09LD/GD. Air-Cooled Condensers/Air-Cooled Fluid Coolers. Nominal cooling capacity kw 09LD/GD 09GD

Similar documents
kyalfa V- VDD/VDD6 General Contents

Chiller. CG 010 to 130. Remote Air Cooled Condensers Engineering Data Manual. 9.4 to 131 kw

NEOSTAR AXIAL FAN CONDENSER COMMERCIAL AND INDUSTRIAL RANGE HFC. 18 > 1240 kw. NEOSTAR POWER The choice of performance and low space requirement.

Kirby NK Heavy Commercial Industrial Unit Cooler. Natural fluids: Glycol water

MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH

MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH

MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH

Motivair MLC-SC Air-Cooled Scroll Chillers Tons

AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS

AIR COOLED CONDENSERS

Filter Fan Unit LIGHT

AIR COOLED HEAT PUMPS WITH SCREW COMPRESSORS AND AXIAL FANS

Technical Concept. Filter Fan Unit LIGHT. Type LIGHT AC Type LIGHT EC

FPS SERIES Super Slim Ceiling Mount Air Handling Units

BDD/BDD6 - Double Fan Row

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

InPac 600 Series Fully configurable severe duty and explosion proof HVAC and building pressurization systems 2 5 ton ::

1.5 to 5 Tons INDOOR COILS CH35. Horizontal PRODUCT SPECIFICATIONS CH A - 2 F MODEL NUMBER IDENTIFICATION FEATURES

Datasheet.

Specification. Radiamatic Detectors and Accessories

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

U-Match Series DC Inverter Service Manual PRODUCT

glide glider kw R134a air cooled liquid chillers AND free cooling chillers FREE COOLING SHELL A C CLASS E C Energy Class RCGROUP SpA

DDDM 45 (40-60 TPH) DDDM 60 ( TPH) COLD AGGREGATE FEEDER. Auxiliary belt No. of bins. Gathering conveyor reduction gear

Model KMF 720 Constant climate chambers with expanded temperature / humidity range

Slim Ducted type. Contents MMD-AP 4SPH2UL MMD-AP0094SPH2UL MMD-AP0124SPH2UL MMD-AP0154SPH2UL MMD-AP0184SPH2UL

MPC Air-Cooled Chillers MPC-FC Free-Cooling Chillers

Level sensor Stainless steel version Model RLT-1000, for industrial applications

IBIS. Duct diffuser with discs for supply air QUICK FACTS

Telescopic Masts STV Vehicle Adapters

SCADAPack Modbus multivariable transmitter

HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Min. Circuit Ampacity

RACO-ELECTRIC CYLINDER MODULAR SYSTEM HEAVY DUTY SERIES (TYPE 1) SIZE 4,5,6,7,8

C-Flow Coriolis Mass Flow Meter

Model KBW 720 Growth chambers with light

Sealed Enclosure Cooling Air Conditioners

InBin-P Pressure switches from 5 Pa Pa

Model KB 240 Cooling incubators with compressor technology

Immersion Temperature Sensors

UPGRADE PROGRAM. V250 Series Pumps vs V301 Series Pumps. Technical Memo

Next Generation Critical Cooling for Room and Row. Liebert PEX Efficiency And Reliability For High Availability Cooling. Condenser User Manual

Blue e+ chillers with the principle

Hoshizaki America, Inc.

07. har-link Interface Connectors

Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers

Flow VA 500/

Pressure switches and thermostats, types KP and KPI

Pressure controls, Type KP

Screw-in resistance thermometers with terminal head Form B

Tél. +41 (0) CH la Chaux-de-Fonds Case postale 2320

CTXA-AS/AT/AW, FTXA-AS/AT/AW

Electronic pressure switch with display Model PSD-4

Brasch Washdown Unit Heaters

Pressure switch Type KP

PROLINE ExtERNal ComPONENts. PROLINE tops and Bases

DIMENSION/WEIGHT kpa. 0 to 20 m / 0 to 60 ft 0 to 2 bar / 0 to 29 psi. 0 to 50 m / 0 to 160 ft 0 to 5 bar / 0 to 72.5 psi

42C/V. Fan Coil Unit Air Flow: 340~2040m 3 /h

Model KB 400 Cooling incubators with compressor technology

The CLIPPER Solutions

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw

07. har-link Interface Connectors

High Voltage Induction Motors. 21-MII Series. New High Efficiency Design for High Capacity Applications Up to 3,550 kw (4,750 HP)

WEIGHING PLATFORMS. Trade, commerce and industry. Product Numbers 2816, 2817, 2818, 2822

1.5 to 5 Tons INDOOR COILS CX35. Upflow - Cased - R-410A PRODUCT SPECIFICATIONS C X A - 6 F MODEL NUMBER IDENTIFICATION FEATURES

GP SERIES Packaged Chillers

ROLLING COUNTER SHUTTERS

Wiring Diagrams INDEX. UNIT DESCRIPTION DRAWING NUMBER FIG. NO. 09DK Field Wiring 09DK DK054,064

Pressure switch KP. Data sheet

Pressure switch KP. Data sheet

8 Submersible Motors Standard

HIGH EFFICIENCY 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R-410A REFRIGERANT

DESIGNED FOR THE FUTURE A NEW CONCEPT IN HATCH VENTILATION SYSTEMS

Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

MLC Air-Cooled Chillers MLC-FC Free-Cooling Chillers MLC-AD Adiabatic Chillers

Specification and Design Catalog. Waterside Economizer

Pressure switch KP. Data sheet

TH240g+Ko TH240g+Ko Pneumatic vise grip TH240g+2Ko Pneumatic vise grip TH240g + Ko TH240g + 2Ko Ordering information

SYSTEM 25 SYSTEM 50 AS SYSTEM 63 SYSTEM 75 SYSTEM 100. Alsident System 50. Antistatic (AS) Product Information

Ci7-SUB Manual (2.1 EN)

Model KB 400 Cooling incubators with compressor technology

in widespread use with Simplex sister Company, Simplex Onsite, providing nationwide load bank rentals.

CHAPTER 1. Unit CHA/IK/WP CHA/CLK CHA/ML/ST CHA/ML/ST CHA/ML/ST 182-P 302-P 50-51

Technical Concept. Filter Fan Unit RETURN AIR. Type RA-AC Type RA-EC

PC100 - Concept. Advantages in comparison

HERZ STRÖMAX GM/GML/GR STRÖMAX-GM/GML Circuit Control Valve with test points STRÖMAX-GR Circuit Control Valve Data sheet STRÖMAX GM/GML/GR, Issue 0215

Model VD 23 Vacuum drying chambers for non-flammable solvents

Accessories for control enclosures. BERNSTEIN attachment solutions. Double coupling head (console version with suspension system attachment)

Aquaflair. BREC & BREF kW 380V/3ph/60Hz - 460V/3ph/60Hz. Air-cooled chillers and free-cooling chillers with double screw compressors

Close-coupled centrifugal pumps

EC centrifugal module - RadiPac

IBISTM. Duct diffuser with discs for supply air

Series A19A/A19B/A19D. Thermostats for Refrigeration, Cooling, Heating, Ventilation and Air-conditioning. Feature and Benefits

1.5 to 5 Tons INDOOR COILS C35. Upflow - Cased and Uncased PRODUCT SPECIFICATIONS C A - 2 F - 1 MODEL NUMBER IDENTIFICATION FEATURES

Catalogue 2016 HOSE TECHNOLOGY. Fittings, Valves and Accessories. Schauenburg Hose Technology Group

DIRECT DRIVE VANEAXIAL FIXED PITCH FANS

Connector System for Circular Contacts

Electric Motors. IE2 Motors Industrial. hoyermotors.com. IE2 Motors. GREEN responsibility

Beam Position Monitor For High Energy Particle Beams

BW-108. Building Wash BW-108. User Guide. Advanced LED Technology

97105 NAMUR, 3/2, 5/2 & 5/3 Indirect electromagnetic actuated spool valves

Transcription:

Air-Cooled Condensers/Air-Cooled Fluid Coolers 09LD/GD 09GD 09LD/GD Nominal cooling capacity 281-987 kw The 09LD air-cooled condensers are designed for refrigeration plants where a halogenated hydrocarbon, such as R-22, R-502 etc. is used as the refrigerant. The 09GD fluid coolers are designed for cooling water or any fluid that does not corrode copper. The only difference from the 09LD condensers is in the physical data. The low-speed, low-noise versions of both unit types are particularly suited to sensitive applications, for example hospitals and offices. Features n Wide product range, based on modular principle - 38 different models in both horizontal and vertical units - for the most economic solution in each application n Several sound level classes and energy saving options n Low sound levels and high efficiencies. n Inherent reliability - the sturdy, corrosion-resistant construction, direct-drive fans, service doors and heat exchanger that is not prone to fouling ensure easy maintenance and a long service life. n Modular principle and motors built to IEC-standards. n Small internal volumes for reduced refrigerant charges. n Compact units, suitable for standard transport methods for reduced freight costs. n Factory-fitted safety switches on end-plates, vent points and lifting lugs reduce installation costs. 1

Standard models Heat exchanger The heat exchanger is the efficient Carrier F5 finned coil made of copper tubes and aluminium fins. Fin spacing is 2.5 mm. The fin collars cover the entire outside surface of the tubes. The close tube spacing and the specially corrugated fins make the heat exchanger extremely efficient. The fins are compact, without dirt accumulating cut edge turbulators. Headers are made of copper or of painted steel. Standard tube connections are made of copper, for larger sizes they are also available in steel. Headers are provided with plugged nipples for venting. If required, the heat exchanger can be divided into several circuits. Fans The direct-drive axial fans are statically and dynamically balanced. The low sound level has been achieved through the combination of high efficiency, aerodynamic construction, adequate vibration damping and low fan speeds. The motors are totally enclosed, squirrel-cage motors, built to IEC-standards for outdoor use. Protection class IP54, except for the condensation drains. The motors are prewired to lockable safety switches (IP55) on the end plates of the condensers. Locks are not included. Casing All parts are made of stainless or corrosion-protected material. The casing, legs, fan brackets, bolts and lifting eyes are made of hot-dip galvanized steel. The fan guards are made of plastic-coated steel. Correction factors for 3.0 and 4.0 mm fin spacing Fin spacing Condenser capacity mm Speed 16 12 10 8 6 3.0 0.99 0.98 0.97 0.96 0.94 4.0 0.93 0.91 0.90 0.88 0.86 Fin spacing Air flow Surface mm Speed 16 12 10 8 6 area factor 3.0 1.06 1.06 1.05 1.05 1.04 0.84 4.0 1.11 1.10 1.10 1.09 1.08 0.65 Fans For 60 Hz supplies, the condenser motors and unit performance will change. Please contact Carrier for further information. Accessories Safety switches (Option Q) Safety switches are installed adjacent to the fans. Spray system (option N ) The condensers can be equipped with a water spray system (option N), which considerably increases the condensing capacity during periods of high ambients. Junction boxes (alternative) The fan safety switches can be replaced by junction boxes, protection class IP55. Condenser selection The notes on the next page can be used to determine the capacity for a temperature difference other than the nominal 15 K. Capacity control Partitions are provided between the fans for effective control of the head pressure by fan cycling. In standard models the partitions are mounted transversely and are equipped with service doors. Optional equipment Heat exchanger n For conditions requiring special corrosion protection the coil can be surface-treated, or special materials can be used: - chromated fins - fins of epoxy- or vinyl-coated aluminium (condenser capacity reduced by 7% compared with standard model) - copper fins - tinned copper fins - tinned copper tubes and fins (only in sizes 12-18) - 3.0 or 4.0 mm fin spacing is available to special order. 2

Product Designation Standard model: 09LDE - 38-2-09-8-9H D Design series 38 Size 2 Number of fans 09 Fan diameter 8 Fan speed 6 = 15.0 r/s - 8 = 11.7 r/s 10 = 8.3 r/s - 12 = 7.5 r/s 16 = 5.8 r/s 9 Power supply 8 = 230 V, 3 ph, 50 Hz / 9 = 400 V, 3 ph, 50 Hz H/V Horizontal air flow/vertical air flow Additional marking (if necessary): J-10:10-N-Q J Multiple circuits 10:10 Multi-circuit section N Nozzles for water spray Q Safety switches Non-standard model: 09GDE - 38-2-09-8-9H-50 DN65 G Design series E Non standard model 38 Size 2 Number of fans 09 Fan diameter 8 Fan speed 6 = 15.0 r/s - 8 = 11.7 r/s 10 = 8.3 r/s - 12 = 7.5 r/s 16 = 5.8 r/s 9 Power supply 8 = 230 V, 3 ph, 50 Hz / 9 = 400 V, 3 ph, 50 Hz H/V Horizontal air flow/vertical air flow 50 Number of passes DN Type of pipe connections DN = flange R= outside thread 80 Pipe connection size Additional marking (if necessary): J-10:10-N-Q J Multiple circuits 10:10 Multi-circuit section N Nozzles for water spray Q Safety switches Selection tables Fan speed designation 1) 16 12 10 8 6 Fan 2) 914-L 914-L 914-L 914-L 914-L Speed 5.8 r/s 7.5 r/s 8.3 r/s 11.7 r/s 15.0 r/s Motors 0.14 kw - 1.3 A 0.37 kw - 2.8 A 0.55 kw - 3.4 A 1.2 kw - 5.0A 2.5 kw - 6.3 A Size CAP 3) Flow SPL 1) CAP 3) Flow SPL 1) CAP 3) Flow SPL 1) CAP 3) Flow SPL 1) CAP 3) Flow SPL 1) 09LD-140-8 09 281 20.0 42 356 27.5 53 408 33.3 56 484 43.3 61 583 58.8 69 09LD-150-8 09 308 21.6 43 388 29.4 54 443 35.4 57 528 46.0 63 635 62.2 70 09LD-160-8 09 324 22.4 44 412 30.6 55 471 36.8 58 561 47.6 63 679 64.4 71 09LD-170-10 09 351 25.0 42 446 34.4 54 510 41.6 57 606 54.2 62 729 73.5 70 09LD-190-10 09 385 27.0 44 485 36.6 55 554 44.6 58 660 57.6 63 794 77.8 71 09LD-200-10 09 406 28.0 45 515 38.2 56 589 46.0 59 702 59.6 64 849 80.5 72 09LD-210-10 09 524 34.5 54 610 41.7 57 749 54.3 62 931 73.6 70 09LD-220-10 09 542 34.5 54 636 41.7 57 787 54.3 62 987 73.6 70 CAP - Condenser capacity, kw Flow - Condenser air flow, m 3 /s SPL - Sound pressure level, db(a) 1) Sound pressure level at a distance of 10 m from the middle point of the condenser in freefield conditions. 2) The figure given for the fan type indicates the diameter (mm) and the letter the pitch angle (L= low). The indicated motor data are nominal values. Power supply 380 V, 3 ph, 50 Hz, air temperature +40 C. The values may change for a change in motor type or rating. A ±20% provision for adjustment should therefore be made in the overcurrent protection. 3) Condenser capacity for temperature differences other than 15 K may be obtained by multiplying the nominal value by the correction factor Kn, shown below. All values are based on refrigerant R-22. t (K) 8 9 10 11 12 13 14 15 16 17 18 Kn 0.53 0.6 0.67 0.73 0.8 0.87 0.93 1.0 1.07 1.13 1.2 Standard tubing suitable for temperature differences from 12 to17 K. 3

Physical data (09LD condensers) Dimensions A-H and the dimensions in the drawings are in millimetres. Sound level class 16, 12, 10 09LD-140-8 09 4740 2360 1920 2260 1120 2x54 2x42 1261 200 1680 0.77 2x1 09LD-150-8 09 4740 2360 2130 2260 1120 2x54 2X42 1433 230 1780 0.77 2X1 09LD-160-8 09 4740 2360 2340 2260 1120 4x42 4x35 1605 253 1900 0.77 2x1 09LD-170-8 09 5860 2360 1920 2x1990 1120 2x63 2x54 1576 250 2090 0.96 2x1 09LD-190-8 09 5860 2360 2130 2x1990 1120 2x63 2x54 1791 285 2230 0.96 2x1 09LD-200-8 09 5860 2360 2340 2x1990 1120 4x42 4x35 2006 305 2350 0.96 2x1 09LD-210-8 09 5860 2360 2340 2x1990 1120 4x42 4x35 2508 370 2690 0.96 2x1 09LD-220-8 09 5860 2360 2340 2x1990 1120 4x42 4x35 3010 453 2790 0.96 2x1 Sound level class 8, 6 09LD-140-8 09 4740 2360 1920 2260 1120 2x63 2x54 1261 207 1770 0.77 2x1 09LD-150-8 09 4740 2360 2130 2260 1120 2x63 2x54 1433 236 1870 0.77 2x1 09LD-160-8 09 4740 2360 2340 2260 1120 4x54 4x42 1605 260 1985 0.77 2x1 09LD-170-8 09 5860 2360 1920 2x1990 1120 4x54 2x54 1576 244 2200 0.96 2x1 09LD-190-8 09 5860 2360 2130 2x1990 1120 4x54 2x54 1791 280 2335 0.96 2x1 09LD-200-8 09 5860 2360 2340 2x1990 1120 4x54 4x42 2006 312 2460 0.96 2x1 09LD-210-8 09 5860 2360 2340 2x1990 1120 4x63 4x54 2508 390 2800 0.96 2x1 09LD-220-8 09 5860 2360 2340 2x1990 1120 4x63 4x54 3010 460 2900 0.96 2x1 SA Surface area, m 2 IV Internal volume, l Weight Net weight, kg TC Tube connection R Flow Spray system water flow, m 3 /h 1) Finned coil F5, fin spacing 2,5 mm. 2) Weight of basic model comprising aluminium fins and aluminium casing. Approximate additional weights to table values (from smallest to largest size): packaging 25-30%, copper fins 35-45%, steel casing 20-25%. More accurate values provided on request 3) With 3,0 bar water pressure 4) Safety switches (or junction boxes) 5) Service doors 6) Tube connection for water nozzle system (D) 4

Physical data (09LD condensers) Dimensions A-H and the dimensions in the drawings are in millimetres. Sound level class 16, 12, 10 09LD-140-8 09 4740 2360 1920 2260 1120 2x54 2x42 1261 200 1680 0.77 2x1 09LD-150-8 09 4740 2360 2130 2260 1120 2x54 2X42 1433 230 1780 0.77 2X1 09LD-160-8 09 4740 2360 2340 2260 1120 4x42 4x35 1605 253 1900 0.77 2x1 09LD-170-8 09 5860 2360 1920 2x1990 1120 2x63 2x54 1576 250 2090 0.96 2x1 09LD-190-8 09 5860 2360 2130 2x1990 1120 2x63 2x54 1791 285 2230 0.96 2x1 09LD-200-8 09 5860 2360 2340 2x1990 1120 4x42 4x35 2006 305 2350 0.96 2x1 09LD-210-8 09 5860 2360 2340 2x1990 1120 4x42 4x35 2508 370 2690 0.96 2x1 09LD-220-8 09 5860 2360 2340 2x1990 1120 4x42 4x35 3010 453 2790 0.96 2x1 Sound level class 8, 6 09LD-140-8 09 4740 2360 1920 2260 1120 2x63 2x54 1261 207 1770 0.77 2x1 09LD-150-8 09 4740 2360 2130 2260 1120 2x63 2x54 1433 236 1870 0.77 2x1 09LD-160-8 09 4740 2360 2340 2260 1120 4x54 4x42 1605 260 1985 0.77 2x1 09LD-170-8 09 5860 2360 1920 2x1990 1120 4x54 2x54 1576 244 2200 0.96 2x1 09LD-190-8 09 5860 2360 2130 2x1990 1120 4x54 2x54 1791 280 2335 0.96 2x1 09LD-200-8 09 5860 2360 2340 2x1990 1120 4x54 4x42 2006 312 2460 0.96 2x1 09LD-210-8 09 5860 2360 2340 2x1990 1120 4x63 4x54 2508 390 2800 0.96 2x1 09LD-220-8 09 5860 2360 2340 2x1990 1120 4x63 4x54 3010 460 2900 0.96 2x1 SA Surface area, m 2 IV Internal volume, l Weight Net weight, kg TC Tube connection R Flow Spray system water flow, m 3 /h 1) Finned coil F5, fin spacing 2,5 mm. 2) Weight of basic model comprising aluminium fins and aluminium casing. Approximate additional weights to table values (from smallest to largest size): packaging 25-30%, copper fins 35-45%, steel casing 20-25%. More accurate values provided on request 3) With 3,0 bar water pressure 4) Safety switches (or junction boxes) 5) Service doors 6) Tube connection for water nozzle system (D) 4

Physical data (09GD fluid coolers) Dimensions A-F and the dimensions in the drawings are in millimetres. Fluid coolers Size A B C D F SA1) IV Weight 2) Flow 3) TC 09GD-140-8 09 4740 2360 1920 2260 1120 1261 207 1770 0.77 2x1 09GD-150-8 09 4740 2360 2130 2260 1120 1433 236 1870 0.77 2X1 09GD-160-8 09 4740 2360 2340 2260 1120 1605 260 1985 0.77 2x1 09GD-170-8 09 5860 2360 1920 2x1990 1120 1576 244 2200 0.96 2x1 09GD-190-8 09 5860 2360 2130 2x1990 1120 1791 280 2335 0.96 2x1 09GD-200-8 09 5860 2360 2340 2x1990 1120 2006 312 2460 0.96 2x1 09GD-210-8 09 5860 2360 2340 2x1990 1120 2508 390 2800 0.96 2x1 09GD-220-8 09 5860 2360 2340 2x1990 1120 3010 460 2900 0.96 2x1 SA Surface area, m 2 IV Internal volume, l Weight Net weight, kg TC Tube connection R Flow Spray system water flow, m 3 /h 1) Finned coil F5, fin spacing 2,5 mm. 2) Weight of basic model comprising aluminium fins and aluminium casing. Approximate additional weights to table values (from smallest to largest size): packaging 25-30%, copper fins 35-45%, steel casing 20-25%. More accurate values provided on request 3) With 3,0 bar water pressure 4) Safety switches (or junction boxes) 5) Service doors 6) Tube connection for water nozzle system (D) 5