Technical Datasheet #TDAXTC20 Thermocouple Scanner 20 Thermocouple Channels CAN, SAE J1939 with Electronic Assistant P/N: AXTC20 Description:

DAWN Mini ADAQ TC20 Details

Discrete I/O P/N: AXDIO inputs, 8 relay outputs, SAE J1939 with Electronic Assistant

Discrete I/O 12 Discrete Inputs 8 Relay Outputs CANopen P/N: AXDIO128CO

PRELIMINARY. Preliminary Technical Datasheet #TDAX Discrete I/O P/N: AX inputs, 8 relay outputs, SAE J1939 with Electronic Assistant

Applications: Power generator sets and control systems for industrial engine applications.

TECHNICAL DATASHEET #TDAX Analog Signal Output CAN Controller (SAE J1939)

TECHNICAL DATASHEET #TDAX I/O

Accessories: PL-DTM06-12SA-12SB Mating Plug Kit (1 DTM06-12S, DTM06-12SB, 2 W12S, 24 contacts) Electronic Assistant Configuration KIT: AX070502

Applications: Industrial Automation, Cranes, Hoists, Utility Vehicles, Off-highway, Ag, and Forestry Equipment

Applications: Industrial Automation, Cranes, Hoists, Utility Vehicles, Off-highway, Ag, and Forestry Equipment

P/N: AX Applications: power gen set engine control systems oil and gas equipment automation off-highway machine automation

Applications: Industrial Automation, Cranes, Hoists, Utility Vehicles, Off-highway, Ag, and Forestry Equipment

CONCEPT P/N: AX Concept TECHNICAL DATASHEET #TDAX Analog Input CAN Controller CAN (SAE J1939 or CANopen ) with Electronic Assistant

TECHNICAL DATASHEET #TDAX023240

TECHNICAL DATASHEET #TDAX023300

TECHNICAL DATASHEET #TDAX050000K CAN

Ordering Part Numbers: TECHNICAL DATASHEET #TDAX BLDC MOTOR CONTROLLER P/N: AX100260

P/N: AX Distribute your control functions directly onto the valve.

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL

Inclination sensors 2-dimensional, measuring range up to ±90

In addition to fan control, many other hydraulic control applications can be accommodated with this hardware and application-specific software.

TECHNICAL PRODUCT DATASHEET

Digital Indicator Solutions

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL

TM241CEC24R controller M IO relay Ethernet CAN master

Inclination sensors 1-dimensional, measuring range

CAN485. Wall Mounting CAN to RS-485 Interface Converter. Support data conversion between 1 CAN port and 1 RS-485 serial port

GW-7228 J1939/Modbus RTU Slave Gateway

Trident and Trident X2 Digital Process and Temperature Panel Meter

TM251MESC controller M251 Ethernet CAN

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

Two Module Development Kit Installation and User Instructions For Model No. ED-GV15/30

TM241C40U controller M IO transistor NPN

TM241C24T controller M IO transistor PNP

Modular pressure transmitters for harsh environments DST P500, DST P507 and DST P550

GW-7238D J1939 to Modbus TCP Server / RTU Slave Gateway

SPECIAL SPECIFICATION 6274 Microwave Vehicle Detection System

MasterFlux 48V Cascade BLDC Motor Controller Product Specification 030F0137

TM241C40R controller M IO relay

HelmView Model HV750; HVS750. Installation Manual Section 78

Manual# Installation Manual. 200E Series. DCU 210E/208E Engine Panel RP 210E/220E Remote Panel

This Datasheet for the IC660BBA104. Block 115Vac/125Vdc Analog Current Source 4 Inputs / 2 Outputs

TM241CEC24T. Main. 14 (remote I/O architecture) W with max number of I/O expansion module ma fast input. 2.

DTM Distributed Transmitter Monitor

Analog Input Module. ST-3xxx. User Manual CREVIS Co.,Ltd. Version FnIO S-Series

Blue ID Communication module RS485 SC44

Watts. xppower.com. General. Input. Output. Environmental. EMC & Safety. Compact Size. IT & Medical Approvals.

Analog Output Module. ST-4xxx. User Manual CREVIS Co.,Ltd. Version FnIO S-Series

FG series FIXED GRIP hand controllers

LENORD. +BAUER... automates motion. Tower oscillation monitor GEL 3011 for safety applications. Technical information Version General.

NX-series SSI Input Unit. Read position information from encoders with Synchronous Serial Interface (SSI). Features. System Configuration

PanelView Plus/VersaView CE Terminals and Display Modules

Device manual Inclination sensor 2 axes. JN2301 from firmware /00 05/2016

Industrial Power Supplies

TM241CE40R controller M IO relay Ethernet

System D I S T R I B U T E U R C O N S E I L D E P U I S vision sensors PRODUCT SPECIFICATIONS AND DRAWINGS

TM241CE24U controller M IO transistor NPN Ethernet

TM241CE24T controller M IO transistor PNP Ethernet

TM251MESC controller M251 Ethernet CAN

P3-SCM. General Specifications

INDUSTRIAL INCLINOMETER SAE J1939 INTERFACE

LAUREL ELECTRONICS, INC.

TECHNICAL PRODUCT DATASHEET

Industrial Power Supplies

TM7NCOM16A CANopen interface block - IP67-16 I/O - M12

TM241CE40R controller M IO relay Ethernet

FPS2800B12C4 Fluid Property Sensor Module

Thermometer T12. Precision Multichannel Thermometer System. Typical applications: REFLECTING YOUR STANDARDS

HelmView Model HV750. Installation Manual Section 78

User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX

MAJOR VA Power Inverter

TM241CE24T controller M IO transistor PNP Ethernet

3G/4G LTE Cellular to Ethernet and Serial Secure Industrial Gateway. SE5901B Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

This Datasheet for the IC660BBA026. Block 24/48Vdc Analog Current Source 6 Inputs.

SD328AU68S2 motion control stepper motor drive - SD328 - <= 6.8 A

TM241CE40T controller M IO transistor PNP Ethernet

P3-RS Remote Slave Module

TM241CE40R controller M IO relay Ethernet

Advantys ETB. DATA SHEET Advantys ETB IP 67 Ethernet Digital I/O Modules. Description. Features

Operating Instructions 12/2010 MN Z-EN XV-152 MICRO PANEL

The LSI Gateway. GS220, GS221, GS222 series - LSI gateways. Features:

COGNEX. Checker SensorView. Quick Reference Guide

Military (Airborne, ground-fix, shipboard), Ruggedized, Telecom, Industrial

Power Supplies GLX40 GLX50 GLX60 GLX110-B GLX110-C GLX120 GLX140-C GLX140-CF GLX150-C GLX17Q-C GLX17S-C GLX200 GLX250-CEF GLX250-CF

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) SUITABLE FOR EXTERNAL DISTRIBUTION

Fieldbus System. New. New. Series EX260 IP67. Drives up to 32 solenoids. Daisy-chain wiring communication. Compact 28mm

TM221CE40R controller M IO relay Ethernet

MSR 2400R. Rugged Power System for Military and Heavy Duty Applications

3G/4G LTE Cellular to Ethernet and Serial Secure Industrial Gateway. SE5901B Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

CompactBlock Guard I/O EtherNet/IP Safety Modules

Click Desktop Kit. Click Desktop Kit

DATA SHEET DEPRECATED - PCM5 1. Document no.: N/A

OBSOLETE. CanWorks itrax Two-Channel Control Unit Installation. Instruction Sheet P/N A

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

PD765 TRIDENT. Trident Series Process & Temperature Meters.

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

Ethernet to Digital I/O +RS232 +Switch

TM3AI4 module TM3-4 analog inputs

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

Transcription:

Technical Datasheet #TDAXRTD8 RTD Scanner 8 RTD Channels CAN, SAE J1939 with Electronic Assistant P/N: AXRTD8 Description: The RTD Scanner monitors 8 RTD inputs from a diesel engine and the temperature information is provided to the engine control system over a SAE J1939 CAN bus. Temperature information can include exhaust temperature, winding temperature, and fluid temperature monitoring. All channels of temperature data are automatically sent over the CAN bus when power is applied with no additional programming or configuration required. Integral diagnostics determine RTD integrity. RTD inputs are isolated from the CAN communication and power supply. During set-up, using an USB-CAN converter and a PC, the operator can configure the controller via the Electronic Assistant to suit a wide variety of applications. The RTD Scanner features rugged packaging and watertight Deutsch IPD connectors for an IP67 rating. The module is UL recognized for UL508 (FTPM2) Controls for Stationary Engine Driven Assemblies and has a cul recognition as well. The control carries a CE mark for the EMC and RoHS Directives. The AXRTD8 meets the environmental, EMC and vibration requirements of generator set applications in marine installations and has type approvals from several marine societies (LR, DNV, ABS, etc.). Applications: Stationary, portable power generator sets Genset control systems Ordering Part Numbers: RTD Module, SAE J1939 P/N: AXRTD8 A CANopen model is available under ordering P/N: AXRTD8CO. Electronic Assistant P/N: AX070502 Mating Plug Kit P/N: AX070200 This kit includes the following items. These items are also available from a local Deutsch IPD distributor. NB. The sealing plugs are only needed in cases where not all of the 40 pins are used. A crimping tool from Deutsch IPD is required to connect wiring to the sockets, P/N: HDT 48-00 or equivalent (not supplied). Deutsch IPD P/N: Description: 0462-201-16141 48 16AWG SOCKETS SOLID 16-20AWG WIRE 6mm 114017 24 SEALING PLUGS SIZE 12-16 CAVITIES 12-18 AWG DRC16-40S DT06-08SA W8S 40-PIN PLUG, No Key DT SERIES PLUG 8 CONTACT WEDGELOCK FOR DT 8 PIN PLUG Axiomatic Technologies Corporation 5915 Wallace Street, Mississauga, Ontario Canada L4Z 1Z8 TEL: (905) 602-9270 FAX: (905) 602-9279 E-mail: sales@axiomatic.com www.axiomatic.com

Block Diagram TDAXRTD8 2

Technical Specifications Inputs Power Supply Input Supply Current Protection RTD Types RTD Inputs Scan Rate Common Mode Readings Thermal Drift Isolation SPNs and PGNs 12V or 24VDC nominal (9 32 VDC power supply range) 50 or 60 Hz is user selectable. 200 ma at 12 V Typical 100 ma at 24 V Typical Inrush does not exceed 800 ma. Reverse polarity protection is provided. Power supply input section protects against transient surges and short circuits and is isolated from RTD inputs Up to 8 channels, independently configurable for 2, 3 or 4 wire RTDs. Each channel independently supports specific sensors IEC 0.00385, JIS 0.003916, US 0.003902, Legacy 0.003920, SAMA 0.003923. A user defined coefficient would enable custom Callendar-Van Dusen constants to be set for sensors not listed above. The device accepts inputs within the following range of 10-350 Ohms. Accuracy: +/- 1 C typical at ambient temperature Resolution: 0.001 C Isolation voltage is 1500 Vac (rms) or 2550V for 1 sec. 100ms per channel, total sweep time maximum 900 ms Input range +/- 4V maximum Rejection is 100db at 5Vp-p (50-60Hz) 150 ppm/ C of span (maximum) Digital isolation is 500VDC from input to ground. Three way isolation is provided for the CAN line, inputs and power supply The SPN drop list includes all temperature SPNs from the J1939-71 standard published up to January of 2009. If an SPN is not supported by the drop list, the user can select a zero SPN, which then allows them to define the SPN and PGN per the application requirements. One byte parameters have a resolution of 1 C / bit and a range of -40 C to 210 C. Two byte parameters have resolution of 0.03125 C / bit and a range of -273 C to 1735 C (per SAE J1939). Averaging Protection Communication CAN Network Termination RS-232 The Parameter Group Number (PGN) that will be used to send a temperature to the J1939 network will be entirely dependent on the Suspect Parameter Number (SPN) that was selected for that channel. In all cases, the PGN is a PDU2 type. Each PGN has a predefined priority and repetition rate associate with it. The average temperature of all the active channels can be broadcasted to the network using the default Engine Average Information PGN, or on a Proprietary B message. Open circuit detection Frozen data detection Over or under temperature detection High temperature shutdown detection 1 CAN 2.0B port, protocol SAE J1939 Digital isolation is provided for the CAN line. According to the CAN standard, it is necessary to terminate the network with external termination resistors. The resistors are 120 Ohm, 0.25W minimum, metal film or similar type. They should be placed between CAN_H and CAN_L terminals at both ends of the network. 1 RS-232 port is available for debugging purposes. ASCII Text Format, 115200 Baud Rate Data 8 bit, Parity None, Stop 1 bit. Flow Control Xon/Xoff. Short circuit protection to ground. TDAXRTD8 3

General Specifications Microprocessor Control Logic SAE J1939 Profile Diagnostics MC56F8366,16-bit, 512 kbyte flash program memory User programmable functionality with the Electronic Assistant : Node address is auto configurable as per J1939-81 and/or via customer configuration. Monitored parameters and diagnostics are user selectable from a drop down list in the EA. Monitored parameters and diagnostics are read-only over the network All parameter locations have default values that do not conflict. Units are pre-configured with default values at the factory. Refer to the user manual. Parameter values and diagnostic error codes are retained when the modules are de-energized. Easily selectable SPNs from a drop down list of the temperature SPNs supported by SAE J1939. User defined SPN and PGN s configurable with Electronic Assistant to suit the application. Configurable ECU Instance in the NAME to allow for multiple ECU s on the same network The bit-rate is 250 kbit/s. Other bit-rates (125 kbit/s, 500 kbit/s or 1 Mbit/s) can be factory programmed on request. Contact Axiomatic for an ordering p/n. Module is fully functional during configuration and communications. For J1939 compliance (SAE, Recommended Practice for a Serial Control and Communications Vehicle Network, October 2007) all modules comply with the applicable portions of the following: SAE J1939-21, December 2006, Data Link Layer SAE J1939-71, January 2009, Vehicle Application Layer SAE J1939-73, September 2006, Application Layer Diagnostics SAE J1939-81, May 2003, Network Management Customer specific proprietary extensions can also be included in the SAE J1939 profile on request. Configurable Diagnostic Messaging parameters Diagnostic Log is maintained in non-volatile memory. Each RTD channel can be configured to send diagnostic messages to the network if the temperature goes out of range. When sending an Active Diagnostic Trouble Code (DM1) or a Previously Active Diagnostic Trouble Codes (DM2) message, the controller will use the appropriate Diagnostic Trouble Code (DTC). As defined by the standard, this is a combination of the Suspect Parameter Number (SPN), the Failure Mode Indicator (FMI), Occurrence Count (OC) and the SPN Conversion Method (CM). User Interface Electronic Assistant, P/N: AX070502 Updates for the EA are found on www.axiomatic.com under the log-in tab. UL and cul Compliance UL508 (April 2010) (FTPM2) Controls for Stationary Engine Driven Assemblies cul C22.2 No. 14-10 (2010) CE Compliance 2004/108/EC (EMC Directive) 2011/65/EU (RoHS Directive) Vibration 11.48 G for a device rigidly mounted to a generator housing The marine type approval process tested to 4,0 G per IEC 60068-2-6, Test Fc. Marine Type Approval Lloyd s Register, DNV, ABS, RINA, GL, BV, CCS, IRS, RS The AXRTD8 meets the environmental, EMC and vibration requirements of generator set applications in marine installations. Operating Temperature Range -40 to 85 ºC (-40 to 185 ºF) Storage Temperature Range -50 to 120 ºC (-58 to 248 ºF) Humidity Protected against 95% humidity non-condensing, 30 ºC to 60 ºC Protection IP67, Pollution Degree 3 per UL508 The marine type approval process tested to IP56. Weight 2.2 lbs. (1.00 kg) TDAXRTD8 4

Enclosure Rugged aluminum housing, stainless steel end plates, neoprene gaskets 145.30 x 149.00 x 73.00 mm (5.72 x 5.86 x 2.87 ) L x W x H Connectors, Deutsch IPD P/N: 1 8-pin DT13-08PA, 1 40-pin DRC13-40PA Can be mounted directly on the power generator set or remotely Suitable for moist, high shock, vibrating and non-hazardous environments Dimensional Drawing Electrical Pin Out Power and CAN TDAXRTD8 5

Electrical Pin Out - RTD Mating Connector Part Number: Deutsch IPD p/n DRC16-40SE-A or DRC18-40SA or DRC16-40S with sockets 0462-201-16141 Specifications are indicative and subject to change. Actual performance will vary depending on the application and operating conditions. Users should satisfy themselves that the product is suitable for use in the intended application. All our products carry a limited warranty against defects in material and workmanship. Please refer to our Warranty, Application Approvals/Limitations and Return Materials Process as described on www.axiomatic.com/service.html. TDAXRTD8-10/02/15 TDAXRTD8 6