Quick Guide NC-200. NucleoCounter. to the easiest cell count ever!

Similar documents
NucleoCounter NC-200, NucleoView NC-200 Software and Code of Federal Regulation 21 Part 11; Electronic Records, Electronic Signatures (21 CFR Part 11)

Guide for 21 CFR part 11 on NucleoView NC-200

SomaticView Version 1.0

Summit Software WorkList Builder Quick Start Guide

StarWind iscsi SAN Software: Getting Started with V5

Protein Quantification Kit (BCA Assay)

Data acquisition and analysis of MACSPlex Cytokine Kits using the MACSQuant Analyzer Express Modes in MACSQuantify Software version 2.

Work Smart: Windows 7 New Features

StarWind Virtual CD: Using as DVD-ROM Emulator

StarPort iscsi and ATA-over-Ethernet Initiator: Using as RAM Disk Emulator

LEGENDplex Data Analysis Software Version 8 User Guide

StarWind iscsi SAN Software: ESX Storage Migration

PLTconnect. PLT unit software. Operating Manual

Data acquisition and analysis of MACSPlex Exosome Kit using the MACSQuant Analyzer Express Mode in MACSQuantify Software version 2.

Spectrometer Visible Light Spectrometer V4.4

12.0 Setting up the PC ready for BESA 11

StarPort iscsi and ATA-over-Ethernet Initiator: Using as ATA-over-Ethernet Initiator

hp digital home networking phoneline USB network adapter hn210p quick start guide

FACCalibur Users Guide

BD CellQuest Pro Acquisition Tutorial

Software Installation Quick Start

Applied Biosystems Attune Cytometric Software version 1.2 Release Notes

Colony Counting User Manual A D I V I S I O N O F S Y N O P T I C S L T D

QUICK START GUIDE FIRMWARE UPDATE VIA MIRA SOFTWARE APPLICABLE TO ALL PATH MEDICAL DEVICES

Quick Start Guide. SP Usage Simulator Tool. Evaluating the Performance of SharePoint Environment Using the New DocAve SP Test Environment Creator

Vision Express Engraver S5 Installation Guide Vision Engraving & Routing Systems

Powerline Communication

MATERIALS PLUS Segmentation Measurement

Phoenix 1212 Engraver S5 Installation Guide Vision Engraving & Routing Systems

Data acquisition and analysis of MACSPlex Cytokine Kits using the MACSQuant Analyzer Express Modes in MACSQuantify Software version 2.

Vision VE810 Engraver S5 Installation Guide Vision Engraving & Routing Systems

Cellometer Auto M10, Cellometer Auto T4 & Cellometer Auto T4 Plus User Manual

StarPort iscsi and ATA-over-Ethernet Initiator: Using as DVD-ROM Emulator

BD CellQuest Pro Software Acquisition Tutorial

Darca Plus Eltek Download ing And Remote Con trol Applica tion

Copyright 2014 Eppendorf AG, Germany. No part of this publication may be reproduced without the prior permission of the copyright owner.

eturboware 4.x For Windows 2000/XP User s Guide Part No: M , Ver:1.0

M User s Guide

Learning Secomea Remote Access (Using SiteManager Embedded for Windows)

Vision Express Vision VE810 Installation Guide Vision Engraving & Routing Systems

Mic qpcr. Fast. Accurate. Compact. Ultimate Performance for Real-Time PCR. Speed Accuracy Size Connectivity

User Manual Data-Logger Software

FRAGMENT ANALYSIS USING ABI 3730/3730XL HANDBOOK. Fragment Analysis using ABI 3730/3730xL, 7-B406, version Devyser AB, 2018 Page 1 of 11

Troubleshooting Guide

Rhopoint Instruments Ltd. Novo-Gloss Trio Operation Manual

MCS-TOUCHSCREEN Auto Disk Clean up

DRIVE DOCK. User Guide

Quick Start Guide GV-VMS

Veriti Thermal Cycler

DEPOSITPARTNER INSTALLATION GUIDE Desktop Application

CLEARVIEW KIT INSTALLATION GUIDE

Getting Started With DO Analyser Software Version 4

PPALoG. Data Logging Software. Software User Manual

BioPAK Installation Guide

Science is hard. Flow cytometry should be easy.

Gallios TM Quick Reference

MiBio Reference Manual

Virtual Owl. Guide for Windows. Office of the Chief Information Officer. Learning Technologies, Training, Audiovisual, and Outreach

Need More Help? VD containing BrightLink training videos in this Welcome Kit.

ScannerCal Accuracy Verification System for the FlowScanner

ProtoTRAK RX Homestead Place Rancho Dominguez, CA USA T F Service Department:

Quick Setup & Getting Started

PENMOUNT DEVICE DRIVER USERS GUIDE FOR MICROSOFT WINDOWS

KLIM AIM GAMING MOUSE

Printer Combo Adapter QUICK START GUIDE VERSION 1.1

BrightLink Welcome Kit

OP WINEDIT Configuration Software. Manual Number OP WINEDIT M

User s Manual. TBS-380 Mini-Fluorometer. Operating Manual. Dated: 08/14/2007 Rev. E

Overview. Experiment Specifications. This tutorial will enable you to

Firmware Update Function

Tutorial: FCAP Array Software with BD FACSArray Bioanalyzer

Webview Help Guide. OnSite Telemetry System. Distributed by: Chart Inc th Street NW New Prague, MN USA (800)

CyAn ADP Guide. Starting Up

CH142: Instructions for the Vernier LabPro

Podium Plus Data Analysis Software. User Manual. SWIS10 Version

i-disk Shield 2.0 Secure AES Manager User s Manual

Optical Disc Laminator

Comet Assay IV PERCEPTIVE INSTRUMENTS

PixelPro 3.0 User Manual

Guide to running KASP TM genotyping reactions on the Roche LC480-Series instruments

FloMax Software for Cytometry. Operating Manual Instrument Control and Acquisition. FloMax Operating Manual Instrument Control and Acquisition

User Guide DYMO Label TM v.8

Rotor-Gene AssayManager v1.0 Quick-Start Guide

Vision 1612, 1624, 2424 and 2448 Installation Guide

OPC Redundancy and Data Concentration Using the OPC DA Driver Agent

SOFTRAID LITE XT. User Guide. an Other World Computing brand

SOFTRAID XT. User Guide. an Other World Computing brand

Getting Started in FCS Express for Previous FlowJo Users

Cytomics FC 500 Quick Reference

DRIVE DOCK. User Guide

1. What s New in Bio-Plex Manager 6.1

CELLQuest Acquisition Tutorial

HID Real-Time PCR Analysis Software

StarBurn: Audio Compressor Wizard

NucleoCounter YC-100 Automatic Yeast Cell Counter (software version 3.00 or higher)

EcoStudy Software User Guide

StarBurn: Video Burner Wizard

MachineShop Supplemental Installation

Rotor-Gene AssayManager v2.1 Quick-Start Guide

Operator Manual. MS1000 Software. Trencher Monitoring System

Transcription:

Quick Guide to the easiest cell count ever! NucleoCounter NC-00

How to get started Dear NucleoCounter Customer! Thank you for purchasing the NucleoCounter NC-00 offering not only the easiest one-step viability and cell count ever, but also analysis of your cells where other cell counters give up! The NucleoCounter NC-00 Concept One step viability and cell count No pre-treatment Fast and easy operation Maintenance and service free Safe sample handling and disposal Excellent reproducibility User adaptable counting protocols Flexible software package 1 CFR part11 ready NucleoView Software Included on a USB stick for an unlimited no. of installations. Via1-Cassettes For one-step viability and cell count. Contain Acridine Orange and DAPI. Solution 10 Can be used for disaggregation of aggregating cells. NC-00 laptop stand Can be used to minimize footprint and facilitates even easier operation. How to get started - 8 easy steps to install the NC-00 Unpack the NC-00 instrument and plug it in the main outlet. Do NOT connect the USB cable to the PC. Make sure that there are full administrator rights on the PC during the installation of the NucleoView NC-00 software. Insert the USB stick in the PC and open the Install_Guide.html file for detailed installation instructions. Open the Install NucleoView NC-00 X.X.X.X.exe file (the X s indicate the version number e.g. 1.0..0). Do NOT open the.bin file. Follow the instructions on the screen. After the software installation it may be required to restart the PC. Open the NucleoView NC-00 software by double clicking on the NC-00 icon on the desktop to start the installation of the instrument. Connect the PC to the NC-00 instrument with the USB cable when the software tells you to do so. When the LED indicator light on the instrument turns green it is ready to use. Please read manual for detailed instructions

How to Perform the One-step Viability and Cell Count Analysis Easiest cell count ever! The NucleoCounter NC-00 from ChemoMetec is a signiant step forward for automated cell counting. No need to add buffers or dyes. No need to calibrate. Just prepare your cell suspension, load it into the disposable Via1-Cassette, place the cassette in the instrument and press run! Select protocol from the menu: Viability and Cell Count Assay Optional: Enter Sample ID and Operator Name Load the sample into a Via1-Cassette and Press Run 3 1 3

How to Perform Total Cell Count of Aggregated Cells Select the protocol from the menu: Count of Aggregated Cell Assay Optional: Enter Sample ID and Operator Name Add equal volumes of Solution 10 and your cell sample to a microcentrifuge tube and mix Immediately load your sample into a Via1-Cassette and press Run The compensation for the sample dilution with Solutions 10 is automatically performed by the software. However, if the proportions are different from those above please add the correct volumes in the input fields under the image window prior to running your assay. The entered volumes are used for calculating the cell concentration in the original cell sample. 1 3 4 4

How to Perform Total Cell Count and Viability of Aggregated Cells Select the protocol from the menu Viability and Cell Count - Aggregated Cells Assay Optional: Enter Sample ID and Operator Name Add equal volumes of Solution 10 and your cell sample to a microcentrifuge tube and mix. Retain an aliquot of at least 00 μl cell suspension without Solution 10 for analysis in step 5. Immediately load your sample into a Via1-Cassette and press Run After analysis, follow the on-screen prompt and load a sample of your cells NOT treated with Solution 10 and press Run. The compensation for the sample dilution with Solutions 10 is automatically performed by the software. However, if the proportions are different from those above please add the correct volumes in the input fields under the image window prior to running your assay. The entered volumes are used for calculating the cell concentration in the original cell sample. 1 3 4 5

Optional: Visual Inspection of Counting Gates OPTION Click the green dot in the right-hand corner of the image window. This activates the image overlay function indicating the events included in the total cell count. The mouse scroll button allows the user to zoom in at the cursor position. Cells will be framed by a pink square. (PREFERRED) OPTION (ADVANCED) Right-click on the sample file name in the Data folders and files window and select Show counting gates in Plot Manager. A new window will open displaying scatter plots and histograms of event intensity and size for the appropriate channels (AO and DAPI). It is important that the core of the population, usually seen as a coloured region on the scatter plot, is included in the square counting gate. Note it is not required that all events be included in the counting gate. Events in the lower, left-hand corner of the scatter plot are often smaller than cells and considered debris. 6

Only If Required: Create your own protocol with Adjusted Counting Gates 1 Step 1: Perform the desired type of assay on a sample of the cells to be analysed. In the Tools menu select Protocol Adaptation Wizard or rightclick on the desired file and select Start Protocol Adaption Wizard. Step : Follow the instructions in the Protocol Adaptation Wizard to create your own adapted protocol. The viability and cell counts results will not be adjusted for the image file used for the adaption of counting gates. New results can only be obtained by running a new sample with the new gating protocol. 7

Additional Resources Go to www.chemometec.com to find: Documentation MSDS Online ordering of consumables Certificates of analysis FAQ s Webinars etc. Consumables/accessories/kits: Item no. Description 941-001 Via1-Cassette, 1 box (100 pcs.) 910-3010 Solution 10 - Lysis Buffer, 100 ml 910-0003 Reagent A100 - Lysis Buffer, 500 ml 910-000 Reagent B - Stabilizing Buffer, 500 ml 974-0001 PQ Test Kit (For check of Viability & Cell Count Assay) 91-0010 NucleoCounter NC-00 IQ/OQ Kit 99-0011 Laptop Stand for NC-00 Can be ordered at www.chemometec.com or at your local distributor Disclaimer Notices The material in this document and referred documents is for information only and is subject to change without notice. While reasonable efforts have been made in preparation of these documents to assure their accuracy, ChemoMetec A/S assumes no liability resulting from errors or omissions in these documents, or from the use of the information contained herein. ChemoMetec A/S reserves the right to make changes in the product design without reservation and without notification to its users. 991-005A ver. 07.01 Copyright Notices Copyright ChemoMetec A/S 01. All rights reserved. No part of this publication and referred documents may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the prior written consent of ChemoMetec A/S, Gydevang 43, DK-3450 Allerod, Denmark. ChemoMetec and NucleoCounter are registered trademarks owned by ChemoMetec A/S. NucleoCounter, NucleoCassettes, and NucleoView are trademarks of ChemoMetec A/S. All other trademarks are the property of their respective owners. ChemoMetec A/S Gydevang 43 DK-3450 Allerod Denmark Phone (+45) 48 13 10 0 Fax (+45) 48 13 10 1 Mail contact@chemometec.com Web www.chemometec.com