Ademco Vista-20SE/First Alert FA-162C Program Sheet

Similar documents
Property of Monitronics Inc

Property of Monitronics Inc

Property of Monitronics Inc

First Alert FA160C/162C Installer Notes M. Leuck

Installer Notes 4110DL/XM, Vista 10, Vista-20, Via-30PSE

VISTA-20BAY PROGRAMMING GUIDE SECURITY SYSTEM SINCE 1946

Ademco/Protection One 250P1-1 Programming Form

VISTA-20SEa. 3-Partition Security System. Programming Form. V20SEaPRV1 9/98

3 6HFXULW\6\VWHP 3URJUDPPLQJ)RUP K4332 9/99 BYPASS NOT READY ARMED READY 4 MAX 5 TEST 6 BYPASS 7INSTANT 8 CODE 9CHIME READY ARMED

CUSTOMER INFORMATION

DAYLIGHT SAVINGS TIME START/END MONTH [ 0 ]0 = Disabled; 1 = Enabled. 1 Start End

VISTA-128BP/VISTA-250BP Programming Form

Property of Monitronics Inc

4140XMPT2 PROGRAMMING FORM

FA168CPS / FA168CPSSIA FA148CP / FA148CPSIA

Programming Default Tables

*00 INSTALLER CODE Enter 4 digits, 0-9 [4140] *28 POWER UP IN PREVIOUS STATE [1=yes] 0=no; "1" for UL.

VISTA-50P VISTA-50PUL

LYNX Security System 3URJUDPPLQJ)RUP 6XPPDU\RI&RQQHFWLRQV. Features Q.E.D. programming for quick enrollment of devices.

ADEMCO VISTA-48A Security Systems

5HDG\*XDUG56HULHV 6H XULW\6\VWHPV 3URJUDPPLQJ*XLGHIRU5HDG\*XDUG5DQG 5HDG\*XDUG5(1 K /01 OFF AWAY STAY AUX

ADEMCO LYNXR-ENSIA Security System

Commercial Burglary Partitioned Security System With Scheduling. Programming Guide. K5894PRV4 6/04 Rev A

1HWZRU;1;( Table of Contents. General Description...2. Ordering Information...2. Feature Definitions...3. Programming the LED Keypads...

RANGER 9000E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Commercial Fire and Burglary Partitioned Security System with Scheduling. Programming Guide. K0376PRV5 2/11 Rev. A

VISTA 12a / 48a TECHNICAL TRAINING. The Best in Security plus Everyday Convenience & Control

&RPPHUFLDO)LUHDQG%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

I-NX8V2-IM Rev F Dec NetworX Series NX-8V2 Control Panel Installation and Setup

4XLFN6WDUW*XLGH. LYNXR is not intended for UL985 Household Fire applications.

APX32EN Security Systems

3DUWLWLRQHG6HFXULW\6\VWHPV ZLWK6FKHGXOLQJ

Created by: Alarm System Store Quick Start Guide. for Interlogix NetworX NX4, NX6 & NX8

High Security and Access System EVO48 V2.1 EVO192 V2.1

Control Panel ICP-SOL2-P/ICP-SOL3-P. en Quick Reference Guide

Series. NX-8-EUR Control Panel. Installation manual

2 IDS LCD Keypad User Manual C Issued March 2009

Lynx Plus Security System

Important Notice. Customer Information. 2 WisDom User Manual

MCM Electronics MCM Electronics MCM Electronics. The Icon Series. Installation and Programming Information. Icon 8 Version 5.0

Safecom Solution-16 Quick Reference Guide ISSUE 1.10

NetworX Series NX-8V2 Control Panel Installation and Startup

IDS1200 INSTALLER MANUAL. Summary of Operation 2 IDS1200 INSTALLER MANUAL - NO B ISSUED AUGUST 2002 VER 1.18

ADEMCO VISTA SERIES VISTA-20P / VISTA-20PSIA VISTA-15P / VISTA-15PSIA Security Systems

Programming Worksheets

Installation Instructions

DAS 250L CONTROL COMMUNICATOR INSTALLATION MANUAL

IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO D ISSUED NOVEMBER 2002 VERSION 2.

PROGRAMMING HELP GUIDE

VISTA-40. Programming Guide. 2-Partition Security System. Single Partition and 2-Partition Programming Forms N7001PRV4 7/98

Contents. 4. Disarming the Control Panel How to Disarm with a User Code How to Disarm using a Key-Switch or Remote...

Digiplex EVO High Security and Access System What s New EVO192 V2.7

NX-148 LCD KEYPAD INSTALLATION MANUAL

Modules Programming Guide. paradox.com

FOCUS 200 PLUS A CCC #: _ / / _ / ( _ ) _ - 35(/,0,1$5< -8/< Security Services CUSTOMER CONTROL UNIT TELEPHONE NUMBER:

Quick Start: 2. Connect AC power first and then the battery. 3. Configure the keypad (see page 44).

D1260/D1260B. Owner's Manual. Keypad

EVOHD. Programming Guide. Version

INSTALLATION MANUAL. Table of Contents. General Description Position Dip Switch Settings Enrolling the NX216-E Expander...

VISTA-50PADT VISTA-50PADTUL

Control Panel Solution 2000 / 3000

GEM-P9600 CONTROL PANEL/COMMUNICATOR

Solution 16 plus. User Guide Security System

IDS X-Series User Manual E Issued June 2013

DSC programming for the Alexor and Impassa

INPUTS: Are 10K end of line monitored, with a response time of 300 ms. Alarm triggers SIREN, STROBE and REPORTING (depending on setup)

Telephone and Reporting Setup in ElkRP

Control Panels D9412GV4/D7412GV4. en Owner's Manual

MG/SP Series (V4.9/V5.1) What s New

Developer s Guide. PC54O1 Serial Interface Module Version 1.0

Bosch solution 6000 cheat sheets

Control Panels B9512G/B8512G/B6512/B5512/B4512/B3512. en Owner's Manual

AMAX panel. AMAX panel 2100 AMAX panel 3000 AMAX panel 3000 BE AMAX panel en Operation Manual

XT30/XT50 PROGRAMMING PART 1. Slide 1. Slide 2. Slide 3. Objectives. XT30/XT50 Basic Training Programming- Part 1. Accessing the Programmer

R A D I O N I C S. D7212B Control/Communicator Program Entry Guide C 9/95

2 4PI175 issue 1_6/01. How to unset system in alarm. Programs 1, 2 and 3. Access codes. How to operate Personal Attack

(To modify t he installer code, ref er to section [ 1000], Installer Code Programming on page 21) 1234 or

THE OPERATOR INTRODUCTION 2 ACCESSING YOUR SYSTEM 2 FUNCTIONS OF THE "OPERATOR" 3 PROGRAMMING/CHANGING ACCESS CODES 12 ACTIVATING EMERGENCY ALARMS 13

VISTA-10SE, VIA-30PSE, VISTA-20SE E2 ZONE PROGRAMMING. An Improved Zone Programming and 5800 Wireless Device Enrollment Procedure

Modules Programming Guide

FSK TX CELLULAR PLUS. Installation and Programming Guide. Tel:

i Note Intrusion Control Panel Solution 64 Release Notes for Version Release Notes March, 2007

DAS ALPHA NUMERIC LCD CODEPAD INSTALLATION MANUAL

XR500/XR100 Command Processor Review. a) Zone expanders c) Output expanders b) All of these d) Single point detectors

SOFTWARE VERSION 3.10

Security System. Owner s Manual

SILENCING AN ALARM. When the alarm bell or siren is sounding, enter your user code or present your keyfob to your keypad.

SECURITY MODULE CG3 User Manual

VISTA-120. Installation and Setup Guide. Partitioned Security System with Scheduling. N5944-8V1 Rev. B 6/99

SOFTWARE VERSION 3.20

Emergency Dialer DIAL-ALERT MODEL: AD-105.

NX-1248E LCD KEYPAD Installation and Setup

LCD User Station User Manual

Table of Contents. Phone number configuration...15 Alarm Phone numbers, 1, 2 & Divert phone numbers 1, 2 &

INT-TSI Brief User Manual

Includes: 413oxM 513oxM 414oxM 414oxMP

Applicable to the EURO 46, 76, 162 and 280 control panels, software V9 or above.

Solution 144 Security Systems

SUPERPLEX. User s Manual. High performance, simplified wireless home security controller. Products that work. Software Release: V2.

SOFTWARE VERSION 3.10

Transcription:

Enter Program 1. 4112 + 8 + 0 + 0 (Display should show 20) or Power down then back up and press * and # within 1 minute (If exiting programming you can re-enter within 1 minute by pressing * and #) Exit Program 1. *98 OR 2. *99 if needing to re-enter programming later by Code + 8 + 00 Move to Location View Location * + Location # + Location (Display will read off one digit at a time) Send to 1. Exit programming Downloader 2. Press Installer or Master Code + # + 1 3. "CC" or "MODEM COMM" appears for approx. 2 minutes 4. Display will return to normal once upload is finished Partition Notes (If system is Partitioned) 1. Press *91 2. Enter Partition (1 or 2) 3. Enter location (all locations on this page marked (Partition Specific)) 4. Press *99 to return to regular panel programming *20 Installer Code I _ 4 _I _ 1 _I _ 1 _I _ 2 _I *21 Quick Arm Enable I _ 1 _I 0 = No *22 RF System Type I _ 0 _I 0 = None 1 = 5800 Wireless *23 Forced Bypass Enable I _ 0 _I 0 = No *24 RF House Code I _ 0 _I _ 0 _I 00 = Disabled, 01 to 31 Partition 2 House Code = Partition 1 House ID + 1 *25 Wired Expansion Module I _ 0 _I 0 = None 1 = 4219 8-Zone Expander 2 = 4229 Zone Expander Module 3 = 4204 Relay Module *26 Chime by Zone I _ 0 _I 0 = No (Program Zones in Zone List 3) *27 X-10 House Code I _ 0 _I 0 = A 1 = B 2 = C 3 = D 4 = E 5 = F 6 = G 7 = H 8 = I 9 = J #10 = K #11 = L #12 = M #13 = N #14 = O #15 = P *28 4285 Voice Module Access Code I _ 0 _I _ 0 _I 00 = Disabled (Allows access to Voice module) 1st digit = 1 to 9 2nd digit = # + 11 = * or # + 12 = # *29 Output to Long Range Radio I _ 0 _I 0 = No *31 Single Alarm Sounding/Zone I _ 0 _I 0 = No *32 Fire Sounder Timeout I _ 0 _I 0 = Timeout 1 = No Timeout *33 Alarm Bell Timeout I _ 0 _I 0 = None 3 = 12 minutes 1 = 4 minutes 4 = 16 minutes 2 = 8 minutes *34 Exit Delay I _ 6 _I _ 0 _I 00 to 99 Seconds *35 Entry Delay 1 I _ 3 _I _ 0 _I 00 to 99 Seconds *36 Entry Delay 2 I _ 3 _I _ 0 _I 00 to 99 Seconds *37 Audible Exit Warning I _ 1 _I 0 = No *38 Confirmation of Arming Ding I _ 0 _I 0 = No Page 1

2 = Yes RF only *39 Power Up in Previous State I _ 0 _I 0 = No *40 PABX Access Code I I I I I (If 9 is needed to dial add here) *41 Primary Phone (12 digits) I I I I I I I I I I I I I End Phone with * # + 11 = * # + 12 = # # + 13 = 2.5 second pause *42 Secondary Phone I I I I I I I I I I I I I *43 Primary Account Partition 1 I I I I I (Last 4 of Account) A = # + 10 B = # + 11 C = # + 12 D = # + 13 E = # + 14 F = # + 15 *44 Secondary Account Partition 1 I I I I I *45 Primary Account Partition 2 I I I I I *46 Secondary Account Partition 2 I I I I I *47 Phone System Select I _ 1 _I 0 = Pulse Dial 1 = DTMF Dial 2 = Pulse Dial, CS on Watts Line 3 = DTMF Dial, CS on Watts Line *48 Report Format I _ 7 _I Partition 1 0 = 3/1, 4/1 Ademco L/S Standard I _ 7 _I Partition 2 1 = 3/1, 4/1 Radionics Standard 2 = 4/2 Ademco L/S Standard 3 = 4/2 Radionics Standard 6 = 4/2 Ademco Express 7 = Contact ID 8 = 3/1, 4/1 Ademco L/S Expanded 9 = 3/1, 4/1 Radionics Expanded *49 Split/Dual Reporting I _ 0 _I Use 6 if Pager To Primary Phone To Secondary Phone 0 = All reports Backup Only 1 = Alarms, Restore, Cancel All Other Reports 2 = All Reports except Open/Close, Test Open/Close, Test 3 = Alarms, Restore, Cancel All Reports 4 = All Reports except Open/Close, Test All Reports 5 = All Reports (Dual Reporting) All Reports 6 = All reports except Open/Close Alarms, Open/Close, Troubles 7 = All reports Alarms, Troubles 8 = All reports Alarms, Open/Close, Troubles 9 = All reports except Open/Close Alarms, Open/Close for Users 5-25, Troubles *50 15 Second Dial Delay I _ 0 _I 0 = No *51 Periodic Test Message I _ 0 _I 0 = None 1 = 24 Hours 2 = Weekly 3 = Monthly *52 Test Report Offset I _ 0 _I 0 = Disabled 1 = 6 Hours 2 = 12 Hours 3 = 18 Hours *53 Sescoa/Radionics I _ 0 _I 0 = Radionics 1 = Sescoa 0 = All Others Page 2

*56 Zone Assignments Must use 6139 Alpha Keypad here 1. Depending on version of system one of these may appear (If "Program Tool?" press 0, if "Set to Confirm?" shows press 1) 2. Enter Zone to program (01 to 99) (* for next, # for previous menu) Hardwire Zones 01 to 08 4219/4229 Expander Zones 10 to 17 Receiver Trouble Zone 09 Wireless Zones 10 to 39 (Depends on receiver capacity) Duress Zone 92 Fire Panic Zone 95 Medical Panic Zone 96 Police Panic Zone 07 3. This shows current summary of Zone programming (* for next, # for previous menu) 4. Enter Zone Type (* for next, # for previous menu) 00 = Zone Disabled 08 = 24 hour Aux/Medical 01 = Delay Zone 09 = Fire 02 = Do not Use 10 = Interior Delay 03 = Perimeter/Instant 20 = Arm-Stay (RF only) 04 = Interior Follower/Motions 21 = Arm-Away (RF only) 05 = Trouble by Day/Alarm by Night 22 = Disarm (RF only) 06 = 24 hour Silent/Holdup 23 = No Alarm Response 07 = 24 hour Police Panic 24 = Silent Burglary 5. Enter Response Time Zones 1 to 8 (* for next, # for previous menu) 0 = 10msec 1 = 350msec (Default) 2 = 700msec 6. Program Partition of Zone (* for next, # for previous menu) 1 = Partition 1 2 = Partition 2 7. Enter Report Code (* for next, # for previous menu) (10 in first section gives a report of A0) 7. Enter type of Sensor Hardwire Zones will advance to step 11, for Wireless Zones continue (If it doesn't go to next steps check if Receiver has been programmed in *22) 2 = Auxiliary Wired Sensor (if 4219/4229 Zone Expander) 3 for Supervised RF (most sensors are RF) 4 for Un-Supervised RF 5 RF Button Type (Keyfobs/Panics etc) (New versions may skip step 8 and move to step 9, learn Loop number after learning sensor) 7. Enter Loop number (Some older systems show this) (* for next, # for previous menu) Door Switch Internal switch Loop 2, external sensor Loop 1 Glassbreak Loop 1 Smoke Detectors Loop 1 Motions Loop 1 Keyfobs (Each button = 1 zone) Loop 1 Bottom Right Button Loop 2 Top Right Button Loop 3 Top Left Button Loop 4 Bottom Left Button 8. Serial Number Programming Page 3

Press 1 and enter serial number or trip sensor twice, 1 st time to learn, 2nd to confirm Note: Serial number found on sticker on of sensor This shows ready to learn This shows Serial Number either manually entered or learned This shows sensor was confirmed by activating twice 9. This is the new programming of sensor (* for next, # for previous menu) 10. Normally press 0 to return to start or 1 if if customer has 6139 keypad *59 Exit Alarm Report Code I _ 0 _I *60 Trouble Report Code I _ 1 _I _ 0 _I *61 Bypass Report Code I _ 0 _I _ 0 _I *62 AC Loss Report Code I _ 1 _I _ 0 _I *63 Low Bat Report Code I _ 1 _I _ 0 _I *64 Test Report Code I _ 0 _I _ 0 _I *65 Open Report Code I _ 0 _I *66 Away/Stay Report Code I _ 0 _I _ 0 _I (1st digit Stay, 2nd Away) *67 RF Xmtr Low Bat Report Code I _ 0 _I _ 0 _I *68 Cancel Report Code I _ 1 _I _ 0 _I *70 Alarm Restore Report Code I _ 0 _I *71 Trouble Restore Report Code I _ 0 _I _ 0 _I *72 Bypass Restore Report Code I _ 0 _I _ 0 _I *73 AC Restore Report Code I _ 0 _I _ 0 _I *74 Low Bat Restore Report Code I _ 0 _I _ 0 _I *75 RF Low Bat Restore Report Code I _ 0 _I _ 0 _I *76 Test Restore Report Code I _ 0 _I _ 0 _I *80 Output Device Programming *81 Zone Lists for Output Devices *82 Custom Alpha Editing *83 Sequential Mode *89 Event Log 80% Full I _ 0 _I _ 0 _I *90 Event Logging I _ F _I 0 = None 1 = Alarm/Restore 2 = Trouble/Restore 4 = Bypass/Bypass Restore 8 = Open/Close *91 Option Selection I _ 0 _I 0 = None 4 = AAV 2-way module enabled (4 disables siren during 2-way) *92 Phone Monitor Enable I _ 0 _I 0 = Not Used (Panel MUST be properly grounded for this to work!) 1 = KP Display 2 = KP Display/Sounder Page 4

3 = KP Disp/Sounder/Device 2 starts *93 Reports per Armed Period I _ 0 _I 0 = 10 per Armed period 1 = Unlimited per Armed period *94 Download Phone Number I _1 _I _ 8 _I _0 _I _ 0 _I _6 _I _ 8 _I _2 _I _ 1 _I _6 _I _ 9 _I _0 _I I *95 Ring Count I _# 15 _I 0 to #15 #15 = Answer Machine Defeat *96 Reinitialize Download (No Value needed, keypad will just beep) *97 Default Panel (No Value needed, keypad will beep and default panel) *98 Exits Program Mode (Will not allow re-entry with Installer Code + 8 + 0 + 0) *99 Exits Program Mode (Will allow re-entry with Code + 8 + 0 + 0) *80 Output Device Programming (If 4204 Relay/4219/4229 Relay Zone Expander is used) 1. Enter Device to program (01 to 04) (* for next, 00 to exit) 01 to 02 for 4229 Relay/Zone Expander 01 to 04 for 4204 Relay Module 01 to 08 for X-10 2. This shows summary of current Relay START programming (* for next, # for previous menu) (What starts the Relay) 3. This shows summary of current Relay STOP programming (* for next, # for previous menu) (What stops the Relay) 4. Enter what Relay will do when activated (* for next, # for previous menu) 0 = No Response (or skip) 1 = Close for 2 seconds 2 = Close and stay closed 3 = Continuous Pulse On/Off 5. Enter what will start the Relay (optional) (* for next, # for previous menu) 0 = Not Used (or skip) 1 = on an Alarm 2 = on a Zone Fault (or Keyfob button) 3 = on a Trouble 6. Enter Zone List from *81 which STARTS Relay (optional) (* for next, # for previous menu) 0 = Not Used (or skip) 1 = Zone List 1 2 = Zone List 2 3 = Zone List 3 7. Enter Zone Type that will START the Relay (optional) (* for next, # for previous menu) 00 = Not Used (or skip) 24 = Silent Burglary 01 = Entry/Exit Zone 31 = End of Exit Time 03 = Perimeter/Instant Zone 32 = Start of Entry Time 04 = Interior Follower/Motions 33 = Any Burglar Alarm 05 = Trouble by Day/Alarm by Night 36 = Bell Timeout or Disarm 06 = 24 hour Silent/Holdup 38 = Chime 07 = 24 hour Police Panic 39 = Any Fire Alarm 08 = 24 hour Aux/Medical 40 = Bypassing 09 = Fire 41 = AC Power Failure 10 = Interior Delay 42 = System Low Battery 20 = Arm-Stay 43 = Communication Failure 21 = Arm-Away 52 = Kissoff 22 = Disarming 58 = Duress 8. Enter which Partition will START this Device (Optional) (* for next, # for previous menu) 0 = Any Partition 1 = Partition 1 2 = Partition 2 Page 5

9. Enter Zone List that will STOP the Relay (optional) (* for next, # for previous menu) 0 = Not Used/Skip 1 = Zone List 1 2 = Zone List 2 3 = Zone List 3 (for Chime by Zone Feature) 10. Enter Zone Type that will STOP the Relay (optional) (* for next, # for previous menu) 11. Enter which Partition will STOP this Device (Optional) (* for next, # for previous menu) 0 = Any Partition 1 = Partition 1 2 = Partition 2 12. This shows summary of new Relay START programming (* for next, # for previous menu) 13. This shows summary of new Relay STOP programming (* for next, # for previous menu) 12. Enter next Relay/Device to program or 00 to exit *81 Zone Lists for Output Devices 1. Enter Zone List to program (01 to 03) or 00 to Quit (* for next, # for previous menu) 1 = Zone List 1 2 = Zone List 2 3 = Zone List 3 and/or Chime Zones 4 = Zone List 4 (Common Lobby Zones) 2. Enter Zone Number to add to List (01, 02 etc) or 00 to Quit (* for next, # for previous menu) Multiple Zones can be added (example: 01* 03* 25*etc) 3. If deleting a Zone List enter (01 to 03) or 0 to skip (* for next, # for previous menu) 4. If deleting Zone within Zone List enter 1 or 0 to skip (* for next, # for previous menu) 4a. If 1 was entered from previous step enter here then 00 (* for next, # for previous menu) Multiple Zones can be deleted (example: 01* 03* 25*etc) 5. Enter next Zone List to program or 00 to Quit (* for next, # for previous menu) Page 6

*58 Keyfob/Zone Quick Learn Programming (Only with E2 enabled panels) Learns all 4 Zones at once, panel reserves 8 zones for keyfobs (Zones 49 to 56) *58 Expert Programming (Must use 6139 or 6160 Alpha Keypad here) 1. Press 1 here to allow confirming sensor after serial number input 2. Keypad displays summary of current programming, press D key and do NOT press * 3. Enter Template For standard 5804 use Template 3 (best choice) then * For 5804Bi-Directional use Template 6 (best choice) then * 5804 Standard Keyfobs 5804BD/BDV Bi-direction Keyfob Template 1 Loop 1 = 23 (No Response) Template 4 Loop 1 = 23 (No Response) Loop 2 = 22 (Disarm) Loop 2 = 23 (No Response) Loop 3 = 21 (Arm Away) Loop 3 = 21 (Arm Away) Loop 4 = 23 (No Response) Loop 4 = 22 (Disarm) Template 2 Loop 1 = 23 (No Response) Template 5 Loop 1 = 23 (No Response) Loop 2 = 22 (Disarm) Loop 2 = 20 (Arm Stay) Loop 3 = 21 (Arm Away) Loop 3 = 21 (Arm Away) Loop 4 = 20 (Arm Stay) Loop 4 = 22 (Disarm) Template 3 Loop 1 = 07 (24 Hour Audible) Template 6 Loop 1 = 07 (24 Hour Audible) Loop 2 = 22 (Disarm) Loop 2 = 20 (Arm Stay) Loop 3 = 21 (Arm Away) Loop 3 = 21 (Arm Away) Loop 4 = 20 (Arm Stay) Loop 4 = 22 (Disarm) 4. this is template 3 settings for 5804 (Left) or Template 6 for 5804BD/BDV (Right) 5. Panel searches highest free 4 consecutive Zones then displays 1st of the 4 Zones (in this case 53) 6. Press * to accept template and learn sensor (Do not worry about Loop numbers) Press any key on sensor to learn or manually enter serial number Trip sensor again to confirm (will show matching serial numbers) 7. Panel now searches next highest free 4 consecutive Zones for next keyfob (in this case 49) Press * for next keyfob or 00 for normal *58 Zone programming Keyfobs will NOT operate until assigned to a User (see below) User Assign 1. Master Code + 8 + User (02 to 33) + # + 4 2. Enter 1st keyfob Zone (in above example Zone 53) Page 7

Page 8

Page 9 Monitronics Monitoring and Service: 1-800-447-9239 Ademco Vista-20SE/First Alert FA-162C Quick Reference Guide Arm Away User Code + AWAY key (2) Note: If system shows NOT READY press to view open zones Arm Stay User Code + STAY key (3) Disarming / Silencing Alarms User Code + OFF key (1) If turning off an alarm enter User Code + OFF key (1) again to clear display Instant Doors User Code + INSTANT (7) to arm system Entry/Exit doors will arm instant and motion detectors will be bypassed (display will show both STAY and INSTANT) Zone Bypassing User Code + BYPASS key (6) + zone (01 to 30) Note: Fire/Smoke Detector Zones cannot be bypassed User Codes Enter MASTER CODE + CODE key (8) Enter User to program (03 to 15) Enter new 4-digit User Code (Keypad will beep if command is successful) To delete a code Enter MASTER CODE + CODE key (8) Enter User to delete (03 to 15) then wait 3 seconds (Keypad will beep if command is successful) Master Code can be changed by entering MASTER CODE + CODE (8) + 02 + New MASTER CODE twice Door Chimes Master Code + CHIME (9), if activated the display will show CHIME, repeat to turn Chimes OFF Trouble Display NO AC = Loss of AC power to the system LOW BAT = Main panel has a low battery, if LOW BAT appears with a zone number that zone has low battery CHECK = There is a problem with a wireless zone, fire zone or the main systems wireless receiver Panic Buttons By holding down a combination of numbers will activate the Police, Fire and Medical Panics Press and # at same time for Police Panic Press 1 and at the same time for Fire Panic Press 3 and # at the same time for Medical Panic Note: The Fire and Medical Panics may be reversed or disabled on some systems Do not pause more than 2 seconds between each keypress or system will ignore above commands