TR TR 608 top TR 609 top D GB F I E NL. Installation and operating instructions Digital time switch. TR 609 top2

Similar documents
LUNA LUNA 120 top2 D GB F I E P NL PL. Installation and operating instructions Twilight switch. LUNA 120 top2

TR TR 610 top2 G

LUNA LUNA 111 top2 LUNA 112 top2 D GB F I E P , , Assembly and operating instructions Digital twilight switch

1. Basic safety information 4 2. Proper use 4

1. Basic safety information 3 2. Proper use 3

click DuoFix screwless Plug-in screwless terminal NC contact Test tap

RAMSES D GB F NL. Installation and operating instructions Room thermostat. RAMSES 832 top2

Operating instructions for RAMSES 811 top2_812 top2 and RAMSES 831 top2_832 top2

VARIA VARIA 826 S WH KNX VARIA 826 S BK KNX D GB F I E NL. Installation and operating instructions Room thermostat VARIA 826 S KNX

1. Basic safety information 4 2. Proper use 4

1. Basic safety information 4 2. Proper use 4

Data sheet no Data sheet General data sheet Status: 00 hst/ml Distribution: Valid from: Release: Device no.:

Plug-in screwless terminal NC contact. OBELISK top2 memory card ( )

D GB F NL I E P. Overview per day of the programmed switching. Channel statuses are displayed ON / OFF

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Switching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Product and Applications Description. Application programs. instabus EIB Technical Product Information. February 2012

DALI Professional Controller-4. Control unit Operating instructions

Instruction Manual Digital socket box timer

2. Safety information 3

7 Day Digital Programmer 2 Channel Surface Mount

Product and functional description

7 Day Digital Programmer 1 Channel Surface Mount

Push Button Interface UP 220D31

Demonstration Case BENNING DB 1

ZCM-12, ZCM-12P/U TIME PROGRAMMER WEEK S, DOUBLE CHANNEL

Digital time switch SHT-1/2 - two channel - with daily and weekly program. Operating manual. Content. 1. Before you start Features of the device

Model: EP210. Dual channel programmable controller. Installation Manual

FP735Si Electronic 3-Channel Full Programmer for Heating and Hot Water with Service Interval Timer. Installation Guide MAKING MODERN LIVING POSSIBLE

Product and functional description

E-STOP relays, safety gate monitors

Product and functional description

Product and function description

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

FS-21.doc Status Filter Control FS-21. EasyRange

Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact

Digital time switch - one channel - with daily and weekly program. Operating manual. Content. 1. Before you start Features of the device.

02/11/2015

Astronomical time switches

1 Safety instructions. 2 Device components. 3 Function. Control unit, 1-10 V 3-gang. Order-No. : Operating instructions

RIC PROGRAMMABLE INTELLIGENT CONTROLLER

Siemens Spares. RL 513D23 Switching actuator (relay), 3 x 6A. Technical Product Information

PSR UC/ESAM4/3X1/1X2/B

OPERATING MANUAL. Quality control system on the production complies with requirements ISO 9001:2008

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

02/11/2015

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

ZEITSCHALTUHR TIMER SWITCH TIJDSCHAKELKLOK KOPPLINGSUR RELOJ TEMPORIZADOR IDŐZÍTŐ KAPCSOLÓ ΧΡΟΝΟΔΙΑΚΟΠΤΗΣ DZ 20-A V2

Product and functional description

Electronic timer CT-ARS.11

PHARAO. Compact controllers for installation and automation technology

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

ETD-BL-1T-OFF-CC- 10S

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

Datasheet - SRB 402EM-24V

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

Product and functional description

DEUTSCH ENGLISH NEDERLANDS FRANÇAIS NORSK ITALANIO ČEŠTINA Hersteller DAB650SI

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. LB management. Universal rotary dimmer LED

Electronic time relays ATI, BTI, SDT and MTI

Electronic timer CT-ERS.21

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

Supplementary operating instructions for your air curtain system Controller TMC 500

is then retained absolutely without interruption.

Solid-state Timer. Ordering Information. Ultra-slim Timer for G2R Relay Socket. H3RN-jj. Accessories (Order Separately) Connecting Socket

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

Product and functional description

Installation and User Guide

RM84 miniature relays

The LED display (1) turns green when the load is switched on.

Safe timer relay/contact expansion modules

Bulletin 817 Thermistor Protection Relay

PHOENIX CONTACT - 01/2007

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E

Datasheet SRB301ST 24V (V.2)

ISOMETER isoev425 with coupling device AGH420

Model P4470 Save A Watt Operation Manual

Product information combined device with binary input / output, single BRE2-EB

16 Amp 1 Channel Multi Purpose Programmer User Instructions

Quick Start Installation and User Manual

11 Series - Light Dependent Relay A. Features pole 17.5 mm wide. 1 pole zero hysteresis 4 position selector

Manual Simatek Control Unit GFC 32

Nemo SX - Multifunction control module

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Electronic timer CT-ERS.12 ON-delayed with 1 c/o (SPDT) contact

1 Safety instructions. 2 Device components. 3 Function. Control unit 1-10 V, 3-gang. Art.-No.: 2193 REG. Operationsmanual

PSR DC/ESP4/2X1/1X2


BUP2 5/2 12/4/07 12:49 AM Page 1. Introduction

Operating instructions. Speed monitor D / / 2014

Technical data sheets

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

Transcription:

309559 01 TR TR 608 top2 6080100 TR 609 top2 6090100 L N 230-240V~ 3 µ 50-60Hz R10a -25T 2 1 16(4)A 250V~ GB Installation and operating instructions Digital time switch D GB F I E NL TR 609 top2 MENU OK 3 Ext1 2 1 max. 100 m N L L Connection of different external wires is permitted TR 609 top2

Contents Basic safety instructions 3 Display and keys Operating instructions 4 Connection/installation 5 Overview of menu selection 6 Initial start-up Reset 7 Menu item PROGRAMM Program switching time 8 Check/modify switching time 10 Delete switching time 11 Pulse time programming 12 Cycle time programming 14 Menu item TIME/DATE 15 Menu item MANUAL 16 Override and permanent switching 16 Menu item OPTIONS 18 Enter PIN code 19 External input 20 OBELISK top2 memory card 22 Technical data 23 Service address/hotline 24 2

Basic safety instructions GB WARNING Danger of death through electric shock or fire! Installation should only be carried out by a qualified electrician! The device is designed for installation on DIN top hat rails (in accordance with EN 60715) Corresponds to type 1 BSTU in accordance with IEC/EN 60730-2-7 / IEC/EN 60730-1 Power reserve (10 years) is reduced if memory card is inserted (in battery operation) Designated use The time switch can be used for lighting, bell systems, ventilation etc. Only use in enclosed dry spaces Do not use on safety devices, e.g. escape route doors, fire safety equipment etc. Disposal Dispose of device and batteries separately in an environmentally sound manner 3

Screen and keys Operating instructions Date display Time display Channel status ON = On AM PM OFF = Off Weekdays from 1 to 7 1. Read text lines Text represents query 2. Make a decision MENU MENU OK OK Activate screen Open menu Cancel menu ESC (1 step back) Store selection Confirm selection YES Confirmation NO Amend/ change Options are displayed Press OK Press 4

Connection/installation WARNING Warning, danger of death through electric shock! Must be installed by qualified electrician! Disconnect power source. Cover or shield any adjacent live components. 45 cable Ensure device cannot be switched on! Check power supply is disconnected. Plug-in terminal Earth and bypass. GB Connect cable Strip cable by 8 mm (max. 9 mm). Insert cable at 45 in the open terminal (2 cables per terminal position possible). Only with flexible wires: To open the plug-in screwless terminal, press screwdriver downwards. Plug-in screwless terminal NC contact Test tap 5

Overview of menu selection MENU 19 05 11 ON 35 9:40 1 PROGRAM TIME/DATE MANUAL OPTIONS NEW CHECK MODIFY TIME DATE SU-WI PERM ON PERM OFF OVERRIDE ON OPERATING HOURS EXTERNAL INPUT* LANGUAGE END DELETE WEEK DAY TIMER* PIN END FORME DATE HOLIDAY FACTORY SETTINGS FORME TIME RANDOM* INFO END END END * only with TR 609 top2 6

Initial start-up GB Set date, time and summer/ winter time rule Press required key and display follows on screen (see figure). RESET Press the 4 buttons simultaneously. You can choose between RETAIN PROGRAM and DELETE PROGRAM. ENGLISH RETAIN PROGRAM FORME DATE 3 1 0 5 1 1 YEAR MONTH DAY DELETE PROGRAM FORME TIME 24 h HOUR MINUTE SU-WI EUROPE or or SU-WI GB/IRL/P SU-WI FIN/GR/TR SU-WI CDN SU-WI USA ok SU-WI IRAN SU-WI NEW ZEALAND 19 05 11 ON 35 9:40 1 SU-WI OWN RULE NO SU-WI 7

PROGRAM Program switching time Example: Switch on sports hall lighting from Mon Fri, 7:30 to 12:00 hrs Press MENU. PROGRAM is displayed. Confirm by pressing OK. NEW is displayed. Confirm by pressing OK. SWITCH is displayed. Confirm by pressing OK. Select ON (for switch-on times). Confirm by pressing OK. The display shows HOUR. Use the + or keys to enter hour, minute, (07:30) and confirm by pressing OK. MONDAY is displayed. Confirm by pressing OK. COPY is displayed. Confirm by pressing OK. ADD TUESDAY is displayed. Confirm by pressing OK and also confirm the days Wed, Thurs, Fri by pressing OK. Continue with to SAVE is displayed. Confirm by pressing OK. Repeat all steps for the switch-off time however instead of selecting ON with select OFF and enter 12:00 for hour and minute. 8

MENU PROGRAM NEW GB SWITCH PULSE CYCLE END ON HOUR ON 7.30 MINUTE MONDAY TUESDAY WEDNESDAY COPY SAVE ADD TUESDAY... SAVE 84 memory locations are available (TR 609 top2). 9

Check/modify switching time Press MENU. PROGRAM is displayed. Confirm by pressing OK. NEW is displayed. Use to select CHECK. Confirm by pressing OK. Confirm SWITCH by pressing OK. The first of the entered switching times is displayed. Confirm by pressing OK. NEXT is displayed. MENU PROGRAM NEW CHECK MODIFY DELETE SWITCH MONDAY NEXT Change individual switching times Press to select MODIFY. Confirm by pressing OK. The display shows SWITCH. Confirm by pressing OK. The display shows the first time switch MONDAY. Confirm by pressing OK. The display shows CHANGE HOUR. Use the+ or keys to enter hour and minute and confirm by pressing OK. TUESDAY... MODIFY CHANGE HOUR CHANGE MINUTE CHANGE BLOCK DELETE... DELETED 10

Delete switching time GB Press MENU. PROGRAM is displayed. Confirm by pressing OK. NEW is displayed. Press to select DELETE. Confirm by pressing OK. The display shows SWITCH. Confirm by pressing OK. MONDAY is displayed. Confirm by pressing OK. The display shows DELETE BLOCK. Confirm by pressing OK. The display shows DELETED. MENU PROGRAM NEW DELETE SWITCH MONDAY DELETE BLOCK DELETED DELETE MONDAY DELETED With CLEAR MONDAY etc. individual days can also be cleared. 11

Pulse time programming (only with TR 609 top2) Example: Switch on pause signal on Monday 8:05 hrs for 5 sec Press MENU. PROGRAM is displayed. Confirm by pressing OK. NEW is displayed. Confirm by pressing OK. SWITCH is displayed. Select PULSE by pressing u. Confirm by pressing OK. ON is displayed. Confirm by pressing OK. The display shows HOUR. Use the + or keys to enter hour, minute, second (8:05) and confirm by pressing OK. PULSE LENGTH is displayed. Use the + or keys to enter the duration of the pulse in minutes and seconds (5 sec). Confirm by pressing OK. MONDAY is displayed. Confirm by pressing OK. COPY is displayed. Press to select SAVE. Confirm by pressing OK. 12

MENU PROGRAM NEW SWITCH PULSE CYCLE END GB ON HOUR ON 8.05 MINUTE SECOND PULSE LENGTH IN MINUTES Length 5 sec PULSE LENGTH IN SECONDS MONDAY TUESDAY WEDNESDAY COPY SAVE ADD TUESDAY... SAVE 13

Cycle time programming In addition to switch-on and switch-off times (switching time) and short time pulses (pulse) cycle times (cycle) can also be programmed. The pulse length (+ pulse pause) is limited to 17 hrs, 59 min, 59 sec Cycle times refers to cyclically repetitive time functions such as fan controls, urinal rinses etc. Example: Switch on water rinsing Monday from 8:00 to 20:30 hrs every 15 min for 20 sec (8:00 00 8:00 20 On; 8:15 00 8:15 20 On; 8:30 00 8:30 20 On etc.) Cycle programming Start cycle: Monday 8:00 hrs Pulse length: 20 sec Pause length: 14 min 40 sec Cycle end: Monday 20:30:00 hrs Observe the number of maximum electrical switching cycles when using the cycle function. 14

TIME/DATE In the menu TIME/DATE the TIME, DATE, SUMMER WINTER RULE, WEEKDAY etc. can be entered/changed in the submenus. Press MENU using u select DATE/TIME and follow the indications on the display. GB MENU TIME/DATE TIME SET DATE SU-WI WEEKDAY FORM DATE FORME TIME END HOUR YEAR SU-WI MONDAY 31 12 11 EUROPE 24 h MINUTE 20 10:15 MONDAY SU-WI 1 2 / 3 1 / 1 1 GB/IRL/P 02.05 DAY 11 12 31 02.05... 12 h AM PM 15

MANUAL In the MANUAL menu manual switch functions are applied. In the submenus MANUAL, PERMA- NENT ON/OFF, TIMER*, HOLIDAY, RANDOM the manual switching can be activated/programmed. Press MENU using u select MANUAL and follow the indications on the display. MENU MANUAL PERM ON PERM OFF OVERRIDE TIMER* HOLIDAY RANDOM* END ON PERM On 20 15:30 PERM On 20 PERM OFF END OVERRIDE On 20 15:30 TIMER On or. Off HOURS On 10 12:30 ON or OFF HOLIDAY START YEAR On 2011 RANDOM 1 RANDOM 2 * only with TR 609 top2... 16

Override and permanent switching Override and permanent switching can be set using the menu in MANUAL or in normal mode (automatic screen) by direct keystroke (see figures). GB Activate override Briefly press key. Activate permanent switching Press key for 2 sec. Cancel override/permanent switching Briefly press key again. Override Reversing the channel status to the next automatic or programmed switching. Permanent switching As long as a permanent switching (on or off) is activated, the programmed switching times are ineffective. 17

OPTIONS In the menu OPTIONS the submenus OPERATING HOUR, LANGUAGE, PIN, EXTERNAL INPUT, FACTORY SETTINGS as well as INFO can be requested. Press MENU using u select OPTIONS and follow the indications on the display. MENU OPTIONS OPERATING HOUR EXT INPUT* LANGUAGE PIN FACTORY INFO SETTINGS END SHOW HOUR DELETE NOT ACTIVE BUTTON DEUTSCH NO PIN or. WITH PIN LOAD FACTORY SETTINGS TR 609 TOP2 ENGLISH CURRENT PIN 0 0 0 0 0 0, 0 SERVICE SWITCH NEW PIN 0 2 0 5 1 1 END SAVED END... * only with TR 609 top2 18

Enter PIN code The PIN-Code is set in OPTIONS via the menu. If you have forgotten your PIN call the Theben Hotline. MENU OPTIONS GB OPERATING HOUR EXT INPUT LANGUAGE PIN ok WITH PIN NO PIN FACTORY SETTINGS CURRENT PIN INFO NEW PIN END 19

External Input (only with TR 609 top2) For the channel an EXTERNAL INPUT (see figure) can be set with different functions. Press MENU using u select EXT INPUT and follow the indications on the display. 3 submenus can be selected: Inactive, push button (function), switch (function) INACTIVE: The external input has no function PUSH BUTTON: Override (manual switching), timer (Countdown timer) can be selected. SWITCH: Permanently on, permanently off can be selected. Note: If a function is activated via an external push button or switch, EXTERNAL is displayed. 20

MENU OPTIONS GB OPERATING HOUR EXT INPUT* INACTIVE BUTTON* SWITCH OVERRIDE TIMER PERM ON PERM OFF TIMER ON HOUR MINUTE SECOND * Use push button without glow lamp 21

OBELISK top2 memory card Use memory card (see fig.) Insert memory card in the time switch. Read / read out saved switching times and device settings in the time switch or start Obelisk program. Remove memory card OBELISK top2 (No. 9070404) after copying Avoid mechanical stress or dirtying with other storage/transport methods. Copy OBELISK Time switch This copies the switching program (all standard and special programs) and optionally all time switch (e.g. Position, offset, external input, time format etc..) from the memory card in the time switch. Copy TIME SWITCH OBELISK This copies all switching programs and settings from the time switch to the memory card OBELISK COPY OBELISK -> TIME SWITCH TRANSCRIBE OK COPY TIME RUN SWITCH -> OBELISK OBELISK OVERWRITE OK CHECK OBELISK 22

Technical data Operating voltage: 230 240 V~, +10 %/-15 % Frequency: 50 60 Hz Power consumption: ca. 0,4 W Standby min.: ca. 0,4 W Switch output: switching of choice of external wires is permitted Contact: two way switch Gap: <3 mm (µ) Contact material: AgSnO 2 Max switching capacity: 16 A, 250 V~, cos ϕ = 1; 4 A, 250 V~, cos ϕ = 0,6 Min. switching capacity: 10 ma/230 V AC 100 ma/12 V AC/DC Incandescent lamp load: 1000 W Halogen lamp load: 1000 W Fluorescent lamp load: uncorrected, series corrected 1000 VA parallel correction 120 W (18µF) Compact fluorescent lamps: 40 W LED lamps: <2 W output, max. connection total of 10 W, >2 W < 8 W output, max. connection total of 25 W Permissible ambient temperature: 25 C... +55 C Protection class: II in accordance with EN 60730-1 subject to designated installation Protection rating: IP 20 nach EN 60529 Time accuracy: ±0,5 s/day at 25 C Power reserve: 10 years (lithium cell) at +20 C Pollution degree: 2 Rated impulse withstand voltage: 4 kv Max. switching cycles with 16 A resistive load: 50,000 23 GB

Service address/hotline Service address Theben AG Hohenbergstr. 32 72401 Haigerloch GERMANY Telephone +49 (0) 74 74/6 92-0 Fax +49 (0) 74 74/6 92-150 Hotline Telephone +49 (0) 74 74/6 92-369 Fax +49 (0) 74 74/6 92-207 hotline@theben.de Addresses, telephone numbers etc. www.theben.de The current OBELISK top2 PC software and the online version of the operating manual are available at www.theben.de 24