ASYNCHRONOUS SERIAL CONVERTER RS485/USB S107USB/K107USB

Similar documents
K107A / K107B Half-duplex RS485 serial bus with 3-point insulation

K-LINE. USB RS485 Asynchronous Converter CONVERTERS AND INTERFACES. Serial Converters

RS232/USB and TTL/USB ASYNCRONOUS SERIAL CONVERTER CB CONFIG BOX

RS232/USB, TTL/USB and RS485/USB ASYNCRONOUS SERIAL CONVERTER CONFIG BOX PLUS

Product EASY-USB. Description. USB - UART TTL converter. Seneca s.r.l. Series of product. Pag.

Strain Gauge Converter

S SENECA. Installation Manual Z-TWS4. Z-PC Line. Web Multifunction Controller Straton / Linux

USER MANUAL Z-8NTC 8 CHANNELS NTC TEMPERATURE SENSOR CONVERTER WITH USB / RS485 PORT AND MODBUS RTU PROTOCOL

INSTALLATION MANUAL Z-UMTS

Installation Instructions

SENECA s.r.l. Commercial

Language of the manual

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

INSTALLATION MANUAL. VPN Industrial Gateway, Serial Device Server, Router 3G+ /4G, GPS and built-in I/O s

Advanced GSM/GPRS device for the telecontrol

Modbus Digital Remote I/O. ARM Series. Modbus Sensor Connector Type Digital Remote I/O. Features. User Manual For Communication. Ordering Information

CEM M-RS485 INSTRUCTION MANUAL (M014B A)

TP32MTT.03 TP32MTT [ GB ] Probes for soil thermal profile measurement

JUMO mtron T Measuring, Control, and Automation System

VirtualSCADA VSU-485G USB to RS422/485 Isolated Converter User Manual

Installation Instructions

IPM-S500 Series MID SINGLE PHASE AND THREE-PHASE ENERGY COUNTERS

FieldPoint. FP-1000/1001 FieldPoint Quick Start Guide. Install the Network Module Mount the module on a DIN rail. What You Need to Get Set Up

Island bus expansion module

UNIVERSAL CURRENT CONVERTER

Installation and commissioning guide SmartLink PSD Power Supply Module (DC)

ICF-1150 Series Quick Installation Guide

Energy Management BUS Adapter Type VMU-B 01

VMU-MC and VMU-OC. Pulse concentrator. Benefits. Description

RS485 MODBUS Module 6RO

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD.

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

TRP-C08. USB to RS232/422/485 Isolated Converter. User s Manual. Printed Sep.2014 Rev 1.4

USB/RS-485 INTERFACE CONVERTER PD10 TYPE USER S MANUAL

EX KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection)

ICF-1150 Series Quick Installation Guide

MINI MCR-SL-UI-2I-NC. Extract from the online catalog. Order No.:

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

TCF-142-RM Series Hardware Installation Guide

ioselect Z-NET Z-SG Bridge Input Isolating I/O Module

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

UniPak UP448 Bridge Input Isolating Signal Conditioner

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

ELSETA IOMOD 8DI8DO. User manual. Elseta 3/2017 V1.0

UC-8410A Quick Installation Guide

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

DCC-8 DIGITAL TO EIGHT CURRENT LOOP CONVERTER OPERATING MANUAL

JUMO Quantum PID100/PID200/PID300

Mini Energy Web Server

USER MANUAL Z-KEY MODBUS ETHERNET SERIAL GATEWAY AND SERIAL DEVICE SERVER. Via Austria, PADOVA ITALY

Product Manual. USB BAY-4 Port Serial DB- 9 RS-232 Adapter with FTDI Chipset. Coolgear, Inc. Version 1.1 September 2017 Model Number: USBG-BAY4

S-Line HIGH BRIGHTNESS AND ACCURACY DIGITAL LED INDICATORS MODULAR INDICATORS / TOTALIZERS WITH UNIVERSAL ANALOG INPUT

TCNM-ACBB1 Installation Manual

DTM Distributed Transmitter Monitor

Multifunction Transducer MT440

PRELIMINARY. USB1 / USB2 USB host interface to read data via memory stick. Bus Out (system bus) For connection to a router

Enhanced communication

MODEL: R2K-1 SEN TRONIC AG. R2K Series

Temperature controller Ducted systems

ECLYPSE Communication Modules

Any device, including routers and hosts, is running an implementation of IP address Host

Energy Management BUS Adapter Type VMU-B

Industrial Serial RS-232 to Fiber Converter. KSC-200 Series. Installation Guide

ECLYPSE Communication Modules

EXPANSION PERIPHERAL CVM-R10 C. (Code ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

FLEX Ex Spring Clamp Terminal Base

converter Tel: Fax:

S401-L Panel Mounting Indicator with OLED data Display.

Communicative controller for VAV systems

SDM120C. Single-Phase Energy Meters. RS485 Modbus RTU. User Manual V1.0

Electrical Energy Meter with integrated Serial Modbus interface

ISE 021 S-DIAS Interface Module RS232 / RS485

Digital Frequency Divider INSTRUCTION MANUAL CONTENTS. 1. Working Principle Installation Setting Up Technical Data 4.

JUMO mtron T Measuring, Control, and Automation System

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

DT1102 V (PS) Fully Configurable Galvanic Isolator. Operating Instructions

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

Three-phase electricity meter with instantaneous reading of electrical variables. Input current measurement: 5 A, 90 A, 150 A, 250 A (span by model).

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

Voltage Transducer UMT516 / MT516

Arm-based palm-sized industrial computers with 2 serial ports and 2 LAN ports. Features and Benefits. Certifications

PSI-MODEM-SHDSL/SERIAL

Screw terminal panels, Relay output boards, connection cables

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

Insulated Enclosure KS 4400 with fixed or pluggable screw or cage clamp terminals

MINI MCR-SL-CVS NC

Iso DIN. User Manual. 1 channel Earth Fault Monitoring

MIC-2 MKII, Multi-instrument DATA SHEET

TEMPERATURE AND HUMIDITY TRANSDUCER P18 TYPE USER S MANUAL

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

TM3AI4 module TM3-4 analog inputs

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

FP-2000/2010 FieldPoint Quick Start Guide

TRP-C08S. USB To 1* RS232 and 1*RS422/485 Isolated Converter. User s Manual. Printed Jun Rev 1.2

Z-PC Line REMOTE I/O SYSTEM. Cost-effective & easy to manage TCP-IP

Transcription:

ASYNCHRONOUS SERIAL CONVERTER RS485/USB S107USB/K107USB GENERAL DESCRIPTION The S107USB and K107USB instruments, represent an interface able to implement an asynchronous RS485 serial port, by using an USB port present on the PC. Thanks to the provided driver, the serial interface is considered by the operating system as a standard serial port; so the use of the product is directly allowed through any software able to communicate with the standard serial ports of the operating system (COM1, COM2, etc). The electrical insulation between the RS485 and the USB ports, allows to remove many problems of electrical noise which may occur when the connected equipment is very far from the PC. GENERAL FEATURES Usable in Windows 98, 2000 and XP Environments. Usable in Linux Environment with Kernel 2.4.20 or later, for which the direct support exists. Compatible with 1.1 and 2.0 USB standard port. Insulation between USB and RS485: 1500 V. Max Consumption: 60 ma. Power Supply provided from the USB port of the PC. Terminator of RS485 line, settable through an external bridge. Baudrate: 1200 bps)115200 bps. RS485 Serial communication through MODBUS RTU protocol, 32 nodes max. Possibility of multiple connection of more S107USB or K107USB to the same PC. Three leds to view the status of the module s activity. Accessories: CD with driver. USB connection cable: USB A and MINI USB B connectors. RS485 Connections of S107USB: removable 5-way screw terminals. RS485 Connections of K107USB: Spring terminals, Conductor Section: 0.2..2.5 mm 2, Wire stripping: 8 mm. Environmental conditions: Temperature: -20..65 C. Humidity: 10%..90% non-condensing. Installation Category: II. Pollution Degree 2. Storage Temperature: -40..85 C Protection Index: IP20 Weight, Dimensions: Standards: TECHNICAL SPECIFICATIONS S107USB: 24 g, 40 x 48 x 20,17 mm K107USB: 43 g, 6,2 x 93,1 x 102,5 mm EN61000-6-4/2002 (electromagnetic emission, industrial environment) EN61000-6-2/2005 (electromagnetic immunity, industrial environment) EN61010-1/2001 (safety). INSTALLATION RULES S107USB INSTALLATION RULES For S107USB module there are not particular warnigs, we only advise to use screened cables for the RS485 line in case of long connections or noisy environments (refer to Electrical Connections section). Pagina 1 of 6

K107USB INSTALLATION RULES This module has been designed for mounting on a DIN 46277 rail. Assembly in vertical position is recommended in order to increase the module's ventilation, and no raceways or other objects that compromise aeration must be positioned in the vicinity. Do not position the module above equipment that generates heat; we recommend positioning the module in the lower part of the control panel or container compartment. Inserting the module in the rail Removing the module from the rail 1) Attach the module in the upper part of the rail. 2) Press the module downwards. 1) Apply leverage using a screwdriver (as shown in the figure). 2) Rotate the module upwards. In case of long connections or noisy environments, it is advisable to use screened cables for the RS485 line (refer to Electrical Connections section). ELECTRICAL CONNECTIONS S107USB ELECTRICAL CONNECTIONS The following figure shows the electrical connections for S107USB module. By inserting an external bridge between T1 and T2 terminals, the terminator of the RS485 line is inserted. In case of long connections or noisy environments, it is advisable to use screened cables for the RS485 line. Pagina 2 of 6

K107USB ELECTRICAL CONNECTIONS The following figure shows the electrical connections for K107USB module. By inserting an external bridge between T1 and T2 terminals, the terminator of the RS485 line is inserted. In case of long connections or noisy environments, it is advisable to use screened cables for the RS485 line. Terminals Connections The module has been designed for spring-type terminal electrical connections. Proceed as follows to make the connections: 1 - Strip the cables by 0.8 mm 2 - Insert a screwdriver in the square hole and press it until the cable lock spring opens. 3 - Insert the cable in the round hole. 4 - Remove the screwdriver and make sure that the cable is tightly fastened in the terminal. Pagina 3 of 6

LEDS SIGNALLING Both the modules have three leds which allow to visualize the status of the module s activity. LEDS POSITION ON S107USB On S107USB module, the leds are positioned on the following way: LEDS POSITION ON K107USB On K107USB module, the leds are positioned on the following way: LEDS MEANING On both modules the leds are identified with the same name and have the following meaning: NAME COLOUR MEANING POWER Yellow If it is lighted, it indicates that the instrument is correctly supplied. Rx Red It lights when the module receives data through the RS485 port. Tx Red It lights when the module transmits data through the RS485 port. Pagina 4 of 6

PROBLEMS SOLVING For any problems with the converter, verify the following points: PROBLEM The POWER Led does not light The Rx Led is steady on The received data are not correct VERIFY Verify that the USB port of the PC provides the 5 V which are necessary to supply the module. Verify that the RS485 cables have not been swapped. Verify the communication speed. DRIVER INSTALLATION The CD containing the instrument s driver is provided to the user. In this section the installation procedure of the driver will be briefly described. It is necessary to specify that the installation in Linux (with Kernel 2.4.20 or later) environments is automatic and does not need the CD with the driver. The standard serial port of the PC which identifies the device is the following: /dev/ttyusb0. As regards Windows operating systems, it is important to underline that the procedure is divided into two phases which are both fundamental for the final use of the instrument. On the first phase, the driver of the out-and-out serial converter is installed. By the second phase instead the virtual driver will be installed: this will allow to use the peripheral as a standard serial port of the operating system. If case of use of Windows 2000, these two phases are identical and are performed step by step: the user has only to follow the guided procedure; instead in Windows 1998 the second phase is automatically managed by the operating system without any further dialogue with the user. In Windows XP the two phases are performed very quickly by the operating system if it the CD with the drivers has been inserted. For the correct installation it is important to insert the CD with the driver and connect the device to the PC already turned on, so that the operating system may automatically detect the presence of the device. At this point the the user has only to follow the guided installation. VISUALIZATION OF THE VIRTUAL COM PORT At the end of the installation, it is possibile to view the name which has been assigned to the virtual serial port associated to the used S107USB or K107USB device. For example on the following Device Manager panel, it has been identified as COM7: Pagina 5 of 6

SENECA s.r.l. Via Austria, 26-35127 PADOVA - ITALY Tel. +39.049.8705355-8705359 Fax +39.049.8706287 e-mail: info@seneca.it www.seneca.it Pagina 6 of 6