Key words: Cone-beam CT CBCT, cardiac imaging, 4-D reconstruction, image quality

Similar documents
Improvement of Efficiency and Flexibility in Multi-slice Helical CT

An approximate cone beam reconstruction algorithm for gantry-tilted CT

Flying Focal Spot (FFS) in Cone-Beam CT Marc Kachelrieß, Member, IEEE, Michael Knaup, Christian Penßel, and Willi A. Kalender

Advanced single slice rebinning in cone beam spiral CT: Theoretical considerations and medical applications

DUE to beam polychromacity in CT and the energy dependence

Advanced single-slice rebinning for tilted spiral cone-beam CT

Feldkamp-type image reconstruction from equiangular data

Artifact analysis of approximate helical cone-beam CT reconstruction algorithms

The Near Future in Cardiac CT Image Reconstruction

Empirical cupping correction: A first-order raw data precorrection for cone-beam computed tomography

ECG-correlated image reconstruction from subsecond multi-slice spiral CT scans of the heart

Spiral ASSR Std p = 1.0. Spiral EPBP Std. 256 slices (0/300) Kachelrieß et al., Med. Phys. 31(6): , 2004

Discrete Estimation of Data Completeness for 3D Scan Trajectories with Detector Offset

ECG-Correlated Imaging of the Heart with Subsecond Multislice Spiral CT

Multi-slice CT Image Reconstruction Jiang Hsieh, Ph.D.

Image Acquisition Systems

The n-pi-method for Helical Cone-Beam CT

Projection and Reconstruction-Based Noise Filtering Methods in Cone Beam CT

A Backprojection-Filtration Algorithm for Nonstandard. Spiral Cone-beam CT with an N-PI Window

TESTING OF THE CIRCLE AND LINE ALGORITHM IN THE SETTING OF MICRO-CT

Comparison of Probing Error in Dimensional Measurement by Means of 3D Computed Tomography with Circular and Helical Sampling

Scaling Calibration in the ATRACT Algorithm

DEVELOPMENT OF CONE BEAM TOMOGRAPHIC RECONSTRUCTION SOFTWARE MODULE

Computed Tomography. Principles, Design, Artifacts, and Recent Advances. Jiang Hsieh THIRD EDITION. SPIE PRESS Bellingham, Washington USA

Non-Stationary CT Image Noise Spectrum Analysis

An Acquisition Geometry-Independent Calibration Tool for Industrial Computed Tomography

A study on the section sensitivity profile in multi-row-detector spiral CT

FDK Half-Scan with a Heuristic Weighting Scheme on a Flat Panel Detector-Based Cone Beam CT (FDKHSCW)

Motion Compensation from Short-Scan Data in Cardiac CT

Kymogram detection and kymogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart

Spiral CT. Protocol Optimization & Quality Assurance. Ge Wang, Ph.D. Department of Radiology University of Iowa Iowa City, Iowa 52242, USA

Spiral-CT. Benjamin Keck. 21. March 2006

RECENTLY, biomedical imaging applications of

Convolution-Based Truncation Correction for C-Arm CT using Scattered Radiation

Suitability of a new alignment correction method for industrial CT

MEDICAL EQUIPMENT: COMPUTED TOMOGRAPHY. Prof. Yasser Mostafa Kadah

Cardiac Dual Energy CT: Technique

Background. Outline. Radiographic Tomosynthesis: Image Quality and Artifacts Reduction 1 / GE /

Computer-Tomography II: Image reconstruction and applications

CIRCULAR scanning trajectory has been widely used in

Translational Computed Tomography: A New Data Acquisition Scheme

Improvements of FDK-type Helical Cone-beam CT Imaging

Image Reconstruction 3 Fully 3D Reconstruction

Iterative and analytical reconstruction algorithms for varying-focal-length cone-beam

An Iterative Approach to the Beam Hardening Correction in Cone Beam CT (Proceedings)

A sufficient condition for spiral cone beam long object imaging via backprojection

A closer look at CT scanning

DUAL energy CT (DECT) is a modality where one and. Empirical Dual Energy Calibration (EDEC) for Cone-Beam Computed Tomography

Moving Metal Artifact Reduction for Cone-Beam CT (CBCT) Scans of the Thorax Region

MOTION of a patient induces artifacts such as streaks

USING cone-beam geometry with pinhole collimation,

Central Slice Theorem

An Automated Image-based Method for Multi-Leaf Collimator Positioning Verification in Intensity Modulated Radiation Therapy

Accelerated C-arm Reconstruction by Out-of-Projection Prediction

Grangeat-type helical half-scan computerized tomography algorithm for reconstruction of a short object

Helical 4D CT pitch management for the Brilliance CT Big Bore in clinical practice

Respiratory Motion Estimation using a 3D Diaphragm Model

Scatter Correction Methods in Dimensional CT

Adaptive algebraic reconstruction technique

GPU-based cone-beam CT reconstruction with extended FOV

CT NOISE POWER SPECTRUM FOR FILTERED BACKPROJECTION AND ITERATIVE RECONSTRUCTION

J. Ling Chinese Academy of Science Institute for Ceramics Shanghai, China

2D Fan Beam Reconstruction 3D Cone Beam Reconstruction

Advanced Image Reconstruction Methods for Photoacoustic Tomography

A Novel Two-step Method for CT Reconstruction

Optimization of CT Simulation Imaging. Ingrid Reiser Dept. of Radiology The University of Chicago

Joint ICTP-TWAS Workshop on Portable X-ray Analytical Instruments for Cultural Heritage. 29 April - 3 May, 2013

Introduction to Medical Imaging. Cone-Beam CT. Klaus Mueller. Computer Science Department Stony Brook University

Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon

Cone-beam reconstruction by backprojection and filtering

Spectral analysis of non-stationary CT noise

AN ELLIPTICAL ORBIT BACKPROJECTION FILTERING ALGORITHM FOR SPECT

Shadow casting. What is the problem? Cone Beam Computed Tomography THE OBJECTIVES OF DIAGNOSTIC IMAGING IDEAL DIAGNOSTIC IMAGING STUDY LIMITATIONS

Brilliance CT Big Bore.

THE FAN-BEAM scan for rapid data acquisition has

Automatic Intrinsic Cardiac and Respiratory Gating from Cone-Beam CT Scans of the Thorax Region

2D Fan Beam Reconstruction 3D Cone Beam Reconstruction. Mario Koerner

Scatter Correction for Dual source Cone beam CT Using the Pre patient Grid. Yingxuan Chen. Graduate Program in Medical Physics Duke University

HIGH-SPEED THEE-DIMENSIONAL TOMOGRAPHIC IMAGING OF FRAGMENTS AND PRECISE STATISTICS FROM AN AUTOMATED ANALYSIS

Respiratory Motion Compensation for Simultaneous PET/MR Based on Strongly Undersampled Radial MR Data

Diagnostic quality of time-averaged ECG-gated CT data

Corso di laurea in Fisica A.A Fisica Medica 4 TC

Towards full-body X-ray images

Iterative CT Reconstruction Using Curvelet-Based Regularization

17th World Conference on Nondestructive Testing, Oct 2008, Shanghai, China

A prototype table-top inverse-geometry volumetric CT system

Digital Laminography and Computed Tomography with 600 kv for Aerospace Applications

Estimating 3D Respiratory Motion from Orbiting Views

CT vs. VolumeScope: image quality and dose comparison

Simulation of Mammograms & Tomosynthesis imaging with Cone Beam Breast CT images

Application of Tatian s Method to Slanted-Edge MTF Measurement

Artefakt-resistente Bewegungsschätzung für die bewegungskompensierte CT

International Symposium on Digital Industrial Radiology and Computed Tomography - Mo.2.2

Respiratory Motion Compensation for C-arm CT Liver Imaging

3/27/2012 WHY SPECT / CT? SPECT / CT Basic Principles. Advantages of SPECT. Advantages of CT. Dr John C. Dickson, Principal Physicist UCLH

[PDR03] RECOMMENDED CT-SCAN PROTOCOLS

Total Variation Regularization Method for 3D Rotational Coronary Angiography

SUPPLEMENTARY INFORMATION

Optimization of Cone Beam CT Reconstruction Algorithm Based on CUDA

Tomographic Reconstruction

Transcription:

Extended parallel backprojection for standard three-dimensional and phase-correlated four-dimensional axial and spiral cone-beam CT with arbitrary pitch, arbitrary cone-angle, and 100% dose usage Marc Kachelrieß, a) Michael Knaup, and Willi A. Kalender Institute of Medical Physics, University of Erlangen Nürnberg, Germany Received 12 September 2003; revised 7 April 2004; accepted for publication 7 April 2004; published 27 May 2004 We have developed a new approximate Feldkamp-type algorithm that we call the extended parallel backprojection EPBP. Its main features are a phase-weighted backprojection and a voxel-by-voxel 180 normalization. The first feature ensures three-dimensional 3-D and 4-D capabilities with one and the same algorithm; the second ensures 100% detector usage each ray is accounted for. The algorithm was evaluated using simulated data of a thorax phantom and a cardiac motion phantom for scanners with up to 256 slices. Axial circle and sequence and spiral scan trajectories were investigated. The standard reconstructions EPBPStd are of high quality, even for as many as 256 slices. The cardiac reconstructions EPBPCI are of high quality as well and show no significant deterioration of objects even far off the center of rotation. Since EPBPCI uses the cardio interpolation CI phase weighting the temporal resolution is equivalent to that of the well-established single-slice and multislice cardiac approaches 180 CI, 180 MCI, and ASSRCI, respectively, and lies in the order of 50 to 100 ms for rotation times between 0.4 and 0.5 s. EPBP appears to fulfill all required demands. Especially the phase-correlated EPBP reconstruction of cardiac multiple circle scan data is of high interest, e.g., for dynamic perfusion studies of the heart. 2004 American Association of Physicists in Medicine. DOI: 10.1118/1.1755569 Key words: Cone-beam CT CBCT, cardiac imaging, 4-D reconstruction, image quality I. INTRODUCTION The ongoing development of medical cone-beam CT CBCT scanners requires providing cone-beam reconstruction algorithms adequate for medical purposes. These must be capable of handling arbitrary pitch standard and phasecorrelated reconstruction for circular, sequential and spiral trajectories. Flexible pitch selection in the range from about 0.3 to about 1.5 is used for dynamic studies to have full control over the table speed, and it is used for cardiac CT to adopt the amount of data overlap to the patient s heart rate. One further adjusts the pitch to compensate for tube power limits: low pitch values allow us to accumulate dose but increase the total scan time. Finding the best compromise requires flexibility in pitch selection; two or three distinct pitch values are certainly not enough. Due to the increasing dose awareness, it is further of importance to ensure 100% dose usage, which means that each measured ray contributes to the reconstructed images. As far as we know, three types of image reconstruction algorithms can be found in today s 16-slice medical CT scanners: z-interpolation, single-slice rebinning, and Feldkamptype image reconstruction. To reconstruct stationary objects standard reconstruction manufacturers use Feldkamp-based algorithms 1 6 or they use the so-called single-slice rebinning algorithms such as the advanced single-slice rebinning algorithm ASSR. 7 12 The reconstruction of periodically-moving objects such as the beating heart is done with phasecorrelated algorithms. There, two-dimensional z-interpolation algorithms dedicated for four-slice CT are adopted and used to reconstruct cardiac data for scanners with more than four slices. However, there are several restrictions to these approaches that may inhibit their use in scanners with significantly more than 16 slices. It is known that the Feldkamptype reconstruction of spiral data is of acceptable quality only if the direction of convolution corresponds to the direction of the spiral tangent. 13 Whereas this fact can be accounted for, a severe drawback is the use of a detector window similar to the Tam window 14 that results in pitchdependent dose efficiency values that are always significantly below 100%. The ASSR algorithm yields good image quality for scanners with up to 64 slices 7 and has been generalized for arbitrary pitch spiral CT with 100% dose usage. 15 Its generalization to cardiac scanning ASSRCI cardio interpolation yields good images only for as little as 16 to 32 slices. 15 Besides these restrictions, the development of wide cone angle medical CT scanners with large area detectors 64 slices or more will likely draw attention toward the circular scan trajectory. Especially cardiac CT is likely to push the development of reconstruction algorithms for circle scans. Assume a scanner with M 256 slices and a slice thickness of S 0.75 mm. The total collimated width of MS 192 mm is sufficient to cover the heart completely and a circle scan will be the trajectory of choice. This scan mode would allow us to increase temporal resolution simply by increasing scan overlap, which directly corresponds to the 1623 Med. Phys. 31 6, June 2004 0094-2405Õ2004Õ31 6 Õ1623Õ19Õ$22.00 2004 Am. Assoc. Phys. Med. 1623

1624 Kachelriess, Knaup, and Kalender: EPBP for CBCT 1624 scan time or the number of rotations used for a circle scan. 16 Even more important, the circle scan is the trajectory required for dynamic studies such as perfusion measurements. 17,18 To accommodate these demands, we developed and evaluated the extended parallel backprojection EPBP, which is a new class of standard and phase-correlated image reconstruction algorithms that handle circular scans, sequential scans and spiral scans with arbitrary pitch and 100% dose usage. 19,20 EPBP is a Feldkamp-type algorithm that performs azimuthal, longitudinal, and radial rebinning to parallel geometry before an extended 3-D cone-beam backprojection with voxel-dependent weights generates the final volume. Rebinning to parallel geometry using a slanted detector longitudinal rebinning has been discussed in the literature before. An example are the PI and the PI-SLANT algorithms. 21,22 However, these do not achieve a full detector utilization nor do these approaches allow for phasecorrelated reconstruction. Detector utilization itself has become an issue recently. For example, Ref. 23 proposes a new weighting scheme to improve the detector usage and to reduce image noise; 100% dose usage is not achieved, however. Also recently introduced was the extended cardiac reconstruction. 24,25 It uses only a simple illumination window and avoids longitudinal rebinning therefore the direction of convolution may not be optimal. The extended cardiac rebinning is evaluated for 16 slice scanners only. Efforts in circular or sequential image reconstructions for medical CT can be found in Refs. 26, 27. This group uses a parallel rebinning T-FDK extension of the original Feldkamp algorithm and achieves promising image quality. However, neither cardiac imaging is considered nor full dose usage is guaranteed due to the truncation of the detector to a virtual rectangular flat panel detector. Note that EPBP belongs to the class of approximate conebeam image reconstruction algorithms and could theoretically be outperformed by analytically exact reconstruction algorithms. However, even when considering recent breakthroughs in exact cone-beam reconstruction 28 these analytical methods are far away from providing a solution to the issues full dose usage and phase-correlated imaging. 13 In this paper we specifies EPBPStd and EPBPCI. It is organized as follows. A nomenclature section introduces most symbols. Then, the extended parallel backprojection algorithm EPBP is defined. Numerous simulation and measurement results demonstrate the capabilities of EPBP compared to the gold-standard four-slice spiral algorithms 180 MFI and 180 MCI 29 and ASSR. Due to the focus on medical CT imaging, we restrict our derivations and simulations to cylindrical detector systems that are centered about the focal spot and aligned parallel to the axis of rotation. This is no loss of generality since the respective rebinning equations can be equally well formulated and implemented for other detector types such as flat panel detectors. II. MATERIALS AND METHODS The projection or rotation angle is called. It will be used to parametrize the complete circular, sequential or spiral trajectory. The angle within the fan is given by, the ray s position along the detector s z-axis is denoted as b. The parallel ray geometry is parametrized by for the ray s signed distance to the origin and for its angle, and we use l for the parallel detector s longitudinal component. These notations conform to those in Ref. 9. The cardiac phase as a function of the view angle is denoted as c( ) and is to be taken modulo 1. It parametrizes the motion with respect to the motion synchronization peaks. In the case of ECG correlation, these peaks are taken as the R peaks of the ECG. We implicitly assume a correct handling of the modulo properties of c: floor function, yields greatest integer lower or equal ceil function, yields smallest integer greater or equal Dirac s delta function sgn( ) sign function such that x x sgn x,,b ray parametrization for the cylindrical detector R projection angle about which the reconstruction is centered B detector boundary, B b B, with B MSR FD /2R F length correction factor, cos 2 R 2 FD /(b 2 R 2 FD ) table increment per rotation spiral or between successive rotations sequence, d (0,0,d) fan angle, 2 sin 1 (R M /R F ), in our case 52 cos d,d cone angle, 2 tan 1 (B/R FD ), in our case up to 19.1 M number of simultaneously acquired slices, in our case 4,...,256 o,o origin of the scan trajectory, o (0,0,o) p sequential or spiral pitch, p d/ms p 0 (,,b) measured projection data p 1 (,,b) azimuthally rebinned projection data p 2 (,,l) azimuthally and longitudinally rebinned data p 3 (,,l) data rebinned to parallel geometry Q parameter used to quantify image quality r coordinate vector, r (x,y,z) R D distance from the detector to the center of rotation z axis ; in our case 470 mm R F distance from focus to center of rotation z axis ; in our case 570 mm R FD distance from focus to detector, R FD R F R D ; in our case 1040 mm R M radius of the field of measurement FOM ; in our case 250 mm S slice thickness; in our case 0.75 mm s focus trajectory w( ), ŵ( ) 180 -complete weight function and 180 normalized weight function C/W display window center and width of the reconstructed images

1625 Kachelriess, Knaup, and Kalender: EPBP for CBCT 1625 Cone-beam data were simulated using a dedicated x-ray simulation tool ImpactSim, VAMP GmbH, Möhrendorf, Germany. The scanner geometry was chosen corresponding to a modern medical CT scanner Sensation 16, Siemens Medical Solutions, Forchheim, Germany : 1160 projections per rotation and 672 channels per slice were simulated. Phantom definitions were taken from the phantom data base at http://www.imp.uni-erlangen.de/forbild except for the cardiac motion phantom that is defined in Ref. 30. For simulation, a 2 2 subsampling was used for the focal spot for the detector; integration time was simulated by subsampling the angular direction with two samples. The starting location of the spiral was z 1 72 mm 1 2d for the thorax phantom and z 1 72 mm d/p for the cardio phantom. For the circle scan we used z 72 mm and z 0 for the thorax and the cardio phantom, respectively. The thorax sequence scan started at z 72 mm. The angular position for the first view was 1 0 for all simulations. Poisson noise was added to the simulated data by undoing the log, adding noise, and performing the log again. The number of incident quanta were chosen to get a realistic noise value in the order of 10 HU within a 20 cm water phantom. Simulations were restricted to monochromatic beams and scatter was switched off to avoid introducing nonlinearities. Simulated and measured raw data were reconstructed using a the four-slice z-interpolation algorithms 180 MFI and 180 MCI, b the single-slice rebinning algorithms ASSRStd and ASSRCI, and c the EPBPStd and EPBPCI algorithms described in this paper. All reconstruction algorithms were implemented on a standard PC with dedicated image reconstruction and evaluation software ImpactIR, VAMP GmbH, Möhrendorf, Germany. III. NOISE AND RESOLUTION MEASUREMENTS To quantify image noise and spatial resolution we have performed reconstructions of a simulated 20 cm water phantom that has two delta objects embedded. Both delta objects are located at a3cmdistance from the isocenter. The first is the point x y 30 mm z and the second object is the line x y 30 mm. The data were simulated and reconstructed using the same parameters and algorithms as for the thorax and cardio motion phantom data. A voxel size of 0.1 mm, which is well beyond the expected resolution, was used to fully capture the point spread function. The reconstructed water phantom images were used to quantify noise and resolution as follows. The in-plane PSF was computed by computing 60 radial profiles within 180 through the delta object and by averaging these profiles for all radial angles and for all reconstructed z-positions. The computation included a bilinear interpolation between neighboring pixels. The axial PSF, also known as the slice sensitivity profile SSP, was determined from a longitudinal profile through the delta point. In-plane resolution and longitudinal resolution z effective slice thickness are defined as the full width at half-maximum FWHM of the in-plane PSF and the SSP, respectively. Image noise was computed as the standard deviation of the pixel values in a cuboid region of interest that extends over all reconstructed slices and over an transaxial area of 1 cm by 1 cm centered at x 30 mm and y 0. Further, a quality factor to relativize variations in resolution and/or image noise and/or pitch value was computed as p Q 2 3 z 2 ; 1 the constant of proportionality was chosen to obtain Q 100% for the gold-standard four-slice scan with p 1 reconstructed with 180 MFI. The rationale for the definition of Q is as follows. For a given dose and a given image reconstruction, the algorithm image noise variance 2 is inverse proportional to the size of the z-resolution element and to the third power of the size of the in-plane resolution element, i.e., 3 z 2 const. 31 Lower values of this constant imply higher image quality, and vice versa. Further, 2 is inverse proportional to the applied dose, which, in turn, is proportional to 1/p if the tube current is the same for all measurements, thereby dividing the variance by the pitch factor compensates for the differences in dose. IV. GEOMETRY Figure 1 a shows a view from the operator s viewpoint onto the CT gantry. The coordinate system is attached to the patient table. The z axis is defined to be the axis of rotation. The y axis is defined to point vertically upward for zero gantry tilt and the x axis is given by the orthonormality relation xãy z. Moving the table into the gantry yields increasing z positions. A. Fan beam The fan-beam geometry of medical CT scanners uses cylindrical detectors of radius R FD. The focal spot rotates at radius R F about the isocenter z axis and the patient table advances by d (0,0,d) during one rotation. We use R to denote the gantry rotation angle projection angle, 1/2,1/2 to denote the angle within the fan and b as the longitudinal detector coordinate. Let o (0,0,o) be the source s z position for 0. Then, the source location is parametrized F as follows: sin s R cos d 2 o. 2 0 The coordinate vector of the detector (,,b) is given as r,,b s R FD sin cos 0 b 0 0 1. 3

1626 Kachelriess, Knaup, and Kalender: EPBP for CBCT 1626 FIG. 1. a Gantry as viewed from the operator. The coordinate system is attached to the table. The direction of increasing counterclockwise rotation is indicated. b Coordinate system of a cylindrical detector scanner projected into the x-y-plane. The rays are described by the angle within the fan and the rotation angle of the gantry in fan geometry. The corresponding parameters in parallel i.e., rebinned geometry are and. c Side view onto the ray geometry of a scanner with M 4 slices. The midplane is the dotted line. 2B. Parallel beam For image reconstruction it is convenient to convert the data to in-plane parallel geometry. This means that the z-component of the rays is temporarily ignored, which corresponds to projecting the scan into the x-y plane. The parallel rays are parametrized by their distance to the center of rotation and by their angle with respect to the negative y axis. The ray itself is given by the expression ( ) R ( ). Thereby, we have introduced the unit vector pointing from the isocenter to the ray, and the ray s direction vector : cos sin, sin cos. This definition was chosen to have the central rays for the fan beam ( 0) and for the parallel beam ( 0) coinciding as long as. The normal form of the ray is the familiar expression x cos y sin 0. Please note that x cos y sin, y cos x sin, allow us to represent a given point r (x,y) asr in the rotated, coordinate system. C. Point projection For 3-D backprojection as it is performed in EPBP, for example, the perspective projection of a point r (x,y,z) in the spatial domain from the focal spot s onto the cylindrical detector is of interest, i.e., we are interested in its (,b) coordinates. 4 Transaxially, the one-to-one correspondence between a ray s fan-beam coordinates and its parallel beam coordinates is simple:, R F sin, as well as arcsin /R F, arcsin /R F, describe the same ray. Therefore, we are free to use the parallel beam coordinates when deriving the point projection coordinates. For the point r we can easily state that x cos y sin is its radial detector coordinate. From 5 we immediately find the point s coordinate. The longitudinal detector coordinate must be computed using the intersection theorem. The transaxial distance D of the respective voxel r (r cos,r sin,z) to the source s is given as D 2 R F sin x 2 R F cos y 2 R F 2 2R F r sin r 2. Alternatively cf. Figs. 2 or 1 b, we can obtain the relation D R F cos R F 2 2, with and given by 4. Now, compute b by scaling the axial distance z d( /2 ) o of the voxel s z coordinate and the source s z coordinate from D to R FD : b R FD D z d 2 o. 5 6a And, by representing sin by the quotient of the opposite leg and the hypotenuse see Fig. 2, we get another useful representation of : x cos y sin R F sin R F. 6b D

1627 Kachelriess, Knaup, and Kalender: EPBP for CBCT 1627 FIG. 3. Azimuthal and radial rebinning converts fan-beam into parallel-beam data. Longitudinal coordinates are not influenced. FIG. 2. In-plane illustration of the derivation of Eq. 6. Below, the quotient of 6a and 6b will play a role in determining the optimal direction of convolution along the detector. V. DEFINITION OF EPBP EPBP is an approximate 3D cone-beam image reconstruction algorithm concept suitable for various kinds of trajectories; in this paper we restrict our investigations to the circular, sequential, and spiral trajectory. In contrast to z interpolation and single-slice rebinning algorithms, a true 3-D backprojection of shift-invariant filtered cone-beam data is performed; therefore one might consider EPBP to be of the Feldkamp type. EPBP image reconstruction consists of the following steps: 1 Azimuthal rebinning: p 0 (,,b)cos p 1 (,,b). 2 Longitudinal rebinning: p 1 (,,b) p 2 (,,l). 3 Radial rebinning: p 2 (,,l) p 3 (,,l). 4 Convolution: p 3 (,,l) pˆ (,,l). 5 Weighting and backprojection: pˆ (,,l) f (x,y,z). Since our data are discretized, rebinning and backprojection always requires some kind of interpolation. We perform destination-driven rebinning and backprojection with a simple linear interpolation on the source side. In view of the high image quality we achieve with this standard approach, it is beyond the scope of this paper to test more sophisticated interpolation techniques. A. EPBP rebinning The general coordinate transform and the backward transform between a ray in fan-beam coordinates, and a parallel-beam ray, are given by 5. Medical cone-beam data are measured in the fan-beam domain. We use p 0 (,,b) to denote the acquired logarithmic attenuation data. The variable b denotes the longitudinal detector coordinate cf. Eqs. 2 and 3. Figure 3 illustrates that the fan-beam data can be converted into parallel beam data by a resorting or rebinning procedure. This transaxial rebinning is usually decomposed into an azimuthal and a radial rebinning step. In between both steps, EPBP performs a longitudinal rebinning. 1. Azimuthal rebinning The conversion of fan-beam data, to fan-parallelbeam data, is called azimuthal rebinning and corresponds to switching from the independent variable to the new independent variable : p 1,,b p 0,,b. On the rhs, (, ) is a function of the destination variables and according to Eq. 5. For the cone-beam algorithms a length correction factor cos defined by cos 2 R 2 FD /(b 2 R 2 FD ) is multiplied to the data during azimuthal rebinning to account for the obliqueness for the rays with respect to the x-y plane. 2. Longitudinal rebinning Until recently, many Feldkamp-type algorithms performed convolution along the direction of constant b just as it is the case with classical z-interpolation algorithms. However, severe image artifacts were observed, and these algorithms were found to be inacceptable for medical CT. It was the success of ASSR and the theory behind exact image reconstruction that indicated that convolution should rather be performed in the direction of the spiral tangent. 13 For performance reasons it is necessary to perform a rowby-row convolution. Consequently the fan-parallel data have to be converted into an adequate format. This is the reason why longitudinal rebinning is required. To derive the rebinning formula, we regard the tangent direction,

1628 Kachelriess, Knaup, and Kalender: EPBP for CBCT 1628 B. Convolution The remaining steps are convolution and weighted backprojection. Standard convolution kernels for parallel data such as the Shepp Logan kernel can be used for EPBP. Convolution yields convolved data, pˆ,,l p 3,,l *k. FIG. 4. Longitudinal rebinning includes an extrapolative extension of the detector gray to allow for convolution. The extrapolated areas white will be used exclusively for convolution and will not be used during backprojection. ds d, which is the optimal direction of convolution. The relationship between b and when moving an arbitrary object point along the direction ds and regarding its projection onto the detector can be derived using 6 : db d bd d d D R FD dz R F dx cos dy sin R FDd 2. 2 R F In the last step, the components of ds are inserted. Now, define a new longitudinal variable l as b l, with db d dr FD 2, 2 R F such that dl/d 0 in the direction of ds. Then, p 2,,l p 1,,b, with b b(,l) l l R F sin is the longitudinal rebinning that switches to l as the new independent variable. The convolution step that precedes the backprojection requires access to all R M,R M. To allow for longitudinal rebinning without losing parts of the original detector area b B,B we want to provide l within the range l (B R M ) 1,1. According to b l this, however, requires access to b (B 2 R M ) 1,1. We provide this area by extending the detector by a simple extrapolation that repeats the outermost detector rows only then, 100% dose usage can be achieved. This extrapolated area is used exclusively for convolution. Backprojection then respects the original detector area. Figure 4 illustrates the situation. Our procedure is justified because the main weight of the reconstruction kernel lies at its central element that never reaches extrapolated areas. We further have evaluated the influence of extrapolation on the final images by switching extrapolation on and off and found no negative effects. As already mentioned, the convolution exceeds the original detector limits and uses data of the extended detector. C. Weighting EPBP uses a voxel-dependent weight function a to perform phase-correlation and b to normalize the backprojected contributions to 180. The number of simultaneously scanned slices ranged from 4 to 256 in our simulations. Since submillimeter slice thicknesses are predominately used in today s scanners and since our clinical 16-slice scanner allows for 0.75 mm slices, we chose S 0.75 mm for all simulations and measurements. These parameters result in the following cone angles see Table I. With our implementation of EPBP, three kinds of scan trajectories are possible: the circular scan, the sequence scan, and the spiral trajectory. For the circular scan and for the sequence scan multiple circles, it is possible to analytically calculate the z range that is reconstructable within the FOM. This is best done using the results of Sec. III C. Dropping the d /2 term of 6a we find that z DB/R FD. Now, regard the point (R M cos,r M sin ) at the edge of the FOM. For that point we find D 2 R F 2 2R F R M sin( ) R M 2, whose value obviously changes while the scanner rotates about the point we fixed. If we want the point to be exposed during 360, one easily finds that the infimum value of D is R F R M, which is reached whenever the sine evaluates to one. This means z 1/2MS(1 R M /R F ) 1/2MS(1 sin 1/2 ) or, equivalently, d MS(1 sin 1/2 ) and p 1 sin 1/2 0.56. For data completeness, however, an exposure range of in fan-beam coordinates is sufficient. Choosing 1/2( ) 1/2 1/2( ) 1/2 yields D R F cos 1/2. In that case z 1/2MS cos 1/2 and p cos 1/2 0.90 follows. In cardiac CT, another degree of freedom is introduced. It is the relation of the patient s local heart rate f H to the scanner s rotation time t rot. It has been shown see Refs. 16, 30, and 31 that the decisive parameter is the product f H t rot. Thus, our cardiac results and image quality are not a function of f H and t rot but rather only a function of f H t rot. For convenience, we fixed t rot 0.5 s while varying the heart rate in a range from 60 to 120 min 1. Conversions to other rotation 3. Radial rebinning Data are then converted to parallel geometry via radial rebinning, p 3,,l p 2,,l. Here, ( ) is a function of according to Eq. 5. TABLE I. Cone angles. M 4 16 32 64 128 256 0.302 1.21 2.41 4.82 9.63 19.1

1629 Kachelriess, Knaup, and Kalender: EPBP for CBCT 1629 FIG. 5. Gold standard four-slice image reconstruction applied to four-slice data. The cardio data were simulated with p 0.375. Ticks indicate the location of the axial slices and the MPRs 0 HU/300 HU. times t rot, such as the frequently used 0.375 s and the 0.42 s rotation time, can be easily done by solving the relation f H t rot f H t rot. It is of help to introduce the visibility range V of the voxel r of interest: V(r) is the set of all view angles under which r is measured. The visibility range can be computed using the point projection equations of Sec. IV C. For the spiral trajectory, no closed analytical solution can be given and V must be determined numerically. Note that V is not an interval but a union of several disjunct intervals, in general. Given V phase weighting can be performed by defining a weight function w( ) that is zero in the complement of V and that is zero or positive in V. Several phase-weighting approaches are found in the literature, ranging from singlephase or partial scan methods such as the cardio delta approach described in Ref. 16 to bi-phase or even multi-phase approaches. In our case we use the cardio interpolation CI algorithm that is a multi-phase approach. It combines multiple allowed data ranges of subsequent motion cycles by using adaptive triangular weights for each data range. 16,30 The CI s technique of adaptively optimizing the temporal window width and thereby the temporal resolution led to the

1630 Kachelriess, Knaup, and Kalender: EPBP for CBCT 1630 FIG. 6. Standard and cardio reconstructions of the thorax phantom with p 0.375 and f H 100 min 1, various algorithms, and various cone angles. Axial slice at z 132.75 mm 0 HU/300 HU.

1631 Kachelriess, Knaup, and Kalender: EPBP for CBCT 1631 FIG. 7. Spiral scan with M 64 slices with two pitch values. Thorax phantom, standard reconstruction. Ticks indicate the location of the axial slices and the MPRs 0 HU/300 HU. development of similar approaches that are topic of ongoing research. 24 Since phase-correlation can always be formulated as a phase-weighting algorithm EPBP is able to cope with any phase-correlated approach. If one desires to perform a standard reconstruction, a weight function that is constant within V and zero outside can be used. A valid weight function has been found as soon as it fulfills the 180 condition, k Z w k 0, ; otherwise no CT images of sufficient quality can be provided. To avoid data combination artifacts, we further multiply the weight function obtained so far by trapezoidals covering each of the disjunct intervals of V. Thereby, a 7.2 transition range on each side of the trapeze is used in our implementation. Since w must be 180 complete, we further normalize the projection weight to get a 180 -normalized weight as follows: w ŵ k w k. The proper normalization of ŵ can be seen from the following identities: ŵ k 1 and d ŵ. k D. Backprojection Backprojection means evaluating f x,y,z d pˆ,,l ŵ, with x,y, x cos y sin, l b x,y,z,, arcsin /R F. This yields the voxel value at x, y, z. This procedure must be repeated for each voxel location r. Consequently, the weight function implicitly depends on r, too: ŵ( ) ŵ(r, ). Note that phase-correlation and the full dose usage both are hidden in the definition of the weight function which, in turn, depends on the voxel-dependent visibility range V. VI. SIMULATIONS AND MEASUREMENTS To evaluate our new approach and to benchmark it against the other algorithms, various simulations were performed. We restricted ourselves to the geometry of a medical CT

1632 Kachelriess, Knaup, and Kalender: EPBP for CBCT 1632 FIG. 8. Spiral scan with M 256 slices of the thorax phantom. Standard reconstruction. Ticks indicate the location of the axial slices and the MPRs 0 HU/300 HU. scanner with R F 570 mm, with 1160 views per rotation and a 52 fan angle that is transaxially covered by 672 detector elements. Summarizing, the following parameter set has been used for evaluation: M 4,16,32,64,128,256, p 0.375,0.5,0.9,1.0,1.5, f H 60,80,100,120 min 1, trajectory circle,sequence,spiral, algorithms 180 MFI,180 MCI,ASSRStd,ASSRCI, EPBPCI,EPBPStd ; some of these combinations are shown in Sec. VII. We appologize for not being able to show a comprehensive overview of all parameter combinations simulated and evaluated. The limited space of the paper does not allow us to do so. Nevertheless, we will also discuss some results that are not reproduced here. To quantify our results we have further computed the inplane point spread function PSF, the slice sensitivity profiles SSP that constitute the axial PSF and image noise. VII. RESULTS The four-slice algorithms 180 MFI and 180 MCI applied to four slice data have been chosen as the gold standard in that paper; the other algorithms must compare to that standard. Gold standard images are shown in Fig. 5. Please note that only the 180 MFI reconstruction with p 1 top right is used to normalize the Q factor of Eq. 1. Therefore it is the only figure where Q exactly equals 100%. A. Results for the spiral trajectory To give a first overview over the image quality that can be achieved with the variety of algorithms a compilation of axial images is presented in Fig. 6. It shows standard and cardio reconstructions of the thorax phantom reconstructed at z 132.75 mm for p 0.375. The gold-standard 180 MFI achieves high image quality in the case of four slices. With 16 slices, however, the humerus starts suffering from blurring artifacts. For higher pitch reconstructions not shown here, geometrical distortions become visible. The ASSR reconstruction of the same 16 slice data show no such artifacts. When moving to 128 slices or more not shown the ASSR s image quality becomes severely degraded, as expected. EPBP, in contrast, results in much better images. There are no geometrical distortions and no artifacts produced by the

1633 Kachelriess, Knaup, and Kalender: EPBP for CBCT 1633 FIG. 9. Spiral scan (p 0.375) with f H 120 min 1 of the thorax phantom with an increasing number of simultaneously scanned slices. Cardio reconstruction. Ticks indicate the location of the axial slices and the MPRs 0 HU/300 HU. high contrast bone structures for EPBP. Evidently, the low pitch EPBP reconstructions appear to be equivalent to the gold-standard reconstructions. For the cardiac images of Fig. 6, advantages of ASSRCI over 180 MCI at 16 slices are not apparent. With M 32 slices, clear improvements of EPBPCI over ASSRCI can be seen. Even for as many as 256 slices the EPBPCI does not suffer from distortion artifacts. However, slight artifacts in the tissue-equivalent parts of the phantom are visible. In all cases, the artifact behavior varies with the heart rate and with the chosen reconstruction phase not shown. This is because the allowed data ranges are a function of the heart rate and reconstruction phase. To give a more comprehensive overview, MPR displays are needed in addition to the axial images. The following sequence of figures shows the planes x 0 mm sagittal, y 0 mm coronal, and z 0 mm axial of the reconstructed thorax phantom. The remaining fourth quadrant is used to display the quantitative parameters for image noise, spatial resolution, and the quality index Q. Figure 7 shows ASSR and EPBP standard reconstructions of the thorax phantom for a 64-slice scanner and two pitch values. Axial as well as MPR views are presented. The phantom s ribs are made up of inclined hollow cylinder segments and can be seen in the axial and in the coronal images. They are of special interest since they tend to easily produce artifacts. For example, artifacts around the ribs are visible with ASSRStd for the p 1.0 scan. For EPBPStd, no rib artifacts

1634 Kachelriess, Knaup, and Kalender: EPBP for CBCT 1634 FIG. 10. Reconstructions of the cardiac motion phantom scanned with M 64 slices at 60 min 1 with various algorithms 0 HU/500 HU. are visible. The sagittal images show the sternum, the heart, and the spine. The vertebra, and similarily the transitions between the thorax and the shoulder segments, tend to produce high-frequency streak-like artifacts that are oriented horizontally. These are of little concern since realistic scans include scatter and physical objects that do not exhibit mathematically perfect alignment. A comparison to the 256-slice reconstructions of Fig. 8 shows still excellent images for

1635 Kachelriess, Knaup, and Kalender: EPBP for CBCT 1635 FIG. 11. Reconstructions of the cardiac motion phantom scanned with M 64 slices at 100 min 1 with various algorithms 0 HU/500 HU. EPBP whereas the ribs in the ASSR reconstructions are severely degraded. Again, the low pitch images are of better quality than the high pitch images. Regarding the quantitative values for these two figures, we find that image noise is increased with ASSR and the Q is below 100%. EPBP achieves remarkably high Q, which is mainly due to the lower image noise and due to the improved z resolution. The next series of figures shows phase-correlated recon-

1636 Kachelriess, Knaup, and Kalender: EPBP for CBCT 1636 FIG. 12. Sequence scan with p 0.375 and p 0.9 of the thorax phantom with an increasing number of simultaneously scanned slices. Standard reconstruction. Ticks indicate the location of the axial slices and the MPRs 0 HU/300 HU. structions of the thorax phantom which is stationary and of the cardiac motion phantom. Figures of merit given for the thorax phantom apply to the reconstructions of the motion phantom as well: the scan and reconstruction parameters are identical in both cases. The CI reconstructions of Fig. 9 have been synchronized using a heart rate of 120 min 1. ASSRCI shows significant blurring in regions off the rotation axis. Artifacts mainly manifest in the inclined ribs but also the sagittal display shows blurring. The vertebrae are not delineated very well and the MPRs appear smoothed. Even the humerus is significantly degraded. This is confirmed by the FWHM of the SSP that lies at 1.4 mm for the 64-slice scanner. In contrast to the advanced single-slice rebinning reconstruction, EPBP achieves good delineation of all structures, even for those that are far away from the rotation center. This applies for all cone angles simulated, i.e., up to 256 slices. The cardiac motion phantom is shown with various algorithms and three reconstruction phases in Figs. 10 and 11 for the heart rates 60 and 100 min 1, respectively. We used the spiral 64-slice scanner with p 0.375 to produce these images. The top row is reconstructed using the four-slice algorithms, the middle row is ASSR, and the bottom row is EPBP. The first column shows a standard reconstruction, for comparison, whereas the remaining three columns depict the motion phantom in the slow 0%, medium 30%, and high motion 50% phase, respectively. Inspecting the axial images, we find only little variations between the three algorithms. Here, EPBP tends to show slightly less motion artifacts. This can be seen especially in the slow motion phase 0% of S S of the 60 min 1 and of the 100 min 1 reconstructions Figs. 10 and 11. The 120 min 1 case that is not shown here exhibits motion artifacts for all algorithms and reconstructed phases. This behavior, which has already been thoroughly described and analyzed in Refs. 16, 30, 32, is due to the resonance behavior of the heart motion and the scanner rotation: both take place at a frequency of 120 min 1. At that frequency, the duration of the slow motion phase 20% of the cardiac cycle is as low as 100 ms. The cardio interpolation is not able to improve its temporal resolution by collecting data from adjacent motion cycles since these are in resonance with the rotation angle. Therefore, CI s temporal resolution is only 250 ms half of the rotation time and motion will even be seen in the slow motion phase. The same behavior is expected for the 60 min 1 case, which is also in resonance with the scanner. Here, however, the slow motion phase lasts 200 ms, which is only insignificantly lower than the 250 ms temporal resolution, and motion artifacts are not apparent see Fig. 10. For the 80 min 1 not shown and 100 min 1 reconstructions there is no resonance behavior and the algorithm s temporal resolution is high enough to freeze motion in the slow motion phase completely. One possibility to avoid resonance cases is adjusting the rotation time accord-

1637 Kachelriess, Knaup, and Kalender: EPBP for CBCT 1637 FIG. 13. Cardiac circle scan 1/0.375 rotations with M 256 slices at an increasing heart rate. EPBPCI reconstruction. Ticks indicate the location of the axial slices and the MPRs 0 HU/300 HU. ing to the patient s expected heart rate, as recommended in Refs. 16, 30, 32. Some manufacturers provide respective product implementations. More significant advantages of EPBP over the other algorithms can be found in the sagittal and coronar MPRs that show the 2 mm objects. Here, EPBPCI exhibits far less blurring in the z direction than 180 MCI and ASSRCI. B. Results for the sequence trajectory We have used EPBPStd to perform sequence reconstructions of the thorax phantom for two different pitch values and for M ranging from 16 to 256. Figure 12 shows examples with 32 and 256 slices. In all cases, image quality is satisfactory. Images are slightly better for the p 0.375 scan and artifacts in the MPR tend to increase for an increasing number of slices. Compared to the corresponding spiral scans and EPBPStd reconstructions e.g., the p 0.375 reconstruction of Fig. 7, we find the sequence trajectory to be competetive regarding image quality. In the sequence mode, EPBPCI combines allowed data segments in the order of 1/p adjacent rotations depending on the z position to become phase selective and to achieve a high temporal resolution. Since the sequence cardio scan mode seems to have no practical importance, we do not show respective results, however. C. Results for the circular trajectory Figures 13 and 14 show EPBPStd and EPBPCI reconstructions for circle scans of the thorax phantom and of cardio motion phantom, respectively. Since for EPBPCI the number of rotations has been chosen to be 1/0.375 the same amount of data overlap and hence the same temporal resolution as in the spiral case can be expected. From Fig. 14 we can see that the circle scan EPBP reconstruction behaves very well regarding the motion artifacts and the sharpness of the structures in the z direction. It is this trajectory that has the potential to perform dynamic CT studies of the heart in the near future. D. Patient data To demonstrate EPBP s capabilities of processing clinical data reconstructions of standard 12-slice CT data have been performed. Figure 15 shows axial slices and MPRs of one patient reconstructed with ASSR and EPBP in both the standard and cardio interpolation modes. The latter uses kymogram data for synchronization. 33 To illustrate the phase selectivity, two phases have been chosen for reconstruction: 0% and 50% of K K. EPBP achieves very high image quality with these medical data. The standard reconstructions are blurred due to the heart motion. Apparently, ASSRStd suffers from smooth

1638 Kachelriess, Knaup, and Kalender: EPBP for CBCT 1638 horizontal streaks that are not visible in the EPBPStd reconstruction. The CI reconstructions are of high quality for both reconstruction algorithms. Due to EPBP s higher spatial resolution, image noise is slightly increased compared to ASSR. This confirms our observations of the phantom study and can be compensated for by choosing smother reconstruction kernels. Similar results are obtained with the patient in Fig. 16: EPBP achieves excellent image quality that is of the same quality as today s state-of-the-art cardiac reconstructions. The reader should note that this good performance of EPBP for as few as 12 slices is far from evident. Since EPBP is designed to be used with scanners with far more slices and since EPBP performs complicated oblique integrations on the detector area, one might expect discretization and border effects to become dominating for small detectors. Fortunately, this is not the case. FIG. 14. The 256-slice cardiac circle scans of the cardiac motion phantom at various heart rates. Reconstruction: EPBPCI at the slow, medium, and high motion phase 0 HU/500 HU. VIII. DISCUSSION The extended parallel backprojection is a generalized algorithm that combines and improves the capabilities of several reconstruction approaches. EPBP is able to reconstruct data from circular, sequential, and spiral trajectories in both the standard mode and the phase-correlated reconstruction mode. It has been shown that the proposed algorithm achieves very high image quality for a huge range of parameters. EPBP performance has been demonstrated for scanners with as many as 256 slices, for pitch values ranging from 0.375 to 1.5, and for heart rates between 52 and 120 min 1. Further on, EPBP copes well with data stemming from today s 12- or 16-slice algorithms. Our quantitative results indicate that EPBP makes better use of the available data than ASSR: it achieves better resolution and lower image noise. This may be mainly attributed to the fact that the degree of approximation used with EPBP is less than for ASSR. Thereby, EPBP is even comparable to the gold standard 180 MFI and 180 MCI, respectively. However, the fact that EPBP s Q happens to be larger than that of 180 MFI must be taken with care: the quality factor does not take into account the complete shape of the point spread function; it rather accounts for one figure of merit, namely the full width at half maximum. As a general result, we further observed that reconstructions of low pitch data result in better image quality and less artifacts than reconstructions of high pitch data. Obviously due to the data redundancy scan overlap cone-beam artifacts are somehow averaged and appear less dominant. For cardiac reconstructions the same temporal resolution and the same motion artifact behavior as known from the older algorithms has been observed with EPBP. This applies even for the cardiac circle scan where no profound reports can be found in the literature, up to now. We have seen that the cardiac circle scan is comparable to the cardiac spiral scan except for few cases with increased motion artifacts. Our statements are valid for as many as 256 simultaneously scanned slices and probably more. Here, the recommenda-

1639 Kachelriess, Knaup, and Kalender: EPBP for CBCT 1639 FIG. 15. Patient example, 52 min 1 0 HU/1000 HU.

1640 Kachelriess, Knaup, and Kalender: EPBP for CBCT 1640 FIG. 16. Patient example, 70 min 1 0 HU/700 HU.

1641 Kachelriess, Knaup, and Kalender: EPBP for CBCT 1641 tion to use variable rotation times as a function of the heart rate can be put forward again. For the cardiac sequence scan one might even control the interscan delay as a function of heart rate to optimize the position of the allowed data windows. Currently, the only drawback is the reduction of reconstruction speed by a factor 2 5 depending on the pitch value compared to the z-interpolation approaches. Since our implementation is not yet optimized and since computational speed will increase according to Moore s law we find that reconstruction speed is not really an obstacle. Altogether, our results indicate that EPBP is an image reconstruction algorithm that handles the current and future demands of medical CT. It allows for arbitrary pitch spiral and sequential scans with or without phase correlation. Regardless of the cone-angle, EPBP ensures 100% dose usage and shows only minor cone-beam artifacts. Of particular interest is the cardiac circle reconstruction that even allows for dynamic studies of the heart especially when considering that commercial 64-slice CT systems have recently become available. a Send correspondence and reprint requests to PD Dr. Marc Kachelrieß, Institute of Medical Physics IMP, University of Erlangen Nürnberg, Henkestraße 91, D-91052 Erlangen. Telephone: 49-9131-8522957; fax: 49-9131-8522824; electronic mail: marc.kachelriess@imp.unierlangen.de 1 L. A. Feldkamp, L. C. Davis, and J. W. Kress, Practical cone-beam algorithm, J. Opt. Soc. Am. 1, 612 619 1984. 2 X.-H. Yan and R. M. Leahy, Derivation and analysis of a filtered backprojection algorithm for cone beam projection data, IEEE Trans. Med. Imaging 10, 462 472 1991. 3 X. Yan and R. M. Leahy, Cone beam tomography with circular, elliptical, and spiral orbits, Phys. Med. Biol. 37, 493 506 1992. 4 G. Wang, T.-H. Lin, P. Cheng, and D. M. Shinozaki, A general conebeam reconstruction algorithm, IEEE Trans. Med. Imaging 12, 486 496 1993. 5 Th. Köhler, C. Bontus, M. Grass, and J. Timmer, Artifact analysis of approximate helical cone-beam CT reconstruction algorithms, Med. Phys. 29, 51 64 2002. 6 H. Turbell, Cone-beam reconstruction using filtered backprojection, in Linköping studies in Science and Technology Dissertation No. 672, Linköping Universitet, 2001. 7 M. Kachelrieß, S. Schaller, and W. A. Kalender, Advanced single-slice rebinning in cone-beam spiral CT, Med. Phys. 27, 754 772 2000. 8 H. Bruder, M. Kachelrieß, S. Schaller, K. Stierstorfer, and T. Flohr, Single-slice rebinning reconstruction in spiral cone-beam computed tomography, IEEE Trans. Med. Imaging 19, 873 887 2000. 9 M. Kachelrieß, T. Fuchs, S. Schaller, and W. A. Kalender, Advanced single-slice rebinning for tilted spiral cone-beam CT, Med. Phys. 28, 1033 1041 2001. 10 S. Schaller, K. Stierstorfer, H. Bruder, M. Kachelrieß, and T. Flohr, Novel approximate approach for high-quality image reconstruction in helical cone beam CT at arbitrary pitch, SPIE Medical Imaging Conference Proc., Vol. 4322, pp. 113 127, 2001. 11 K. Stierstorfer, T. Flohr, and H. Bruder, Segmented multiple plane reconstruction a novel approximate reconstruction for multi-slice spiral CT, Phys. Med. Biol. 47, 2571 2851 2002. 12 L. Chen, Y. Liang, and D. Heuscher, General surface reconstruction for cone-beam multislice spiral computed tomography, Med. Phys. 30, 2804 2821 2003. 13 K. Sourbelle, Performance evaluation of exact and approximate conebeam algorithms in spiral computed tomography, in Berichte aus dem Institut für Medizinische Physik Shaker-Verlag, Berlin, 2002. 14 K. C. Tam, S. Samarasekera, and F. Sauer, Exact cone-beam CT with a spiral scan, Phys. Med. Biol. 43, 1015 1024 1998. 15 M. Kachelrieß, T. Fuchs, R. Lapp, D.-A. Sennst, S. Schaller, and W. A. Kalender, Image to volume weighting generalized ASSR for arbitrary pitch 3D and phase-correlated 4D spiral cone-beam CT reconstruction, Proceedings of the 6th International Meeting on Fully 3D Image Reconstruction, November 2001, pp. 179 182. 16 M. Kachelrieß and W. A. Kalender, Electrocardiogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart, Med. Phys. 25, 2417 2431 1998. 17 S. Ulzheimer, L. Muresan, M. Kachelrieß, W. Römer, S. Achenbach, and W. A. Kalender, Considerations on the assessment of myocardial perfusion with multi-slice spiral CT, Radiology 221, 458 2001. 18 M. Kachelrieß, Phase-correlated dynamic CT, IEEE International Symposium on Biomedical Imaging, 2004, pp. 616 619. 19 M. Kachelrieß and W. A. Kalender, Extended parallel backprojection for cardiac cone-beam CT for up to 128 slices, Radiology 225, 310 2002. 20 M. Kachelrieß and W. A. Kalender, Extended parallel backprojection EPBP for arbitrary cone angle and arbitrary pitch 3D and phasecorrelated 4D CT reconstruction, Proceedings of the 7th International Meeting on Fully 3D Image Reconstruction, June 2003, pp. Tu-Am2-3. 21 H. Turbell and P. E. Danielsson, An improved PI-method for reconstructing helical cone-beam projections, Conf. Rec. IEEE MIC, 1999. 22 H. Turbell, Three-dimensional image reconstruction in circular and helical computed tomography, in Linköping Studies in Science and Technology Thesis No. 760, Linköping Universitet, 1999. 23 K. Taguchi, B. Chiang, and M. D. Silver, New weighting scheme for cone-beam helical CT to reduce the image noise, in Ref. 20, pp. Mo-Am2-1. 24 R. Manzke, M. Grass, T. Nielsen, G. Shechter, and D. Hawkes, Adaptive temporal resolution optimization in helical cardiac cone beam CT reconstruction, Med. Phys. 30, 3072 3080 2003. 25 M. Grass, R. Manzke, T. Nielsen, P. Koken, R. Proksa, M. Natanzon, and G. Shechter, Helical cardiac cone-beam reconstruction using retrospective ECG gating, Phys. Med. Biol. 48, 3069 3084 2003. 26 M. Grass, Th. Köhler, and R. Proksa, 3D cone-beam CT reconstruction for circular trajectories, Phys. Med. Biol. 45, 329 347 2000. 27 Th. Köhler, R. Proksa, and M. Grass, A fast and efficient method for sequential cone-beam tomography, Med. Phys. 28, 2318 2327 2001. 28 A. Katsevich, Analysis of an exact inversion algorithm for spiral conebeam CT, Phys. Med. Biol. 47, 2583 2597 2002. 29 W. A. Kalender, Computed Tomography Wiley, New York, 2004. 30 M. Kachelrieß, S. Ulzheimer, and W. A. Kalender, ECG-correlated image reconstruction from subsecond multi-slice spiral CT scans of the heart, Med. Phys. 27, 1881 1902 2000. 31 R. A. Brooks and G. DiChiro, Statistical limitations in X-ray reconstruction tomography, Med. Phys. 3, 237 240 1976. 32 M. Kachelrieß, S. Ulzheimer, and W. A. Kalender, ECG-correlated imaging of the heart with subsecond multislice CT, IEEE Trans. Med. Imaging 19, 888 901 2000. 33 M. Kachelrieß, D.-A. Sennst, W. Maxlmoser, and W. A. Kalender, Kymogram detection and kymogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart, Med. Phys. 29, 1489 1503 2002.