SITRANS F flowmeters SITRANS F US. SITRANS FUH1010 Oil clamp-on. 4/294 Siemens FI

Similar documents
SITRANS F flowmeters SITRANS F US. SITRANS FUS1010 Standard clamp-on. 4/270 Siemens FI Overview

Flow Measurement. SITRANS F US Clamp-on. SITRANS FUG1010 (Gas) 4/336 Siemens FI Overview

Flow Measurement SITRANS F US Clamp-on

SITRANS F flowmeters SITRANS F US

Flow Measurement. SITRANS F US Clamp-on. SITRANS FUG1010 (Gas) 4/336 Siemens FI Overview

Flow Measurement SITRANS F US Clamp-on

Flow Measurement SITRANS F US Clamp-on

Flow Measurement SITRANS F US Clamp-on

Flow Measurement. SITRANS F US Clamp-on. SITRANS FUE1010 (Energy) 4/317. Overview

SITRANS F flowmeters SITRANS F US. Flowmeter SONO 3300/FUS060 4/177. Technical specifications. Overview

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter

DigitalFlow GC868 Panametrics Clamp-On Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

ECHOMAX XPS-10 ULTRASONIC TRANSDUCER

Continuous level measurement Ultrasonic transducers

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/221

Level Measurement Continuous level measurement - Ultrasonic transmitters

Continuous level measurement Ultrasonic transducers

Ultrasonic Flow Meter Brochure

Continuous level measurement Ultrasonic transducers

TransPort PT878 Panametrics Portable Ultrasonic Liquid Flowmeter. GE Sensing. Applications. Features

Family of Water Cut Analyzers

SITRANS F C. Transmitter MASS 6000 Ex d compact/remote 3/195

TransPort PT878. Panametrics Portable Liquid Ultrasonic Flowmeter. GE Measurement & Control. Applications. Features

Model Sono-Trak General Specification

FH8500. Metering Solution for Custody Transfer Applications. One Step Ahead in Ultrasonic Flowmetering. Main Applications

Online data sheet. FLOWSIC100 Flare MASS FLOW MEASURING DEVICES

Level Measurement Continuous level measurement - Ultrasonic transducers

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M. Transmitter MAG 5000/ /34 Siemens FI Overview

Weighing Electronics Stand-alone integrators

Clamp-On Transit Time Ultrasonic Flow Meters

XONIC 100L ULTRASONIC TRANSIT-TIME FLOWMETER. User s Manual FOR LIQUID FLOW. Industrial & Military Instruments. January 2016

Flow Measurement SITRANS F C

RHE28. Field and Wall Mount Multifunction Coriolis Flow Transmitter

The. Hoffer Collection. Perfecting Measurement " A powerful source of Turbine Flowmeters and Electronics for a wide range of flow applications.

SONICMAX UL3400C. 3-BEAM Compact Ultrasonic Flowmeter OUTLINE FEATURES STANDARD SPECIFICATIONS

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES

UFD 5. Display for ALTOSONIC 5. Technical Datasheet. Configurable display for ALTOSONIC 5 Easy installation Durable design

Continuous level measurement Ultrasonic controllers

Level instruments. Continuous level measurement - Ultrasonic controllers SITRANS LUC500. 5/146 Siemens FI

KATflow 200 Hand-Held Clamp-On Ultrasonic Flowmeter

Flow Measurement SITRANS F C

Flow Measurement SITRANS F M

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

THE TECHNOLOGY BEHIND THE MEASUREMENT

OPERATING INSTRUCTIONS

NF770 Temperature Compensation Liquid Flow Computer

Level Measurement. Continuous level measurement Ultrasonic controllers. SITRANS LUT400 series 5/337. Overview

Micro Motion Model 2200S 2-Wire Transmitter with MVD Technology

SITRANS L Level instruments

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES

Series DMHF Heat Meter

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100 SERIES

Aysix 200 Hand-Held Flow Meter

RHE27. Rack/Panel Mount Multifunction Coriolis Flow Transmitter

Level Measurement Continuous level measurement - Ultrasonic transmitters

DIN-Rail Mounted Ultrasonic Flow Meter

Level measurement. Continuous level measurement Ultrasonic controllers. SITRANS LUT400 series. 4/146 Siemens FI Overview

Level Measurement Continuous level measurement - Ultrasonic controllers

DMTFP Portable Ultrasonic Flow Meters

PipeMonit Swarm. Real-time corrosion and erosion monitoring system. Non-Intrusive Wall Thickness Monitor

Selection and Ordering data. Selection and Ordering data

RHM160. Coriolis Mass Flow Meter for High Flow Terminal and Pipeline Applications. Features. Applications. Benefits

Proline Promass X 300 / 500 Abridged Specifications

Micro Motion 7845/7847 Series Density and Concentration Meters

Data sheet deltwavec-f

RHE27 Rack/Panel Mount Multifunction Coriolis Flow Transmitter

Level Measurement Continuous level measurement Ultrasonic controllers

Level instruments. Communications and Displays SITRANS RD200. 5/306 Siemens FI Technical specifications. Overview

Clamp-On Ultrasonic Flow- and Energy Meter For Liquids

Series TFXB Ultra. Transit Time Ultrasonic Flow Meter, Clamp-on, Liquid, Single-Channel

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR560. 5/2 Siemens FI Overview.

Siemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min.

Ultrasonic Heat Flow Meters

Continuous level measurement Radar transmitters

Level Measurement. Continuous level measurement Ultrasonic controller. SITRANS LUT400 series 5/337. Overview

UTM10 Series Ultrasonic Transit-time Flowmeters

Flow Measurement SITRANS F M. Transmitter MAG 5000/6000 4/33. Overview

Level instruments. Point level measurement - Capacitance switches. Pointek CLS200 5/15. Overview. Configuration

DCT7088 Portable Digital Correlation Transit Time Flowmeter

Batch Controller with numerical keypad, remote control inputs and 3 control / alarm / pulse outputs

EQUITY SERVICES & SOLUTIONS CO.,LTD. cono Flow

Flow Measurement SITRANS F C

Universal IV Water Cut Meter

Thermo Scientific CM515 and HME900 Density Converter Electronics

Scanner 2000 microefm

Variable Area Flowmeter DATASHEET

PanaFlow Gas Meter System

Level Measurement Continuous level measurement Ultrasonic controllers

RHE26. Rack/Panel/DIN Rail Mount Multifunction Coriolis Flow Transmitter

60 Ghz - Radar filling level sensor RFM 2000 C4 / R / MD

ATX MRE Series 16 and 32 Amp Multiple Socket Outlets Stationary and Portable. Increased Safety

Swarm. Real-time corrosion and erosion monitoring system. Non-Intrusive Wall Thickness Monitor

Assembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug

OPTIFLEX 1100 C Technical Datasheet

Transcription:

SITRNS F flowmeters Siemens G 2009 Overview Standard volume (net) or mass flowmeters ( standard volume / mass ) Exceptional repeatability is maintained, independent of changes in temperature, density or viscosity Batch interface and product quality diagnostics provided Density and PI outputs provided Scraper ( pig ) detection provided SITRNS FUH1010 clamp-on non-intrusive ultrasonic flowmeter is ideal for applications carrying crude oil, refined petroleum or liquefied gas. SITRNS FUH1010 has three application areas: Interface detectors, volumetric flowmeters and mass or standard volume flowmeters. Benefits For all FUH1010 products Easy installation; no need to cut pipe or stop flow Minimal maintenance; external transducers do not require periodic cleaning Design No moving parts to foul or wear No pressure drop or energy loss Wide turn-down ratio, 30:1 Choice of single, dual, or optional, three or four path versions. - Single path version reduces initial investment - Two or optional three and four path versions provide higher accuracy, especially where limited straight run or poor flow profile exists Wide-Beam technology - Helps provide improved accuracy over a wide range of liquid conditions and flow rates - ccommodates pipelines transporting multiple liquid products Zeromatic Path automatically corrects for zero drift without stopping flow Interface detectors / Density meters ( interface detector ) Outputs liquid density and PI as a direct replacement for intrusive densitometers Exceptional repeatability is maintained, independent of changes in temperature, pressure or viscosity No need for straight run Viscosity compensated volumetric flowmeters ( precision volume ) Moderate cost Precise measurement is maintained with automatic Reynolds Number compensation for temperature and viscosity changes. pplication Interface detectors / Density meters Precise identification of interfaces on multi-liquid pipelines Rapid and precise scraper pig indication Product identification Density indication Viscosity compensated volumetric flowmeters pplications with multiple liquids having a wide viscosity range utomatic gross volume compensation due to viscosity changes Standard volume (net) mass flowmeters Standard (net) volume flow measurement Suitable for use in leak detection systems Mass flow output measurement Interface detection Pig detection Chemical and petrochemical processing FUH1010 is available in three enclosures: IP65 (NEM X) Enclosure constructed of fiberglass reinforced polyester with stainless steel hardware and polyester keypad - Single path - Dual path - Optional four path IP65 (NEM 7) Compact explosionproof enclosure constructed of cast aluminum with glass window, stainless steel hardware - Single path - Dual path (option) IP66 (NEM 7) Wall mount explosionproof enclosure constructed of cast aluminum, stainless steel hardware, optional glass window - Single path - Dual path - Four path (optional) There are 2 types of mounting assemblies - luminum mounting frames (default) - Stainless steel weld seal (optional) Function IP65 (NEM X) and IP66 (NEM 7) flow meters have integral 33 button keypads and large (128 x 20 pixel) graphic displays visible up to 12 m (0 ft) away IP65 (NEM 7) compact flow meters has a 2 x 16 alphanumeric LCD display Current, voltage, status alarm, frequency and RS232 outputs (see specification section for details) nalog inputs (see specification section for details) Zeromatic Path automatically corrects for zero drift Bidirectional flow operation 1 MByte data logger with both site and data logger storage English, spanish, german, italian and french language options /29 Siemens FI 01 2010

Siemens G 2009 SITRNS F flowmeters Technical specifications Specifications for interface detectors ccuracy ccuracy ± 0.05 of PI No. Repeatability ± 0.01 of PI No. Specifications for volumetric and mass flowmeters Input Flow range ± 12 m/s (± 0 ft/s), bidirectional Flow sensitivity 0.0003 m/s (0.001 ft/s), flow rate independent ccuracy Calibratable accuracy ± 0.15% 0.3% of flow, depending on version Batch repeatability ± 0.05% of flow, maximum Specifications for all FUH1010 products Input Pipe size 6. mm... 9.1 m (0.25... 360 ) nalog inputs Current: x... 20 m (IP65 (NEM 7) enclosure has (2)) Output Standard outputs Current: x 20 m (1 kω at 30 VDC) Voltage: 2 x 0 10 V DC (5 kω minimum) (None for IP65 (NEM 7) enclosure) 1 x 0... 5 khz Pulse Rate, Digital uad. (None for IP65 (NEM 7) enclosure) RS232 Serial Port Enhanced outputs MODBUS (not for IP65 (NEM 7) enclosure) RS232 standard Up to x additional... 20 m (not for IP65 (NEM 7) enclosure) x Mercury wetted relays (not for IP65 (NEM 7) enclosure) Up to x digital pulse (not for IP65 (NEM 7) enclosure) Status/larm I/O x Programmable relays (not for IP65 (NEM 7) enclosure) 2 x Optically coupled output logic gates (for IP65 (NEM 7) enclosure, only) 1 x Totalizer clear switch input (not for IP65 (NEM X) enclosure) 1) 1 x Totalizer hold switch input (not for IP65 (NEM 7) enclosure) 1) 1 x Opto iso. totalizer clear switch input (for IP65 (NEM 7) enclosure, only) 1) 1 x Opto iso. totalizer hold switch input (for IP65 (NEM 7) enclosure, only) 1) ccuracy Zero Drift Data refresh rate 0.0003 m/s (0.001 ft/s), with Zero- Matic Path active (not provided for interface detector) 5 Hz (80 Hz output for flow rate available on special order) Rated operation conditions Degree of protection Wall mount enclosure IP65 (NEM X) Compact explosionproof IP65 (NEM 7) Wall mount explosionproof IP66 (NEM 7) Liquid temperature Standard -0... +120 C (-0... +250 F) Optional -0... +230 C (-0... +50 F) mbient temperature -18... +60 C (0... 10 F) Design Dimensions see Clamp-on System info and selection guide Weight see diagrams Power supply IP65 (NEM X) and IP66 (NEM 7) Wall Mount IP65 (NEM 7) Compact Indication and operation Data logger memory Display IP65 (NEM X) and IP66 (NEM 7) Enclosures IP65 (NEM 7) Enclosure Keypad IP65 (NEM X) and IP66 (NEM 7) Enclosures IP65 (NEM 7) Enclosure Language options 90... 20 V C, 50 60 Hz, 30 V or 9... 36 V DC, 12 W 90... 20 V C, 50... 60 Hz, 15 V or 9... 36 V DC, 10 W 1 MByte 128 x 20 pixel LCD with backlight 2 x 16 lphanumeric LCD Display 33 keypad buttons with tactile feedback 5 Magnetic hall effect switches English, Spanish, German, Italian, French 1) Totalizer switch inputs are not provided for the interface detector Siemens FI 01 2010 /295

SITRNS F flowmeters Siemens G 2009 Certificates and approvals IP65 (NEM X) flow display computer ratings FM and CS I.S. Class I, II, Div 1 N-I Class I, Div 2 S Class II, Div 2 TEX Ex II (1) G [EEx ia] IIC EX II 3 (1) G EEx nc [ia] IIC T5 Ex II 1 G EEx ia IIC T5 Ex II 2 G EEx m II T5 for use with flowmeter in safe area only INMETRO (Brazil) [BR-Ex ia] IIC BR-Ex nc [ia] IIC T5 BR-Ex ia IIC T5-50 C Ta +60 C IP65 (NEM 7) compact explosionproof enclosure ratings FM and CS XP Class I, Div 1 D-I Class II, Div 1 I.S. Class I, Div 1 N-I Class I, Div 2 S Class II, Div 2 TEX Ex II 2 (1) G EEx d [ia] IIB + H2 T5 Ex II 1 G EEx ia IIC T5 INMETRO (Brazil) BR-Ex d [ia] IIC T5 BR-Ex ia IIC T5-50 C Ta +60 C IP66 (NEM 7) wall mount explosionproof enclosure ratings FM and CS XP Class I, Div 1 D-I Class II, Div 1 I.S. Class I, Div 1 N-I Class I, Div 2 S Class II, Div 2 TEX Ex II (1) G [EEx ia] IIC Ex II 3 (1) G EEx nc [ia] IIC T5 Ex II 2 (1) G EEx d [ia IIC] IIB + H2 T5 Ex II 1 G EEx ia IIC T5 INMETRO (Brazil) [BR-Ex ia] IIC BR-Ex d [ia IIC] IIB + H2 T5 BR-Ex ia IIC T5-50 C Ta +60 C /296 Siemens FI 01 2010

Siemens G 2009 SITRNS F flowmeters Standard MLFB for quick delivery on SITRNS FUH1010 (Hydrocarbon liquid meter) Selection and Ordering data Order No. Order code K) 7 M E 3 6 0 7-7777 0-7 7 7 7 K 1 2 + K 1 2 + R 1 2 Design (Includes cable glands) IP65 (NEM X) 0 Number of ultrasonic paths/meter type Dual path (DV-Standard Volume/Mass) Flowmeter functions and I/O configurations includes graphic or digital display, IP66 (BNB6665 (NEM X)) and IP66 (NEM 7 wall mounted) units: Standard Graphic display x... 20 m analog input 2x 0... 10 V 2x... 20 m 2x pulse outputs Mercury wetted relays 2x RTD input Meter power options 90... 20 V C Communication options RS 232 (standard) 0 RTD temperature sensor (includes mounting hardware for pipes above 1.5 outer diameter) No RTDs (Note: Temperature input is required for FUH1010 systems) 0 1 x submersible clamp-on RTD 3 Transducer for channel 1 (includes pipe mounting kit and spacer bar for indicated max. outer diam. listed) C1H (high precision) Mounting frame and 1200 mm (8") M C2H (high precision) Mounting frame and 1200 mm (8") N D1H (high precision) Mounting frame and 1200 mm (8") P D2H (high precision) Mounting frame and 1200 mm (8") Transducer for channel 2 (includes pipe mounting kit and spacer bar for indicated max. OD listed) See Transducer selection charts for specifications. C1H (high precision) Mounting frame and 1200 mm (8") M C2H (high precision) Mounting frame and 1200 mm (8") N D1H (high precision) Mounting frame and 1200 mm (8") P D2H (high precision) Mounting frame and 1200 mm (8") pprovals FM/CS (default) 1 TEX EExia 2 Standard MLFB product offering represents to 6 weeks delivery time K) Subject to export regulations L: N, ECCN: 5991X. Siemens FI 01 2010 /297

SITRNS F flowmeters Siemens G 2009 IP65 (NEM X) IP65 (NEM 7) compact Number of ultrasonic paths / meter type Single path (precision volume) 0 Single path (interface detector) 1 Dual channel/dual path (interface detector) 2 Dual path (precision volume) 3 Dual path (standard volume / mass) Special: Four path (standard volume/mass) 9 H 1 only Flowmeter functions and I/O configurations Includes graphic or digital display IP65 (NEM X) and IP66 (NEM 7 wall mounted) units Standard - Graphic display - x... 20 m analog input - 2 x 0... 10 V - 2 x... 20 m analog output - 2 x pulse output - x Mercury wetted relays (form C for interface detector) -2xRTD input Enhanced I/O option C - additional 2 x... 20 m outputs - Form C relays - x digital pulse outputs (2 x open collector and 2 x 0... 5 V TTL) IP65 (NEM 7) compact units Standard D - Digital display - 2 x... 20 m (Loop) - 2 x... 20 m analog input - 2 x status (open collector) -1xRTD input Digital pulse option F - 1 x digital pulse open collector output - 2 x... 20 m (Loop) - 2 x... 20 m analog input - 1 x status (open collector) -1xRTD input Other version (Expanded I/O for non-custody Z J 1 Y meters or dry contact relays for custody) dd order code and plain text. Other version (Mercury wetted or dry contact relays) dd order code and plain text. - Dry contact form C relays for standard Z J 1 meter - Mercury wetted relays for enhanced I/O Z J 1 D meters Meter power options 90... 20 V C 9... 36 V DC (except compact NEM 7) B 9... 36 V DC negative GND (compact only) J 9... 36 V DC positive GND (compact only) K Communication options RS232 (standard) 0 MODBUS (excludes NEM 7 compact) 1 IP65 (NEM X) IP65 (NEM 7) compact RTD temperature sensor (includes mounting hardware for pipes above 1.5 OD) No RTDs (Note: temperature input is required 0 for FUH systems) 1 x standard clamp-on RTD 1 2 x standard clamp-on RTD 2 1 x submersible clamp-on RTD 3 2 x submersible clamp-on RTD Special (for insert style RTDs) 9 N 1 Y Transducer for channel/path 1 (includes standard pipe mounting kit and spacer bar for indicated max. outer diameter listed) See Transducer selection charts for specifications For the following 1H to DH transducers, temperature range is -0 C to 65 C (-1 F to 150 F), nominal 21 C (70 F): 1H (high precision) Trackmount and straps G 2H (high precision) Trackmount and straps H 3H (high precision) Trackmount and straps J B1H (high precision) Trackmount and straps K B2H (high precision) Trackmount and straps L B3H (high precision) Trackmount and straps T C1H (high precision) Mounting frame and M C2H (high precision) Mounting frame and N D1H (high precision) Mounting frame and P D2H (high precision) Mounting frame and D3H (high precision) Mounting frame and U DH (high precision) Mounting frame and R 1) Supplied spacer bar supports pipes up to 750 mm (30 inches). For pipes larger than 750 mm (30 inches) purchase also, spare part 7ME3960-0MS0 (1012BN-). K) Subject to export regulations L: N, ECCN: 5991X. /298 Siemens FI 01 2010

Siemens G 2009 SITRNS F flowmeters IP65 (NEM X) IP65 (NEM 7) compact Transducer for channel/path 1 (continued) Other versions (different size, mount, type or Z P 1 Y pipe larger than DN 1200 (8 ) or corrosion resistant), add Order code and plain text. For the following B1H to DH transducers, temperature range is -1 C up to 10 C (30 F up to 220 F), nominal 65 C (150 F): B1H (high temperature range HP) Z P 1 K B2H (high temperature range HP) Z P 1 L B3H (high temperature range HP) Z P 1 T C1H (high temperature range HP) Z P 1 M C2H (high temperature range HP) Z P 1 N D1H (high temperature range HP) 1) Z P 1 P D2H (high temperature range HP) 1) Z P 1 D3H (high temperature range HP) 1) Z P 1 U DH (high temperature range HP) 1) Z P 1 R Transducer for channel/path 2 (includes pipe mounting kit and spacer bar for indicated max. outer diameter listed) See Transducer selection charts for specifications For the following 1H to DH transducers, temperature range is -0 C to 65 C (-1 F to 150 F), nominal 21 C (70 F): 1H (high precision) Trackmount and straps G 2H (high precision) Trackmount and straps H 3H (high precision) Trackmount and straps J B1H (high precision) Trackmount and straps K B2H (high precision) Trackmount and straps L B3H (high precision) Trackmount and straps T C1H (high precision) Mounting frame and M C2H (high precision) Mounting frame and N D1H (high precision) Mounting frame and P D2H (high precision) Mounting frame and D3H (high precision) Mounting frame and U DH (high precision) Mounting frame and R Other versions (different size, mount, type or pipe larger than DN 1200 (8 ) or corrosion resistant), add Order code and plain text. Z 1 Y IP65 (NEM X) IP65 (NEM 7) compact For the following B1H to DH transducers, temperature range is -1 C up to 10 C (30 F up to 220 F), nominal 65 C (150 F): B1H (high temperature range HP) Z 1 K B2H (high temperature range HP) Z 1 L B3H (high temperature range HP) Z 1 T C1H (high temperature range HP) Z 1 M C2H (high temperature range HP) Z 1 N D1H (high temperature range HP) 1) Z 1 P D2H (high temperature range HP) 1) Z 1 D3H (high temperature range HP) 1) Z 1 U DH (high temperature range HP) 1) Z 1 R pprovals FM/CS (default), also for non hazardous 1 area TEX 2 INMETRO (Brazil) 3 Special TEX EEx m 9 R 1 Y add Order code and plain text: Length of integral cable:... 1) Supplied spacer bar supports pipes up to 750 mm (30 inches). For pipes larger than 750 mm (30 inches) purchase also, spare part 7ME3960-0MS0 (1012BN-) K) Subject to export regulations L: N, ECCN: 5991X. Selection and Ordering data Further designs Please add -Z to Order No. and specify Order code(s). Cable assembly for transducers (add for # of paths) See Transducer cable selection chart Cable assembly for RTDs (add for # of RTDs) See RTD cable selection chart Cable termination kit (for one cable pair) Termination for standard, plenum and armored transducer cable Termination for submersible cable RTD cable termination kit for standard RTD RTD cable termination kit for submersible RTD Languages (Meter and Documentation), English (default) German French Spanish Italian Tag name plate Stainless steel tags with 3.2 mm (0.13 inch) characters (26 characters max.) Stainless steel tags with 3.2 mm (0.13 inch) characters (68 characters max.) Order code K.. R.. T01 T11 T21 T31 B10 B12 B13 B1 Y17 Y19 Siemens FI 01 2010 /299

SITRNS F flowmeters Siemens G 2009 MLFB example pplication example clamp-on meter is required for a 12 carbon steel hydrocarbon line flowing multiple products, with a wall thickness of 12.7 mm (0.5 ). Meter electronics are to be located in a Class I Div 2 area only 60 ft from the pipeline. 12 V DC power is available at the site. Dual path operation is desired for improved accuracy and redundant measurement. Pulse output will be primary flow data source. MLFB Order No.: 7ME3600-3CB00-31-Z K03 + K03 + R03 FUH1010 meter family 7 M E 3 6 0 7 - IP65 (NEM X) enclosure 0 Dual path precision volume 3 Custody Transfer option with C digital pulse 9... 36 V DC power option B RS232 Standard 0 RTD required for viscosity comp 3 Transducer code for path 1 Transducer code for path 2 FM approval required 1 30 m (100 ft) transducer cable for K 0 3 path 1 30 m (100 ft) transducer cable for K 0 3 path 2 30 m (100 ft) cable for RTD R 0 3 Transducer Selection Chart High precision transducers for steel pipe with outer diameter/wall thickness ratio >10 Transducer Order Code Pipe wall (mm) Transducer Cable Selection Chart Pipe wall (inches) Size code min. max. min. max. 1H G 0.6 1.02 0.025 0.0 2H H 1.02 1.52 0.0 0.06 3H J 1.52 2.03 0.06 0.08 B1H K 2.03 3.05 0.08 0.12 B2H L 3.05.06 0.12 0.16 C1H M.06 5.8 0.16 0.23 C2H N 5.8 8.13 0.23 0.32 D1H P 8.13 11.18 0.32 0. D2H 11.18 15.75 0. 0.62 DH R 15.75 31.75 0.62 1.25 B3H T 2.7 3.3 0.106 0.128 D3H U 7. 9.0 0.293 0.35 Transducer cable codes for length and type options Cable length m (ft) Standard (PVC jacket) -0 +80 C (-0 +176 F) Submersible (polyethylene jacket) -0 +80 C (-0 +176 F) Plenum Rated (teflon jacket) -0 +200 C (-0 +392 F) rmored Order code 6 (20) K01 K11 K21 K31 15 (50) K02 K12 K22 K32 30 (100) K03 K13 K23 K33 6 (150) K0 K1 K2 K3 61 (200) K05 K15 K25 K35 91 (300) K06 K16 K26 K36-0 +80 C (-0 +176 F) RTD Cable Selection Chart RTD cable codes for length and type Cable length m (ft) Standard (teflon wrapped) -0... +200 C (-0 +392 F) Order code 6 (20) R01 R11 15 (50) R02 R12 30 (100) R03 R13 6 (150) R0 R1 61 (200) R05 R15 91 (300) R06 R16 Submersible (extruded jacket) -0... +200 C (-0 +392 F) K) Subject to export regulations L: N, ECCN: 5991X. /300 Siemens FI 01 2010