MS-7000: SuperStar Reader

Similar documents
MS-5000: MiniStar Reader

MS-5000 MiniStar Reader. Quick Start Guide MS The MS-5000 MiniStar Reader. 1.0 Specifications

MS-3000 MicroStar Reader

MS-4000: ShootingStar Reader

The Pyramid Series features five readers, each with its own unique characteristics, to meet virtually any requirements an end-user may have.

Pyramid Series Proximity Readers

1.3 Operating Conditions -40 F to 150 F (-40 C to 65 C) 0% to 90% Relative Humidity, non-condensing

PXL-250 Tiger Controller

Indala Reader Installation Guide

1.0 Wiring and Layout Diagrams

NXT-1R/-3R/-5R Exit Reader Installation Drawing 4-Conductor - OR - CAT-5 Cabling. IO-Plus (Green) Ground (Black) +12 VDC (Red) Shield (Silver)

TB21. NO - Relay. Relay. Common - Relay. NC - Relay. Input J23. Ground TB22 TB23. NO - Relay Common - Relay NC - Relay Input Ground.

FlexPass. ASR Long Range Reader. Installation Guide Jeronimo Road Irvine, CA July 16, 2007 Document Number K , Rev B

Installation Manual Rev D MiniProx Readers - Wiegand 5365B and Clock and Data 5368B

BioPointe Reader Installation Guide

Cardax Prox Plus Mifare Reader

Digital Keypad Introduction

IntelliPr ox 2000 KEYLESS ENTRY SYSTEM TO MANAGE ACCESS TO A SINGLE DOOR FOR UP TO 500 USERS NOW WITH D-LITE SOFTWARE

2000 Series e/em Style Keypad Installation and Programming Manual

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

Installation Instructions RF5010 and RF5210

EL-ST100 KEYPAD CONTROLLER

TCNM-ACBB1 Installation Manual

Installation Instructions

SP1 MP1 WP2 WP1. 125kHz reader models with the following prefixes: 13.56MHz reader models with the following prefixes:

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

CP150B Vandal & Weather Resistant Keypad Security Systems

Installation manual Card reader Sirius i80(p) o Product o Installation o Connection o Technical data

D O O R S T A T I O N W I T H P R O X I M I T Y R E A D E R

Operation Manual. Thank you for selecting Keyking products. Please read this manual thoroughly before use. Models: TC418/419 Standalone Controller

INSTALLATION INSTRUCTIONS Model 930 EntryCheck

Installation Instructions Installation Guidelines. Product Summary. For the maximum number of bus devices and touchpads per panel see Table 1.

Installation manual Card reader Sirius i80l(p) o Product o Installation o Connection o Technical data

Access Control for Houses 2 Wires Connection Doorline DR-200-SET Surface Mount Doorline DR-200-AV-SET Flush Mount

232iLM Keypad Installation and Programming Instructions

Trademark Generation II Series Intercom System Installation and Operation Reference Guide

Installation Instructions RF5010 and RF5210

Installation Manual Rev E MaxiProx Wiegand Reader 5375A

INSTALLATION INSTRUCTIONS FOR THE MINI-KEY SYSTEM. Doc Rev B

Copy Machine Reader. Installation and Setup Guide

INTERCOM SYSTEM Model ICA900

MRC350 Card Capture Reader

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

BioPointe Finger/Card Presentation

REX F-0-9 Standalone or Access Controller

SuperBus 2000 Phone Interface/Voice Module Installation Instructions

CM-110SK Standalone Keypad Installation Instructions

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

Waterproof. Keypad/Reader/Controller

232iLM Keypad Installation & Programming Instructions

Single Door Standalone Access Control User Manual

Technovision Inc. CD-ROM Audio Sampler. Repair Manual

AB-2D AB-2D SPEAKER A,B OR A+B SELECTOR INSTALLATION & OPERATION GUIDE

TruPortal Dual Door Interface Module Quick Reference

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

Connecting a Cisco Reader Module

KP2000E/EM Series Style Keypad

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

Proximity Card and Pin Reader Installation Manual

Quick Installation Guide MAC1000/MAC1000SR STANDALONE BIOMETRIC CONTROLLER

EntraGuard Bronze. Quick Start Guide. Telephone Entry. 1.0 Specifications. 2.0 Unit Installation

Two Door Controller GEN-045

IEI emerge MicroNode Install and Setup Guide. Contents

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

User Manual. PCKeypad Wireless Keypad

PIB300 and PIB301 User Guide. Installation and operation instructions for Panel Interface Board

Operation and Maintenance Manual

Installation and User Manual

NS1 Connection Unit Guide

Q WIEGAND EXPANSION MODULE

Suprex RS-485 SPX-7500 Wired Reader-Extender

HID EntryProx TM Keypad Reader/Door Access Control

DWG DESCRIPTION IRVINE, CALIFORNIA MANUAL, INSTALL, HID MIFARE READER REVISIONS INITIAL RELEASE PER EO #E6055-7

W3-M. Metal waterproof standalone access control/reader. User Manual

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

The Sentinel - Talon-SRX Breakout Board, rev A User s Guide

User Manual. Split access control with intelligent secured power supply.

M350. Embedded Mini-ITX Enclosure. Installation Guide Version 1.0

B&W RearView Camera Installation & Operation

AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL

Digital Proportional Valve Amplifier

FlexPass TM Advantage Series Proximity Plus TM ASR PowerProx TM Reader User Manual

Knowledge Base Article

icam7000s SERIES HARDWARE GUIDE Packing List CONTACTLESS CARD READER RECESS MOUNT (Optional) ISO/ANSI COMPLIANT EASY INSTALLATION What s in the Box

Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL

OSAB Optical Turnstile with Swing Arm Barrier Installation Manual

Zartek. CDP-808 Two Button Wireless Intercom Installers Manual

Thermometer / Barometer System

1 Installing the VG4-A-ARMPLATE

DP-222Q Color Video Door Phone Manual

RBR-SB-KTZ001 LAR 2. User Manual

Zodiac FR100 TM INSTALLATION MANUAL

Installation procedure Hands free reader: L51 - R1x Variant

ATP1000 Touchpad/Display Installation Instructions

DP-222Q Color Video Door Phone Manual

iclass INSTALLATION GUIDE

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

Clipsal Bus Couplers. Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems

W3-H Waterproof Keypad/Reader/Controller

Transcription:

The MS-7000 SuperStar Reader The MS-7000 SuperStar Reader is intended for installation in proximity applications where an extended read range is required. The reader provides an audio beeper and a multi colored LED to annunciate the reader's status when used on a PXL-250, PXL-100, or IntelliProx. Amber to indicate normal operation awaiting an access event Green to indicate a valid card has been presented or the door has been unlocked for access Red to indicate an invalid card has been presented or the door is in an alarm condition The MS-7000 SuperStar Reader is housed in a black or white, weatherproof, shock resistant package. The reader provides optimum performance when mounted at least four inches away from metal surfaces; read range is reduced if the reader is mounted on or near metal surfaces. Specifications Dimensions 8.50 inches High x 6.00 inches Wide x 0.75 inches Deep 21.59 cm High x 15.24 cm Wide x 1.91 cm Deep Drill Beeper Recess 0.75" (3/4") Drill Cable Access Hole 0.375" (3/8") 8.50" H 3.25" to Beeper Recess Center 2.35" to Cable Hole Center LED 2.65" to Beeper Recess Center 2.90" to Cable Hole Center 6.00" W 6.60" Quick Start Guide MS-7000 #10 Screw - 4x 0.925" 0.75" D 0.825" 4.30" Mounting Holes - 4x Figure 1 MS-7000 Dimensions (800) 260-5265 (408) 451-2520 FAX (408) 441-0309 Page 1 of 6

Quick Start Guide Operating Voltage 11v to 14v DC @ 200 ma Cable Specifications up to 250 feet using six conductor, shielded, stranded AWG 24 wire up to 500 feet using six conductor, shielded, stranded AWG 20 wire Mounting Instructions Five holes need to be drilled to mount the SuperStar Reader (see Figure 1 on page 1). One hole (0.375" 3/8") accommodates the reader cable. Four holes are for mounting the reader on a wall surface (hole size is dependent upon the size of the mounting screw a #10 screw is recommended). A small recess may be necessary to accommodate the beeper (0.75" 3/4" x 0.20" Deep). For parking or similar applications, the SuperStar Reader can be mounted to a metal "gooseneck" stand. Since the Reader cannot be mounted directly to a metal surface without affecting read range, the Reader must be mounted on some kind of a nonmetallic mounting plate, which is then mounted to the gooseneck stand. The larger the mounting surface of the gooseneck stand, the greater the distance required between reader and mounting surface. A nonmetallic (PVC) mounting plate is available from Keri Systems (p/n MP-7) for these applications. For a stand with a mounting surface of 4 inches by 4 inches or smaller, the MP-7 mounting plate provides 1/2 inch of separation between the reader and the gooseneck mounting surface. If the mounting surface is larger than these dimensions, additional mounting plates may be necessary to provide the necessary distance between Reader and stand to ensure optimum read range. MS-7000 Connections The SuperStar Reader does not require configuration; there are no switches or jumpers to set. The SuperStar Reader is normally connected to a PXL-250, PXL-100, or IntelliProx, but can be connected to an alternative host controller/alarm panel through an IntelliProx used in its Wiegand input device mode. All connections needed to support the reader are made through the reader's cable. Please consult the tables on pages 2 and 3 for specific connection instructions. (800) 260-5265 (408) 451-2520 FAX (408) 441-0309 Page 2 of 6

PXL-250 Connections The "A" reader connects to TB5, pins 1 through 6 (TB5 has a seventh pin, but no connection is made to that pin). The "B" reader connects to TB6, pins 1 through 6 (TB6 has a seventh pin, but no connection is made to that pin). Connecting to the PXL-250 TB5 or TB6 1 Reader Antenna Blue 2 Beeper Green 3 Reader Power Red 4 Reader Ground Black 5 Green LED Brown 6 Red LED White 7 no connection 4 Shield Silver Figure 2 PXL-250 Connections Design 5 PXL-100 Connections The "A" reader connects to TB2, pins 14 through 19. The "B" reader connects to TB3, pins 20 through 25. Connecting to the PXL-100 TB2 14 Green LED Brown 15 Beeper Green 16 Reader Power Red 17 Reader Ground Black 18 Reader Antenna Blue 19 Red LED White 17 Shield Silver Connecting to the PXL-100 TB3 20 Green LED Brown 21 Beeper Green 22 Reader Power Red 23 Reader Ground Black 24 Reader Antenna Blue 25 Red LED White 23 Shield Silver 1 2 3 4 5 6 7 1 2 3 4 5 6 7 1 3 12V 5V JP4 14 15 16 17 18 19 20 21 22 23 24 25 TB5 - "A" Reader on the Motherboard Receiver Board Connectors to the Motherboard TB6 - "B" Reader on the Receiver Board S1 TB2 "A" Reader TB3 "B" Reader Figure 3 Design 5 PXL-100 Connections Quick Start Guide MS-7000 NOTE: Please contact customer support at Keri Systems for information regarding connecting a Reader to a Design 4 PXL-100. A Design 4 PXL-100 can be identified by the location of its power connection made at the middle of the left edge of the printed circuit board. (800) 260-5265 (408) 451-2520 FAX (408) 441-0309 Page 3 of 6

Quick Start Guide IntelliProx Connections The reader connects to TB1, pins 1 through 6. Connecting to the IntelliProx TB1 1 Reader Antenna Blue 2 Beeper Green 3 Green LED Brown 4 Red LED White 5 Reader Power Red 6 Reader Ground Black 6 Shield Silver 1 2 3 4 5 6 TB1 - Reader Figure 4 IntelliProx Connections Installation Verification The following information applies to an installation with a Keri Systems controller or IntelliProx unit. When used with an alternative host controller/alarm panel through an IntelliProx used in its Wiegand input device mode, the actions of the reader's LED and beeper are controlled by the alternative host controller/alarm panel and might not match those of a Keri Systems controller. TB2 7 8 The reader's power is provided by the controller, so the reader is powered on when the controller is powered on. The reader's normal state is to display a constantly on Amber LED as it waits for a card or tag to be presented. To verify the reader is functioning properly, pass a Keri Proximity Card or a Keri Key Tag within a few inches of the reader. The reader will beep and either the Green or Red LED will flash (depending upon whether or not the card/tag has been enrolled at the controller) and then return to steady Amber. MS-7000 To verify the reader's read range, hold a Keri Proximity Card or a Keri Key Tag parallel to the reader, about 2 feet away and slowly draw the Card/Tag in toward the reader. Note the distance when the reader recognizes the card. The SuperStar reader's range will be up to 16 inches depending upon the installation conditions, the material on which the reader is mounted, and whether it is a card or a tag being read. Due to the physical size difference between cards and tags, cards provide approximately 50% greater read range than tags. Refer to the Troubleshooting the Reader Installation section if the reader is not functioning properly. (800) 260-5265 (408) 451-2520 FAX (408) 441-0309 Page 4 of 6

Troubleshooting the Reader Installation Problem Probable Cause Corrective Action 1. One or more of the reader's wiring connections are incorrect. The reader does not recognize a card/tag (no beep, no LED flash). The reader does not recognize a card/tag (no beep, no LED flash). The reader has a short read range. 2. The reader is not receiving proper power from the controller. 3. The reader is mounted too close to a device that radiates electromagnetic interference. 4. A jumper is not set correctly on the controller. 1. The reader's controller is not properly grounded. - continued next page - Power down the controller and verify the wiring connections are correct for the reader/controller combination per the instructions provided in the Connections section on pages 2 and 3. Verify the voltage supplied by the controller is between 11 and 14 VDC. Devices such as computer monitors radiate electromagnetic interference that affects read range. When possible, relocate either the reader or the device to provide a greater distance between the two. For a PXL-250: Verify there is a jumper across pins 1 and 2 of JP4 (refer to the Technical Reference manual for more information Keri p/n 01836-001). For a PXL-100: If the controllers are using TAP software, verify JP1 on the controller and the jumper on the Receiver card (1) are installed across both jumper pins. If the controllers are using Doors software, verify JP1 on the controller and the Receiver card (1) are not installed across both pins (typically the jumper will be installed onto one of the pins to keep it available). For an IntelliProx: Verify there is not a jumper across pins 1 and 2 of JP1 (typically the jumper can be installed onto one of the pins to keep it available). Ensure there is a quality earth ground connection made to the controller. Refer to the controller's documentation for specific information regarding the earth ground connection. Quick Start Guide MS-7000 (1) The receiver board's jumper is on the underside of the board. Gently pull the receiver board away from the controller, verify the jumper setting is correct per your application, carefully align the connectors on the receiver board with the pins on the controller, and gently push the receiver board back into place. (800) 260-5265 (408) 451-2520 FAX (408) 441-0309 Page 5 of 6

Quick Start Guide Problem Probable Cause Corrective Action 2. The shield wire for the Verify the shield line from the controller reader's cable has opened somewhere between the reader and the controller. to the reader is one continuous, connected line. Refer to the controller's installation documentation and verify the shield line is correctly connected to 3. The reader is mounted too close to a metallic object. 4. The reader is mounted too close to a device that radiates electromagnetic interference. the controller. Remove the reader from its mounting surface and ensure there is no metal on the mounting surface within 4 inches of the reader. Devices such as computer monitors radiate electromagnetic interference that affects read range. When possible, relocate either the reader or the device to provide a greater distance between the two. MS-7000 (800) 260-5265 (408) 451-2520 FAX (408) 441-0309 Page 6 of 6