SDR recloser. A PH Fault B PH Fault C PH Fault. Ground Fault. SGF Lockout Aux Power OK. Recloser OK

Similar documents
7SR21 Non-Directional 7SR22 Directional Overcurrent Relay

7SR11 and 7SR12 Settings and Instruments

7SR242 Duobias Multi-Function 2-Winding Transformer Protection Relay

Overcurrent and Arc Protection by Reyrolle Alexander Erokhin. 21, 2017 I Berlin

7SR11 and 7SR12 Description of Operation

(1) Description of Operation 7SR224 Recloser Controller

Reyrolle Protection Devices. 7SR10 Argus User Manual Overcurrent and Earth Fault Relay

7SR21 Non-Directional 7SR22 Directional Overcurrent Relay

7SR11 & 7SR12 Argus Overcurrent Relay Energy Management

Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage

7SR11 & 7SR12 Argus Overcurrent Relay Energy Management

Recloser Controller for feeder protection and automation siemens.com/distribution-automation

Reyrolle Protection Devices. 7SR210 & 7SR220 Argus Overcurrent Protection Relay. Answers for energy

7SG14 Duobias-M Transformer Protection

Reyrolle Protection Devices. 7SR11 and 7SR12 Argus Overcurrent Relays. Answers for energy

Reyrolle Protection Devices. 7SR11 and 7SR12 Argus Overcurrent Relays. Answers for energy

7SR21 & 7SR22 Argus Overcurrent Relay Energy Management

SIPROTEC 7SC80 Feeder Protection and Automation Answers for infrastructure and cities.

7SR17 Rho Motor Protection Relay Answers for energy.

7SR191 Capa Capacitor Protection Relay Energy Management

CURRENT PROTECTION RELAY SMPR-1

Reyrolle Catalogue Answers for Energy

7SR105 Rho User Manual Motor Protection Relay Energy Management

7SR11 and 7SR12 Argus Overcurrent Relays Answers for infrastructure & cities.

Function permission: yes/no. Operating range: 0.10 to 30 xin (step 0.01) Operating time: 0.02 to 300 s (step 0.01 s) Activation level 100%

7SR242 Duobias Transformer Protection Relay Answers for energy.

Siemens Vacuum Recloser 3AD. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

Reyrolle Protection Devices. 7SR10 Argus Overcurrent and Earth Fault Relay

MiCOM P124 T&D. Self and Dual Powered Overcurrent Relays

Using the Bitronics 70 Series to Improve Local Monitoring and Control

MiCOM P124. Self and Dual Powered Overcurrent Relays. Protection Relays

FP6000. Type ID Units Writable Possible Values. Count. TCP Register

Interface Definition RISH EM 2340/1320/30/ _Rev. D - 8/2016

REL52002 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, RS-485

SIA-B. Overcurrent & Earth Fault Protection Relay for Secondary Distribution. Dual & Self Powered / Standard CTs. Main characteristics

FP5000. Refer to for the latest information on this constantly evolving product

Reyrolle Protection Devices. 7SR242 Duobias Transformer Protection Relay. Energy Management. Unrestricted

GRD110 FEATURES APPLICATION

Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV Version 3.3

7SR11 and 7SR12 Argus Overcurrent Relays Energy Management

REL52001 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, 2 x RJ-45

Reyrolle Protection Devices. 7PG2113/4/5/6 Solkor Pilot Wire Current Differential Protection with integrated Overcurrent Guard. Answers for energy

SOLKOR-N (7SR18) Feeder Differential Protection. Make the ight choice! Choose EYROLLE Protection

Siprotec 7ST61 / 7ST63

NPW800R RETROFITTING. Power and Volatge Protection Relay

ENhanced TEChnology. Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV. Ver.

GE Entellisys Low Voltage Switchgear. System Test Kit. User Manual

IED (Intelligent Electronic Device)

FP-5000 Feeder Protection

ENhanced TEChnology. Solid insulated vacuum recloser for power distrbution system thru 15kV, 27kV, 38kV V 3.1

Reyrolle Protection Devices. 7SG13 Delta Protection and Control Relays. Answers for energy

VAMP 221. Table of Contents

DEH-433. Warnings, Cautions, and Notes as used in this publication

DNP Points List and Implementation

Feeder/ Motor Protection Relay VAMP 40

MiCOM P521. Fast Feeder Differential Protection

MPSC Microprocessor-based protection and metering devices for low voltage power circuit breakers. ABB Power Distribution

750/760 Feeder Management Relay Instruction Manual

MiCOM P12x/y AREVA T&D. Three phase and earth fault overcurrent relays

HGM9580 Bus Tie Bus Parallel Unit USER MANUAL. Smartgen Technology

MONITORING AND CONTROL REQUIREMENTS FOR DISTRIBUTED GENERATION FACILITIES

Numerical Protective and Management Relays

Automate and Preserve Electromechanical Relay Investment Part 3 of 3 Using the Bitronics 70 Series to Improve Remote Monitoring and Control

The TPU-2000R unit comes enclosed in a metal case. Follow the instructions and diagrams in this section to install the TPU-2000R.

GE Multilin 350 Feeder Protection Relay Specifications

7SR23 DAD High Impedance Protection Relay Answers for energy.

Protection relays.

U lity network. system Q sys. Interconnected P sys. P load Q load. P gen Q gen. Generator network

Reyrolle Protection Devices. 7SG117 Argus 7 Synchronising Relay. Answers for energy

Rev K 263. A front-panel B-type USB connector provides local communication with a PC operating BESTCOMSPlus software.

MiCOM P123R. Overcurrent Relays P123R/EN AD/A11. Upgrade Documentation

Protection Relays PHASE & RESIDUAL OVERCURRENT

SIPROTEC. Multifunction protection with control 7SJ61...7SJ64. Input/Output unit with local control 6MD63. Preface.

Advanced distribution feeder solution with integrated protection, monitoring, and control

7SR210 & 7SR220 Argus Overcurrent Protection Relay Energy Management

VISIONr TECHNICAL MANUAL Issue 3. VISIONr. Technical Manual

RELAYABLE POWER. AQ 200 series protection, control, measurement and monitoring IEDs

Bus Protection Application Challenges

MiCOM P521. Fast feeder differential protection

7SR158 Argus Voltage and Frequency Relay Energy Management.

POWER FACTOR REGULATOR

ABB Inc. Instructions REF 550 Advanced Feeder Protection System

Company Directive ENGINEERING SPECIFICATION EE SPEC: 136

Three phase and earth fault overcurrent relays

7SR18 Solkor Line Differential Protection Energy Management

www. ElectricalPartManuals. com MICROSHIELD O/Cä Multiphase Time-Overcurrent Relay Highlights

VIP 40/45 VIP 400/410

Power Xpert Meter 350 (PXM350) three-phased DIN-rail multifunction meter

MICROSHIELD O/Cä Multiphase Time-Overcurrent Relay

MiCOM P12x/y. Three phase and earth fault overcurrent relays

INSTALLATION & COMMISIONING GUIDE

FM2. Economical and compact feeder protection for low voltage feeders. Digital Energy Multilin. Monitoring & Metering. Protection and Control

HAT600 Series HAT600/HAT600I/HAT600B/HAT600BI ATS CONTROLLER USER MANUAL

SIPROTEC. Distance protection 7SA522, 7SA6. Preface. Table of contents. Data of the PROFIBUS-DP messages 1. Standard mapping 3-1 2

Bus Bar Protection Relay B-PRO 4000

Power Test Equipment

Metering Devices, Protective Relays, Software and Connectivity. Pre-Wired Control Power, Voltage and CT Inputs

DNP Points List and Implementation

1. Project Description

7SR210 & 7SR220 Argus Overcurrent Protection Relay Energy Management.

Transcription:

SDR recloser A PH Fault B PH Fault C PH Fault Ground Fault SGF Lockout Aux Power OK Recloser OK Open Close Reclose ON Hot Line Tag ON All Protn OFF Inst Protn OFF Ground Fault Protn OFF SGF Protn OFF Trip & Reclose www.usa.siemens.com/reclosers Training aid 7SR224 three-phase control relay Type SDR 15.5 kv to 38 kv three-phase distribution recloser Answers for infrastructure.

Table of contents Type 7SR224 protection and control relay front panel 03 Type 7SR224 protection and control relay operation exercises 04 06 Type 7SR224 protection and control relay navigation tree 06 07 Control mode tree 08 11 Settings mode tree 12 18 Settings change examples 19 25 Instrument mode tree 26 28 Viewing meter examples 29 31 Fault data mode tree 32 Viewing fault data example 33 Troubleshooting and notes 34 35 2

1 2 SDR recloser 7 8 9 10 11 12 A PH Fault B PH Fault C PH Fault Ground Fault SGF Lockout F1/L9 F2/L10 F3/L11 Open Close Reclose ON F7/L15 F8/L16 F9/L17 All Protn OFF Inst Protn OFF 13 14 Aux Power OK Recloser OK F4/L12 Hot Line Tag ON F10/L19 6 F5/L13 F6/L14 Ground Fault Protn OFF SGF Protn OFF F11/L20 F12/L21 Trip & Reclose 1. MLFB number (model) 2. Ratings label 3. In = CT secondary current (In = 1A for type SDR recloser) frequency = 50/60 Hz (60 Hz for type SDR recloser) 4. Vn = voltage supplied to relay from voltage sensors (63.5 for type SDR recloser) 5. Vx = power supply voltage range (48 Vdc for type SDR recloser) and BI = voltage to activate a binary input (19 Vdc for type SDR recloser) 6. Programming port Item Button and/or LED If associated LED is lit 7 A PH fault Phase A target 8 B PH fault Phase B target 9 C PH fault Phase C target 10 Ground fault Ground fault target 11 SEF Sensitive earth fault (SEF) target 12 Lockout Recloser is locked out 13 Aux power OK AC input power to control cubicle OK 14 Recloser OK Capacitors charged and system ready to close or open 3 4 5 2 Item Button and/or LED If associated LED is lit F1/L9 Push-to-open recloser Recloser is OPEN F2/L10 Push-to-close recloser Recloser is CLOSED F3/L11 Push-to-toggle reclose functionality On/Off Reclose functionality is ON F4/L12 Push-to-toggle hot line tag On/Off Hot line tag is ON F5/L13 F6/L14 Push-to-toggle ground fault protection On/Off Push-to-toggle sensitive earth fault protection On/Off Ground fault protection is OFF SEF protection is OFF F7/L15 Push-to-toggle all protection On/Off All protection is OFF F8/L16 Push-to-toggle instantaneous protection On/Off Instantaneous protection is OFF F9/L17 User defined User defined F10/L18 User defined User defined F11/L19 User defined User defined F12/L20 Push-to-trip and reclose recloser ---- Note: If buttons are labeled differently than shown above, factory settings have been reprogrammed. 3

Type 7SR224 protection and control relay operation exercises Example 1: open recloser LCD screen Recloser will open Green LED at F1 will illuminate. Open Open SDR pressed Example 2: close recloser LCD screen Recloser will close Red LED at F2 will illuminate. Close Close SDR pressed Example 3: toggle reclosing operation on and off LCD screen Recloser will not open or close Reclose ON Reclose On/Off pressed LED: Green LED at F3 will toggle on and off. On = reclosing enabled Off = reclosing disabled. 4

Example 4: toggle hot line tag on and off LCD screen Recloser will not open or close Hot Line Tag ON Hot Line Tag On/Off pressed LED: Red LED at F4 will toggle on and off. On = hot line tag enabled Off = hot line tag disabled. Example 5: toggle ground fault protection on and off LCD screen Recloser will not open or close Ground Fault Protn OFF GF Protn ON/OFF pressed LED: Red LED at F5 will toggle on and off. On = ground fault protection disabled Off = ground fault protection enabled. Example 6: toggle SEF protection on and off LCD screen Recloser will not open or close SGF Protn OFF SGF Protn ON/OFF pressed LED: Red LED at F6 will toggle on and off. On = SEF protection disabled Off = SEF protection enabled. Example 7: toggle all protection on and off LCD screen Recloser will not open or close All Protn OFF All Protn On/Off pressed LED: Red LED at F7 will toggle on and off. On = all protection disabled Off = all protection enabled. 5

Example 8: toggle instantaneous (fast) protection on and off LCD screen Recloser will not open or close Inst Protn OFF INST Protn ON/OFF pressed LED: Red LED at F8 will toggle on and off. On = INST (fast) protection disabled Off = INST (fast) protection enabled. Type 7SR224 protection and control relay navigation tree The following pages will present the navigation tree of the relay settings tree using the navigation buttons. For all arrows pointing, press For all arrows pointing, press To scroll up, press To go back one level, press To select, press For detailed settings mode tree, please refer to page 12. 6

Recloser Name ENTER to control CONTROL MODE SETTINGS MODE INSTRUMENT MODE FAULT DATA CB: OPEN/CLOSED/TRAVELING SYSTEM CONFIG FAVORITE METERS FAULT 1 AR: Out of Service CT/VT CONFIG CURRENT METERS FAULT 2 AR: Trip & Reclose FUNCTION CONFIG VOLTAGE METERS FAULT 3 AR: Trip & Lockout CURRENT PROT'N FREQUENCY METERS FAULT 4 Hotline Working IN/OUT VOLTAGE PROT'N POWER METERS FAULT 5 G/F Protection IN/OUT SUPERVISION ENERGY METERS FAULT 6 SGF Protection IN/OUT CONTROL & LOGIC DIRECTIONAL METERS FAULT 7 Inst Protection IN/OUT INPUT CONFIG THERMAL METERS FAULT 8 Loss of Volts IN/OUT 1 OUTPUT CONFIG AUTORECLOSE METERS FAULT 9 Battery Test MAINTENANCE LOSS OF VOLTS METERS FAULT 10 Set Local DATA STORAGE MAINTENANCE METERS Set L or R COMMUNICATIONS GENERAL ALARM METERS Set Remote BATTERY CONDITION Set Service CAPACITOR CONDITION POWER QUALITY METERS Footnote: 1 This function only available with LOV relay option. DEMAND METERS BINARY INPUT METERS BINARY OUTPUT METERS VIRTUAL METERS COMMUNICATION METERS MISCELLANEOUS METERS QUICK LOGIC METERS 7

Control mode tree Recloser Name enter to control If the LCD screen does not read ENTER to CONTROL, press This will not cause the recloser to operate. until it does. CONTROL MODE This is the first of four modes in the relay tree, which bring you to multiple screens that will allow you to control the recloser. CB: OPEN To open/close the recloser, the LCD screen will read "CB: OPEN," "CB: CLOSED" or "CB: TRAVELING" indicating the recloser position. Traveling indicates lack of proper position indication. Refer to Troubleshooting table on page 34. Select "Open" or "Close" Recloser will open/close. CB: OPEN Close Open to select CB: OPEN Confirm Open AR: Out of Service To toggle auto-reclose on/off, the LCD screen will read "AR: In Service," or "AR: Out of Service" indicating auto-reclose functionality being in or out of service. Select "In" or "Out" AR: In Service In Out to select AR: In Service Confirm Out Auto-reclose functionality will toggle between in and out of service. Control mode tree continues on page 9. 8

AR: Trip & Reclose To trip and close the recloser. This screen will allow the user to trip the recloser, then the recloser will automatically reclose. AR: Trip & Reclose Confirm Action Recloser will trip, then reclose. AR: Trip & Lockout To trip and lockout the recloser. This screen will allow the user to trip and lockout the recloser. AR: Trip & Lockout Confirm Action Recloser will trip and lockout. Hotline Working: IN To toggle hot line tag On/ Off. This screen will read "Hotline Working: IN" or "Hotline Working: OUT" indicating hot line tag being in/out of service. Select "In" or "Out" Hotline Working: IN In Out to select Hotline Working Confirm Out Hot line tag functionality will toggle between in and out of service. G F Protection: IN To toggle ground fault prot'n On/Off, the LCD screen will read "G/F Protection: IN," or "GF: Protection: OUT" indicating ground fault protection is in/out of service. Select "In" or "Out" G/F Protection: IN In Out to select G/F Protection: IN Confirm OUT Ground fault protection will toggle between in and out of service. SGF Protection: In To toggle sensitive ground fault protection On/Off, the LCD screen will read "SGF Protection: IN," or "SGF Protection: OUT," indicating sensitive ground fault protection is in/out of service. Select "In" or "Out" SGF Protection: IN In Out to select SGF Protection: IN Confirm Out Sensitive ground fault protection will toggle between in and out of service. Control mode tree continues on page 10. 9

Inst Protection: IN To toggle Inst (fast) Protection On/Off, the LCD screen will read "Inst Protection: IN," or "Inst Protection: OUT" indicating Inst (fast) protection is in or out of service. Select "In" or "Out" Inst Protection: IN In Out to select Inst Protection: IN Confirm Out Inst (fast) Protection will toggle between in and out of service. Loss of Volts: IN To toggle between Loss of Volts On/Off, the LCD screen will read "Loss of Volts: In," or "Loss of Volts: Out" indicating loss of voltage detection is in or out of service. Note: This function is only available with LOV relay option. Select "In" or "Out" Loss of Volts: IN IN OUT to select Loss of Volts: IN Confirm Out Loss of volts will toggle between in and out of service. Battery Test To manually initiate a battery test. This LCD screen will allow the user to manually initiate a battery test. Battery Test Confirm Start Battery Test Active ENTER to control Control will proceed through a battery test. (A capacitor test will immediately follow upon completion of the battery test.) Set Local To set operational mode to local, the LCD screen will read "Set Local: mode" (where mode is local, L or R, remote or out of service.) Set Local: mode Confirm Local Mode Relay will be in local mode. Set L or R To set operational mode to L or R, the LCD screen will read "Set L or R: mode" (where mode is local, L or R, remote or out of service.) Set L or R: mode Confirm L or R Mode Relay will be in L or R mode. Control mode tree continues on page 11. 10

Set Remote To set operational mode to Remote, the LCD screen will read "Set Remote: mode" (where mode is local, L or R, remote or out of service.) Set Remote: mode Confirm Remote Mode Recloser will be in remote mode. Set Service To set operational mode to Out of Service, the LCD screen will read "Set Service: mode" (where mode is local, L or R, remote or out of service.) Set Service: mode Confirm Service Mode Relay will be in out-of-service mode. Note: The Out of Service mode will inhibit all local and remote control of relay. To regain local control, refer to Changing the Operating Mode from the settings tree on page 23. 11

Settings mode tree Recloser Name enter to control CONTROL MODE SETTINGS MODE This is the second of four modes in the relay tree, which bring you to multiple screens that will allow you to control the recloser. SYSTEM CONFIG This menu contains system settings, including language, frequency, date, passwords, etc. CT/VT CONFIG This menu allows the user to change current transformers and voltage transformers settings. FUNCTION CONFIG This menu allows the user to enable or disable functions and features available in the relay. CURRENT PROT'N This menu allows the user to change current protection settings. For examples of how to changes these settings, please refer to page 22. VOLTAGE PROT'N This menu allows the user to change voltage protection settings. Settings mode tree continues on page 13. 12

SUPERVISION This menu allows the user to change supervision settings, including battery and capacitor tests, CT and VT supervision, broken conductor, etc.. CONTROL & LOGIC This menu allows the user to change control and logic settings. INPUT CONFIG This menu allows the user to change binary input settings. OUTPUT CONFIG This menu allows the user to change binary output settings. MAINTENANCE This menu allows the user to change recloser maintenance settings, including counters and circuit breaker wear monitors. DATA STORAGE COMMUNICATIONS This menu allows the user to change data storage settings, including waveform triggers, waveform record duration, manual waveform trigger, fault record time and data log infomation. This menu allows the user to change communication settings, including protocol baud rate, parity, etc. For an example of how to changes these settings, please refer to page 24. 13

Settings mode detailed tree structure SETTINGS MODE SYSTEM CONFIG Language Setting Phase VT Ratio Prim Active Group Phase VT Ratio Sec System Frequency Vx Nom Voltage View/Edit Group Vx Voltage Trim Magnitude Setting Dependencies Vx Voltage Trim Angle Favorite Meters Timer Vx VT Ratio Prim Backlight Timer Vx VT Ratio Sec Date Phase Current Input Time Phase CT Ratio Curr Set Display Ground Current Input G/F Curr Set Display Ground CT Ratio Export Power/Lag Var I1, I2, I3 Connections Select Grp Mode V1, V2, V3 Connections Clock Sync from BI Phase Rotation Operating Mode Function Config Phase Overcurrent Setting Password Voltage Cont O/C Control Password Cold Load Trip Alert Measured G/F General Alarm Alert Sensitive G/F Relay Identifier Restricted G/F Circuit Identifier NPS Overcurrent CT/VT CONFIG Phase Nom Voltage Under Current Phase Voltage Trim Magnitude Thermal Phase Voltage Trim Angle Phase U/O Voltage Phase Voltage Config Vx U/O Voltage Settings mode detailed tree continues on page 15. 14

NPS Overvoltage Neutral Overvoltage U/O Frequency CB Fail VT Supervision CT Supervision Broken Conductor Trip Cct Supervision Inrush Detector CB Counters I^2t CB Wear Battery Test Capacitor Test LOV Automation 1 27Sag & 59Swell Footnote: 1 This function only available with LOV relay option. CURRENT PROT'N PHASE OVERCURRENT 67 51-1 thru 51-4 50-1 thru 50-4 VOLTAGE CONT O/C 51V COLD LOAD 51 C-1 MEASURED G/F 67-G 51G-1 thru 51G-4 50G-1 thru 50G-4 SENSITIVE G/F 67SGF 51SGF-1 thru 51SGF-4 RESTRICTED G/F 64-H Settings mode detailed tree continues on page 16. 15

NPS OVERCURRENT 46IT 46DT UNDERCURRENT 37-1 thru 37-2 THERMAL 49 VOLTAGE PROT'N PHASE U/O VOLTAGE Voltage Input Mode 27/59-1 thru 27/59-4 VX U/O VOLTAGE 27/59 NPS OVERVOLTAGE 47-1 & 47-2 NEUTRAL OVERVOLTAGE 59N 59NIT 59NDT U/O FREQUENCY 81-1 thru 81-4 SUPERVISION CB FAIL 50BF-1 & 50BF-2 VT SUPERVISION 60VTS CT SUPERVISION 60CTS BROKEN CONDUCTOR 46BC TRIP CCT SUPERVISION 74TCS-1 thru 74TCS-4 INRUSH DETECTOR 81HBL2 BATTERY TEST Battery Test Enable Battery Nominal Voltage Battery Test Rate Battery Test Time Battery Test Load Battery Load Drop CAPACITOR TEST Cap Element Cap Holdup Time Settings mode detailed tree continues on page 17. 16

POWER QUALITY Voltage Input Mode 27SAG 59Swell CONTROL & LOGIC AUTORECLOSE PROT'N 79 AUTORECLOSE CONFIG 79 MANUAL CLOSE Line Check Trip CIRCUIT BREAKER Close CB Delay Close CB Pulse Reclaim Timer Blocked Close Delay Open CB Delay Open CB Pulse CB Controls Latched QUICK LOGIC Quick Logic Enable E1 thru E16 INPUT CONFIG INPUT MATRIX FUNCTION KEY MATRIX BINARY INPUT CONFIG FUNCTION KEY CONFIG GENERAL ALARMS OUTPUT CONFIG OUTPUT MATRIX BINARY OUTPUT CONFIG LED CONFIG PICKUP CONFIG MAINTENANCE CB COUNTERS CB Counters Enable I^2T CB WEAR I^2T Counter Enable Settings mode detailed tree continues on page 18. 17

DATA STORAGE DEMAND/DATA LOG WAVEFORM STORAGE FAULT STORAGE EVENT STORAGE ENERGY STORAGE COMMUNICATIONS Station Address COM1-RS485 Protocol COM1-RS485 Baud Rate COM1-RS485 Parity COM1-RS485 Mode COM2-USB Protocol COM2-USB Mode DNP3 Unsolicited Events DNP3 Destination Address DNP3 Application Timeout 18

Settings change examples Example 1: changing the active settings group Recloser Name enter to control If the LCD screen does not read ENTER to CONTROL, press This will not cause the recloser to operate. until it does. CONTROL MODE Active Group 1 SETTINGS MODE Active Group 1 Blinking SYSTEM CONFIG to view up or down buttons to change active setting group to desired setting group. ENTER button to accept changes. Language Setting English Active G2 Active Group 2 Notice the screen has updated from G1 to G2 indicating the new active setting group. When finished making changes, press CANCEL button three times to return to initial ENTER to CONTROL screen. Done 19

Example 2: changing the settings group that you are viewing/editing Recloser Name enter to control If the LCD screen does not read ENTER to CONTROL, press This will not cause the recloser to operate. until it does. up or down buttons to change active setting group to desired setting group. CONTROL MODE ENTER button to accept changes. SETTINGS MODE View/Edit Group 2 Notice the screen has updated from G1 to G2 indicating the new active setting group. SYSTEM CONFIG to view Done When finished making changes, press CANCEL button three times to return to initial ENTER to CONTROL screen. Language Setting English until the following appears View/Edit Group 1 View/Edit Group 1 Blinking 20

Example 3: changing a password Recloser Name enter to control If the LCD screen does not read ENTER to CONTROL, press This will not cause the recloser to operate. until it does. up or down buttons to enter a four-digit alphanumeric password. CONTROL MODE TEST/RESET button to move on digit to the right. SETTINGS MODE ENTER button to accept changes. SYSTEM CONFIG To view Confirm Password _ Repeat previous step. Setting Password Code = 1682678776 The relay will present a code. Retain this code in case of a lost password. Refer to the instruction manual for the Siemens type 7SR224 recloser control relay (standard control and protection relay option) http://www.usa. siemens.com/reclosers until the following appears Language Setting English once more to change the control password. Settings Password Not Active You will now be prompted to enter the password once before you can make a setting change. Follow the same process to change the password at the control level. When finished making changes, press CANCEL button three times to return to initial ENTER to CONTROL screen. Note: To deactivate the password feature, change the password to "NONE." New Password _ Blinking Done 21

Example 4: changing the pickup level of phase overcurrent element 51-1 Recloser Name enter to control If the LCD screen does not read ENTER to CONTROL, press This will not cause the recloser to operate. until it does. View G1 51-1 Setting _x In Blinking Note: " View G1" means that the active group settings group is group 1. If this is not the group you wish to edit, follow the instructions in Example 2 on page 19 to change the settings group. CONTROL MODE up or down buttons to change desired pickup level to desired current level. until the following appears SETTINGS MODE CURRENT PROTN to view View G1 51-1 Setting _x In Done ENTER button to accept changes. When finished making changes, press CANCEL button four times to return to initial ENTER to CONTROL screen. CURRENT PROTN PHASE OVERCURRENT to view Note: "_xin" refers to the value times the nominal current that equals the trip setting. In = 800 A for type SDR reclosers. View G1 67 Char Angle 45 deg until the following appears View G1 51-1 Setting _x In 22

Example 5: changing the operating mode from the settings tree Recloser Name enter to control If the LCD screen does not read ENTER to CONTROL, press This will not cause the recloser to operate. until it does. up or down buttons to change operating mode to desired mode. CONTROL MODE ENTER button to accept changes. SETTINGS MODE SYSTEM CONFIG to view Operating Mode Local or Remote Done Notice the screen has updated from Out Of Service to Local or Remote, Remote or Local mode. When finished making changes, press CANCEL button three times to return to initial ENTER to CONTROL screen. Language Setting English until the following appears Operating Mode Out Of Service Operating Mode Out Of Service Blinking 23

Example 6: changing the baud rate on COM1 Recloser Name enter to control If the LCD screen does not read ENTER to CONTROL, press This will not cause the recloser to operate. until it does. up or down buttons to change baud rate as desired. CONTROL MODE ENTER button to accept changes. until the following appears SETTINGS MODE COMMUNICATIONS to view View G1 51-1 Setting 800.00A Done When finished making changes, press CANCEL button four times to return to initial ENTER to CONTROL screen. Station Address 0 until the following appears COM1-RS485 Baud Rate 19200 COM1-RS485 Baud Rate 19200 Blinking 24

Example 7: manually initiating the battery test Recloser Name enter to control If the LCD screen does not read ENTER to CONTROL, press This will not cause the recloser to operate. until it does. until the following appears CONTROL MODE Battery Test Battery Test Confirm Start Battery Test Active Note: Result will be displayed at end of test. Done 25

Instrument mode tree Recloser Name enter to control CONTROL MODE SETTINGS MODE INSTRUMENT MODE This menu will allow the user to view the favorite meters. FAVORITE METERS This menu will allow the user to view the current meters. CURRENT METERS This menu will allow the user to view the voltage meters. VOLTAGE METERS This menu will allow the user to view the frequency meters. FREQUENCY METERS This menu will allow the user to view the power meters. POWER METERS This menu will allow the user to view the energy meters - active energy, reactive energy. ENERGY METERS Instrument mode tree continues on page 27. 26

This menu will allow the user to view the directional meters if directional current elements are used. DIRECTIONAL METERS This menu will allow the user to view the thermal meters. THERMAL METERS This menu will allow the user to view the auto-reclose meters. AUTORECLOSE METERS This menu will allow the user to view the loss-of-volts meters if loss-of-volts function is used. This is only available with the LOV relay option. LOSS OF VOLTS METERS This menu will allow the user to view the maintenance meters - counters. MAINTENANCE METERS This menu will allow the user to view the general alarm meters, which indicates which alarms are present. GENERAL ALARM METERS This menu will allow the user to view the battery condition meters. BATTERY CONDITION This menu will allow the user to view the capacitor condition meters. CAPACITOR CONDITION This menu will allow the user to view the power quality meters: SIARFI, SMARFI, Interrupts, etc. POWER QUALITY METERS This menu will allow the user to view the demand meters. DEMAND METERS Instrument mode tree continues on page 28. 27

This menu will allow the user to view the binary input meters - _ indicates status is low, 1 indicates status is high. BINARY INPUT METERS This menu will allow the user to view the binary output meters - _ indicates status is low, 1 indicates status is high. BINARY OUTPUT METERS This menu will allow the user to view the virtual meters - _ indicates status is low, 1 indicates status is high. VIRTUAL METERS This menu will allow the user to view the communications meters. COMMUNICATION METERS This menu will allow the user to view the miscellaneous meters: date, time, waveform records, fault records, event records and data log records. MISCELLANEOUS METERS This menu will allow the user to view the quick logic meters - _ indicates status is low, 1 indicates status is high. QUICK LOGIC METERS 28

Viewing meter examples Example 1: viewing the current meters and adding them to favorite meters Recloser Name enter to control If the LCD screen does not read ENTER to CONTROL, press This will not cause the recloser to operate. until it does. CONTROL MODE until the following appears INSTRUMENTS MODE until the following appears Current Meters to view the down button to view other current meters: Secondary current Nominal current (for reclosers, In = 1A) Primary ground current Secondary ground current Nomimal ground current (for reclosers, In = 1A) I-sequence components Second harmonic current Last trip phase fault Last trip earth fault. ENTER to make the meter a favorite meter. Confirm Add to Favorites YES Blinking 1a 1b 1c Primary Current Displays primary current levels. 0.00kA 0.00kA 0.00kA Done Any meter or meters in the instrument mode may be added to favorite meters. The favorite meters may be displayed on the LCD screen, in rotating order, after no buttons have been pressed for a selectable period of time. To turn on and set the timer, select Setting Mode System Config Favorite Meters Timer. 29

Example 2: viewing the voltage meters and adding them to favorite meters Recloser Name enter to control If the LCD screen does not read ENTER to CONTROL, press This will not cause the recloser to operate. until it does. ENTER to make the meter a favorite meter. until the following appears CONTROL MODE INSTRUMENTS MODE until the following appears Voltage Meters to view Confirm Add to Favorites Done YES Blinking Any meter or meters in the instrument mode may be added to favorite meters. The favorite meters may be displayed on the LCD screen, in rotating order, after no buttons have been pressed for a selectable period of time. To turn on and set the timer, select Setting Mode System Config Favorite Meters Timer. Vab Vbc Vca Primary Ph-Ph Voltage 0.00kV 0.00kV 0.00kV Displays primary phaseto-phase voltage levels the down button to view other voltage meters: Secondary phase-phase voltage Nominal phase-phase voltage (for reclosers, Vn = 63.5 V) Primary phase-neutral voltage Secondary phase-neutral voltage Nomimal phase-neutral voltage (for reclosers, Vn = 63.5 V) V-sequence components Calculated ground voltage CS/NVD voltage (VX) Last trip voltage. 30

Example 3: viewing the demand meters and adding them to favorite meters Recloser Name enter to control If the LCD screen does not read ENTER to CONTROL, press This will not cause the recloser to operate. until it does. ENTER to make the meter a favorite meter. until the following appears until the following appears CONTROL MODE INSTRUMENTS MODE Demand Meters to view Confirm Add to Favorites Done YES Blinking Any meter or meters in the instrument mode may be added to favorite meters. The favorite meters may be displayed on the LCD screen, in rotating order, after no buttons have been pressed for a selectable period of time. To turn on and set the timer, select Setting Mode System Config Favorite Meters Timer. V Phase A Demand Max 0.00kV Min 0.00kV Mean 0.00kV Displays phase A voltage demand the down button to view other demand meters: Phase demand voltage (A, B and C) Phase-phase demand voltage (AB, BC and CA) Phase demand current (A, B and C) Ground demand current Power (P three-phase demand MW) Power (Q three-phase demand MVAR) Power (S three-phase demand MVA) Frequency demand. 31

Fault data mode tree Recloser Name enter to control CONTROL MODE SETTINGS MODE INSTRUMENT MODE FAULT DATA To view the fault data for the fault selected, press to view the fault data Fault 1 and then for more data.. Fault 2 Fault 7 Fault 3 Fault 8 Fault 4 Fault 9 Fault 5 Fault 10 Fault 6 32

Viewing fault data example Example 1: fault data record 1 Recloser Name enter to control If the LCD screen does not read ENTER to CONTROL, press This will not cause the recloser to operate. until it does. Fault 1 Page 4/6 Ic=0.304kA In=0.060kA until the following appears CONTROL MODE FAULT DATA MODE Fault 1 Page 2/6 G1 51G 46BC 50BF-1 50-1 51-2 Displays elements that picked up during Fault 1. Displays Ic and In levels during Fault 1. Fault 1 03/04/09 to view Fault 1 Page 1/6 03/04/09 14:57:28:00.300 Displays date and time of Fault 1. Fault 1 Page 3/6 Ia=0.304kA Ib=0.000kA Displays Ia and Ib levels during Fault 1. Fault 1 Page 5/6 Ig=0.060kA Va=0.000kV Done Displays Ig and Va levels during Fault 1. Fault 1 Page 6/6 Vb=0.000kV Vc=0.000kV Displays Vb and Vc levels during Fault 1. 33

Troubleshooting Malfunction 'AUX Power OK' LED not illuminated 'Recloser OK' LED not illuminated Position indication shown as 'Travelling' Relay shows 'Out Of Service' and control mode and all buttons are not functional Unit will not power up after a quick power cycle A port error message is displayed Relay does not appear to be responding as programmed Rear panel communications not functioning Favorite meters do not display and scroll Remedy 1. Check miniature circuit breaker CB1 and switch on if necessary. 2. Check the status of the auxiliary power supply. Check the discharge switch on PCB2 circuit board and verify it is in the operating position. Travelling' indicated that no position indication signals are received from the recloser or that both open and closed signals exist simultaneously. 1. Check the recloser position. 2. Check the control cable. Refer to example 5 on page 23 for instructions on returning the unit to desired operating mode. Relay requires 10 seconds power down before rebooting. Remove power for this time interval and then restart. This error occurs when the relay chassis communications ports do not match the relay configuration. Replace the relay chassis with the proper model. Verify that the 'Active' setting group matches the desired group number. Refer to examples 1 on page 19 and 2 on page 20. Check the baud rate and parity settings for the selected communications port. Refer to example 6 on page 24. Add desired meters to favorite meters and set favorite meters timer. Refer to Viewing Meter Examples beginning on page 29. 34

Notes 35

The information provided in this document contains merely general descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners. Siemens Industry, Inc. 7000 Siemens Road Wendell, NC 27591 For more information, contact: +1 (800) 347-6659 www.usa.siemens.com/reclosers Subject to change without prior notice. Order No.: E50001-F710-A410-X-4A00 All rights reserved. Printed in USA 2012 Siemens Industry, Inc.