HUMLOG 10. Manual. Status V4 (02/2010)

Similar documents
GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

Humidity + Temp. + Dew Point Pocket size HUMIDITY METER. Model : HT-315

Operation Manual SuperDry Data Logger (SDDL)

RH/Temperature SD Card Datalogger. Instruction Manual

OPERATION MANUAL. SD card real time datalogger HUMIDITY/TEMP. MONITOR. Model : MHT-381SD

one probe, SD card real time data recorder CO2, %RH, Temp., Dew point, Wet bulb CO2 METER + HUMIDITY/Temp. Model : CO2-9914SD

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 100. T-Logg 100 E

SD Model. Instruction Manual. Humidity/Temperature Datalogger. reedinstruments

Temperature & Humidity Datalogger

User's Guide. Temperature / Humidity Datalogger. Model 42270

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 120 W -... T-Logg 120 K -...

12 channels TEMPERATURE RECORDER Model : BTM-4208SD

OPERATION MANUAL. SD card real time datalogger 3 channels 4-20 ma CURRENT RECORDER. Model : MMA-386SD


RS Stock No Instruction Manual RS Input Data Logging Thermometer

Temperature logger with internal sensor Instruction manual

Moisture Content Meter Plus Dew Point, Wet Bulb, and Thermocouple Temperature functions

Humidity & Temperature Datalogger

Sound Analyser Real Time 1/1 & 1/3 Octave band Analysis

OPERATION MANUAL. Carbon monoxide 0 to 1000 PPM, Temp. CO METER. Model : GCO-2008

Vibration Meter SD Card real-time datalogger

12-Channel Thermocouple Datalogger

Prime Capsule Portable Data Logger

DPL4000 Portable Low Range Dew Point Analyzer

Hygro-Thermometer / Datalogger


Installation and User Guide. idim Remote Control (304) Product description

OM-DLTT DATA LOGGER INSTRUCTIONS

Temperature logger with display Instruction Manual

INSTRUCTION MANUAL FOR TQ-8800 TORQUE METER PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

OPERATION MANUAL. SD card real time datalogger 3 Channels TEMPERATURE DATA RECORDER. Model : MTM-380SD. Your purchase of this 3

Eltek TU GenII AQ110A comprehensive portable air quality monitor transmitter

Dual channel temperature logger with display Instruction Manual

Brief instructions. ERSA soldering station

AC/DC MAGNETIC METER

OPERATION MANUAL. UVA and UVB measurement UV LIGHT METER. Model : YK-35UV

Application Note. E2 Interface for EE871, EE892 and EE893

OPERATION MANUAL. UVA and UVB measurement UV LIGHT METER. Model : YK-35UV

GB/UK. Operating manual. Data logger EBI USB

Manual Digital Thermometer PCE-T 390

RS Stock No Instruction Manual RS Input Data Logging Thermometer

Dual channel temperature logger with two voltage inputs 0-5V Instruction Manual

Please take serious note of the following warnings:

Datalogging Conductivity/ TDS Meter. Instruction Manual

Electro-Mechanical Counters

Visible Light SD Card Datalogger

3-Axis G-Force Datalogger

TES-1358 INSTRUCTION MANUAL

User Guide. Model Temperature Datalogger Kit Model Temperature and Humidity Datalogger Kit Model SW276 Datalogging Software SW276

OPERATION MANUAL. SD card real time data Recorder, USB/RS232 SOUND LEVEL METER. Model : SL-4023SD. Your purchase of this

OPERATION MANUAL. SD card real time datalogger, RS232/USB PRESSURE METER. Model : PS-9303SD. Your purchase of this PRESSURE METER with

3 in 1, Type K/J, Pt 100 ohm, Infrared Thermometer Real time data logger, Data logger no., RS232 THERMOMETER.

Humidity + Temperature + Pressure Datalogger

User Manual. Dual-Input Data Logging Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model

Anemometer SD Card Datalogger. Instruction Manual

OM-DLTH DATA LOGGER INSTRUCTIONS

OPERATION MANUAL. separate probe, RS-232 SOUND LEVEL METER. Model : SL-4013

sensor, which compensates for ageing effects, is highly insensitive to pollution and offers outstanding long term stability.

AC/DC MAGNETIC METER OPERATION MANUAL. Model : MG G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this

Quick Start Guide. Data Logger TrueLog100

Light Meter SD Card real-time datalogger

LED LIGHT METER OPERATION MANUAL. Model : LX-1148SD. SD card real time Data Recorder 10 Light Source select, Auto range 0 to 50,000 LUX

BESANTEK USB Data Logger Instructional Manual (BST-DL10, BST-DL13, BST-DL14)

HH-521BT 4-Channel Thermocouple Data Logger (with Bluetooth) (Types K, J, T, N, E, R, S) Instruction Manual

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

Datalogging Hygro-Thermometer

Operation Manual for Multifunctional Data Logger. HUATO Electronic Co., LTD.

Digital thermo-hygro-barometer with external probe Manual for use

AC/DC MAGNETIC METER OPERATION MANUAL. Model : PCE-MFM G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this

600 g x 0.02 g DIGITAL BALANCE

ph/orp Meter SD Card real-time Datalogger

Datalogging RH / Temperature Pen Instruction Manual

Manual SmartGraph for Humlog 10

Dual channel temperature logger with two binary inputs and LCD display Instruction Manual

testostor 171 Instruction manual

Datalogging Hygro-Thermometer

Brief instructions. ERSA soldering station

Manual Anemometer PCE-423

testo 176 Data loggers

4-Channel Thermometer / Datalogger

UVA LIGHT METER OPERATION MANUAL. Model : UVA-365SD. SD card real time datalogger + Type K/J thermometer

VIBRATION METER Model : VB-8213

3 Channel Datalogging Thermometer

4-Channel Vibration Datalogger

F %RH. %rf CO 2. g/m 3. inch H₂O. hpa. Measure. Record. Monitor. Choose the right data loggers for your application now.

USER MANUAL. Hygro-Thermometer. Model RHT510. Additional User Manual Translations available at

User's Guide. Datalogging Hygro-Thermometer Model SD500

The industrial humidity transmitter

Operating Instruction PPC-04 /2

EasyLog 21CFR Compatible Temperature, Humidity & Dew Point Data Logger with LCD Screen

testo 184 Data logger Instruction manual

LOCAL DISPLAY UNIT (LDU)

Hand-held thermometer Model CTH6200

PROFESSIONAL WIRELESS WEATHER STATION. Operation Manual - 1 -

User Manual. Heavy Duty Differential Pressure Manometer. Model SDL720. Additional User Manual Translations available at

SD Model. Instruction Manual. Heat Stress Meter and Datalogger. reedinstruments

High-Precision Pneumatic Pressure Controller Series CPC8000-L/-X

Model ST-618. Instruction Manual. Digital Thermo-Anemometer. Digital Measurement Metrology, Inc PRECISION IS OUR VISION

RS-232. ital Measurement Metrology, Inc ECISION IS OUR VISION LEVEL REC SETUP MAX MIN FAST SLOW INTV CLOCK.

COBEX RECORDERS, INC.

Transcription:

HUMLOG 10 Manual Status V4 (02/2010)

Contents 1 GENERAL 3 2 DISPLAY MODULE 4 3 HUMLOG 10 WITH INTERNAL SENSORS 6 4 HUMLOG 10 TSE FOR EXTERNAL SENSORS 7 5 HUMLOG 10 THC WITH INTERNAL SENSORS/WITHOUT DISPLAY 10 6 CHANGING THE SENSOR MODULE 14 7 CHANGING THE BATTERY 15 8 MOUNTING THE HUMLOG 10 16 9 SWITCHING ON THE HUMLOG 10 17 10 TIPS AND TRICKS 18 Page 2 of 18

1 General The HUMLOG 10 product family is a new development from the E+E ELEKTRONIK, which stands out from the field due to its excellent price / performance ratio. The compact design with its modular technology facilitates a multiplicity of applications. The measurement values can be read very well on the large display from a distance of several metres. HUMLOG 10 family: HUMLOG 10 = humidity/temperature internal HUMLOG 10 TSE = humidity/temperature external, with 2-channels to which either 2 temp. probes or 1 combined humidity/temp. probe can be connected HUMLOG 10 THC = humidity/temperature internal (without display) Due to its extremely low energy consumption and large memory, the product is excellently suited to long term measurement in both mobile and stationery applications. The SmartGraph 2 software, which is included with the product, offers the user an overview presentation and simple data archiving. With the professional version of SmartGraph 2, the values for temperature and dewpoint can be shown on the display optionally in C or F, and the humidity in % (relative humidity) or in g/m³ (absolute humidity). The technical data of the HUMLOG 10 can be found on the internet : http://www.epluse.com Page 3 of 18

2 Display Module The HUMLOG 10 generally consists of two modules: a Display Module and a Sensor Module. The memory, real time clock and the microprocessor controller are located on the Display Module. Alarm Channel 1 Channel 1 Unit Alarm Channel 2 Channel 2 Unit Special Functions REC: Recording On STOP: Recording Off Display: Preselection Mode: Active Display: Real Time Clock Alternative Display of date/time for the preselection or real time Format Date: 12.10 Format Time: 12:10 Illustration: HUMLOG 10 Display Elements Page 4 of 18

Explanations concerning the Display operation: When a pre-set limit has been exceeded the alarm symbol of the corresponding channel flashes. Once an alarm has been recognised, the alarm symbol remains visible on screen in static form even if the limit is no longer exceeded. The alarm message can only be eliminated by selecting Memory Readout on the PC. If the Pre-Selection mode (start flag) was selected, the start-date and start-time for data recording are shown on the Date/Time display. Once the pre-set date/time has been reached the start flag is eliminated, the real time clock display becomes active and data recording begins. The units m/s (Channel 1) and ppm / hpa (Channel 2) are reserved for other options. The special functions are reserved for other options. Page 5 of 18

3 HUMLOG 10 with Internal Sensors The sensors for temperature and relative humidity, the corresponding sensor adapters, and the serial interface (RS232) are located on this module. Illustration: Module with Internal Sensors Necessary calibration intervals are dependent on the environmental conditions and the requirements of the permissible tolerance deviations. A single point calibration of the internal sensors can be carried out using a comparison standard. The captured offset values can be entered in the SmartGraph software under: Measuring Instrument / Manage Measuring Instrument / Sensor Electronics. Two point calibrations can only be carried out in the factory. Page 6 of 18

4 HUMLOG 10 TSE for External Sensors The connectors for the external sensors, the corresponding sensor adapters and the serial interface (RS232) are located on this module. Illustration: Module for External Sensors Either one or two temperature sensors or one combined temperature/humidity sensors can be connected here. If only one external sensor is used this is connected to the left hand sensor socket. In order that the instrument may correctly recognise the association of the two temperature sensors to the channels, both sensor socket positions must first be unoccupied. If a sensor is connected to one of the two sockets, the indication UPLG (Unplug) appears in the corresponding line (Line 1= left hand socket, Line 2= right hand socket). If both socket positions are free, the indication SENS appears in the upper line, and the first temperature sensor can be connected to the left hand socket position. There are now 10 seconds available (Countdown on the display) to connect an second temperature sensor to the right hand socket position. Page 7 of 18

Instructions for probe exchange HUMLOG 10 TSE: 1.) Unplug the sensing probe. 2.) Separate display module from sensor module of basic unit HUMLOG 10 TSE. 3.) Display module indicates Fail. 4.) Connect sensor module with display module. Display indicates Sens. 5.) On the display a 10 sec.-counter is shown. Plug remote probe to sensor module within this time. 6.) Display indicates Init. HUMLOG 10 TSE reads calibration data out of the remote sensing probe. 7.) HUMLOG 10 TSE indicates now correct measurement values! Page 8 of 18

Instructions for using additional extensions for the probes: The probes are adjusted for the standard cable with a length of 2m. By using extension cables for the probes the accuracy of the measured relative humidity degrades. Using an additional extension cable with a length of 2m or 4m: no change of the humidity offset is necessary. Using an additional extension cable with a length of 6m: set an offset value of 0.8% in the software SmartGraph. Using an additional extension cable with a length of 8m or 10m: set an offset value of 1.8% in the software SmartGraph. Go into software SmartGraph and perform following step: - instrument -> configuration of instrument - select the instrument - sensors -> settings (relative humidity) - enter the offset as described above Necessary calibration intervals are dependent on the environmental conditions and the requirements of the permissible tolerance deviations. A single point calibration of the external sensors can be carried out using a comparison standard. The captured Offset values can be entered in the SmartGraph software under: Measuring Instrument / Manage Measuring Instrument / Sensor Electronics. Two point calibrations can only be carried out in the factory. Page 9 of 18

5 HUMLOG 10 THC with Internal Sensors/without Display General: the hardware of the HUMLOG10 compact is almost identical to the hardware of the HUMLOG10 with display. Two LEDs (a red and a green one) are used as a sub-stitute for the display to indicate the operation mode and the alarm. In addition, you will find close to the serial interface a start / stop button to switch on / off the datalogger. Operation mode / Alarm Serial interface Start-/ Stop button Page 10 of 18

Start/Stop function: the off / on button enables the HUMLOG10 to start and stop recording. The manual activation / deactivation of the datalogger and the configuration in start/stop or in ring mode are independent.. By pressing the off / on button, the HUMLOG10 will start recording ; by pressing it again, the HUMLOG10 will stop etc... Important: In the start / stop mode, the HUMLOG10 will start recording from the start date on (provided that this date is set in the HUMLOG) no matter if the start / stop button is being pressed during this time. Before the HUMLOG starts recording, it can be activated or deactivated too via the on / off button (s. timing diagram). Button On Button Off Logger On Logger Off LED Green LED Red Timing Diagram: HUMLOG 10 THC in ring mode Page 11 of 18

Programmed start date Button On Button Off Logger On Logger Off LED Green LED Red Timing Diagram: HUMLOG 10 THC in start-/stop mode The button should be kept pressed for approx. 1 sec. to start / stop the HUMLOG10. When activating the HUMLOG10, the green LED remains on during 3 sec. The red LED remains on during 3 sec. when deactivating the HUMLOG10. While recording, both LEDs on the HUMLOG10 or just one of them will flash at 10 sec interval. This time interval is completely independent of the recording and storage intervals set by the user in the HUMLOG10. Page 12 of 18

Alarm function: the datalogger is equipped with an alarm function on both channels (temperature and humidity) which enables the user to set minimum as well as maximum limit values. The red LED will flash in case of an alarm. If an alarm occurs while the HUMLOG10 is recording, the green LED will switch off and the red LED will start flashing. As soon as the measured values have become normal again, both LEDs will flash to signal that an alarm came up. This can be reset by reading out the memory. Measuring value Set point LED Green LED Red Readout of data memory Timing Diagram: HUMLOG 10 THC alarms Page 13 of 18

6 Changing the Sensor Module To change the Sensor Module please carefully remove the HUMLOG 10 back-plate with a screwdriver. The Sensor Module can now be detached from the display Module. Place the new Sensor Module on the display Module guide rail and push the two modules together until they engage. Illustration: Removing the Back-Plate Illustration: Assembly of the Modules Page 14 of 18

7 Changing the Battery When the indication BAT flashes in the upper line of the display, the battery must be changed. In order to do this, please first remove the Sensor Module (see Changing the Sensor Module). Please remove the four screws on the rear of the Display Module, using a suitable screwdriver. Lay the Display Module on a flat surface, with the display facing upwards, and carefully remove the upper part of the plastic cover. Now remove the old battery and fit the new battery (Type: LS14500/Saft, 3.6V; Order No: HA 03 01 02) into the holder. Important: Please observe the correct polarity of the battery and read the safety tips on the battery. The BAT indication now disappears and the measurement values are shown again on the display. The battery should be changed annually. Frequent data transfer with the PC and low sample rates reduces battery life. Illustration: Opening the HUMLOG 10 to change the battery Illustration: Changing the battery Page 15 of 18

8 Mounting the HUMLOG 10 The HUMLOG 10 can be used as a mobile and stationary data acquisition system. For stationary applications the HUMLOG 10 may only be mounted on a flat surface. In order to do this, please first remove the Sensor Module (see Changing the Sensor Module). Two holes for wall mounting are provided in the guide rail of the Display Module. Use these to mount the Display Module. Next carefully join the two modules together until they engage. Illustration: Mounting the HUMLOG 10 Page 16 of 18

9 Switching on the HUMLOG 10 Just to take care of the battery the HUMLOG 10 the HUMLOG 10 is switched off during the delivery period. Commissioning: install and open the enclosed evaluation software SmartGraph on your PC (insert Disk 1/2 and run: setup_humlog10.exe) Connect the data logger and the serial interface of your PC using the supplied transfer - cable Open the menu selection instrument and chose the command read configuration As soon as the first communication has been successfully the measuring values appear on the display and the HUMLOG is ready for operation. Remark: If difficulties should occur during the communication kindly check your interface settings. (further information see menu selection help within the SmartGraph software) Page 17 of 18

10 Tips and Tricks Please change the battery annually (Type: LS14500/Saft, 3.6V; Order No: HA 03 01 02). Frequent communication with the PC reduces battery life. Please use only the cable supplied for PC data transfer. Please avoid condensation on the sensor electronics and HUMLOG 10. For the entire information and further details regarding handling, configuration and evaluation of the data logger kindly have a look at the menu selection help at the enclosed SmartGraph Software. HEAD OFFICE: E+E ELEKTRONIK Ges.m.b.H. Langwiesen 7 A-4209 Engerwitzdorf Austria Tel: ++43/7235/605-0 Fax: ++43/7235/605-8 info@epluse.com www.epluse.com Page 18 of 18