CU Compact-Flash card adapter for USB. Version: 1.0 Date:

Similar documents
CU port USB 2.0 hub. Version: 1.1 Date:

CU USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date:

Installation- and Operating instructions for CU CFast card adapter with USB connector. Version: 1.1 Date:

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

Installation- and Operating instructions for CU Port USB 2.0 Hub. Version: 1.3 Date:

Installation- and Operating instructions for CU Port USB 3.0 Hub. Version: 1.1 Date:

Operation Manual BK5000. Bus Coupler for CAN-CAL Version: 1.12

C9900-P223 and C9900-P224

Documentation KM2042. Sixteen channel digital output module with D-Sub Connector. Version: Date:

Documentation EM2042. Sixteen Channel Digital Output Module with D-Sub Connector. Version: Date:

Installation- and Operating instructions for CU CP-Link 4 transmitter box The Two Cable Display Link. Version: 1.

C9900-P208 and C9900-P209

Documentation. KM2604 and KM2614. Four channel relay module. Version: Date:

Documentation. CU20xx, CU22xx. Ethernet Switch. Version: Date:

EL9820/EL9821 Evaluation Kit. Version: 1.3 Date:

Documentation. KM10xx. Terminal Modules with Digital Inputs. Version: Date:

Documentation ZB8610. Fan cartridge for EtherCAT and Bus Terminals. Version: Date:

Documentation KM2002, KM2004, KM2008. Terminal modules with digital outputs, 24 V, 0.5 A. Version: Date:

DeviceNet ILxxxx-B520. IO Data Mapping DeviceNet Objects Indicators and Switches

Installation and Operating instructions for Control Cabinet PCs C63xx

Operating instructions for AX5801. TwinSAFE drive option card for the AX5000 servo drive. Version: Date:

KL , KS

Installation and Operating instructions for Industrial PC series C61xx

Installation and Operating instructions for Built-in Industrial PC C6525

Documentation. Mains filter AX2090-NF50. Version: Date:

Documentation KL channel Digital Output Terminal, 24 V DC, 2 x 4 A/1 x 8 A. Version: Date:

KL Channel Resistor Bridge Input Terminal Configuration Instructions

Installation and Operating instructions for C Ultra compact Industrial PC. Version: 1.3 Date:

Installation and Operating instructions for. Control Cabinet PC C6210. Version: 1.4 Date:

KL Channel Analog Input Terminal 10 V V Configuration Instructions. Version

Installation and Operating instructions for Industrial PC series C61xx from Version: 3.0 Date:

EL9800 Base Board. Version: 1.9 Date:

Installation and Operating instructions for. Built-in Control Panel CP6608. Version: 1.0 Date:

Installation and Operating instructions for Control Cabinet PC C6915

Installation and Operating instructions for C / Fanless Control Cabinet Industrial PC. Version: 1.0 Date:

Installation and Operating instructions for. Control Cabinet PC C6240 from Version: 2.0 Date:

Installation and Operating instructions for Industrial PC series C61xx up to Version: 2.6 Date:

Installation and Operating instructions for. Control Cabinet PC C6250 up to Version: 1.6 Date:

Installation and Operating instructions for CP78xx Control Panel. Version: 1.8 Date:

Description AX5805. List of permissible motors. Version: Date:

Installation- and Operating instructions for. Build-in Industrial PCs C3620, C3640 from Version: 3.0 Date:

KL6001 Serial interface RS 232 C Configuration Instructions. Version

Installation and Operating instructions for. CP79xx Control Panel. Version: 1.2 Date:

Installation and Operating instructions for 19 Inch Rack Mount Industrial PC C5102 from -0060

Installation and Operating instructions for. CP79xx Control Panel. Version: 1.5 Date:

19-inch slide-in Industrial PC C5210

Installation and Operating instructions for. Built-in Control Panel CP68xx. Version: 2.0 Date:

Manual CX Audio interface for CX20x0. Version: Date:

Installation and Operating instructions for. Panel-PC CP71xx. Version: 1.4 Date:

CP39xx-0010 Multi-touch Control Panel with CP-Link 4 interface

Application Note FC1100/FC1121 (EtherCAT Slave Card)

Installation and Operating instructions for. CP790x-140x. IP65 Stainless Control Panel. Version: 1.1 Date:

CP29xx-0010 Multi-touch Control Panel with CP-Link 4 interface

Operating manual ELX9012, ELX9410, ELX9560. ELX System Terminals. Version: Date:

INSTRUCTION MANUAL WCS-Interface Module, DeviceNet

Documentation. AL225x Connector-Box. Accessory for servo drives of the series AX5000 and AX2000. Version: Date:

Installation and Operating instructions for CP / CP Economy Built-in Panel PC. Version: 1.

Serial PROFIBUS Interface

Control Cabinet Industrial PC C6640/ C6650 up to -0030

Installation and Operating instructions for. Control Cabinet Industrial PC C from Version: 2.0 Date:

CPCI-PS24 24V-Power Supply

Description AX5805. Default values for the permissible motors. Version: Date:

Installation and Operating instructions for. CP27xx. Fanless multi-touch built-in Panel PC. Version: 1.0 Date:

Documentation for. TwinSAFE User. Tool to modify the User Administration of a TwinSAFE Logic. Version: Date:

HEC. General Operating, Maintenance and Installation Manual

Installation and Operating instructions for Build-in Industrial PC C33xx up to -0050

Application Note FC1100/FC1121 (EtherCAT Slave Card)

PHOENIX CONTACT - 05/2007

Installation and Operating instructions for CP / CP Economy Built-in Panel PC. Version: 1.

CAN Repeater CAN-CR200, CAN-CR220, CAN-CR210/FO

Installation and Operating instructions for Control Panel CP77xx. Version: 1.6 Date:

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Installation and Operating instructions for. C inch slide-in Industrial PC. Version: 1.0 Date:

EDG Port Industrial 10/100 Mbps Ethernet Switch. User Manual

Hardware Manual RM CANview

Documentation. KL2784 und KL2794. Four channel digital output terminals with MOSFET transistors. Version: Date:

Installation and Operating instructions for. Built-in Panel PC CP63xx. Version: 1.4 Date:

PHOENIX CONTACT - 07/2006

Industrial Ethernet Switch

CompactFlash TM Card

Operating and mounting instructions

Installation and Operating instructions for. Economy built-in Panel PC CP62x9. Version: 1.0 Date:

Installation and Maintenance

Installation and Operating instructions for. CP69xx. Built-in Control Panel with DVI/ USB Extended interface. Version: 2.

CompactFlash TM Card

Redundancy unit CP-A RU

CAN Repeater CAN-CR200, CAN-CR220, CAN-CR210/FO USER MANUAL ENGLISH

_A_EN i Doc:

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

CP 1623 SIMATIC NET. PG/PC - Industrial Ethernet CP Preface. Description of the device. Software installation. Hardware installation

HARDWARE MANUAL ENGLISH

Installation and Operating instructions for. CP37xx. Multi-touch Panel PC. Version: 1.2 Date:

Electronic Temperature Controller. Instruction Manual Version

USER MANUAL en-us ENGLISH

PNOZ m ES RS232. Configurable Control System PNOZmulti. Operating Manual EN-01

Installation and Operating instructions for. CP32xx. Multi-touch Panel PC. Version: 1.7 Date:

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

QuickPanel View & QuickPanel Control

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

Transcription:

CU8870-0000 Compact-Flash card adapter for USB Version: 1.0 Date: 2007-06-15

Table of Contents Table of Contents 1 Foreword 1 1.1 Notes on the documentation 1 1.1.1 Liability Conditions 1 1.1.2 Conditions of delivery 1 1.1.3 Copyright 1 1.2 Safety Instructions 2 1.2.1 State at Delivery 2 1.2.2 Description of safety symbols 2 2 Product Overview 3 2.1 Introduction 3 2.2 Technical Data 4 2.3 Dimensions 5 3 Installation 6 3.1 Mounting / Unmounting 6 3.2 Power Supply 7 3.2.1 Power consumption 7 3.2.2 UL requirements 7 3.3 Compact-Flash card 8 3.3.1 Inserting the CF card 8 3.3.2 Ejecting the CF card 8 3.4 Connectors 9 3.5 LED-Diagnosis 10 3.6 Connection to Host 11 4 Approvals for USA and Canada 12 4.1 FCC Approval for USA 12 4.2 FCC Approval for Canada 12 5 Appendix 13 5.1 Beckhoff support and service 13 5.1.1 Beckhoff support 13 5.1.2 Beckhoff service 13 5.2 Beckhoff headquarters 13 CU8800-0000

Foreword 1 Foreword 1.1 Notes on the documentation This description is only intended for the use of trained specialists in control and automation engineering who are familiar with the applicable national standards. It is essential that the following notes and explanations are followed when installing and commissioning these components. 1.1.1 Liability Conditions The responsible staff must ensure that the application or use of the products described satisfy all the requirements for safety, including all the relevant laws, regulations, guidelines and standards. The documentation has been prepared with care. The products described are, however, constantly under development. For that reason the documentation is not in every case checked for consistency with performance data, standards or other characteristics. None of the statements of this manual represents a guarantee (Garantie) in the meaning of 443 BGB of the German Civil Code or a statement about the contractually expected fitness for a particular purpose in the meaning of 434 par. 1 sentence 1 BGB. In the event that it contains technical or editorial errors, we retain the right to make alterations at any time and without warning. No claims for the modification of products that have already been supplied may be made on the basis of the data, diagrams and descriptions in this documentation. 1.1.2 Conditions of delivery Furthermore the general conditions of delivery of company Beckhoff Automation GmbH apply. 1.1.3 Copyright This documentation is copyrighted. Any reproduction or third party use of this publication, whether in whole or in part, without the written permission of Beckhoff Automation GmbH, is forbidden. CU8870-0000 1

Foreword 1.2 Safety Instructions 1.2.1 State at Delivery All the components are supplied in particular hardware and software configurations appropriate for the application. Modifications to hardware or software configurations other than those described in the documentation are not permitted, and nullify the liability of Beckhoff Automation GmbH. 1.2.2 Description of safety symbols The following safety symbols are used in this operating manual. They are intended to alert the reader to the associated safety instructions. Danger This symbol is intended to highlight risks for the life or health of personnel. Warning This symbol is intended to highlight risks for equipment, materials or the environment. Note This symbol indicates information that contributes to better understanding. CU8870-0000 2

Product Overview 2 Product Overview 2.1 Introduction CU8870 is the Beckhoff CF card adapter for USB for DIN rail.the CF card can be used in industrial environment as process and control data storage. Any control with a USB port can be supplied with a CF storage. The device can be easiely mounted on the DIN rail.other outstanding features are: User-friendly installation via integrated DIN rail adapter No power supply needed the box is supplied by USB (5V DC) 12 Mbit, and 480 Mbit support for compatibility to USB1.1 and USB 2.0 standard Standard USB cable for data exchange compact industrial design CU8870-0000 3

Product Overview 2.2 Technical Data Product name CU8870-0000 Number of USB type B ports (upstream) 1 Number of CF cards slots 1 Supported standard USB 1.1, USB 2.0 Supported baud rates 12 Mbit/s, 480 Mbit/s Status display 3 LEDs USB wiring length maximum 5 meters Current consumption from 5 V USB maximum 500mA @ 5V DC (for details see chapter power supply) Dimensions (w x h x d) app. 34mm x 100mm x 76mm (with lug for mounting rail release) Weight app. 95 g Permissible ambient temperature 0 C to +55 C (operation) -25 C to +70 C (transport/storage) Permissible relative humidity 5% to 95%, no condensation EMC resistance burst / ESD EN 60000-6-2 / EN 60000-6-4 Vibration / Shock resistance EN 60068-2-6 / EN 60068-2-27, EN 60068-2-29 Assembly on 35 mm mounting rail conforms to EN 50022 Installation position Any Protection class IP20 Approvals CE UL (see chapter UL requirements) CU8870-0000 4

Product Overview 2.3 Dimensions The product is characterized by small overall installed size. With a height of 100 mm, the module dimensions exactly match those of the Beckhoff Bus Terminals. Together with the lowered connector surfaces, this means that it can be used in a standard terminal box with a height of 120 mm. CU8870-0000 5

Installation 3 Installation 3.1 Mounting / Unmounting The USB-Extender-Tx CU8870-0000 can be snapped onto a 35 mm mounting rail conforms to EN 50022. To release the CU8870-0000 from the mounting rail first pull the lug at the bottom of the hub downwards by using a screw driver (1.) then pull the hub from the mounting rail (2.) CU8870-0000 6

Installation 3.2 Power Supply The CF card reader does not need any additional power supply. The power supply (5 V DC) is realized by the USB connector. The LED P10 lights green when power supply is connected. 3.2.1 Power consumption The power consumption of the device depends on the CF media plugged in the reader. The table shows the values. media state current consumption power consumption None Standby 2 ma 10 mw CF card Idle 1 ma 5 mw CF card Access 20 ma 100 mw 3.2.2 UL requirements Danger To meet the UL requirements, the USB hub CU8800-0000 must not be connected to unlimited power sources! CU8870-0000 7

Installation 3.3 Compact-Flash card The Compact Flash card (CF card) is a non-volatile memory media. Data to be retained in the event of a power failure should be saved on the CF card. The CF card operates similar to a hard disk. Note It is recommended only use CF cards that are made for industrial use. (The cards can be ordered via Beckhoff Automation GmbH.) They possess a higher number of read / write cycles and an enhance temperature range (up to + 85 C). A proper operation of the device can only be guaranteed with the use of CF cards from Beckhoff Automation GmbH! 3.3.1 Inserting the CF card The CF card must be inserted carefully upright with the written side to the left. in the CF slot. The slot has a protection to ensure the right inserting direction. The card can only be inserted wrong direction with violence. As soon as the card is inserted, the LED (P20) lights up green. The red LED (P21) flashes up shortly, too. 3.3.2 Ejecting the CF card For ejecting the CF card press the small button below the CF slot. By pressing the button once the button expands. Pressing the button the second time the CF card ejects. The button engages again. The green LED (P20) extinguishes. CU8870-0000 8

Installation 3.4 Connectors The connectors are 1 USB port Type B connector and a cf card slot. The pins are described below: USB type B Port (X10) (standard cable) Pin Assignment 1 VCC 2 Data - 3 Data + 4 GND Shell Shield CF card slot (X20) (standard CF interface) Pin Signal Function Pin Type In, Out Type Pin Signal Function Pin Type In, Out Type Pin Signal Function Pin Type In, Out Type 1 GND - Ground 18 A02 I I1Z 35 -IOWR I I3U 2 D03 I/O I1Z,0Z3 19 A01 I I1Z 36 -WE I I3U 3 D04 I/O I1Z,0Z3 20 A00 I I1Z 37 Ready O OT1 4 D04 I/O I1Z,0Z3 21 D00 I/O I1Z,OZ3 38 Vcc - Power 5 D06 I/O I1Z,0Z3 22 D01 I/O I1Z,OZ3 39 -CSEL I I2Z 6 D07 I/O I1Z,0Z3 23 D02 I/O I1Z,OZ3 40 -VS2 O Open 7 -CE1 I I3U 24 WP O OT3 41 RESET I I2Z 8 A10 I I1Z 25 -CD2 O Ground 42 -WAIT O OT1 9 -OE I I3U 26 -CD1 O Ground 43 -INPACK O OT1 10 A09 I I1Z 27 D11 I/O I1Z,OZ3 44 -REG I I3U 11 A08 I I1Z 28 D12 I/O I1Z,OZ3 45 BVD2 O OT1 12 A07 I I1Z 29 D13 I/O I1Z,OZ3 46 BVD1 O OT1 13 Vcc - Power 30 D14 I/O I1Z,OZ3 47 DO8 I/O I1Z,OZ3 14 A06 I I1Z 31 D15 I/O I1Z,OZ3 48 DO9 I/O I1Z,OZ3 15 A05 I I1Z 32 -CE2 I I3U 49 D10 I/O I1Z,OZ3 16 A04 I I1Z 33 -VS1 O Ground 50 GND - Ground 17 A03 I I1Z 34 -IORD I I3U CU8870-0000 9

Installation 3.5 LED-Diagnosis LED Mapping Status Meaning P10 Power supply off no power supply connected (see chapter power supply for details) lights green Device is operational P20 CF LOCK off no CF card inserted lights green CF-card is inserted and electrical connected P21 ACCESS off no access on the media flashes Read / write access on the media CU8870-0000 10

Installation 3.6 Connection to Host The CF card reader is connected to a USB host via a standard USB cable. The maximum length for the wire is 5 meters. For correct operation, use USB 2.0 suitable wire. CU8870-0000 11

Approvals for USA and Canada 4 Approvals for USA and Canada 4.1 FCC Approval for USA FCC: Federal Communications Commission Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. 4.2 FCC Approval for Canada FCC: Canadian Notice This equipment does not exceed the Class A limits for radiated emissions as described in the Radio Interference Regulations of the Canadian Department of Communications. CU8870-0000 12

Appendix 5 Appendix 5.1 Beckhoff support and service Beckhoff and their partners around the world offer comprehensive support and service, making available fast and competent assistance with all questions related to BECKHOFF products and system solutions. 5.1.1 Beckhoff support Support offers you comprehensive technical assistance, helping you no only with the application of individual Beckhoff products, but also with other, wide-ranging services: world-wide support design, programming and commissioning of complex automation systems and extensive training program for Beckhoff system components Hotline: + 49 (0) 5246/963-157 Fax: + 49 (0) 5246/963-9157 e-mail: support@beckhoff.com 5.1.2 Beckhoff service The Beckhoff Service Center supports you in all matters of after-sales service: on-site service repair service spare parts service hotline service Hotline: + 49 (0) 5246/963-460 Fax: + 49 (0) 5246/963-479 e-mail: service@beckhoff.com You will find further support and service addresses on our internet pages under http://www.beckhoff.com. 5.2 Beckhoff headquarters Beckhoff Automation GmbH Eiserstr. 5 33415 Verl Germany Phone: + 49 (0) 5246/963-0 Fax: + 49 (0) 5246/963-198 e-mail: info@beckhoff.de Web: www.beckhoff.com The addresses of Beckhoff s branch offices and representatives round the world can be found on her internet pages: http://www.beckhoff.com. You will also find further documentation for Beckhoff components there. CU8870-0000 13