/, 5/ & 5/ spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT or flanged with NAMUR interface For single and double operated actuators Exhaust air recirculation at way function Monostable valves for safety systems up to SIL (IEC 508) Crossover-free switching, switch-over function guaranteed Add-on manual override Suited for outdoor use under critical environment conditions (see solenoid list) The solenoid valves are applicable in the protection classes Ex emb, Ex dmb, Ex mb, Ex ia for zones & (gas), & (dust), ATEX cat. II GD International approvals: IEC Ex, FM, CSA others on request. DIN EN 508 IEC 508 bis SIL Approval depends on magnetic system, see page 5 and! Certificated valves and temperature ranges see valve table on page and Technical features Medium: Filtered, non-lubricated and dried compressed air, instrument air, nitrogen and other nonflammable neutral, dry fluids Operation: Indirect solenoid operated spool valves Mounting position: Optional, impuls valves preferably horizontally Orifice: DN mm, DN 8 mm Port size:: G /, / NPT, G /, / NPT, NAMUR-Flange Operating pressure:,5... 8 bar with internal air supply 0... 8 bar with external air supply, control pressure,5... 8 bar (by G/, / NPT or low power pilot system only) Fluid/Ambient temperature: Valve: -0... +5 C (NBR) -5... +80 C (HNBR) Depending on solenoid system Air supply must be dry enough to avoid ice formation at temperatures below C. installed in the open protect all connections against the penetration of moisture! Materials: Body: aluminium.05 with surface treatment for rough environmantal conditions (condensate test with alternating temperatures in sulphuric environment, salt spray test with different sodium chloride solutions, tested in ammonia environment), brass.00 (Ms 58) or stainless steel.0 ( L) Seals: NBR (special perbunan) or HNBR / N/en 5..5.0
Valves with seals NBR -0... +5 C *) Housing: aluminium anodized, (5), Actuation Operating pressure Flow *) Test certification IEC 508 *) Model *) G / Flange Solenoid/spring,5...8 00 x 0,5 0505 / NPT Flange Solenoid/spring,5...8 00 x 0,5 055 G / Flange Solenoid/spring,5...8 00 0,80 055 / NPT Flange Solenoid/spring,5...8 00 0,80 05 G / Flange Solenoid/solenoid,5...8 00 0,5 505 / NPT Flange Solenoid/solenoid,5...8 00 0,5 55 5 G / Flange Solenoid/solenoid (APB),5...8 50 0, 505 / NPT Flange Solenoid/solenoid (APB),5...8 50 0, 55 Housing: brass, (5), Actuation Operating pressure Flow *) Test certification IEC 508 *) Model *) G / Flange Solenoid/spring,5...8 00 x,00 005 / NPT Flange Solenoid/spring,5...8 00 x,00 05 G / Flange Solenoid/solenoid,5...8 00,0 05 / NPT Flange Solenoid/solenoid,5...8 00,0 5 5 G / Flange Solenoid/solenoid (APB),5...8 50,50 05 / NPT Flange Solenoid/solenoid (APB),5...8 50,50 5 Housing: stainless steel, (5), Actuation Operating pressure Flow *) Test certification IEC 508 *) Model *) G / Flange Solenoid/spring,5...8 00 x,00 005 / NPT Flange Solenoid/spring,5...8 00 x,00 05 G / Flange Solenoid/solenoid,5...8 00,0 05 / NPT Flange Solenoid/solenoid,5...8 00,0 5 G / Flange Solenoid/solenoid (APB),5...8 50,50 05 / NPT Flange Solenoid/solenoid (APB),5...8 50,50 5 5 *) When ordering please indicate solenoid, voltage and current Models (frequency) *) Since May 008, Date code A8 *) For operation in plants according to IEC 5/508-0... +0 C see test certificate (on request) *) Connecting pipe/fitting: In order to ensure and a pressure collapse avoid the flow, the supply air cross section should with ¼: 8 mm; with ½: 0 mm its. With smaller cross section the inlet should more largely, however at least equally large line at the port its. APB = All Blocked / or 5/ way function (Conversion instructions see page ) N/en 5..5.0 /
Valves with seals HNBR -5... +80 C *) Housing: aluminium anodized, (5), Actuation Operating pressure Flow *) Test certification IEC 508 *) Model *) G / Flange Solenoid/spring,5...8 00 x 0,5 005 / NPT Flange Solenoid/spring,5...8 00 x 0,5 05 G / Flange Solenoid/spring,5...8 00 x 0,80 05 / NPT Flange Solenoid/spring,5...8 00 x 0,80 0 G / Flange Solenoid/solenoid,5...8 00 0,5 05 / NPT Flange Solenoid/solenoid,5...8 00 0,5 5 5 G / Flange Solenoid/solenoid (APB),5...8 50 0, 05 / NPT Flange Solenoid/solenoid (APB),5...8 50 0, 5 Housing: aluminium anodized, Inlet filter and exhaust guard, (5), Actuation Operating pressure Flow *) Test certification IEC 508 *) Model *) G / Flange Solenoid/spring,5...8 00 x *) 0,5 8 00 5 5 G / Flange Solenoid/solenoid,5...8 00 0,5 0 5 5 Housing: brass, (5), Actuation Operating pressure Flow *) Test certification IEC 508 *) Model *) G / Flange Solenoid/spring,5...8 00 x,00 005 / NPT Flange Solenoid/spring,5...8 00 x,00 05 G / Flange Solenoid/solenoid,5...8 00,0 05 / NPT Flange Solenoid/solenoid,5...8 00,0 5 5 G / Flange Solenoid/solenoid (APB),5...8 50,50 05 / NPT Flange Solenoid/solenoid (APB),5...8 50,50 5 Housing: Stainless steel, (5), Actuation Operating pressure Flow *) Test certification IEC 508 *) Model *) G / Flange Solenoid/spring,5...8 00 x,00 005 / NPT Flange Solenoid/spring,5...8 00 x,00 05 5 G / Flange Solenoid/solenoid,5...8 00,0 05 / NPT Flange Solenoid/solenoid,5...8 00,0 5 G / Flange Solenoid/solenoid (APB),5...8 50,50 05 / NPT Flange Solenoid/solenoid (APB),5...8 50,50 5 *) When ordering please indicate solenoid, voltage and current Models (frequency) *) Since May 008, Date code A8 *) For operation in plants according to IEC 5/508-5 C...+5 C or 0...+80 C see test certificate (on request) *) Test certificate without inlet filter and exhaust guard *) Connecting pipe/fitting: In order to ensure and a pressure collapse avoid the flow, the supply air cross section should with ¼: 8 mm; with ½: 0 mm its. With smaller cross section the inlet should more largely, however at least equally large line at the port its. APB = All Blocked / or 5/ way function (Conversion instructions see page ) / N/en 5..5.0
Option selector... Function Substitute 5/ way with spring return 0 (/ way with adapter plate for NAMUR flange) 5/ way impuls (/ way with adapter plate for NAMUR flange) 5/ way with spring return (ABP) Material: Housing/seals Substitute Aluminium/HNBR (-5... + 80 C) Brass/HNBR (-5... + 80 C) Stainless steel/hnbr (-5... + 80 C) Aluminium/NBR (-0... + 5 C) 5 Brass/NBR (-0... + 5 C) Stainless steel/nbr (-0... + 5 C) Special design size Substitute G / 0 / NPT G / / NPT (in connection with version Number code ) APB = All Blocked Air supply Substitute Internal 0 External (only for G /, / NPT Z or low power pilot) Voltage Substitute V d.c. 0.0 0 V a.c. 0.5 Solenoid Substitute see solenoid table Version Substitute Without manual override (retrofit) 5 Semi automatic (on request) Low power pilot (see page 5) For / NPT + NAMUR (manual override retrofit) N/en 5..5.0 /
Solenoid operators Power consumption V d.c. 0 V a.c. (W) (VA) Rated current V d.c. 0 V a.c. (ma) (ma) Ex-Protection (ATEX- Categorie) Protection class *),, *5) 8 0 IP00 without connector *5) IP5 with connector *5), - 50 - IIG IID -, - 8 IIG IID 0,8 - - IIG IID -, - IIG IID 0,8 - - IIG IID 0,8 - - IIG IID -, - IIG IID -, - IIG IID Stainless steel 0,8 IIG IID, IIG IID Ex mb II T *) Ex td A IP T0 Ex mb II T *) Ex td A IP T0 Ex emb II T5/T Ex td A IP T0 *), *0) Ex emb II T5/T Ex td A IP T0 *), *0 Ex dmb IIC T5/T Ex emb II T5/T Ex td A IP T0 *) Ex dmb IIC T5/T Ex emb II T5/T Ex td A IP T0 *) Ex dmb IIC T5/T Ex emb II T5/T Ex td A IP T0 *) Ex dmb IIC T5/T Ex emb II T5/T Ex td A IP T0 *) Ex mb d IIC T/T Ex mb e II T/T Ex td A IP T00 *), *0) Ex mb d IIC T/T Ex mb e II T/T Ex td A IP T00 *), *0), - 5 - XP/DIP, Div. & Cl. I, Gr. A-D Cl. II / III, Gr. E-G T (0 C) *) NEMA, X,, P,, Standard voltages V d.c., 0 V a.c., other voltages on request. Design according to VDE 0580, EN 500/5008. 00% duty cycle. *) EG-Type-Examination-Certificate KEMA 0 ATEX X *) EG-Type-Examination-Certificate KEMA 8 ATEX 5 X *) EG-Type-Examination-Certificate PTB 0 ATEX 085 X *) CSA-LR 5-, FM Approvals *5) Required connector: type 0505 *) Connector cable gland not supplied, see table»accessories«*) IP-Protection class according to EN05 Solenoid actuators for intrinsically-safe circuits Temperature Ambient/ Fluid ( C) Electrical connection -5... +0 DIN EN 5 0-80 Form A Circuit diagram Model 0, /5 0 *) -0... +0 m Cable 0, 08 *8) -0... +0 m Cable 0, 0 *8) -0... +80 T5-0... +0 T -0... +80-0... +80 T5-0... +0 T -0... +80-0... +80 T5-0... +0 T -0... +80-0... +80 T5-0... +0 T -0... +80-0... +80 T5-0... +0 T -0... +80-0... +80 T5-0... +0 T -0... +80-0... +50 T -0... +0 T -0... +80-0... +50 T -0... +0 T -0... +80-0... +0 Flying leads 50 mm long M0 X,5 *) 0, 0 00 *8) M0 X,5 *) 0, 0 0 *8) / NPT *) 0,8 00 *8) M0 X,5 *) 0,8 0 *8) / NPT *) 0,8 0 *8) M0 X,5 *) 0,8 0 *8) M0 X,5 *), 80 *8), *) M0 X,5 *), 80 *8), *) 0, 8 0 Nominal Min. required Resistance Required Protection Temperature Circuit Model resistance RN coil (Ω) switching current (ma) Rw 0 coil (Ω) voltage at terminal Rw 0 (V) class Ambient/Fluid ( C) diagram 00 0 8 Ex ia IIC T -0... +0 0,85 0 050 0 Ex ia IIC T -0... +80 0,85 0 05 880 5 Ex iad T80 C -0... +0 0,85 0 05 0 0 Ex iad T00 C -0... +80 0,85 0 05 EG-Type-Examination-Certificate PTB 0 ATEX 0 (Kat. II GD) IECEx Certificate of Conformity IECEx PTB 0.00 Cable gland is included in delivery *8) Suitable for outdoor installation *0) IEC Ex Certificate of Conformity *) EG-Type-Examination-Certificate PTB 0 ATEX 05 X Attention: The protection class for coil series xx and 8xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex dmb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex emb. When selecting an intrinsically safe power supply, the permissible maximum values according to the Certificate of Conformity should be taken into acount. Ui = 5 V, Ii = 500 ma, according to Tab. A., EN 00- Pi =,0 W, Li and Ci can be ignored. / N/en 5..5.05
Valves, indirect solenoid actuated using low-power pilot system in protection class Ex ia IIC T/T, seals NBR -0... +5 C, (5), Actuation Material Operating pressure Flow *) Model *) G / Flange Solenoid/spring Aluminium,5...8 00 0,5 050 / NPT Flange Solenoid/spring Aluminium,5...8 00 0,5 05 G / Flange Solenoid/solenoid Aluminium,5...8 00 0,5 5 50 / NPT Flange Solenoid/solenoid Aluminium,5...8 00 0,5 5 5 5 G / Flange Solenoid/solenoid (APB) Aluminium,5...8 50 0, 50 / NPT Flange Solenoid/solenoid (APB) Aluminium,5...8 50 0, 5 Valves, indirect solenoid actuated using low-power pilot system in protection class Ex ia IIC T/T, seals HNBR -5... +80 C, (5), Actuation Material Operating pressure Flow *) Model *) G / Flange Solenoid/spring Aluminium,5...8 00 0,5 00 / NPT Flange Solenoid/spring Aluminium,5...8 00 0,5 0 5 G / Flange Solenoid/solenoid Aluminium,5...8 00 0,5 5 0 / NPT Flange Solenoid/solenoid Aluminium,5...8 00 0,5 5 G / Flange Solenoid/solenoid (APB) Aluminium,5...8 50 0, 0 / NPT Flange Solenoid/solenoid (APB) Aluminium,5...8 50 0, *) When ordering please indicate solenoid, voltage and electrical connection, see below *) Connecting pipe/fitting: In order to ensure and a pressure collapse avoid the flow, the supply air cross section should with ¼: 8 mm; with ½: 0 mm its. With smaller cross section the inlet should more largely, however at least equally large line at the port its. APB = All Blocked / or 5/ way function (Conversion instructions see page ) Low-power pilot system in protection class Ex ia IIC T/T Power P (+0 C) Switch-on voltage U on (+0 C) Switch-on voltage U on (+80 C) Switch-off voltage U off (+0 C) Switch-off voltage U off (-5 C) Rated current I on Resistance coil R (+0 C) Protection class Temperature Ambient Circuit diagram, mw, V 5, V, V, V,5 ma 800 Ω Ex ia IIC T -0 bis +80 C 085, mw V,8 V 5, V, V,5 ma 000 Ω Ex ia IIC T -0 bis +0 C 08 Model *) Max. values Ex i Ui (V) Ii (ma) Pi *5) (mw) 5 50 50 5 50 8 5 50 0 00 50 85 50 *) Category IIG, EG-Type-Examination-Certificate PTB 0 ATEX 00U Air consumption: home position 0 l/h, operating position 5 l/h *5) Model 08 without Pi limiting. Ci and Li can be ignored. *) Connecting pipe/fitting: In order to ensure and a pressure collapse avoid the flow, the supply air cross section should with ¼: 8 mm; with ½: 0 mm its. With smaller cross section the inlet should more largely, however at least equally large line at the port its. Ordering example 050. 085. 005. 00 Valve Pilot, mw Electrical connection 00 internal air supply 005 M x,5 cable gland 0Z external air supply N/en 5..5.0 /
Accessories Cable gland Protection class Ex e, Ex d (ATEX), Nickel plated brass/ stainless steel Connector Page Thread Cable Ø Material Protection class (ATEX) Model M 0x,5 5,0...8,0 mm Nickel plated brass IIGD Ex e 05888 M 0x,5 0... mm Nickel plated brass IIGD Ex d 058885 /--NPT,5..., mm Nickel plated brass IIGD Ex d 05885 M 0x,5,0... mm Stainless steel.5 ( Ti) IIGD Ex e 05885 M 0x,5,0... mm Stainless steel.0 ( L) IIGD Ex d 0585 M 0x,5 0... mm Stainless steel.0 ( L) IIGD Ex d 0588 0505 00 (with rectifier) Inlet filter Silencer *) Exhaust guard *) Manual override Manual override (for start-up only) Page Page Page Page Page 08 M/S (G/) 0 (G/, / NPT) 05588 (without detent) 0 (without detent) C/S (/ NPT) 0 (G/, / NPT) 05588 (with detent) M/S (G/) C/S (/ NPT) *) For indoors use only *) For outdoors use Throttle control plate Flange plate, for G/ only Yoke Distance plate for coils Mounting plate 0 and 0 Page 5 Page 5 Page 5 Page 5 Page 5 00 (only for G/) 00 (NAMUR single connection plate) 0505 0500 05 (0 ) 0 (NAMUR-rip use in combination with 00) 055 (0 ) / N/en 5..5.0
s Valves,5 5,5 0,5,5 5 8,5,5,5 5 5,, ~,5 5 5,, 5 ~,5 5,, 0,5 ~ 5/ 8,5,5,5,5 8,5 5/ 05,5 0,5,5,5 5/ 0 5,5 Solenoid optional turnable Port G / or / NPT NAMUR connection plate / or 5/ way function N/en 5..5.08 /
5,5,5,5,5,5,5 8,5 8,5 5/ 5/ 5 A 5 0 5 5 5, 5 5 5,5 5 0 External control pressure connection G/8 or /8 NPT Port G/ or / NPT Electrical connection selectable version 005 NAMUR connection plate / or 5/ way function Position of gasket internal pilot air 0 Position of gasket external pilot air C C Electrical connection 005 P ext. C-C P int. 0 / N/en 5..5.0
8,5,5,5 5/,5 0 5/ M 0 5 0 5 5 8 5 0 8 0,5 0,5 80,5 Solenoid optional turnable External control pressure connection G/8 or /8 NPT Port G/ or / NPT Electrical connection selectable version 005 NAMUR connection plate / or 5/ way function Position of gasket internal pilot air 0 Position of gasket external pilot air Port G/ or / NPT C C P ext. C-C P int. Electrical connection 005 0 N/en 5..5.0 /
8 0 5,5,5 5,, ~0 0 0,5,5,5 G/ M5 ~,5,5,5 ~0 Solenoid optional turnable NAMUR connection plate / or 5/ way function / N/en 5..5.
,5,5 5,, 0 0 0,5,5 0,5 G/ 0 0 ~0,5 5,5,5 M5 58,5,5 Solenoid optional turnable NAMUR connection plate / or 5/ way function N/en 5..5. /
s Solenoid operators 5,5 8,5 0,5 0 / - NPT 8 0,5 8 5,5 5,5,5 0,5 8,5 8 M x,5 8,5,5 0 0,5,5,5 0 M 0 x,5 5 5 8 0 Connector x 0 turnable Ø (with spacer tube) 5 M0 x,5 or / - NPT Flying leads 50 mm long 8 / N/en 5..5.
Circuit diagrams 5 0 NAMUR hole pattern (driving side) Port size G/ Port size G/ M5 5 M 0 5 5 Port (A) Coding stud threaded NAMUR quick exhaust module for a better kv-value by exhaust see data sheet 5..80 M5 & M (0 deep) 5 Port (R) Conversion instructions of 5/ into / way function 5/ way function (original mode of supply) / way function 5/ / / resp. 5/ way function according to version by swapping or turning enclosed adaptor plates. Make sure Marker and Arrow do match as shown on above drawing. Original mode of supply: 5/ function. Arrow Marker N/en 5..5. /
Single connection plate Model: 00 NAMUR slot Model: 0 5,5 M 5 (x),5 0 ø,5 0 5,5 0 G /,5 5 5,5 5,5 5,5 ø 5,5 G / 5 0 Yoke Model: 0505 ø ø,5 Throttle control plate Model: 00,5 5,5 x 5 50 5 M 5 5 0 8 5,5 M 5 5,5 B B 5,5 A A / N/en 5..5.5
0 Mounting plate Model: 05 0 Mounting plate Model: 055 Distance plate Model: 0500,5 5,5 5 58 0 0 50 M5 M5 0 0 M 5 55 55,5 55 55 Manual override Model: 05588 Model: 05588 Model: 0 0,5 M0 x 0,5 ~ M0 x 0,5 M0 x 0,5 ~ N/en 5..5. /
Silencer Model: M/S, M/S, C/S, C/S Exhaust guard Model: 0, 0 C C G G ø D B ø D B Model B G C Ø D (g) Model M/S, C/S / 5,5 5,5, 0 M/S, C/S /,5 0 B Suitable for G C Ø D (g) Model / G/, / NPT 0,5 5 0 / G/, / NPT,5 0 Inlet filter Model: 08 G/ G/,5 8,5 8,5 Cable gland C C B A D B A 05885 only D A B C ø D Model M0 x,5 5... 8 05888 M0 x,5,5,5... 05885 M0 x,5 0... 058885 /- NPT 5 58,5..., 05885 M0 x,5... 0585 M0 x,5 0 0... 0588 Warning These products are intended for use in industrial compressed air and fluid systems only. Do not use these products where pressures and temperatures can exceed those listed under»technical features«. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult NORGREN. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. / N/en 5..5.