Excel 500 XCL5010 CONTROL SYSTEM

Similar documents
LION System. Product Data. Copyright 2007 Honeywell GmbH All Rights Reserved 3.4

EAGLE Controller. Product Data

Excel 800 SYSTEM HONEYWELL EXCEL 5000 OPEN SYSTEM SPECIFICATION DATA. U.S. Registered Trademark Copyright 2011 Honeywell Inc. All Rights Reserved

EAGLEHAWK Controller. Product Data. U.S. Registered Trademark Copyright 2016 Honeywell Inc. All Rights Reserved

Separate mounting base for easy installation. Tamper resistant locking cover.

Onboard Inputs and Outputs. Remote User Interface. Integral LCD User Interface

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

EAGLEHAWK Controller. Product Data. U.S. Registered Trademark Copyright 2016 Honeywell Inc. All Rights Reserved

Smart Equipment Controls (SEC)

T7560A,B,C Digital Wall Module

clarity 3 Programmable Controller

TAC Xenta 301. Controller, Freely Programmable

Excel 10 Q7750A ZONE MANAGER BEFORE INSTALLATION. Parts Checklist INSTALLATION INSTRUCTIONS

BACnet. b3810 Series Local Controllers

EAGLEHAWK Controller. Product Data. U.S. Registered Trademark Copyright 2018 Honeywell Inc. All Rights Reserved

N20010-SER. NON-SPRING RETURN DAMPER ACTUATOR 20 Nm (177 lb-in) FOR ADJUSTABLE MODULATING CONTROL SPECIFICATIONS GENERAL FEATURES PRODUCT DATA

Andover ContinuumTM Infinet II

LX Series Free Programmable Controllers

EXOcompact. Freely programmable controller

NIEx9. Metasys. BAS network automation Supervisory controllers. Network Integration Engine

NEUROLOGIC RESEARCH CORPORATION MODEL 2500

TAC Xenta 121-FC Programmable Fan Coil Application

NAE. Metasys. BAS network automation Supervisory controllers. Network Automation Engine

XM500 TCP/IP MODEM FEATURES GENERAL DESCRIPTION PRODUCT DATA

LON Module for Variable Speed Drive

The Simply Smart Way to Optimize Building Control and Performance

Unitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000

Satchwell MicroNet. Building Management System MicroNet 50 Series

TAC Xenta 121-HP Programmable Heat Pump Application

Overview. Seen as an extension of the main HVAC controller when configuring, allowing you to save engineering time.

XL 800 Series FOR SMOKE CONTROL

PXR11 PXR12. System controllers DESIGO PX

connecdim Gateway G1 Ethernet TCP/IP to DALI

HAWK 8000 Controller GENERAL. Product Data. Fig. 1. HAWK 8000

LX Series Remote Input/Output (I/O) Controller

Medium User Interface (MUI) Version 3

EAGLEHAWK NX Controller

Andover ContinuumTM. b3850 Series Terminal Controllers

DS October MAXIM 1010 Controller

Controller module. Brief description. Features. Block structure. Data Sheet Page 1/7

our experience...your solution Controlling and Monitoring Gateway

TAC Xenta 101-VF. 3-Speed Fan Coil Controller. TAC Xenta

T7560A,B,C Digital Wall Module

pco sistema programmable controllers Technology & Evolution

IQ21x Series Controllers

Andover ContinuumTM Infinet II

T7560A,B,C Digital Wall Module

CTR21, CTR22, CTR23, and CTR24 Wall Modules

WEB-EAGLEAX26 Controller

DS BAS 08/99 UNC 532

DS Type: MAXIM III Controller

C7110C1001A / C7110D1009A WALL MODULES

pco5 Overview February 2010 Air Conditioning Business Unit pco5 Overview slide n. 1

M-Bus Central Unit. Use

SB2WEB24. SB2WEB BACnet Controller. Benefits. Description

Overview. Seen as an extension of the main HVAC controller when configuring, allowing you to save engineering time.

APP 700 Technical Specification

Excel Smart I/O Compact

FX06 Field Controller

Excel 800 LION SYSTEM HONEYWELL EXCEL 5000 OPEN SYSTEM INSTALLATION AND COMMISSIONING INSTRUCTIONS CONTENTS

FX Input/Output (I/O) Modules XM07 and XM14

Controller module. Brief description. Features. Block structure. Page 1/7. Data Sheet

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

PHARAO. Compact controllers for installation and automation technology

Compact I/O Module XIO-4AO LON ANALOG OUTPUT MODULE

M7410G LINEAR VALVE ACTUATOR WITH LON CAPABILITIES

BACnet. b3867 Terminal Controllers

1201L-1K RTD Controller. Revision 1.1. Nico Technology Ltd. 1 Rev.1.1

BUILDING MANAGEMENT. OpenBAS-HV-NX10 SERIES CATALOG NUMBER. Description. Features

Products no longer available

Note: the wiring of the dead-man buttons has been changed since October 2001.

Metasys N1 Network Integration

INSTALLATION AND COMMISSIONING INSTRUCTIONS CONTENTS

Excel Web II Control System

Andover ContinuumTM Infinet II

INSTALLATION INSTRUCTIONS

Excel Web XL1000B/C TABLE OF CONTENTS HONEYWELL EXCEL 5000 OPEN SYSTEM INSTALLATION INSTRUCTIONS

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Power Modular Equipment Controller

Installation Instructions for UL Rev A

Extruder Controls ExtruVision S

Excel Smart I/O Compact XFCL2A1 AND XFCL3A1

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

FEATURES DESCRIPTION MODEL 110B. Power Supply

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

LOCAL DISPLAY UNIT (LDU)

General information. Display. Supply voltage. Input current. Encoder supply. Output current

KS 108 easy Compact automation unit for industrial control and process technology

SA2WEB24. Central unit module. Benefits. Description

Carbon Monoxide (CO) Gas Detection and Control System

H7625A, H7635A Humidity/Temperature Sensors

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current

TC Modular Series for BACnet Networks

ML7421A,B Electric Linear Valve Actuators

PEAK TM. PEAK TM controllers. Mid-Market BAS Smart equipment controllers. HVAC/R controllers

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

Transcription:

Excel 500 XCL5010 CONTROL SYSTEM SPECIFICATION DATA FEATURES GENERAL The Excel 500 is a freely programmable control and monitoring system designed specifically for building management. Using the latest Direct Digital Control (DDC) technology, the Excel 500's modular design is particularly well-suited for use in medium-sized buildings (e.g. schools, hotels, offices, shopping centers, and hospitals). With its LONW ORKS network interface, the Excel 500 is LONMARK compliant and offers a whole range of interoperability options. In addition to control applications for heating, ventilation, and air conditioning (HVAC), the Excel 500 also performs a wide range of energy management functions, including optimum start/stop, night purge, and maximum load demand. Up to four Building Supervisors can be connected via the system bus. A modem or ISDN terminal adapter can be connected directly to the XCL5010 for communication with a data transmission rate of up to 38.4 Kbaud via the public telephone network. The modular design enables the system to be expanded to meet growing needs. The data point user addresses and plain language descriptors are stored in the controller and are therefore available for viewing locally at an external interface without the need of a central PC. The Excel 500 is suitable for use in open LONW ORKS networks. Thus, in addition to its own I/O modules (see Table 1), an Excel 500 can operate on the same LONW ORKS bus as other Excel 500 controllers (each with its own I/O modules), Excel 10 and Excel 50 controllers, and other Honeywell and third-party LONW ORKS devices. U.S. Registered Trademark Copyright 2002 Honeywell Inc. All Rights Reserved Various state-of-the-art communication options: C-bus (between up to 30 Excel 500 controllers) or Open LONW ORKS bus communication; modem or ISDN terminal adapter at up to 38.4 Kbaud; wireless communication via GSM; dial-up through TCP/IP networks Unique features in open LONWORKS networks: NVBooster reduces the number of required NVs and thus also the number of required controllers; NV bindings can be restored after controller reset (and thus need not be redone after exchanging controllers); 512 NVs supported for LONW ORKS integration; autobinding of Honeywell I/O modules makes NV binding unnecessary, thus saving considerable engineering effort Typically, 190 physical inputs/outputs can be controlled via network variables in a LONW ORKS network 128 physical data points, 256 pseudo data points, and up to 16 Distributed I/O modules per Excel 500 controller (Cbus communication) DIN-rail mounting (e.g. in control cabinet) Applications programmable with Honeywell's CARE programming tool and downloadable into Flash EPROM Enhanced controller functions including: alarm, trend and global broadcast hysteresis, network-wide time synchronization, firmware downloading via modem and C-bus Internal power supply module Shared transformer (CPU and Distributed I/O modules connected to the same transformer) Optimum access to terminals NOTE: The XCL5010 has no internal display; thus, an XI582AH operator interface or PC-based Excel Online (formerly XI584) operator and service software is needed when interfacing. Table 1. Modules for the Excel 500 (XCL5010) System Modules XCL5010 XFL521/B XFL522A/B XFL523/B XFL524A/B XFCxxxxxx Description Computer module Excel 500 (supports Distributed and Smart I/O), incl. power supply and communication; UL916-approved Analog input module Analog output module Digital input module Digital output module Smart I/O modules NOTE: See also Distributed I/O Specification Data (EN0B0090GE51) and Smart I/O Product Data (EN0B0311GE51) for more information. EN0B-0203GE51 R0802 74-3666

DESCRIPTION The Excel 500 System is part of Honeywell's EXCEL 5000 family of controllers. The Excel 500 is freely programmable and can be used as a stand-alone controller or as part of a network. The Excel 500 System provides energy management and control functions via LONWORKS bus to Honeywell LonWorks I/O modules, 3 rd -party LonWorks I/O modules, or 3 rd -party LonWorks devices. NOTE: The XCL5010 CPU can use only external I/O modules. There is no possibility of connecting internal plug-in I/O modules. The Excel 500 can communicate with any LONWORKS product. Up to 512 LONWORKS network variables can be mapped to internal data points. SPECIFICATIONS Electrical Operating voltage 24 Vac/dc, ± 20% Power consumption Max. 5 VA (max. 4 W) Memory buffer In case of power failure, the super gold capacitor saves RAM content and real-time clock for 72 hours (environmentally friendly; no problems disposing of dead batteries). Overvoltage protection All inputs and outputs are protected against 24 Vac and 40 Vdc overvoltage as well as short-circuiting. Terminal 2 of the screw terminal block is protected by a quick-acting 4-A fuse behind the terminal block. Environmental Ambient temperature Operation: 32...122 F (0...50 C) Storage: -4...+158 F (-20...+70 C) Ambient humidity (operation and storage) 5 to 93% r.h. non-condensing Mechanical Housing dimensions (H x W x D) 5.90 x 7.79 x 3.82 in. (150 x 198 x 97 mm) Housing material Plastic, flame-retardant Mounting methods DIN-rail mounting (e.g. in control cabinet) Calculated lifetime of weakest components MTBF 13.7 years Protection class IP 30 There are three sources for Excel 500 program applications: 1. Standard HVAC technology applications can be assembled as needed using Honeywell's Windows-based CARE programming tool. 2. Excel 500 application programs can be freely programmed using CARE. The user program is then automatically generated based on the graphically designed schematic diagram, instrumentation, and control strategies. 3. A set of predefined applications (MODAL) is available in order to provide state-of-the-art applications without the need of programming. Memory 64 KB EPROM (boot) 256 KB RAM 1 MB Flash EPROM (firmware and application) 4 K bit EEPROM Communication C-Bus The C-bus transmits data between the EXCEL 5000 System controllers, gateways to 3 rd -party systems, and building supervisors at 9.6 Kbaud up to 76.8 Kbaud. The max. C-bus network length is 1,200 m (3,900 ft.) or 15,700 ft. (4,800 m) using the XD509 repeater. A switch is provided for selectable termination. There is a max. of 30 controllers or devices per C-bus. See Excel 500/600 Installation Instructions (EN1R-1047GE51) for wiring details. LONWORKS Bus The Excel 500 uses an FTT-10A Free Topology Transceiver, transmitting data at 78 Kbaud using LonTalk protocol. Cable length from 1,050 to 7,200 ft. (320 to 2,200 m). See Excel 500/600 Installation Instructions (EN1R-1047GE51) for wiring details. External Interface / Modem A 9-pin Sub-D connector, RS232, is provided as a serial port to connect an external interface (e.g. the XI582AH operator interface or the PC-based XI584 operator and service software) or a modem or ISDN terminal adapter for dial-up access at a transmission rate of up to 38.4 Kbaud. EXCEL 500- XCL5010 HOUSING COMMUNICATION MODULE C-BUS CONNECTOR LON-BUS CONNECTOR Comm_Prt SERIAL PORT FOR EXTERNAL MMI, MODEM, OR ISDN TERMINAL ADAPTER EN0B-0203GE51 R0802 2

Communication Module XDL505 Housing Plug-in plastic module. Communication Module LEDs and Ports LON SERVICE BUTTON POWER, GRN LON SERVICE, RED C-BUS TxD, YEL C-BUS RxD, YEL RESERVED C-BUS TERMINATION SWITCH LEDs Assignment Terminal Block 24 Vac 24 Vac DO NOT USE! 1 2 3 4 5 6 7 8 9 10 11 12 13 14 24 Vac 24 Vac Term_Ass 1 2 3 4 5 6 LON BUS A1 A2 NOT USED SHIELD C + C - C-BUS 00000124 Terminal Block Excel 500 (XCL5010) RESET BUTTON Term_Blk SCREW TERMINAL BLOCK (REMOVABLE) REMOVABLE FUSE BELOW TERMINAL BLOCK COMMUNICATION MODULE (REMOVABLE) 3 EN0B-0203GE51 R0802

EXTERNAL I/O MODULES See the Specification Data sheets for Distributed I/O (EN0B-0090GE51) and Smart I/O (EN0B-0311GE51). OPERATOR INTERFACE XI582AH Fig. 1. The XI582AH Operator Interface The XI582AH operator interface is the command and information center of the Excel 500 system. With it, data can be entered and displayed. Information such as current temperature values, control status, etc. can also be displayed. The menu-driven, 6-line, backlit LCD graphic display with 34 characters per line, together with eight clearly marked keys, makes the device easy to use. The operator interface is connected to the serial port next to the communication module. The XI582AH can be mounted up to 48 ft. (15 m) away from the controller. This can be extended to 328 ft. (100 m) using line drivers. OPERATOR AND SERVICE SOFTWARE EXCEL ONLINE (FORMERLY XI584) The PC-based Excel Online (formerly XI584) is the local intelligent operating and service software. It performs all the operating functions of the XI581AH/XI582AH as well as having the advantages of a PC. Not only can the Excel Online (formerly XI584) make major modifications such as changing setpoint values and time program switching points, it also offers all service and commissioning functions. XI584con Fig. 2. Excel 500 (XCL5010) with XI584 and printer The Excel Online (formerly XI584) can be operated at five different access levels, three of which are passwordprotected. A printer can be connected to the parallel interface of the Excel Online (formerly XI584) to log alarms and error messages. As with the XI582AH, the PC with the Excel Online (formerly XI584) operator and service software can be placed up to 15 meters from the computer module. Line drivers allow distances of up to 328 ft. (100 m). PROGRAMMING The Excel 500 system includes a comprehensive software package specially designed to meet the requirements of application engineers. The easy to use, menu-driven software features the following functions: data point description time program alarm handling application program (DDC program) password protection Data Point Description Data points are the basis of the Excel 500 system. They contain system-specific information such as values, status, limit values, and default settings. The user has easy access to data points and the information that they contain. The user can recall and modify information in the data points. In the case of LONWORKS applications, up to 512 NVs can be created. Time Program The time program can be used to enter the setpoint or status at any time for any data point. The following time programs are available: daily program weekly program annual program TODAY function special day list Daily programs are used to create a weekly program. The annual program is created automatically by multiplying the weekly program and then incorporating daily programs. The TODAY function allows direct changes to the switching program. It allows you to allocate a setpoint or status to the selected data point for a defined period of time. EN0B-0203GE51 R0802 4

Alarm Handling The alarm handling facility offers system security. Alarm signals can, for example, alert the operator to scheduled maintenance work. All alarms that occur are stored in data files and reported immediately. If your system configuration allows, you can also list alarms on a printer or transmit alarms to higher-level devices via the local bus or a modem. There are two types of alarms, critical and non-critical. Critical alarms (e.g. system alarms caused by a fault in the controller) have priority over non-critical alarms. To distinguish between alarm types, you can generate your own alarm messages or use pre-programmed system messages. The following events all generate alarm messages: exceeding limit values overdue maintenance work totalizer readings digital data point changes of state ACCESSORIES Table 2 lists the accessories which are available for the Excel 500 (XCL5010). Table 2. Accessories for the Excel 500 (XCL5010) Order code Description XD509 C-bus repeater XI582AH operator interface XW582 cable to XI582AH, 15 ft. (5 m) XW585 cable to XI584, 15 ft. (5 m) Pair of DIN-rail mounting clips XL50-ACC2 NOTE: One pair of DIN-rail mounting clips is included in each Excel 500 package Application Program (DDC program) You can use the Honeywell CARE (Computer Aided Regulation Engineering) programming tool to create application programs for your system. A particular advantage offered by CARE is the ability to create a fully functional control program without needing to be familiar with the programming language. A set of predefined applications (MODAL) is available in order to provide state-of-the-art applications without the need of programming. Password Protection The control system is also protected by passwords. This ensures that only authorized persons have access to system data. There are four operator levels, each protected by its own password. Operator level 1: Read only. The operator can display information about setpoints, switching points, and operating hours. Operator level 2: Read and make limited changes. The operator can display system information and modify certain pre-set values. Operator level 3: Read and make changes. System information can be displayed and modified. Operator level 4: Programming can be carried out. Trending The Excel 500 system provides controller-based trending. This feature allows historical values to be stored in the controller. Both time-based or value-hysteresis-based trending are possible. 5 EN0B-0203GE51 R0802

Dimensions 7.79 in. (198 mm) 0000042b 5.90 in. (150 mm) PORT FOR SCREW TERMINAL BLOCK PORT FOR COMMUNICATION MODULE FUSE HARDWARE RESET SERIAL -PORT 1.34 in. (34 mm) DIN-RAIL MOUNTING CLIP COMMUNICATION MODULE 3.94 in. (100 mm) 3.34 in. (85 mm) LON-BUS PORT C-BUS PORT 2.83 in. (72 mm) 3.82 in. (97 mm) 4.96 in. (126 mm) EN0B-0203GE51 R0802 6

7 EN0B-0203GE51 R0802

By using this Honeywell literature, you agree that Honeywell will have no liability for any damages arising out of your use or modification to, the literature. You will defend and indemnify Honeywell, its affiliates and subsidiaries, from and against any liability, cost, or damages, including attorneys fees, arising out of, or resulting from, any modification to the literature by you. Control Products Control Products Control Products Honeywell Inc. Honeywell Limited-Honeywell Limitee Honeywell AG Honeywell Plaza 155 Gordon Baker Road Böblinger Straβe 17 Manufacturing P.O. Box 524 North York, Ontario D-71101 Schönaich location certified to Minneapolis, MN 55408-0524 M2H 3N7 Germany USA Canada http://europe.hbc.honeywell.com EN0B-0203GE51 R0802 printed in Germany Subject to change without notice 74-3666