Series AMEL20-MAZ 20 Watt AC-DC / DC-DC Converter

Similar documents
Series AMEL5-MAZ 5 Watt AC-DC / DC-DC Converter

Series AMEL20-AZ 20 Watt AC-DC / DC-DC Converter

Series AMES40-MAZ 40 Watt AC-DC / DC-DC Converter

Series AMEL10-MJZ 10 Watt AC-DC / DC-DC Converter

Series AME25-JZ 25 Watt AC-DC / DC-DC Converter

Series AME5-CJZ 5 Watt AC-DC / DC-DC Converter

Series AME10-VZ 10 Watt AC-DC / DC-DC Converter

Series AME60-MJZ 60 Watt AC-DC / DC-DC Converter

Series AMEPR30D-AZ up to 2A AC-DC LED driver

Series AMER120-AZ up to 5A AC-DC / DC-DC LED Driver / Converter

Series AMEPR60C-AZ up to 5A AC-DC / DC-DC LED Driver / Converter

Series AM1M-NZ 1 Watt DC-DC Converter

Series AM1S-Z 1 Watt DC-DC Converter

Series AM4T-Z 4 Watt DC-DC Converter

Series AM20EW-NZ 20 Watt DC-DC Converter

Series AM3G-NZ 3 Watt DC-DC Converter

VP ELECTRONIQUE MASSY - Tel

Model No. ( Single Output ) ATC-3.3S ATC-5S ATC-12S ATC-15S ATC-24S Max Output Wattage (W) 10W 10W 10W 10W 10W VAC or VDC

APM-40 SERIES FEATURES PRODUCT OVERVIEW. Model Selection Guide. Input Specifications. AC/DC Power Module 40W, Industrial & Medical Safety

Output Current Input Current Max. capacitive Load

12-15VDC (12V±5%) 24-28VDC (24V±5%)

MPM-U653-DCF-B M/N: MPM-U653-DCF-B. 650W Medical AC / DC SPECIFICATION FOR SWITCHING POWER SUPPLY. Revision History

Watts. xppower.com. General. Input. Environmental. EMC & Safety. Output. IT & Medical Approvals. Energy Efficiency Level V, CEC2008 & EISA 2007

IEC/EN/UL60950 & CE certified, EN55032 Class B

TMP & TMPM Series, 4 to 60 Watt. Order code Output power max. Output Efficiency

C B. Models. Ultra wide 4:1 input voltage 20 W DC/DC. edition and EN55032 class A

40 & 60 Watt Models. Low Leakage Current. EN61000 Compliant. Single & Multiple Outputs. Cover Kits Available

Datasheet. ACF-10 Series AC/DC Power Module 10W

AC-DC POWER SUPPLIES UNIVERSAL INPUT, 65 WATT MEDICAL APPLICATIONS MUI65 SERIES

Universal input VAC <150mW No load power consumption

Features. Regulated Converter. RAC35-G/OF 35 Watt 4 x 2 Open Frame RAC35- SG/OF. AC/DC Converter

12-15VDC (12V±5%) 24-28VDC (24V±5%)

C B. Models. Operating up to 5000m altitude 5 year product warranty

Universal input VAC <250mW No load power consumption -25 C to +80 C Operating temperature, with derating

Parameter Condition Min. Typ. Max. Internal Input Filter 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

Universal Power Supplies

Parameter Condition Min. Typ. Max. Internal Input Filter. nom. Vin = 230VDC 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

Series Specifications Ta= 25 C, nom. Vin, full load and after warm-up unless otherwise stated) Parameter Condition Min. Typ. Max.

MPO-120S Series. Single Output, 180W Compact, Open Frame AC/DC Power Supplies. Key Features:

Industrial Power Supplies

FEATURES. Nominal Output Voltage and Current

100BPS15 B. MDS Medical AC-DC Open Frame 15Volt, 100Watt / MDS-100BPS15 B ``` Highlights & Features. Safety Standards.

Output Voltage* (nom.)(adjustable)

Note1: Typ. efficiency is 230VAC and full load 12VDC 24VDC 48VDC ms 8ms 16ms 80ms

Enclosed Power Supplies

VER05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input. Output

Output Voltage* (nom.)(adjustable)

FDC20-48 S 05 W - HC PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd.

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

Constant Voltage Mode

POWERBOX Industrial Line PMR20W Series 20W 4:1 Single and Dual Output High Performance DC/DC Converter

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

MPU-120S Series. Single Output, 180W Compact, U-Channel AC/DC Power Supplies. Key Features:

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

040APS12 B MDS. MDS Medical AC-DC Open Frame 12Volt, 40Watt / MDS-040APS12 B ``` Highlights & Features. Safety Standards.

Electrical Specification for: efo Wide range AC/DC Single 12V Output 400W Power Supply Telkoor Part Number: CUSTOMER SIZE CAGE CO

Safety Standards. Model Number:

MPV1060RI4. Ultra Wide Input, Compact Industrial Grade, PV Power DC/DC Con vert ers. Key Features:

Safety Standards. Model Number:

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

TEP 100WIR Series, 100 Watt

060AAS19 B MDS. MDS Medical AC-DC Adapter 19Volt, 60Watt / MDS-060AAS19 B. Highlights & Features. Safety Standards. Model Number: General Description

Safety Standards. Model Number:

Industrial Power Supplies

Safety Standards. Model Number:

Safety Standards. Model Number:

Safety Standards. Model Number:

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Safety Standards. Model Number: Unit Weight:

60 Watt Medical (MWLT)

Safety Standards. Model Number:

DC-DC CONVERTERS SINGLE OUTPUT, 60 WATTS EXTREMELY WIDE 12:1 INPUT VOLTAGE RANGE: 9-75VDC, VDC RAILWAY APPLICATIONS

Safety Standards. Model Number:

4:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 88% Over Current and Over Voltage Protection No Minimum Load Required

efo Series Wide range AC/DC Single Output 1000W Rugged Power Supply Electrical Specification for: Telkoor Part Number:

Safety Standards. Model Number:

Industrial Power Supplies

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS24 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H):

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

TEP160-WIRCM SERIES 160 Watt High Density Brick DC-DC Converter Measures: 2.40 x 2.28 x 0.50

Output Voltage in Constant Voltage Mode. Model Number

Ripple & Noise (max) (See Note 2) 5V output: 100mVp-p; 12V - 27V outputs: 150mVp-p; 48V output: 200mVp-p

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Chrome DIN Rail Power Supply 12V 9.96W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1A

POWERSOLVE ELECTRONICS LTD PSL400-XX series Conduction Cooled Power Supply Engineering Specification

Environmental. Electrical Specifications at 25 O C E Output Constant Current

Safety Standards. Model Number:

Watts. xppower.com. General. Input. Output. Environmental. EMC & Safety. Compact Size. IT & Medical Approvals.

MPV1560RI4. Ultra Wide Input, Compact Industrial Grade, PV Power DC/DC Con vert ers. Key Features:

MVAD040 Series 40W 2" x 4" AC-DC Power Supply Converter

Sync DIN Rail Power Supply 5V 15W 1 Phase (NEC Class 2) / DRS-5V30W1NZ

Environmental. Electrical Specifications at 25 O C E Output Constant Current

VEL05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input

Application Package Dimension Output Input Output Output Protection Option Code Code Power Voltage Quantity Voltage Type (W) (VAC) (VDC)

Chrome Class II DIN Rail Power Supply 24V 10W 1 Phase (NEC Class 2 & Household) / DRC-24V10W1HZ

Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma (typ.) ma(typ.) VDC μf % MKW15-12S05M. Output Current Input Current Reflected Ripple

Features. Applications and Benefits TRC ELECTRONICS, INC

Packaging (5) Protection (3) Isolation Voltage (4)

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1A

ORDERING INFORMATION SEE PAGE 6

Transcription:

Click on Series name for product info on aimtec.com FEATURES: I/O Isolation 4000 Energy Star compliant Operating Temp: -40 o C to +70 o C Ultra-small package Over load, Over, Short Circuit Protection Up to 82% efficiency Universal Input: 90-264, 47-440Hz, or 130-170VDC Models Single output CB Model Input (/Hz) Input (VDC) Max wattage (W) (V) Current max (A) Maximum capacitive load (µf) Efficiency (%) AMEL20-3.3SMAZ 90-264/47-440 130-370 13.2 3.3 4 5600 74 71 AMEL20-5SMAZ 90-264/47-440 130-370 20 5 4 4700 77 77 AMEL20-12SMAZ 90-264/47-440 130-370 20 12 1.66 3300 80 79 AMEL20-15SMAZ 90-264/47-440 130-370 20 15 1.33 2200 80 81 AMEL20-24SMAZ 90-264/47-440 130-370 20 24 0.84 1000 77 79 Models Asymmetric Dual output Model Input (/Hz) Input (VDC) Max wattage (W) (V) Rated Current (A) Maximum capacitive load (µf) 115 230 Efficiency (%) AMEL20-3.35DMAZ 90-264/47-440 130-370 17.5 3.3/5 1.4/2.5 1000 75 76 AMEL20-3.312DMAZ 90-264/47-440 130-370 18 3.3/12 1.4/1.1 1000 78 78 AMEL20-3.315DMAZ 90-264/47-440 130-370 18 3.3/15 1.4/0.89 1000 77 77 AMEL20-3.324DMAZ 90-264/47-440 130-370 18 3.3/24 1.4/0.55 1000 76 76 AMEL20-512DMAZ 90-264/47-440 130-370 18 5/12 1.6/0. 83 680 76 77 AMEL20-515DMAZ 90-264/47-440 130-370 18 5/15 1.6/0.66 680 78 79 AMEL20-524DMAZ 90-264/47-440 130-370 18 5/24 1.6/0.46 680 75 76 AMEL20-1215DMAZ 90-264/47-440 130-370 18 12/15 0.66/0.66 560 77 78 AMEL20-1224DMAZ 90-264/47-440 130-370 18 12/24 0.58/0. 42 560 79 80 AMEL20-1524DMAZ 90-264/47-440 130-370 18 15/24 0.54/0. 42 560 80 81 AMEL20-3.3N5DMAZ 90-264/47-440 130-370 14.8-3.3/5-0.7/2.5 680 75 76 AMEL20-3.3N12DMAZ 90-264/47-440 130-370 18-3.3/12-1.4/1.1 680 76 77 AMEL20-3.3N15DMAZ 90-264/47-440 130-370 18-3.3/15-1.4/0.89 680 76 77 AMEL20-5N5DMAZ 90-264/47-440 130-370 14-5/5-0.8/2 680 75 76 AMEL20-5N12DMAZ 90-264/47-440 130-370 18-5/12-1.6/0. 83 470 75 76 AMEL20-5N15DMAZ 90-264/47-440 130-370 18-5/15-1.6/0.66 470 75 76 AMEL20-12N12DMAZ 90-264/47-440 130-370 18-12/12-0.66/0.83 470 77 78 AMEL20-12N15DMAZ 90-264/47-440 130-370 18-12/15-0.66/0.66 330 76 77 Note: Optional mounting plate version can be ordered by adding -ST suffix to part number (ex. AMEL20-5SMAZ-ST) * power must not exceed the listed values NOTE: All specifications in this datasheet are measured at an ambient temperature of 25 C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Current (full load) 115 500 ma 230 350 ma Inrush current <2ms (cold start) 115 30 A 230 50 A 115 230 F 052e R9.D 1 of 6 North America only

Input Specifications (continued) Leakage current 0.25 ma External fuse Recommended slow blow type 1.5 A Input dissipation 110/230Vac 1 W Start up time 50 ms Specifications accuracy ±2 % Line regulation ±1 % Load regulation (single output) 0-100% load ±2 % Load regulation (dual output) Unbalanced (0-100%) load ±3 % Transient recovery time 500 µs Transient response deviation 25% load step ±2 % of Vout Ripple & Noise* 3.3 & 5V models 100 150 12, 15 & 24V models 150 200 mv p-p Hold-up time 110 10 230 25 ms *Ripple and Noise are measured at 20MHz bandwidth & 230 by using a 0.1μF (M/C) and 47µF (E/C) parallel capacitor. Isolation Specifications Parameters Conditions Typical Rated Units Tested I/O voltage 60 sec 4000 Isolation resistance >1000 MΩ General Specifications Switching frequency 65 KHz Over load protection Foldback 150 % Over voltage protection Zener Diode Clamp Short circuit protection Auto recovery Protection class Class II Operating temperature See derating table -40 to +70 o C Maximum case temperature 100 o C Storage temperature -45 to +95 o C Temperature coefficient ±0.02 % / o C Cooling Free air convection Humidity Non condensing 20 ~ 95 % RH Case material Plastic (flammability to UL 94V-0) Weight 70 g Dimensions (L x W x H) 2.22 x 1.21 x 0.99 inches 56.48 x 30.86 x 25.10mm MTBF > 400 000 hrs (MIL-HDBK -217F, t=+25 o C)/Full Load > 100,000 hrs (MIL-HDBK -217F, t=at highest operating temperature)/full Load Environment Approval Test Parameters Conditions Wave form Half sine wave Acceleration amplitude 5gn Shock Bump duration 30 ms Converter operation before and after test, body mounted (on chassis) Number of bumps 18 (3 in each direction for every axis) Test mode Sweep sine Vibration Displacement 1mm Acceleration 3g Converter operation 10-100Hz, speed 0.05Hz/s F 052e R9.D 2 of 6 North America only

Safety Specifications Parameters Agency approvals Standards Additional Surge Protective Circuitry culus, CE, CB Medical Electrical Equipment IEC\EN\UL 60601-1, 2 x MOOP, CSA-C22.2 No. 601.1-M90 Information technology Equipment EN 60950-1:2006+A11:2009 EMI - Conducted and radiated emission EN55022, class B Harmonic Current Emissions IEC/EN 61000-3-2, Class A fluctuations and flicker IEC/EN 61000-3-3, (EN60555-3) Electrostatic Discharge Immunity IEC 61000-4-2, Contact ±4KV/Air ±8KV, Criteria A RF, Electromagnetic Field Immunity IEC 61000-4-3, 3V/m, Criteria A Electrical Fast Transient/Burst Immunity IEC 61000-4-4, ±1KV, Criteria A Surge Immunity IEC 61000-4-5, ±2KV, Criteria A RF, Conducted Disturbance Immunity IEC 61000-4-6, 3Vrms, Criteria A dips, Short Interruptions Immunity IEC 61000-4-11 Information Technology Equipment UL 60950-1:2007 Information Technology Equipment CAN/CSA-C22.2 No.60950-1-07 The AMEL20-MAZ series design level surge protection is certified to IEC 61000-4-5 surge Line to Line of 1KV. However greater protection can be enhanced by adding protective devices to ingress circuitry. For example, by adding an MOV (Metal Oxide Varistor) device example TVR10471KSY to the N / L input lines 2KV surge protection or greater, can be achieved. L N Fuse MOV + - Vo+ Aimtec AC-DC Converter Vo- Load Vrms Vdc Wmax (2ms) Pmax MOV PN V V J W TVR10471KSY 300 385 70 0.4 Pin Out Specifications Pin Single Dual positive Dual negative/positive 1 AC Input (L) AC Input (L) AC Input (L) 2 AC Input (N) AC Input (N) AC Input (N) 3 +V +V1 +V1 4 -V Common Common 5 No pin +V2 -V2 F 052e R9.D 3 of 6 North America only

Dimensions 5.27 56.46 (2.22) 45.72 (1.80) 30.86 (1.21) 20.32 (0.80) 5,27 1 2 Top View 5.37 The hottest area 3 4 5 10.20 (0.40) 10.20 (0.40) 5.37 1 2 Top View 3 4 5 DIV: 10.00 (0.40) 25.10 (0.99) 1.05 (0.04) 8.00 (0.31) 5Ø 1.0 (Ø 0.04) Dimensions mm (inch) Case Tolerance ±0.50 (±0.02) Pin Diameter 1.0 ± 0.05 (0.04 ± 0.002) Pin Pitch Tolerance ±0.35 (±0.014) Derating Free Air Convection 100 50 C Power (%) 80 60 40 Safe Operating Area 20 0 70 C - 40-20 0 20 40 60 80 100 Ambient Temperature º C F 052e R9.D 4 of 6 North America only

Derating (Dual Models) Free Air Convection 100 40 C Power (%) 80 60 40 Safe Operating Area 20 0 70 C - 40-20 0 20 40 60 80 100 Ambient Temperature º C F 052e R9.D 5 of 6 North America only

Dimensions of Optional ST Mounting Plate Version Pin Out Specification ST Version NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25 C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec s standard Terms of Sale available at www.aimtec.com. F 052e R9.D 6 of 6 North America only