from 600 to 2,010kWr. Engineered for flexibility and performance

Magnitude magnetic bearing centrifugal chillers

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

Magnitude magnetic bearing centrifugal chillers

Tracer Controls. Tracer MP.501 Controller BAS-PRC008-EN. June 2001

Magnitude magnetic bearing centrifugal chillers

Trane Series S CenTraVac Chillers with AdaptiSpeed Technology tons

Precision Cooling for Business-Critical Continuity. Liebert HPC-S. Designed for the Efficient Cooling of Small Data Centers

CHAPTER/REGIONAL TECHNOLOGY AWARD - SHORT FORM

Aquaflair. Uniflair TRAC, TRAF and TRAH. Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors.

HYFRA Sigma. Efficient, reliable cooling water recooling systems. Customized. Cooling. Solutions.

The Future. Today. YZ MAGNETIC BEARING CENTRIFUGAL CHILLER

Digital Realty Data Center Solutions Digital Chicago Datacampus Franklin Park, Illinois Owner: Digital Realty Trust Engineer of Record: ESD Architect

Tracer Controls. Tracer MP501 Controller BAS-PRC008-EN. January 2005

Air-Cooled Chillers. R134a. Performance Matters

Designing Ultra-Efficient Building Cooling Systems

Series S CenTraVac Chillers Leading efficiency and proven reliability BEYOND EFFICIENCY. BEYOND RELIABILITY. BEYOND SUSTAINABILITY. LET S GO BEYOND.

Pathfinder AWV air-cooled screw chillers

DEDICATED HEAT RECOVERY UNIT (DHRC)

Tracer Controllers. Tracer MP503 Input/Output Module BAS-PRC009-EN. September 2001

30XAV & 30XWV. Air and water-sourced, variable-speed screw units. AquaForce with Greenspeed intelligence, Because you should not have to choose.

AIR-COOLED A (Surprisingly) Cost-Effective Alternative to Water-Cooled Chiller Plants

Optimiz Chilled January 25, 2013

Precision Cooling. Precision Cooling Advantages

Tracer Controllers. Tracer MP503 Input/Output Module BAS-PRC009-EN. January 2005

HOURLY ANALYSIS PROGRAM v5.00 and v5.01

How To Draw Chiller Monsters Werewolves Vampires And Zombies

Next Generation DCP Optimization using MV VSDs

Chiller Replacement and System Strategy. Colin Berry Account Manager

Large Tonnage Chillers. Kingsley Hu Technical Support Engineer

HIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM.

Ecotel Free Cool 5-15kW

that may have a direct effect on your bottom line. The question

User Guide. FreeCool : Free Cooling unit V1.1 ENGY-SVU001A-GB

HIGH EFFICIENCY Central Chiller

Overview of Danfoss Turbocor. Danfoss Turbocor Learning Center M110_v4

Blue e+ chillers with the principle

Trane Controls. Smart Solutions for Smart Buildings

WHAT IS THE DIGI-RTU South 59 th Street Omaha, NE bes-tech.net

Tracer Controls. Tracer ZN517 Unitary Controller BAS-PRC012-EN

T66 Central Utility Building (CUB) Control System Reliability, Optimization & Demand Management

where we are, where we could be, how we can get there. 12/14/2011

EXCEEDING EXPECTATIONS

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

Hines Buildings. Phoenix, Arizona

Liebert DCW CATALOGUE

Airedale International Air Conditioning Limited. Leeds Road, Rawdon Leeds, LS19 6JY, England

DUCTED SPLIT SYSTEMS With Scroll compressors

COMMERCIAL AIR CONDITIONERS Flooded Type Water Cooled Screw Chiller 2012

MOLLIER DIAGRAM CAN BE IMPROVED!

Close-coupled cooling

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw

Commercial HVAC Efficiency Regulations and Refrigerants Are Changing: Are You Ready?

Liebert. HPC-S Free Cooling Chiller Designed for the Efficient Cooling of Small Data Centers

Carrier Previews AquaEdge 19DV Centrifugal Chiller with Environmentally Sustainable Refrigerant

Aquaflair. BREC & BREF kW 380V/3ph/60Hz - 460V/3ph/60Hz. Air-cooled chillers and free-cooling chillers with double screw compressors

Liebert Economizer Cooling Solutions Reduce Cooling Costs by up to 50% Without Compromising Reliability

Drives and motors. A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC)

Google s Green Data Centers: Network POP Case Study

Performance and Efficiency

Aquaflair. BREC/F and BCEC/F kw

GP SERIES Packaged Chillers

Drives and motors. A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC)

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

AuraCool Economizer System

Oil Free Magnetic Bearing Chillers. Lloyd Davis ESTech Energy Ltd

SCHENDT ENGINEERING PRIOR EXPERIENCE

INNOVATE DESIGN APPLY.

Trane Engineering News Chiller Plant Case Study: Variable-Primary Flow Series Chillers with Free Cooling

ASHRAE CHAPTER TECHNOLOGY AWARD Illinois Chapter, Region VI

User Guide. Multipipe Units CMAA / RTMA CNT-SVU004B-GB

INNOVATE DESIGN APPLY.

Efficiency of Data Center cooling

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

High Efficient Data Center Cooling

Comprehensive Energy Management & Utility Master Plan

Liebert DCW Family Chilled Water-Based High Density Cooling For The Data Center. Precision Cooling For Business-Critical Continuity

Liquid Cooling Package LCP Cooling Systems

Hvac Water Chillers And Cooling Towers Fundamentals Application And Operation Second Edition Mechanical Engineering

Liebert : The Right Cooling For IT Environments

LIFE CYCLE COST ANALYSIS, CRITERIA AND DATA SHEETS DOCUMENT NUMBER: APPLICATION: ELEMENTARY, MIDDLE AND HIGH SCHOOL

Precision Cooling Mission Critical Air Handling Units

PROCESS & DATA CENTER COOLING. How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES

District Cooling Marches on in Dubai The Emirates Towers Case Study

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

Product Catalog. Tracer Controller MP501 BAS-PRC008-EN. May 2012

Optimizing Chilled Water Plant Performance. David Herman, PE, LEED AP Principal EnerG Associates, LLC

CLIMATE. CUSTOMIZED. CyberHandler2 from 30KW to 520 KW. The indirect evaporative free-cooling Air Handling Unit

Data Center Energy and Cost Saving Evaluation

Transcription:

Air-Cooled Series R Chiller The next generation of Air-Cooled Helical Rotary Chillers ANOTHER RELIABLE SOURCE OF CHILLED WATER FROM TRANE

The new industry standard f The next generation of the air-cooled Series R chiller family. Air-Cooled Series R Chiller Model RTAC 140-500 Tons 60 Hz 120-400 Tons 50 Hz The Model RTAC is the second generation of the air-cooled Series R chiller family. The RTAC offers high reliability, reduced sound levels, improved energy efficiency, and a smaller physical footprint, all due to its advanced design, low speed/directdrive compressor, and proven Series R chiller performance. The Next Generation This most recent development is the advanced air-cooled chiller. It features a new generation of compressors, improved acoustic performance, and a smaller footprint for the same capacity. Reliability Less Downtime and Maintenance The Trane Company is the world s largest manufacturer of large helical rotary compressors. Continuous extensive research and development, testing and advanced manufacturing processes provide the most reliable compressor in the air conditioning and refrigeration industry. Tens of thousands of commercial and industrial installations (over 100,000 compressors) worldwide have proven that the Trane helical rotary compressor has an unequaled reliability rate of 99.5 percent in the first year of operation. How does Trane achieve these worldclass standards? The Trane Series R chiller uses a direct-drive, low speed, semihermetic compressor design with fewer moving parts than other compressors available on the market. The reliability and well-known life span justify their commercial success: more than 100,000 Trane helical rotary screw compressors are operating in the world. Trane has proven the best way to obtain the best performances and reliability lies in the development of a specific compressor. Fewer moving parts, fewer critical components, simple design, and over 14 years of manufacturing know-how are the ingredients for the quality and reliability of Trane helical rotary compressor water chillers. 2001 American Standard Inc. All rights reserved

or reliability, sound, efficiency, and size. Sound Improved Acoustical Performance The Trane Company has a proven track record of continuously improving the sound levels of our water chillers. One of the primary design goals of the RTAC was to further reduce sound levels over previous marketplace designs. This goal was met by designing the compressor to minimize sound generation and by optimizing and isolating chiller components to reduce sound propagation throughout the system. The result is a new acoustical standard for air-cooled chillers. The sound levels of the Series R Model RTAA air-cooled chillers have been steadily improved since introduction. With the advent of the Model RTAC, sound levels are reduced significantly by addressing three major sources: the compressor, the refrigerant piping, and the condenser fans. The compressor has been designed to minimize sound at its point of creation. In addition, the refrigerant components and piping have been optimized to reduce sound propagation throughout the system. A third source of sound originates from the condenser fans. This sound power can be as much as half of the overall unit sound power levels. Careful consideration was taken when designing and selecting the next generation condenser fans to be engineered into the Model RTAC. The sound levels achieved on the RTAC represent the lowest sound levels ever on Trane air-cooled screw compressor water chillers. The compact size of the RTAC unit makes it an excellent choice for new buildings or replacement of older chillers. Efficiency Lower Operating Costs The use of advanced heat transfer technology has allowed the Series R chiller to achieve record energy efficiency levels. Trane offers superior full-load performance and optimized part-load performance. Energy efficiencies above 10.8 EER at ARI conditions means that the RTAC is the most efficient air-cooled chiller available. Using a compressor which has infinite unloading and can match the cooling load exactly can further reduce energy consumption. Not all helical rotary compressors are the same. Some screw compressors have step unloading similar to reciprocating compressors of the past. Under partload conditions, these chillers would typically be overcooling or undercooling the chilled water. This results in increased chiller operating costs and unwanted variations in chilled water supply temperatures. The Series R compressor unloads the chiller smoothly and allows it to closely match a building s cooling needs or an industrial process load. This increases control over the chilled water temperature, at the same time reducing annual operating costs. Size Ease of Installation The compact aircooled Series R chiller is an excellent choice for any retrofit or replacement job. It is smaller than most of the chillers it might replace and an easier fit into the layout and landscaping of existing buildings. In addition, the unit design allows for installations where the condenser coils are only four feet from a wall with no performance reductions. More compact than most of the chillers available on the market, it is equally suited to new buildings as well as the replacement market. In an installation where space is limited, the RTAC can operate with a relatively narrow gap in front of the condenser causing only a minor capacity derate. Units come from the factory fully charged with refrigerant and oil. Extensive factory testing helps ensure trouble-free startup, resulting in lower installation costs and a faster startup. Controls Trane s Adaptive Control microprocessor is the most advanced chiller controller available in the industry today. It offers internal control logic that monitors the chiller s operation and keeps it running during extreme operating conditions. While controls on other chillers will shut down machine operation, the Trane Series R chiller will modulate system components to keep the chiller online producing chilled water, meanwhile continuing to optimize chiller performance. The Tracer chiller controller microprocessor has two operator

DynaView display unit. interfaces, the EasyView with a built-in display unit placed in the front of the control panel and the optional DynaView, which is a true man/machine interface. DynaView enables the user to monitor operation of the machine quickly and easily. The Tracer chiller controls of the Model RTAC offers several communication levels that considerably simplify the implementation of telemonitoring of the chiller or its integration into a Building Management System (BMS). Ownership Value The Model RTAC air-cooled chiller was designed to meet the demanding requirements of today s environment. The high-technology design transforms An RTAC chiller integrates easily into your overall comfort strategy. technology into the performance you can depend on. For example, its semihermetic, direct-drive compressor eliminates the need for a gearbox, a common component in many competitive chillers. This improves the unit s reliability, energy efficiency, and significantly aids in reducing unit sound levels and vibration. Also, the Adaptive Control microprocessor aids in improving energyefficiency and provides more reliable operation by minimizing chiller downtime. This is accomplished with the microprocessor control, which continuously monitors the operating conditions of the chiller and automatically initiates corrective action, especially during adverse conditions. Trane chillers are known for their quality, reliability, and flexibility in a wide range of chilled-water systems. However, the chiller is but one component in any chilled-water system. Components such as the pumps, valves, filters, water quality, and controls

Whatever your operating environment, this chiller is made for it. can adversely affect the performance of any system. Proper maintenance of the entire chilled-water system is necessary to yield many years of predictable performance. Trane recommends that a preventive maintenance program be established with a professional service organization. A trained professional can help you maintain optimum performance in the chiller and the rest of the chilled-water system, year after year, so you can realize the performance you need. The Trane Company, with over 220 Customer Solutions and Services Centers located around the world, is uniquely positioned as the professional service organization that can provide you with a wide range of solution support for your complete environmental system. Refrigerant The Trane Company is committed to providing the right refrigerant in the right equipment at the right time. Trane, along with ASHRAE, ARI, and the U.S. EPA, actively supports all three major chiller alternative refrigerants: HCFC-22, HCFC-123, and HFC-134a. The Model RTAC chiller was specifically engineered to use the medium pressure alternative refrigerant HFC-134a. This choice allows the RTAC to meet worldclass chiller design criteria for reliability, efficiency, size, and acoustic performance. Applications RTAC is a chiller designed for the Industrial and Commercial market. RTAC is also a chiller designed for all climates, with high and low ambient units available. This flexibility in the application of the Series R chiller makes it ideal for office buildings, hospitals, schools, internet and telecommunications service providers and industrial applications. Comfort Cooling Industrial Process Cooling Ice/Thermal Storage Low Temperature Process Cooling Control Strategies The Integrated Comfort System With Tracer Summit building management, building owners and operators get powerful control, diagnostics, monitoring, and reports; extending from individual chillers to the chiller plant, or to the entire comfort system. In addition, an Integrated Comfort System provides: Optimized Operating Costs A Consistently Comfortable Environment The Reliability of Direct Digital Controls Efficiency from Pre-tested Energy Management Strategies Single Source Manufacture, Warranty, and Service Quality The Trane Company s water chiller systems business unit in Pueblo, Colorado is an ISO 9001 Certified facility. This level of dedication to quality is what chiller owners have come to expect from Trane chillers. Each Series R chiller goes through extensive factory testing to dramatically reduce startup problems.

The Trane Company An American Standard Company www.trane.com For more information contact your local district office or e-mail us at comfort@trane.com Literature Order Number RLC-SLB003-EN Date August 2001 Supersedes Stocking Location RLC-SLB003-EN-0800 La Crosse Since The Trane Company has a policy of continuous product and product data improvement, it reserves the right to change design and specifications without notice.